Data Sheet

Unimaster
Dust Filters
Series UMA 450

A 380 1550 B
for cleaner motor required for
Cleaned cover removal 230 min. clearance
106 air outlet maintenance
Acoustic diffuser (AD)
(as illustrated),
secondary filter (SF) or
105 105 absolute filter (AB) Terminal box

Fan chamber
Bin balance spigot (optional) C
D for standard
for hopper Filter chamber units
type units
Cleaner motor
(0.18 kW)
Dust inlet spigots
170 ´ 310 inside**
(at sides and/or at rear)
Seating level

f e
Quick-release to joint to centre
sealer gear line of inlet
spigots

Dust container

FRONT ELEVATION SIDE ELEVATION

Unimaster standard and hopper type dust control units


Model UMA 454 AD illustrated. Suitable for inside locations.

SPECIFICATIONS
Unit Filtration DIMENSIONS in mm* Fan Motor Dust Approx
type area A B C d e f type rating container net
(x2) weight
K10 5.5 kW 545 kg
454 AD 42m2 1515 965 2886 - 873 1056 K11 7.5 kW 55 litre 610 kg
K10 5.5 kW 560 kg
456 AD 42m2 1515 965 3114 - 1102 1284 K11 7.5 kW 80 litre 620 kg
K10 5.5 kW 565 kg
458 AD 42m2 1515 965 3114 - 1102 1284 K11 7.5 kW 110 litre 625 kg
K10 5.5 kW 410 kg
450H AD 42m2 1515 965 - 1830 - - K11 7.5 kW - 460 kg

454 SF 42m2 1515 965 3104 - 873 1056 K10 5.5 kW 55 litre 615 kg
K11 7.5 kW 680 kg
456 SF 42m2 1515 965 3332 - 1102 1284 K10 5.5 kW 80 litre 630 kg
K11 7.5 kW 690 kg
458 SF 42m2 1515 965 3332 - 1102 1284 K10 5.5 kW 110 litre 635 kg
K11 7.5 kW 695 kg
450H SF 42m2 1515 965 - 2050 - - K10 5.5 kW - 480 kg
K11 7.5 kW 530 kg

454 AB 42m2 1515 965 3304 - 873 1056 K10 5.5 kW 55 litre 645 kg
K11 7.5 kW 710 kg
456 AB 42m2 1515 965 3532 - 1102 1284 K10 5.5 kW 80 litre 660 kg
K11 7.5 kW 720 kg
458 AB 42m2 1515 965 3532 - 1102 1284 K10 5.5 kW 110 litre 665 kg
K11 7.5 kW 725 kg
450H AB 42m2 1515 965 - 2250 - - K10 5.5 kW - 510 kg
K11 7.5 kW 560 kg
*Tolerance ±3mm **DCE tolerance - 0mm to +2mm (NOTE: Outside dimensions of duct connectors must not exceed inside dimensions of inlets)

Publication 363M (GB) • 0702


Donaldson Torit DCE reserve the right to alter design without notice. Freedom from patent restrictions must not be assumed.
Data Sheet
Unimaster Dust Filters – Series UMA 450

105 A 380 960 B


90 Cleaned for cleaner motor cover removal required for
maintenance 230 min. clearance
air outlet 105
Bin balance spigot
D (optional)
for venting
type units Filter chamber Cleaner motor
without dust (0.18 kW)
containers C
Dust inlet spigots for venting
170 ´ 310 inside** type units
Seating level with dust
(at sides and/or at rear)
containers
f e
Quick-release to joint to centre
sealer gear line of inlet
spigots

Dust container

FRONT ELEVATION SIDE ELEVATION


Unimaster venting type dust control units
Model UMA 454 V illustrated. Suitable for inside locations and outside when fitted with side outlet box and weather cowl.

