You are on page 1of 6

CURTAIN WALL W1-D1

DESIGN MODEL
DESIGN LOAD

DL: GLASS PANEL: 2500 kg/m3

WL. :WIND LOAD: 80 kg/m2


DESIGN GLASS PANEL
DISPLACEMENT LOAD CASE : DL+WL. (WALL PANEL)

DISPLACEMENT LOAD CASE : DL+WL. (RIB PANEL)


GLASS PANEL STRESS LOAD CASE : DL+WL (WALL PANEL)

Glass Type: Annealed Glass

Panel Size: 0.90 m x 6.63 m.

Supporting Method: Two sides supported by silicone

Thickness of Glass: 6 + 6 mm.

Refer to graphical result,


Maximum Stress; σmax. = 62.3 Ksc. (DL+WL combination)

Allowable Stress; σall. = 252.5 Ksc. (refer to AS1288-06 T. B1 Ultimate limit state design stress@At edge)

HENCE σmax < σall ……………….PASS

Maximum Deflection; Δ max = 6.73 mm.

Allowable Deflection; Δ all = 6630/90 = 73.66 mm. or max 20.00mm.

HENCE Δ max < Δ all ……………….PASS


GLASS PANEL STRESS LOAD CASE : DL+WL (RIB PANEL)

Glass Type: Tempered Glass

Panel Size: 0.25 m x 6.63 m.

Supporting Method: Two sides supported

Thickness of Glass: 10 + 10 mm.

Refer to graphical result,


Maximum Stress; σmax. = 103.0 Ksc. (DL+WL combination)

Allowable Stress; σall. = 631.30 Ksc. (refer to AS1288-06 T. B1 Ultimate limit state design stress@At edge)

HENCE σmax < σall ……………….PASS

Maximum Deflection; Δ max = 6.33 mm.

Allowable Deflection; Δ all = 6630/90 = 73.66 mm. or max 20.0mm.

HENCE Δ max < Δ all ……………….PASS

You might also like