You are on page 1of 3

DATOS

V2:
Cubierta: IPN 200…………………….26,2kg/m
• Cielorraso: 50kg/m2 Dc:.........…………380kg/m2 . 3,42m
• Losa preten. 155kg/m2
Lc:........................100kg/m2 . 3,42m
• Contrapiso 112kg/m2 Sobrecarga Dv:............1299,6kg/m
• Carpeta 63kg/m2 + 26,2kg/m
Vigas: Dv:............1325,8kg/m
• IPN 200 26,2kg/m2 Lv:.................342kg/m
Muro:
• Ladrillo hueco cerámico portante C. de servicio q:............1667,8kg/m
(mamp. con revoque) 1200kg/m3
Columnas:
• IPN 200 26,2kg/m2IPN 200 26,2kg/m2

Cubierta:
Cielorraso:.........................50kg/m2 V3
Losa preten……………….155kg/m2 IPN 200…………………….26,2kg/m
Contrapiso………………...112kg/m2 Dc:.........…………380kg/m2 . 1,71m
Carpeta……………………63kg/m2 Lc:........................100kg/m2 . 1,71m
Sobrecarga Dc:.........….380kg/m2 Sobrecarga Dv:.........…….650kg/m
Lc:..............100kg/m2 + 26,2kg/m
Dv:..............676,2kg/m
C. de servicio q:..............480kg/m2
Lv:.................171kg/m

Vigas: C. de servicio q:.............847,2kg/m

V1
IPN 200…………………….26,2kg/m
Dc:.........…………380kg/m2 . 1,71m
Lc:........................100kg/m2 . 1,71m

Sobrecarga Dv:.........…….650kg/m
+ 26,2kg/m
Dv:..............676,2kg/m
Lv:..................171kg/m

C. de servicio q:...............847,2kg/m
Muro:
M1
Mamp…....1200kg/m3 . 0,22m . 4,7m
Dv:.........…………380kg/m2 . 1,71m
Lv:........................100kg/m2 . 1,71m

Sobrecarga Dm:.........…….650kg/m M2:


+ 1108,8kg/m Mamp…....1200kg/m3 . 0,22m . 4,2m
Dv:.........…………380kg/m2 . 1,71m
Dm:............1758,8kg/m Lv:........................100kg/m2 . 1,71m
Lm:.................171kg/m
Sobrecarga Dm:.........…….650kg/m
C. de servicio q:............1929,8kg/m + 1108,8kg/m
Dm:...........1758,8kg/m
Lm:.................171kg/m

C. de servicio q:............1929,8kg/m

Columnas:
C2:
IPN 200…………….26,2kg/m . 4,2m
Tanque: Dv1:...........……...676,2kg/m . 1,71m
PC2:.......……………..500kg . 1,71m Lv1:.........................171kg/m . 1,71m
……........………………………4,49m Dv2:...........….....1325,8kg/m . 1,71m
PC3:.......……………..500kg . 2,77m Lv2:.........................342kg/m . 1,71m
……........………………………4,49m
Sobrecarga Dcv1:.....………1156kg
PC2:.......……………………191,53kg + 110kg
PC3:.......…………………...308,46kg Dcv2:...............2983kg
Descarga directa en C3……...500kg Tanque de agua…………...191,53kg
Lcv1:..............292,4kg
PC2:.......……………………191,53kg Lcv2:.................765kg
PC3:.......…………………....808,46kg
Sobrecarga Dc:.....……..4440,53kg
Lc:.................1057,4kg
C1:
IPN 200…………….26,2kg/m . 4,2m
Dv1:...........……...676,2kg/m . 1,71m C. de servicio q:................5497,9kg
Lv1:.........................171kg/m . 1,71m

Sobrecarga Dc:.........…..1149,54kg
+ 110kg
Dc:.................1259,5kg
Lc:..................292,4kg
C3:
C. de servicio q:.............1550,24kg IPN 200….………....26,2kg/m . 4,2m
Dv2:...........…….1325,8kg/m . 2,25m
Lv2:.........................342kg/m . 2,25m
Dv3:...........…......676,2kg/m . 1,85m
Lv3:........................171kg/m . 1,85m

Sobrecarga Dcv2:.....………2983kg
C4: + 110kg
IPN 200…………….26,2kg/m . 4,2m Dcv3:............1250,6kg
Dv3:...........……...676,2kg/m . 1,85m Tanque de agua…………...808,46kg
Lv3:.........................171kg/m . 1,85m Lcv2:.................765kg
Lcv3:..............316,3kg
Sobrecarga Dc:............…1250,6kg
+ 110kg Sobrecarga Dc:.....…………5152kg
Dc:................1360,6kg Lc:.................1081,3kg
Lc:...................316,3kg
C. de servicio q:................6233,3kg
C. de servicio q:.................1676,9kg
Bases aisladas HºAº:

B1: B2:
Vol…………..0,60m . 0,60m . 0,30m Vol…………..0,70m . 0,70m . 0,30m
………………………………0,108m3 …………………………...….0,147m3
BHºAº………..2400kg/m3 . 0,108m3 BHºAº………..2400kg/m3 . 0,147m3
Sobrecarga BHºAº....……...259,2kg Sobrecarga BHºAº....……...352,8kg
qC1:............1550,24kg qC2:..............5497,9kg

C. de servicio q:..............1809,44kg C. de servicio q:................5850,7kg


Verificación 1809,44kg / 3600cm2 Verificación 5850,7kg / 4900cm2
0,5kg/cm2………<............1,5kg/cm2 1,19kg/cm2…...…<...........1,5kg/cm2

B4: B3:
Vol…………..0,60m . 0,60m . 0,30m Vol…………..0,70m . 0,70m . 0,30m
………………………………0,108m3 …………………………...….0,147m3
BHºAº………..2400kg/m3 . 0,108m3 BHºAº………..2400kg/m3 . 0,147m3
Sobrecarga BHºAº....……...259,2kg Sobrecarga BHºAº....……...352,8kg
qC4:..............1676,9kg qC3:..............6233,3kg

C. de servicio q:................1936,1kg C. de servicio q:................6586,1kg


Verificación 1936,1kg / 3600cm2 Verificación 6586,1kg / 4900cm2
0,53kg/cm2..……<............1,5kg/cm2 1,34kg/cm2…...…<...........1,5kg/cm2

Zapata corrida HºAº:

Z1=Z2:
b………………………………...0,60m
ZHºAº……………..1929,8kg/m3 . 1m
Verificación 1929,8kg / 6000cm2
0,32kg/cm2………<..........1,5kg/cm2