You are on page 1of 13

2013-2014 Electronic Catalog

Safety Interlock Switches


Product Selection Guide

Complete
Hinge Pin Switches
Interlock Subsection
Section Rev. 3.13
Safety Interlock Switches:
Switches Hinge Pin

Contents Contents
Selection Guide G2 Selection Guide
Tongue Switches G2
D4GS-N G139
Guardlocking Switches D4NS G146
Hinge Pin Switches
D4JL G6 T2008 G154
D4NH G57
D4NL G15 T4012 G159
D4SL-N G25
NEW! T4016 G164
Accessories
TL4019 G43 T5007 G169
Accessories G191
TL4024 G51 T5009 & T5009-6 G174

Hinge Pin Switches Explosion-Proof Switch


D4NH G57 XT5009 G180

Non-Contact Switches Accessories


CM Series G63 D4NS-SK/D4JL-SK G184
D40Z/D40A/G9SX-NS G75 Accessories G191
EC Series G92
MA Series G97
MA-S Series G103
MFS G109

Safety Limit Switches


D4B-□N G112
D4F G119
D4N G123
D4N-□R G131

G1
Safety Interlock Switches

Selection Guide Interlock

For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Hinge Pin Switches

Do you need
hinge operated?

yes

• D4NH — p. G57
(plastic 30 x 80 mm)

Accessories
From spare actuators to our switch locking devices, OMRON
Automation and Safety has you covered when it comes to
outfitting your safety interlocking needs.

• Cabling Components — p. G191

• Conduit LED Beacons — p. G192

• Conduit Lights and Remote Indicator — p. G192


Conduit LED Beacons
• Security Bits/Drives — p. G192

G02 www.sti.com/info
Safety Interlock Switches

D4NH D4NH

For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety-door Hinge Switch


• Compact, plastic-body safety-door hinge switch designed for
saving space in machines
• Lineup includes three contact models with 2NC/1NO and
3NC contact forms in addition to the previous contact forms
1NC/1NO, and 2NC. Models with MBB contacts are also
available
• M12-connector models are available, saving on labor and
simplifying replacement
• Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.

S
G

Specifications
Standards and EC Directives Certified Standard Ratings
Conforms to the following EC Directives: TÜV (EN 60947-5-1), CCC (GB14048.5)
• Machinery Directive
Item Utilization category AC-15 DC-13
• Low Voltage Directive
• EN50047 Rated operating current (Ie) 3A 0.27 A
• EN60204-1 Rated operating voltage (Ue) 240 V 250 V
• EN1088
Note: Use a 10 A fuse type gI or gG that conforms to IEC 60269 as a short-
• GS-ET-15 circuit protection device. This fuse is not built into the Switch.

Certified Standards UL/CSA (UL 508, CSA C22.2 No. 14)


Certification A300
Standard File No.
body Current (A) Volt-amperes (VA)
Rated Carry
Consult your voltage current
EN 60947-5-1 Make Break Make Break
TÜV SÜD representative for
(certified direct opening)
details. 120 VAC 60 6
10 A 7,200 720
UL * UL 508, CSA C22.2 No.14 E76675 240 VAC 30 3
Q300
CCC (CQC) GB14048.5 2004010305105973
*Certification for CSA C22.2 No. 14 is authorized by the UL mark. Rated Carry Current (A) Volt-amperes (VA)
voltage current Make Break Make Break
125 VDC 0.55 0.55
2.5 A 69 69
250 VDC 0.27 .27

