Professional Documents
Culture Documents
datasheets
Description: Revision:
Company Address
The Netherlands
(Headquarters and manufacturing facility)
Thermo Electric
P.O. Box 79
2741 PH Waddinxveen
Telephone: +31 - (0)182 – 302 850
Fax : +31 - (0)182 – 302 777
E-mail : info@thermo-electric.nl
Descriptions: Issues:
x Industrial temperature sensors with screwed bar stock thermowell A/110 Rev.00 08/03
x Industrial temperature sensors with flanged bar stock thermowell A/115 Rev.00 05/03
x Industrial temperature sensors DIN type, screwed bar stock thermowell A/120 Rev.00 08/03
x Industrial temperature sensors DIN type, flanged bar stock thermowell A/125 Rev.00 08/03
x Industrial temperature sensors with tube type thermowell A/140 Rev.00 08/03
x Industrial temperature sensors with Ceramic thermowell A/145 Rev.00 08/03
x Mi-cable thermocouple inserts with Thermo Electric springloading A/210 Rev.00 08/03
x Mi-cable thermocouple inserts with DIN springloading A/215 Rev.00 08/03
x Resistance thermocouple inserts 400°C, Thermo Electric springloading A/220 Rev.00 08/03
x Resistance thermocouple inserts 550°C, Thermo Electric springloading A/225 Rev.00 08/03
x Transmitter integrated temperature sensors with RTD input A/250 Rev.00 08/03
x Transmitter integrated temperature sensors with t/c input A/255 Rev.00 08/03
x Screwed bar stock thermowells with parallel stem A/410 Rev.00 08/03
x Screwed bar stock thermowells with tapered stem A/415 Rev.00 08/03
x Flanged bar stock thermowells with parallel stem A/420 Rev.00 08/03
x Flanged bar stock thermowells with tapered stem A/425 Rev.00 08/03
x Tube skin thermocouples with connection head assembly A/510 Rev.00 08/03
x Tube skin thermocouples with lead wire A/515 Rev.00 08/03
x Multipoint thermocouple assemblies, bendable, spring loaded construction A/710 Rev.00 08/03
x Multipoint thermocouples, other typical designs A/715 Rev.00 08/03
Specifications:
Series : XPS-10.000
CONNECTION HEAD
Type : weatherproof with screw on cover
Material : cast-aluminium or cast-iron
Conduit entry thread : 3/4" NPT standard; if 1/2" NPT, BSP,
or metric thread, please specify
EXTENSION
Type : nipple-union-nipple
Material : galvanized carbon steel
Length : approx. 160 mm; other lengths optional
Process connection : 1/2" NPT, male thread
INSERT
Type : EEx e approved thermocouple or resistance
thermometer (see reverse side)
Insertion length below nipple : to be specified; replace box behind ordering
code
Insert length : A + 232 mm
THERMOWELL
Type : any type of thermowell; to be specified
separately
APPROVAL
Classification : EEx e II T5, CE0344 Ex II 2G
Certificate number : KEMA 03ATEX 2244X
Protection category : 'e' increased safety
Explosion group : II
Temperature class : T5
Applicable standards : EN-50014
EN-50019
The cable gland shall be a certified model and is not part of the approval
Ordering code:
CAST-ALUMINIUM HEAD CAST- IRON HEAD
Probe type Single Duplex Single Duplex
J 4,8 mm XPS-15101- J - mm XPS-16101- J - mm XPS-15201- J - mm XPS-16201- J - mm
K 4,8 mm XPS-15101- K - mm XPS-16101- K - mm XPS-15201- K - mm XPS-16201- K - mm
T 4,8 mm XPS-15101- T - mm XPS-16101- T - mm XPS-15201- T - mm XPS-16201- T - mm
Pt 100 6,0 mm XPS-15101- Pt100 - mm XPS-16101- Pt100 - mm XPS-15201- Pt100 - mm XPS-16201- Pt100 - mm
