The document summarizes the results of a tensile test of a 1/4" stainless steel bolt. It provides the maximum tensile force of 22.92 kN, modulus of 1394.21 GPa, and tensile strain at break of 35.33%. The test was run at a rate of 1 mm/min on a sample with a diameter of 6.12 mm, gage length of 61.47 mm, and total bolt separation of 92.46 mm.
The document summarizes the results of a tensile test of a 1/4" stainless steel bolt. It provides the maximum tensile force of 22.92 kN, modulus of 1394.21 GPa, and tensile strain at break of 35.33%. The test was run at a rate of 1 mm/min on a sample with a diameter of 6.12 mm, gage length of 61.47 mm, and total bolt separation of 92.46 mm.
The document summarizes the results of a tensile test of a 1/4" stainless steel bolt. It provides the maximum tensile force of 22.92 kN, modulus of 1394.21 GPa, and tensile strain at break of 35.33%. The test was run at a rate of 1 mm/min on a sample with a diameter of 6.12 mm, gage length of 61.47 mm, and total bolt separation of 92.46 mm.
General: Method name only Bolt Test Method Test: Rate 1 1.00 mm/min
Stainless Bolt Test - Page 1 of 2 Thursday, June 15, 2023 1:46:03 PM
1_20230615_131833.is_tens Specimen Maximum Tensile Modulus Tensile Tensile Force at Energy at Energy at label Force stress at (Automati stress at strain Break Break Maximum [kN] Maximum c Young's) Yield (Displace (Standard (Standard Force Force [GPa] (Offset 0.2 ment) at ) ) [J] [MPa] %) Break [kN] [J] [MPa] (Standard ) [%] Stainless 1 22.92 1394.21 83.93 830.76 35.33 13.86 467.16 417.34 Steel Specime Operator Area Diameter Gage Length of Fixture Bolt Bolt Specime n label (s) [mm^2] [mm] Length Entire separatio Grade Material n [mm] Bolt n Tempera [mm] [mm] ture [C] Stainless Stainless 1 Akshmith 16.44 6.12 61.47 92.46 39.52 22.00 Steel Steel
Stainless Bolt Test - Page 2 of 2 Thursday, June 15, 2023 1:46:03 PM