www.sti.com/info G57
D4NH Safety Interlock Switches

Structure and Nomenclature


Structure
(D4NH-□□BC) Arm Lever
Guard Closed Guard Open The arm lever is mounted upwards in the center
position before shipping. To change the position,
Cam loosen the arm lever mounting screw, dismount
the arm lever, and mount the arm lever in the left
Forced or right position.
separation
of NC The joint between the shaft and
contacts arm lever is formed with
form-lock construction which
When remains secure even when the
opening screw becomes loose.
the guard
When the guard is opened, the cam that is directly coupled to
the shaft rotates to press the Switch in the direction shown by Head
the (vertical) arrow. This action separates the contacts to stop The head can be mounted in four directions.
the machine.
Built-in Switch
The built-in switch has a direct opening mechanism Conduit
that forcibly separates the NC contact even when A wide variety of conduits is available.
there is contact deposit.
Size Box 1-conduit 2-conduit
Cover Pg13.5 Yes Yes
The cover, with a hinge on its lower part, can be G1/2 Yes Yes
opened by removing the screw of the cover, which 1/2-14NPT Yes Yes
ensures ease of maintenance and wiring.
M20 Yes Yes
Note: The housing and head of the D4NH are made of resin. Use D4BS ---
M12 Connector Yes
Safety-door Switches for applications requiring safety door switches of tough,
high-sealing, or oil-resistant construction. Note: M12 connector types are not available for
G Switches with three contacts.

Connections
Contact Form
Model Contact Contact form Operating pattern Remarks
Only NC contacts 11-12 have a
Zb certified direct opening
11-12
D4NH- 11 12 ON mechanism.
1NC/1NO 33-34
□A□ 33 34 Stroke
The terminals 11-12 and 33-34
can be used as unlike poles.
Only NC contacts 11-12 and
Zb
11-12
31-32 have a certified direct
D4NH- 11 12
ON opening mechanism.
2NC 31-32
□B□
31 32 Stroke The terminals 11-12 and 31-32
can be used as unlike poles.

Zb
Only NC contacts 11-12 and
11-12 21-22 have a certified direct
11 12
D4NH- 21-22 ON opening mechanism.
2NC/1NO
□C□ 21 22 33-34 The terminals 11-12, 21-22, and
33 34 Stroke 33-34 can be used as unlike Notes:
poles. 1. Terminals are
numbered according
Only NC contacts 11-12, 21-22, to EN50013. Contact
Zb
11-12 and 31-32 have a certified forms are according
11 12
D4NH- 21-22 ON direct opening mechanism. to EN60947-5-1.
3NC
□D□ 21 22 31-32 The terminals 11-12, 21-22, and 2. MBB (Make Before
31 32 Stroke 31-32 can be used as unlike Break) contacts
have an overlapping
poles.
structure, so that
Only NC contacts 11-12 have a before the normally
Zb certified direct opening closed contact (NC)
11-12
D4NH- 1NC/1NO 11 12 ON mechanism. opens, the normally
33-34
□E□ MBB* open contact (NO)
33 34 Stroke The terminals 11-12 and 33-34 closes.
can be used as unlike poles. * MBB (Make Before
Break) contacts
Zb Only NC contacts 11-12 and have an overlapping
11-12 21-22 have a certified direct structure, so that before
11 12
21-22 ON opening mechanism. the normally closed
D4NH- 2NC/1NO
contact (NC) opens, the
□F□ MBB* 21 22 33-34
Stroke
The terminals 11-12, 21-22 and normally open contact
33 34
33-34 can be used as unlike poles. (NO) closes.

G58 www.sti.com/info
D4NH Safety Interlock Switches

Dimensions and Operating Characteristics (mm)

Shaft Type with 1 Conduit


D4NH-1□AS D4NH-2□AS
D4NH-3□AS D4NH-4□AS
D4NH-9□AS *

(31.5) 28±2 Two, 3.2±0.1 dia.


Red 11±0.2 8.5±0.1 dia.
20.5 × 20.5
8 Depth: 20 min.

12.5 dia.18 dia.


27.5
18
9±0.2 2.5 Operating force OF max. 0.15 N·m
Black Two, 3.2±0.1 dia.
7±0.2 Pretravel PT 1 (NC) (7°) (MBB: 10°)
20±0.1 21.5
13±0.2 Pretravel PT 2 (NO) (19°) (MBB: 5°)
47±0.2 22±0.1
55
Direct opening travel DOT min.* 18°
2.15±0.05R
mounting holes Direct opening force DOF min. 1 N·m
*Be sure to provide this amount to ensure safety
Two, 4+0.15
0 dia. holes
in operation.
22±0.2 Conduit 14.2
31max. cap
30 Depth: 5