Specifications:
THERMOCOUPLE
Type : iron-constantan, type J
chromel-alumel, type K
copper-constantan, type T
Standard limits of error : ANSI MC 96.1 / IEC 584
Sheath material : SS 316 for type J and T (Wstnr.1.4401);
Inconel 600 for type K (Wstnr.2.4816)
Hot junction : insulated, individually insulated for duplex
Probe diameter : 4,8 mm
RESISTANCE THERMOMETER
Element type : Pt 100, single or duplex
Resistance values and tolerances : IEC 751 class B
Max. voltage : 5 V (10 mA)
Wiring system : 3 wires from element
Probe diameter : 6 mm
Ordering code:
Probe type Single Duplex
‘A’ ‘A’
J 4,8 mm TEE-50482- J - mm TEE-52484- J - mm
K 4,8 mm TEE-50482- K - mm TEE-52484- K - mm
T 4,8 mm TEE-50482- T - mm TEE-52484- T - mm
Pt 100 6,0 mm RTD-50603- Pt100 - mm RTD-52606- Pt100 - mm
Specifications:
Series : XPS-20.000
CONNECTION HEAD
Type : weatherproof with screw on cover
Material : cast-aluminium or cast-iron
Conduit entry thread : 3/4" NPT standard; if 1/2" NPT, BSP,
or metric thread, please specify
EXTENSION
Type : nipple-union-nipple
Material : galvanized carbon steel
Length : approx. 160 mm; other lengths optional
Process connection : 1/2" NPT, male thread
INSERT
Type : EEx ia approved thermocouple or
resistance thermometer (see reverse side)
Insertion length below nipple : to be specified; replace box behind
ordering code
Insert length : A + 232 mm
THERMOWELL
Type : any type of thermowell; to be
specified separately
APPROVAL
Classification : EEx ia IIC T4-T6 , CE 0344 Ex II 2G
Certificate number : KEMA 03ATEX 1245X
Protection category : 'ia' intrinsic safety, category a
Explosion group : IIC
Temperature class : T4-T6
Applicable standards : EN-50014
EN-50020
The cable gland shall be a certified model and is not part of the approval
Ordering code:
CAST-ALUMINIUM HEAD CAST-IRON HEAD
Probe type Single Duplex Single Duplex
J 4,8 mm XPS-25101- J - mm XPS-26101- J - mm XPS-25201- J - mm XPS-26201- J - mm
K 4,8 mm XPS-25101- K - mm XPS-26101- K - mm XPS-25201- K - mm XPS-26201- K - mm
T 4,8 mm XPS-25101- T - mm XPS-26101- T - mm XPS-25201- T - mm XPS-26201- T - mm
Pt 100 6,0 mm XPS-25101- Pt100 - mm XPS-26101- Pt100- mm XPS-25201- Pt100 - mm XPS-26201- Pt100 - mm
Specifications:
THERMOCOUPLE
Type : iron-constantan, type J
chromel-alumel, type K
copper-constantan, type T
Standard limits of error : ANSI MC 96.1 / IEC 584
Sheath material : SS 316 for type J and T (Wstnr.1.4401);
Inconel 600 for type K (Wstnr.2.4816)
Hot junction : insulated, individually insulated for duplex
Probe diameter : 4,8 mm
RESISTANCE THERMOMETER
Element type : Pt 100, single or duplex
Resistance values and tolerances : IEC 751 class B
Max. voltage : 5 V (10 mA)
Wiring system : 3 wires from element
Probe diameter : 6 mm
Ordering code:
J 4,8 mm TEE-50482- J - mm TEE-52484- J - mm
K 4,8 mm TEE-50482- K - mm TEE-52484- K - mm
T 4,8 mm TEE-50482- T - mm TEE-52484- T - mm
Pt 100 6,0 mm RTD-50603- Pt100 - mm RTD-52606- Pt100 - mm
Specifications:
Series : XPS-30.000
CONNECTION HEAD
Type : weatherproof with screw on cover
Material : cast-aluminium
Max. temperature : 80 °C
Conduit entry thread : 3/4" NPT standard; if 1/2" NPT, BSP
or metric thread, please specify
EXTENSION
Type : adjustable nipple with locknut
Material : galvanized carbon steel
