You are on page 1of 2

9

9.4
Parameter setting
Parameter setting with the XT EMZ9371BC keypad
9.4.5 Transfer parameters to other controllers

9.4.5 Transfer parameters to other controllers


The keypad enables you to easily copy parameter settings from one controller to
another.
For this purpose use the menu 7 ”Param managm”:

Copying parameter sets from the Step Keys Action


controller to the keypad 1. Connect the keypad to controller 1
2. Inhibit controller S The drive is idling
3. Select the submenu 7.1 ”Load/Store” z y Z Y Change to the submenu ”Load/Store” with the arrow
in the menu 7 ”Param managm” keys
4. Change to the code level Z Display C0002 ”Param managm”
5. Change to parameter level V Display ”0” and ”READY”
6. Select the correct copy function The settings stored in the keypad are overwritten.
• Copying all parameter sets available (PAR1 ... PAR4, ggf. FPAR1) to the keypad:
– Controller with function module z Copy PAR1 ... PAR4 und FPAR1:
application I/O, INTERBUS, ð Set ”80” ”F1&PAR1-4->Key”
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
– Controller with all other function Copy PAR1 ... PAR4:
modules ð Set ”20” ”PAR1-4->Keypad”
• Copying only the module-specific parameter set FPAR1 to the keypad:
– Only possible for controllers with z Copy FPAR1:
function module INTERBUS, ð Set ”50” ”FPAR1->Keypad”
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen:
7. Start copying TV The selected parameter sets are copied to the
keypad.
”SAVING...” is indicated.
If ”SAVING...” stops, the copy process is completed.
8. Change to the code level
A) V Display of operation level
B) V Display C0002 ”Param managm”
9. Enable the controller. U The drive should be running again
10. Remove the keypad from the
controller 1

9.4-6 EDS82EV903-1.0-11/2002 L
Parameter setting
Parameter setting with the XT EMZ9371BC keypad
9 9.4
Transfer parameters to other controllers 9.4.5

Copying parameter sets from the Step Keys Action


keypad to the controller 1. Connect keypad to controller 2
2. Inhibit controller S The drive is idling
3. Select the submenu 7.1 ”Load/Store” zyZY Change to the submenu ”Load/Store” with the arrow
in the menu 7 ”Param managm” keys
4. Change to the code level Z Display C0002 ”Param managm”
5. Change to parameter level V Display ”0” and ”READY”
6. Select the correct copy function The settings stored in the controller or in the function
module are overwritten.
• Copying all parameter sets available (PAR1 ... PAR4, ggf. FPAR1) to the controller:
– Controller with function module z Copy PAR1 ... PAR4 und FPAR1:
application I/O, INTERBUS, ð Set ”70” ”Key->F1&PAR1-4”
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
– Controller with all other function Copy PAR1 ... PAR4:
modules ð Set ”10” ”Keypad->PAR1-4”
• Copying single parameter sets (PARx und ggf. FPAR1) to the controller:
– Controller with function module z Copy PAR1 and FPAR1:
application I/O, INTERBUS, ð Set ”71” ”Key->FP1&PAR1”
PROFIBUS-DP, LECOM-B, Copy PAR2 and FPAR1:
DeviceNet/CANopen ð Set ”72” ”Key->FP1&PAR2”
Copy PAR3 and FPAR1:
ðSet ”73” ”Key->FP1&PAR3”
Copy PAR4 and FPAR1:
ðSet ”74” ”Key->FP1&PAR4”
– Controller with all other function Copy PAR1:
modules or controller without ð Set ”11” ”Keypad->PAR1”
function module Copy PAR2:
ð Set ”12” ”Keypad->PAR2”
Copy PAR3:
ð Set ”13” ”Keypad->PAR3”
Copy PAR4:
ð Set ”14” ”Keypad->PAR4”
• Copying only the module-specific parameter set FPAR1 to the function module:
– Only possible for controllers with z Copy FPAR1:
function module INTERBUS, ð Set ”40” ”Keypad->FPAR1”
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen:
7. Start copying TV The selected parameter sets are copied to the
controller or the function module.
”LOADING...” is indicated.
If ”LOADING...” stops, the copy process is completed.
8. Change to the code level
A) V Display of operation level
B) V Display C0002 ”Param managm”
9. Enable the controller. U The drive should be running again

L EDS82EV903-1.0-11/2002 9.4-7