G
Shaft Type with 2 Conduits
D4NH-5□AS D4NH-6□AS
D4NH-7□AS D4NH-8□AS

(31.5) 28±2
Red 42±0.1 21.5 Two, 3.2±0.1 dia.
40±0.1 11±0.2 8.5±0.1 dia.
20.5 × 20.5 8 Depth: 20 min. Operating force OF max. 0.15 N·m
Black
Pretravel PT 1 (NC) (7°) (MBB: 10°)
12.5 dia.18 dia.
2.5 27.5 Pretravel PT 2 (NO) (19°) (MBB: 5°)
18
9±0.2
Two, 3.2±0.1 dia. Direct opening travel DOT min.* 18°
5.4 20.5 7±0.2 Direct opening force DOF min. 1 N·m
20±0.1
39±0.2 25 dia. 13±0.2 *Be sure to provide this amount to ensure safety
47 22±0.1
in operation.
Cap
2.15±0.05R
42±0.2
mounting holes Two, 4+0.15
0 dia. holes
Conduit cap 14.2 Depth: 5
56 max. (3) 30

Notes: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.


2. Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
*Refer to the M12 connector diagram for details.

1-conduit M12 Connector


D4NH-9□□□

(14)
M12 × 1
14.2
30

www.sti.com/info G59
D4NH Safety Interlock Switches

Dimensions and Operating Characteristics (continued) (mm)

Arm Lever Type with 1 Conduit


D4NH-1□BC D4NH-2□BC
D4NH-3□BC D4NH-4□BC
D4NH-9□BC *
16
5.1

43
80±1
Red 1.5
(26.7) Operating force OF max. 0.15 N·m
(10.3)
29±1
Pretravel PT 1 (NC) (7°) (MBB: 10°)
Black (16.5) Pretravel PT 2 (NO) (19°) (MBB: 5°)
20.5×20.5
27.5 Direct opening travel DOT min.* 18°
18
9±0.2 2.5 Direct opening force DOF min. 1 N·m
11±0.2 *Be sure to provide this amount to ensure safety
20±0.1
21.5 in operation.
47±0.2 22±0.1
55
2.15±0.05R
mounting holes

Conduit Two, 4+0.15


0 dia. holes
22±0.2 cap 14.2 Depth: 5
30
31 max.
(37.9)

G
Arm Lever Type with 2 Conduits
D4NH-5□BC D4NH-6□BC
D4NH-7□BC D4NH-8□BC
16
5.1

Operating force OF max. 0.15 N·m


43 Pretravel PT 1 (NC) (7°) (MBB: 10°)
80 Pretravel PT 2 (NO) (19°) (MBB: 5°)
1.5
(26.7) Direct opening travel DOT min.* 18°
(10.3)
Direct opening force DOF min. 1 N·m
Red 29±1
(16.5) *Be sure to provide this amount to ensure safety
20.5×20.5
2.5 27.5 in operation.
Black 18 11±0.2
9±0.2
21.5
5.4 20±0.1 20.5
22±0.1
39±0.2 40±0.1 25 dia.
47
42±0.1
Cap
2.15±0.05R
mounting holes Two, 4+0.15 dia. holes
42±0.2 0
Conduit cap 14.2 Depth: 5
56 max. (3) (37.9)

Notes: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.


2. Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
*Refer to the M12 connector diagram for details.

G60 www.sti.com/info
D4NH Safety Interlock Switches

Application Examples
Arm Lever Use
(Be sure to evaluate the Switch under actual workign conditions after installation.)

When Installing at the Center When Installing to the Left When Installing to the Right
The arm lever is set for center installation at the Remove the screw and arm lever, position the Remove the screw and arm lever, position the
time of shipment. arm lever to the left, and then secure it with the arm lever to the right, and then secure it with the
screw. screw.

Note: Install the arm lever so that it will not rotate Note: Install the arm lever so that it will not rotate Note: Install the arm lever so that it will not rotate
more than 90°. more than 180°. more than 180°.