Length : approx. 175 mm; other lengths optional
Process connection : 1/2" NPT, male thread
INSERT
Type : EEx d approved thermocouple or resis-
tance thermometer (see reverse side)
Insertion length below nipple : to be specified; replace box behind
ordering code
Insert length : A + 252 mm
THERMOWELL
Type : any type of thermowell; to be specified
separately
APPROVAL
Classification : EEx d IIC T6 , CE 0344 Ex II 2G
Certificate number : KEMA 03ATEX 2243X
Protection category : 'd' flame proof enclosure
Explosion group : IIC
Temperature class : T6
Applicable standards : EN-50014
EN-50018
The cable gland shall be a certified model and is not part of the approval
Ordering code:
CAST-ALUMINIUM HEAD
Probe type Single Duplex
J 4,8 mm XPS-35103- J - mm XPS-36103- J - mm
K 4,8 mm XPS-35103- K - mm XPS-36103- K - mm
T 4,8 mm XPS-35103- T - mm XPS-36103- T - mm
Pt 100 6,0 mm XPS-35103- Pt100 - mm XPS-36103- Pt100 - mm
Specifications:
THERMOCOUPLE
Type : iron-constantan, type J
chromel-alumel, type K
copper-constantan, type T
Standard limits of error : ANSI MC 96.1 / IEC 584
Sheath material : SS 316 for type J and T (Wstnr.1.4401);
Inconel 600 for type K (Wstnr.2.4816)
Hot junction : insulated, individually insulated for duplex
Probe diameter : 4,8 mm
RESISTANCE THERMOMETER
Element type : Pt 100, single or duplex
Resistance values and tolerances : IEC 751 class B
Max. voltage : 5 V (10 mA)
Wiring system : 3 wires from element
Probe diameter : 6 mm
Ordering code:
Probe type Single Duplex
‘A’ ‘A’
J 4,8 mm TEE-60482- J - mm TEE-62484- J - mm
K 4,8 mm TEE-60482- K - mm TEE-62484- K - mm
T 4,8 mm TEE-60482- T - mm TEE-62484- T - mm
Pt 100 6,0 mm RTD-60603- Pt100 - mm RTD-62606- Pt100 - mm
Specifications:
Series : ITS-10.000
CONNECTION HEAD ASSEMBLY
Type : series TSA-10.000, weatherproof
Material : cast-aluminium
Conduit entry thread : 3/4" NPT standard; if 1/2" NPT, M 20
or PG 16 is required, please specify
Terminal block : ceramic with clamp type terminals
Extension : 1/2" galvanized nipple-union-nipple
length approx. 160 mm
INSERT
Thermocouple : series TEE-10.000 single or duplex
(probe diameter 4,8 mm or 6,0 mm)
Resistance thermometer : series RTD-10.000 single or duplex
3-wire system (max. operating
temperature 400 °C or 550 °C)
Insert length 'A' : for replacement insert add 265 mm
to 'U' length
For complete specification : see separate datasheets
THERMOWELL
Type : drilled bar stock type TWE-21702
Material : SS 316 (Wst.nr. 1.4401)
Bore : 7 mm
Hex size : 32 mm
Process connection : 3/4" NPT male thread
Stem size : tapered from round 22 mm to 19 mm
at the tip
Immersion length 'U' : to be specified; replace box in
ordering code with your required length
Total well length : 'U' plus 45 mm
Ordering code:
SINGLE DUPLEX
Probe type Complete assembly Replacement insert Complete assembly Replacement insert
‘U’ ‘A’ ‘U’ ‘A’
J 4,8 mm ITS-10122- J - mm TEE-10482- J - mm ITS-12122- J - mm TEE-12484- J - mm
J 6,0 mm ITS-13122- J - mm TEE-10602- J - mm ITS-14122- J - mm TEE-12604- J - mm
K 4,8 mm ITS-10122- K - mm TEE-10482- K - mm ITS-12122- K - mm TEE-12484- K - mm
K 6,0 mm ITS-13122- K - mm TEE-10602- K - mm ITS-14122- K - mm TEE-12604- K - mm
T 4,8 mm ITS-10122- T - mm TEE-10482- T - mm ITS-12122- T - mm TEE-12484- T - mm
