Professional Documents
Culture Documents
Development Length
Check
(Safe)
Column Size
350 mm x 350 mm
Characteristic Load 800 KN
ABP 200 KN/m2
Concrete M20
Steel Fe415
Bar dia in column 16 no. of bar in column 8
Result
Footing Size 2.1 mx 2.1 m
Depth Required 398 mm Depth Provided 600 mm Depth at edge of footing
Bar Dia provided 12 no. of Bar 12 in both direction
Net Upward Pressure (safe) spacing 89 mm c/c
Development Length
Check (Safe)
One way shear Check ( safe)
Two way shear Check (Safe)
Cracking ( clear distance
between bar ) Check
( Safe)
Weight of Footing ( Safe)
Dowel length in Footing 1050 mm
Dowel area in column 612.5 mm2 (Safe)
Dowel Length in Column 628 mm
Design of Isolated rectangular ( Axially loaded ) sloped footing
Column Size 300 mm x 350 mm
Characteristic Load 130 KN (Unfactored)
ABP 210 KN/m2
Concrete M20
Steel Fe415
Bar dia in column 12 no. of bar in column 6 Concrete M20
Result
Footing Size required 0.80 mx 0.85 m
Footing Size Provided 0.85 mx 0.9 m
Depth Required 81 mm Depth Provided 450 mm Depth at edge of footing
Bar Dia provided 12 no. of Bar 4 parallel to longer direction (lower level )
Bar Dia provided 12 no. of Bar 4 parallel to shorter direction ( upper level)
Net Upward Pressure (safe) (change size of footing for safe Design by increase column load)
( change
Development Length
footing (increase length of bar by bend it 90 degree on side and top respectively for safe Desi
Check
size) footing size so length of bar increase or by decrease bar dia so required d
One way shear Check (Safe) @ x direction (Safe) @ y direction (change depth of footing for s
Two way shear Check (Safe) (change depth of footing for s
top respectively for safe Design or by increase column load for increase
decrease bar dia so required development length decrease )
(change depth of footing for safe Design )
(change depth of footing for safe Design )
oting