Protective Door Safety Measures

Shaft Actuator Arm Lever Actuator

www.sti.com/info G61
D4NH Safety Interlock Switches

Ordering
Model Number Structure

D4NH – □ □ □
1 2 3
1 Conduit Size 2 Built-in Switch 3 Actuator
1: Pg13.5 (1-conduit) A: 1NC/1NO (slow-action) AS: Shaft
2: G1/2 (1-conduit) B: 2NC (slow-action) BC: Arm lever
3: NPT C: 2NC/1NO (slow-action)
4: M20 (1-conduit) D: 3NC (slow-action)
5: PG13.5 (2-conduit) E: 1NC/1NO (MBB contact)
6: G1/2 (2-conduit) (slow-action)
7: 1/2-14NPT (2-conduit) F: 2NC/1NO (MBB contact)
8: M20 (2-conduit) (slow-action)

List of Models
G Switches with certified direct opening mechanisms

Built-in switch mechanism Built-in switch mechanism


Act- Act-
Conduit size 1NC/1NO 2NC 2NC/1NO Conduit size 1NC/1NO 2NC/1NO
uator uator 3NC
(Slow-action) (Slow-action) (Slow-action) MBB MBB
(Slow-action)
(Slow-action) (Slow-action)
Pg13.5 D4NH-1AAS D4NH-1BAS D4NH-1CAS
Pg13.5 D4NH-1DAS D4NH-1EAS D4NH-1FAS
G1/2 D4NH-2AAS D4NH-2BAS D4NH-2CAS
G1/2 D4NH-2DAS D4NH-2EAS D4NH-2FAS
1-conduit D4NH-4AAS- D4NH-4BAS- D4NH-4CAS-
NPT 1-conduit D4NH-4DAS- D4NH-4EAS- D4NH-4FAS-
Shaft NPT NPT NPT NPT
Shaft NPT NPT NPT
M20 D4NH-4AAS D4NH-4BAS D4NH-4CAS
M20 D4NH-4DAS D4NH-4EAS D4NH-4FAS
2- G1/2 D4NH-6AAS D4NH-6BAS D4NH-6CAS
2- G1/2 D4NH-6DAS D4NH-6EAS D4NH-6FAS
conduit M20 D4NH-8AAS D4NH-8BAS D4NH-8CAS conduit M20 D4NH-8DAS D4NH-8EAS D4NH-8FAS
Pg13.5 D4NH-1ABC D4NH-1BBC D4NH-1CBC
Pg13.5 D4NH-1DBC D4NH-1EBC D4NH-1FBC
G1/2 D4NH-2ABC D4NH-2BBC D4NH-2CBC
G1/2 D4NH-2DBC D4NH-2EBC D4NH-2FBC
D4NH-4ABC- D4NH-4BBC- D4NH-4CBC- 1-conduit
1-conduit NPT D4NH-4DBC- D4NH-4EAS- D4NH-4FBC-
NPT NPT NPT Arm NPT
Arm NPT NPT NPT
lever M20 D4NH-4ABC D4NH-4BBC D4NH-4CBC lever
M20 D4NH-4DBC D4NH-4EBC D4NH-4FBC
M12 --- D4NH-9BBC ---
connector 2- G1/2 D4NH-6DBC D4NH-6EBC D4NH-6FBC
2- G1/2 D4NH-6ABC D4NH-6BBC D4NH-6CBC conduit M20 D4NH-8DBC D4NH-8EBC D4NH-8FBC
conduit M20 D4NH-8ABC D4NH-8BBC D4NH-8CBC
Notes: 1. It is recommended that M20 be used for Switches to be exported
to Europe and NPT be used for Switches to be exported to North
American countries.
2. All models have slow-action contacts with certified direct opening
mechanisms on NC contacts only.
* The 1/2-14NPT 2-conduit models include an M20-to-1/2-14NPT changing
adaptor.

G62 www.sti.com/info
Safety Interlock Switches

Accessories Interlock

For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

OMRON Automation and Safety has a complete line of accessory products for your safety inter-
lock needs. For specific part numbers for replacement actuators or fuses, please refer to the specific
product datasheet. Contact Omron for any concerns or questions.

