1. This document provides information on anchor sizes, embedment depth, material properties, and load cases for 6 anchors connecting a base plate to concrete.
2. The maximum tension force on an individual anchor is 10.572 kN and the maximum shear force is 0.6 kN. The resulting forces were calculated to be 30.777 kN in tension and 32.177 kN in compression.
3. Analysis of the anchors for tension loading shows the steel failure capacity is 30.933 kN and concrete failure capacity is 38.403 kN, with utilizations of 35% and 81% respectively, indicating the design is adequate.
1. This document provides information on anchor sizes, embedment depth, material properties, and load cases for 6 anchors connecting a base plate to concrete.
2. The maximum tension force on an individual anchor is 10.572 kN and the maximum shear force is 0.6 kN. The resulting forces were calculated to be 30.777 kN in tension and 32.177 kN in compression.
3. Analysis of the anchors for tension loading shows the steel failure capacity is 30.933 kN and concrete failure capacity is 38.403 kN, with utilizations of 35% and 81% respectively, indicating the design is adequate.
1. This document provides information on anchor sizes, embedment depth, material properties, and load cases for 6 anchors connecting a base plate to concrete.
2. The maximum tension force on an individual anchor is 10.572 kN and the maximum shear force is 0.6 kN. The resulting forces were calculated to be 30.777 kN in tension and 32.177 kN in compression.
3. Analysis of the anchors for tension loading shows the steel failure capacity is 30.933 kN and concrete failure capacity is 38.403 kN, with utilizations of 35% and 81% respectively, indicating the design is adequate.
Effective embedment depth: hef = 100 mm Material: 8.8 Approval No.: ETA- 02/0042 Issued I Valid: 22/11/2560 | - Proof: Design method ETAG (No. 001 Annex C/2010) Stand-off installation: eb = 0 mm (no stand-off); t = 6 mm Baseplate: lx x ly x t = 180 mm x 200 mm x 6 mm; (Recommended plate thickness: not calculated Profile: Rectangular hollow; (L x W x T) = 150 mm x 70 mm x 10 mm Base material: uncracked concrete, C20/25, fc,cube = 25.00 N/mm2; h = 200 mm Installation: hammer drilled hole, Installation condition: Dry Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm) no longitudinal edge reinforcement
R - user is responsible to ensure a rigid base plate for the entered thickness with appropriate solutions (stiffeners,...)
Geometry [mm] & Loading [kN, kNm]
2 Load case/Resulting anchor forces y Load case: Design loads 6 4 2 Anchor reactions [kN] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 0.000 0.600 0.600 0.000 2 0.000 0.600 0.600 0.000 x Tension Compression 3 4.817 0.600 0.600 0.000 4 4.817 0.600 0.600 0.000 5 10.572 0.600 0.600 0.000 6 10.572 0.600 0.600 0.000 5 3 1 max. concrete compressive strain: 0.28 [‰] max. concrete compressive stress: 8.27 [N/mm2] resulting tension force in (x/y)=(-48/0): 30.777 [kN] resulting compression force in (x/y)=(85/0): 32.177 [kN]
Anchor forces based on a rigid base plate assumption!
3 Tension load (ETAG, Annex C, Section 5.2.2)
Load [kN] Capacity [kN] Utilisation bN [%] Status Steel failure* 10.572 30.933 35 OK Pull-out failure* N/A N/A N/A N/A Concrete cone failure** 30.777 38.403 81 OK Splitting failure** N/A N/A N/A N/A * most unfavourable anchor **anchor group (anchors in tension)