SPECIFICATIONS

Unit Filtration DIMENSIONS in mm* Dust Approx


container net
type area A B C d e f (x2) weight

454 V 42m2 1515 965 1855 - 873 1018 55 litre 350 kg

456 V 42m 2
1515 965 2083 - 1102 1246 80 litre 360 kg

458 V 42m 2
1515 965 2083 - 1102 1246 110 litre 365 kg

450 V 42m 2
1515 965 - 874 - - - 215 kg

*Tolerance ±3mm **DCE tolerance - 0mm to +2mm (NOTE: Outside dimensions of duct connectors must not exceed inside dimensions of inlets)

DUST CONTAINERS

Base Approx. Typical dust densities


Size diameter Height net weight
Dust Density with 50%
55 litre 420mm 400mm 5 kg voidage, in kg/litre
Sander 0.13
80 litre 420mm 630mm 7 kg
Graphite 0.80
110 litre 555mm 630mm 8 kg Sand 1.33
55 litre 80 litre 110 litre A reasonable total load for Iron 3.58
(2ft3) (3ft3) (4ft3) removal by hand would be 25 kg Steel 3.72

1515 1515 = 228 295 228 =

38.5 185

70 750 70 300 347


965 965 49 965

125 38.5
357 303
125 29 29
200

52 49
72
552 335 845 335 1515
115

Acoustic diffuser Secondary filter and absolute filter Venting type unit
All holes Æ5.5mm. Pitch centres: 125mm. All holes Æ4mm. Pitch centres: 100mm.
Cleaned air outlet details
All outlet grilles shown as punched.

2
Data Sheet
Unimaster Dust Filters – Series UMA 450

400
STATIC PRESSURE AVAILABLE AT FAN INLET (mm W.G.)

350

300

250

200
K11
(7.5 kW)
150
K10
(5.5 kW)
100

50
UNIT RESISTANCE CURVE

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000
AIR VOLUME (m3/h)

UMA 450 performance curves

FAN SELECTION
These curves indicate static pressure available at fan inlet for a given volume, when fitted inside a Unimaster unit.
To select the most suitable fan for a given application:
1 Determine the air volume, in m³/h, needed to entrain the dust.
2 Read off the unit resistance, in mm W.G., at air volume required.
3 Assess pressure drop across filter bags prior to cleaning, usually 50-100mm W.G.
4 Estimate pressure drop through connected system - i.e. between point of entrainment and unit inlet.
5 The sum of 2, 3 and 4 = W.G. required.
6 Consult graph for fan performances available.

NOISE LEVELS
Machinery noise levels are an important consideration in the design and selection of new equipment.
Several EC Directives and National Laws/Regulations adopting these directives make reference to airborne noise emissions.
Actions that employers are required to comply with if employees are subjected to a daily personal
noise exposure Lep,d of 85 dB(A) or more are also specified.
All Unimaster UMA 450 dust control units are below this action limit.

WEIGHTED SOUND PRESSURE LEVELS


All readings were taken in normal industrial areas, i.e. semi-reverberant surroundings, with local equipment silent.
Measurements were taken at maximum air flow conditions at 1.0 metre radius from the equipment housing
and 1.6 metres above base level, using a precision sound level meter and octave filter.
K10 K11
74 dB(A)* 76 dB(A)
Noise measurements of installed equipment may vary due to site conditions. *Estimated data.

3
29 1536 974 75
230 min. clearance

165 204 229


367

22 921 22 = 924 =
194
DETAIL OF CLEANED AIR FRONT ELEVATION SIDE ELEVATION
OUTLET WITH WEATHER
COWL REMOVED
Unimaster side outlet box and weather cowl
Model UMA 450 V illustrated. Outlet grille is shown as punched.

100

113.5
(75.5 on venting
type units with
dust containers)
729

REAR ELEVATION SIDE ELEVATION

Explosion relief panel and rear dust inlet spigots


Model UMA 454, standard unit illustrated.

1504 15.5 1554 15.5


15
40 1424 40
40 53 20

965

746 666 600 706 1035 1005


'MEMBREX' EXPLOSION
RELIEF MEMBRANE
1515

40 53 20
57 1350 57
15
20 1464 20 1585

Explosion relief flange mounting details Aperture and mounting flange details for
All holes Æ10mm for M8 bolts. Pitch centres: 150mm. hopper and venting type units
All holes Æ12mm for M10 bolts.
Pitch centres: 222mm horizontally; 201mm vertically.

Humberstone Lane Research Park Zone 1


Thurmaston Interleuvenlaan 1
Leicester LE4 8HP B-3001 Leuven (Heverlee)
England Belgium
www.toritdce.com Tel +44 (0)116 269 6161 Tel +32 (0)16 383 970
www.donaldson.com Fax +44 (0)116 269 3028 Fax +32 (0)16 383 938
Email: toritdce.uk@mail.donaldson.com Email: toritdce.be@mail.donaldson.com