Replacement Contact Blocks


Part No.
BL6009, 2 N/C + 1 N/O, Rear Mounting 44512-0400
ER6019, 2 N/C + 1 N/O, Side Mounting 44512-0390
ER1022, ER1032, ER5018, ER6022, 2 N/C + 1 N/O terminals (11/12, 21/22, 33/34) 44512-2020
ER1022, ER1032, 2 N/C + 1 N/O terminals (41/42, 51/52, 63/64) 44512-2021
ER5018, ER6022, 3 N/C 44512-2030
ER6022, 2 N/C + 2 N/O 44512-2221
ER6022, 3 N/C + 1 N/O 44512-2311
ER6022, 4 N/C 44512-2400
HP6009, 2 N/C + 1 N/O, Side Mounting 44512-0390 G
T5009, 2 N/C + 1 N/O 44512-3210
T5009-6, 3 N/C + 1 N/O 44512-3310
T5009-6, 4 N/C 44512-3400

Micro Style Cables


Part No.
MA-2, 6, 9, 20, MC-S3, HP2007, T2007, T5007, Plastic SL Series, D4NS
5 m Cable with 4-Pin Female Connector Micro DC 44512-0600
10 m Cable with 4-Pin Female Connector Micro DC 44512-0610
CM & MC Series
5 m Cable with 8-Pin Female Connector 44512-0620
10 m Cable with 8-Pin Female Connector 44512-0630
HP3009, T3009, T5009, MA-21, Plastic SL Series, MA-15, MA-35, MFS
5 m Cable with 6-Pin Female Connector (Dual Keyway) 44512-0640
10 m Cable with 6-Pin Female connector (Dual Keyway) 44512-0650

Cabling Components
Part No.
M16 to NPT Adapter 44512-0300
M16 Cord Grip (4-7 mm ID) 44512-0080
M20 to PG11 44512-0120
M20 to NPT Adapter 44512-0110
M20 to NPT Adapter (steel) 44512-0310
M20 Cord Grip (4-5 mm ID) 44512-0090
M20 Cord Grip (7-10 mm ID) 44512-0410
M20 Blanking Plug 44512-0100
M20 Plastic Nut 10-Pack 44512-0105
NPT to M20 Adapter 44512-1010

(Continued on next page)

www.sti.com/info G191
Accessories Safety Interlock Switches

Conduit LED Beacons (High-Intensity)


Part No.
Conduit LED, M20, Amber, 24 VDC 44512-0500
Conduit LED, M20, Amber, 110 VAC 44512-0510
Conduit LED, M20, Red, 24 VDC 44512-0520
Conduit LED, M20, Red, 110 VAC 44512-0530
Conduit LED, M20, Green, 24 VDC 44512-0540
Conduit LED, M20, Green, 110 VAC 44512-0550

Conduit LED Beacons


Part No.
Conduit LED, M20, Amber, 24 VDC 44512-1500
Conduit LED, M20, Red, 24 VDC 44512-1520
Conduit LED, M20, Green, 24 VDC 44512-1540

Conduit Lights and Remote Indicator


Part No.
Conduit Light, M20, Amber, no bulb 44512-0130
G
Conduit Light, M20, Red, no bulb 44512-0290
Conduit Light, NPT, Amber, no bulb 44512-0260
Conduit Light, NPT, Red, no bulb 44512-0420
Bulb for Conduit Light, 24 VAC/DC 44512-0200
Bulb for Conduit Light, 110 VAC 44512-0140
Bulb for Conduit Light, 220 VAC 44512-0190

Security Bits/Drives
Part No.
Spare Bit for Security Screw 44512-0050
Screwdriver for Security Bit 44512-0040
Lockoff Actuator for T4011, T5007, T5009, TL5012, TL8012-S 44512-0700

Lockoff Actuator

G192 www.sti.com/info
Accessories Safety Interlock Switches

Universal Mounting Brackets


• Quickly and easily mounts non-contact • Use the universal mounting brackets to
switches and actuators to structural mount non-contact switches to Ferrous
aluminum profiles metals with minimal loss of range
• Quickly and easily mounts tongue • Designed to allow for easy
actuated safety interlock switches to alignment of switch to actuator
structural aluminum profiles • Constructed from 6060-T5 aluminum,
• Quickly and easily mounts hinge these brackets are resistant to harsh
operated safety interlock switches to environments
structural aluminum profiles

25.78 7.11
1.02 0.28

M4 x8
91.25 5.31
0.21
G
3.59

Mounting slots
are designed for
29.34
UMB-THP30 mounting bracket kit, being used to UMB-NC10
1.16 mounting bracket kit, beingsize
used
#10 orto
M5 The brackets are designed to allow for
hardware
mount a T2008 interlock switch. mount a CM-S2 switch and actuator. movement along two axis.