T 6,0 mm ITS-13122- T - mm TEE-10602- T - mm ITS-14122- T - mm TEE-12604- T - mm
Pt 100 550 °C ITS-10122- Pt100 - mm RTD-10603- Pt100 - mm ITS-12122- Pt100 - mm RTD-12606- Pt100 - mm
Pt 100 400 °C ITS-15122- Pt100 - mm RTD-13603- Pt100 - mm ITS-16122- Pt100 - mm RTD-14606- Pt100 - mm
= immersion length ‘U’ in mm (to be specified)
Also available in inches
Specifications:
Series : ITS-10.000
CONNECTION HEAD ASSEMBLY
Type : series TSA-10.000 weatherproof
Material : cast-aluminium
Conduit entry thread : 3/4" NPT standard; if 1/2" NPT, M 20 or
PG 16 is required, please specify
Terminal block : ceramic with clamp type terminals
Extension : 1/2" galvanized nipple-union-nipple length
approx. 160 mm
INSERT
Thermocouple : series TEE-10.000 single or duplex
(probe diameter 4,8 mm or 6,0 mm)
Resistance thermometer : series RTD-10.000 single or duplex
3-wire system (max. operating
temperature 400 °C or 550 °C)
Insert length 'A' : for replacement insert add 265 mm to 'U'
length; for ordering information see
overleaf
For complete specification : see separate datasheets
THERMOWELL
Type : drilled bar stock with flange type TWE-
23702
Material : SS 316 (Wst.nr. 1.4401)
Bore : 7 mm
Bar stock diameter : 32 mm
Flange size, rating and material : to be specified
Stem size : tapered from round 22 mm to 19 mm at
the tip
Immersion length 'U' : to be specified; replace box in ordering
code with your required length
Total well length : 'U' plus 50 mm
Ordering code:
SINGLE DUPLEX
Probe type Complete assembly Complete assembly
‘U’ Flange ‘U’ Flange
J 4,8 mm ITS-10162- J - mm- ITS-12162- J - mm-
J 6,0 mm ITS-13162- J - mm- ITS-14162- J - mm-
K 4,8 mm ITS-10162- K - mm- ITS-12162- K - mm-
K 6,0 mm ITS-13162- K - mm- ITS-14162- K - mm-
T 4,8 mm ITS-10162- T - mm- ITS-12162- T - mm-
T 6,0 mm ITS-13162- T - mm- ITS-14162- T - mm-
Pt 100 6.0 mm 550 °C ITS-10162- Pt100 - mm- ITS-12162- Pt100 - mm-
Pt 100 6.0 mm 400 °C ITS-15162- Pt100 - mm- ITS-16162- Pt100 - mm-
= immersion length ‘U’ in mm and flange (to be specified) Also available in inches
Specifications:
Series : ITS-20.000
CONNECTION HEAD ASSEMBLY
Type : series TSA-20.000
Material : cast-aluminium
Conduit entry : PG 16 cable gland
Extension : galvanized nipple with gland nut for head
adjustment; length approx. 75 mm
INSERT
Thermocouple : series TEE-20.000 single or duplex
(probe diameter 4,8 mm or 6,0 mm)
Resistance thermometer : series RTD-20.000 single or duplex
3-wire system (max. operating
temperature 400 °C or 550 °C)
Insert length 'A' : for replacement insert add 145 mm to 'U'
length
For complete specification : see separate datasheets
THERMOWELL
Type : drilled bar stock type TWE-21702
Material : SS 316 (Wst.nr. 1.4401)
Bore : 7 mm
Hex size : 32 mm
Process connection : 3/4" NPT male thread
Stem size : tapered from round 22 mm to 19 mm at
the tip
Immersion length 'U' : to be specified; replace box in ordering
code with your required length
Total well length : 'U' plus 45 mm
Ordering code:
SINGLE DUPLEX
Probe type Complete assembly Replacement insert Complete assembly Replacement insert
‘U’ ‘A’ ‘U’ ‘A’
J 4,8 mm ITS-20522- J - mm TEE-20482- J - mm ITS-22522- J - mm TEE-22484- J - mm
J 6,0 mm ITS-23522- J - mm TEE-20602- J - mm ITS-24522- J - mm TEE-22604- J - mm
