You are on page 1of 3

1 Input data

Anchor type and size: HSL-3 M12 OR EQUIVALENT


Effective embedment depth: hef = 100 mm
Material: 8.8
Approval No.: ETA- 02/0042
Issued I Valid: 22/11/2560 | -
Proof: Design method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0 mm (no stand-off); t = 6 mm
Baseplate: lx x ly x t = 180 mm x 200 mm x 6 mm; (Recommended plate thickness: not calculated
Profile: Rectangular hollow; (L x W x T) = 150 mm x 70 mm x 10 mm
Base material: uncracked concrete, C20/25, fc,cube = 25.00 N/mm2; h = 200 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- user is responsible to ensure a rigid base plate for the entered thickness with appropriate solutions
(stiffeners,...)

Geometry [mm] & Loading [kN, kNm]


2 Load case/Resulting anchor forces y
Load case: Design loads
6 4 2
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.000 0.600 0.600 0.000
2 0.000 0.600 0.600 0.000 x
Tension Compression
3 4.817 0.600 0.600 0.000
4 4.817 0.600 0.600 0.000
5 10.572 0.600 0.600 0.000
6 10.572 0.600 0.600 0.000
5 3 1
max. concrete compressive strain: 0.28 [‰]
max. concrete compressive stress: 8.27 [N/mm2]
resulting tension force in (x/y)=(-48/0): 30.777 [kN]
resulting compression force in (x/y)=(85/0): 32.177 [kN]

Anchor forces based on a rigid base plate assumption!

3 Tension load (ETAG, Annex C, Section 5.2.2)


Load [kN] Capacity [kN] Utilisation bN [%] Status
Steel failure* 10.572 30.933 35 OK
Pull-out failure* N/A N/A N/A N/A
Concrete cone failure** 30.777 38.403 81 OK
Splitting failure** N/A N/A N/A N/A
* most unfavourable anchor **anchor group (anchors in tension)

3.1 Steel failure


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
46.400 1.500 30.933 10.572

3.2 Concrete cone failure


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm]
96,600 44,100 105 210
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
13 0.889 0 1.000 1.000 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
10.100 29.576 1.500 38.403 30.777
4 Shear load (ETAG, Annex C, Section 5.2.3)
Load [kN] Capacity [kN] Utilisation bV [%] Status
Steel failure (without lever arm)* 0.600 48.400 2 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout failure** 3.600 107.976 4 OK
Concrete edge failure in direction ** N/A N/A N/A N/A
* most unfavourable anchor **anchor group (relevant anchors)

4.1 Steel failure (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
60.500 1.250 48.400 0.600

4.2 Pryout failure


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm] k-factor
120,750 44,100 105 210 2.000
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
29.576 1.500 107.976 3.600

5 Combined tension and shear loads (ETAG, Annex C, Section 5.2.4)

bN bV a Utilisation bN,V [%] Status


0.801 0.033 1.000 70 OK
(bN + bV) / 1.2 ≤ 1.0