29.64
1.17

25.78 7.11 UMB Universal T-Nut


1.02 0.28 (User Supplied) Aluminum
Long bracket included with kit UMB-NC10 Mounting Bracket
Structural
Bolt, M5 or #10
Profile
Bracket, Mounting (User Supplied)
M4x8 Kit #UMB-NC10
5.31 25.78 7.11
91.25 0.21 0.28
3.59 1.02 Screw, M4, Tamper-Proof
(OSTI Supplied)
15.24 5.31
Mounting slots 0.21
0.60
are designed for
29.34
1.16 size #10 or M5 Switch or Actuator
51.56 M4x8 Mounting slots
hardware
2.03 are designed for
29.21 size #10 or M5 Non-Contact
1.15
hardware
29.64 Bracket, Mounting
1.17
Kit #UMB-NC20
Kit #UMB-THP30
Short bracket included with kits UMB-NC20
Long bracket included with kit UMB-NC10 and UMB-THP30

25.78 7.11
1.02 0.28

15.24 5.31
0.60 0.21

Model
51.56
Description
M4x 8 Mounting slots Compatible Switches & Actuators Mounting Capability Part No.
2.03 are designed for
29.21
UMB-NC10
1.15 Universal MountingsizeBracket
#10 or M5 Kit for CM-S2, CM-S221, CM-S6, CM-S621, MA-6, Capable of 1 switch and 44512-3010
hardware
non-contact switches and actuators MA-9, MA-10, MA-11, MA-16, MA-S36, 1 actuator
(Includes long bracket) MC-S2, MF-1, MFS-12
UMB-NC20
Short Universal
bracket included with Mounting Bracket Kit for
kits UMB-NC20 CM-S1, CM-S11, CM-S31, CM-S5, CM-S521, Capable of 1 switch 44512-3020
and UMB-THP30 non-contact switches and actuators MA-14, MA-15, MA-S34, MA-S35, MC-S1, and 1 actuator
(Includes short bracket) MC-S31
UMB-THP30 Universal Mounting Bracket Kit for hinge HP2011, T2008, T2011 Capable of 1 switch 44512-3030
pins and tongue-actuated switches (switches only) (no actuator)
(Includes short bracket)
Note: Tamper-proof hardware is included with each kit to mount the switch or actuator to the Universal Mounting Bracket. No hardware is supplied to
mount the Universal Mounting Bracket to the aluminum profile.

www.sti.com/info G193
Accessories Safety Interlock Switches

SLD Series — Switch Locking Devices


• Allows personnel to quickly lock a safety • Designed to accept locks with standard
interlock switch to a safe position allow- shackle diameters of 5/16” or 7 mm;
ing for certain types of maintenance standard expansion devices may also
• Intended for use as an alternate control be used in conjunction with the SLD
method while performing tasks that • The SLD series will work for designated Optional stainless
are routine, repetitive or integral to the switches with or without the optional steel guide
production process (ANSI/ASSE Z244.1- stainless steel guide. If the optional
2003 (R2008) section 5.4) stainless steel guide is used on a switch
• Robust design and construction blocks that is integrated with a slide bolt as-
all access points to the actuation sembly, it will not be possible to attach a
mechanism of the safety interlock switch Switch Locking Device

G ✎ For SLD dimensions,


see www.sti.com/switches
Warning: The SLD Series is intended for use
as an alternative control method provided for
by ANSI/ASSE Z244.1-2003 (R2008) section
5.4. This device does not protect against
malicious tampering.

Model Compatible Interlock Switches Part No.


SLD26-01* T4011, T5007, T5009, TL8012-S, D4SL-N 44526-0801
SLD34-01** T2008, T2011, T4012, TL4019 44534-0801
SLD35-01*** T4016, TL4024 44535-0801
Notes:
*The SLD26-01 will not work with optional catch on T5007, or optional latch on T4011.
**The SLD34-01 is only compatible with slide bolt assemblies 44534-8130, -8140, -8070.
***The SLD35-01 is not compatible with slide bolt assemblies.

G194 www.sti.com/info

You might also like