K 4,8 mm ITS-20522- K - mm TEE-20482- K - mm ITS-22522- K - mm TEE-22484- K - mm
K 6,0 mm ITS-23522- K - mm TEE-20602- K - mm ITS-24522- K - mm TEE-22604- K - mm
T 4,8 mm ITS-20522- T - mm TEE-20482- T - mm ITS-22522- T - mm TEE-22484- T - mm
T 6,0 mm ITS-23522- T - mm TEE-20602- T - mm ITS-24522- T - mm TEE-22604- T - mm
Pt 100 550 °C ITS-20522- Pt100 - mm RTD-20603- Pt100 - mm ITS-22522- Pt100 - mm RTD-22606- Pt100 - mm
Pt 100 400 °C ITS-25522- Pt100 - mm RTD-23603- Pt100 - mm ITS-26522- Pt100 - mm RTD-24606- Pt100 - mm
Specifications:
Series : ITS-20.000
CONNECTION HEAD ASSEMBLY
Type : series TSA-20.000
Material : cast-aluminium
Conduit entry : PG 16 cable gland
Extension : galvanized nipple with gland nut for head
adjustment; length approx. 75 mm
INSERT
Thermocouple : series TEE-20.000 single or duplex (probe
diameter 4,8 mm or 6,0 mm)
Resistance thermometer : series RTD-20.000 single or duplex
3-wire system (max. operating
temperature 400 °C or 550 °C)
Insert length 'A' : for replacement insert add 145 mm to 'U'
length
For complete specification : see separate datasheets
THERMOWELL
Type : drilled bar stock with flange type TWE-23702
Material : SS 316 (Wst.nr. 1.4401)
Bore : 7 mm
Bar stock diameter : 32 mm
Flange size, rating and material : to be specified
Stem size : tapered from round 22 mm to 19 mm at
the tip
Immersion length 'U' : to be specified; replace box in ordering
code with your required length
Total well length : 'U' plus 50 mm
Ordering code:
SINGLE DUPLEX
Probe type Complete assembly Complete assembly
‘U’ Flange ‘U’ Flange
J 4,8 mm ITS-20562- J - mm- ITS-22562- J - mm-
J 6,0 mm ITS-23562- J - mm- ITS-24562- J - mm-
K 4,8 mm ITS-20562- K - mm- ITS-22562- K - mm-
K 6,0 mm ITS-23562- K - mm- ITS-24562- K - mm-
T 4,8 mm ITS-20562- T - mm- ITS-22562- T - mm-
T 6,0 mm ITS-23562- T - mm- ITS-24562- T - mm-
Pt 100 6.0 mm 550 °C ITS-20562- Pt100 - mm- ITS-22562- Pt100 - mm-
Pt 100 6.0 mm 400 °C ITS-25562- Pt100 - mm- ITS-26562- Pt100 - mm-
Specifications:
Series : ITS-80.000
CONNECTION HEAD ASSEMBLY
Type : swing cover head with SS set screw
and neoprene ‘O’ ring
Material : cast-aluminium
Conduit entry : PG 16 cable gland
Cable diameter : 11,5 - 15,5 mm
INSERT
Thermocouple : series TEE-20.000 single or duplex
(probe diameter 6,0 mm)
Resistance thermometer : series RTD-20.000 single or duplex
3-wire system (max. operating
temperature 400 °C)
Insert length 'A' : for replacement insert add 40 mm to
'U' length
For complete specification : see datasheets A/210 and A/230
THERMOWELL
Type : tube type well, one end closed
Material : SS 316 (Wst.nr. 1.4401)
Outside diameter x wall thickness : 15 x 1,5 mm
Immersion length 'U' : to be specified; replace box in
ordering
code with your required length
OPTIONS
1) Adjustable flange, NW 15 DIN 43734
2) Adjustable mounting bush, G ½” (ISO R228)
Ordering code:
SINGLE DUPLEX
Probe type Complete assembly Replacement insert Complete assembly Replacement insert
‘U’ ‘A’ ‘U’ ‘A’
J ITS-83782- J - mm TEE-20602- J - mm ITS-84782- J - mm TEE-22644- J - mm
K ITS-83782- K - mm TEE-20602- K - mm ITS-84782- K - mm TEE-22604- K - mm
T ITS-83782- T - mm TEE-20602- T - mm ITS-84782- T - mm TEE-22604- T - mm
Pt 100 ITS-85782- Pt100 - mm RTD-23603- Pt100 - mm ITS-86782- Pt100 - mm RTD-24606- Pt100 - mm
Specifications:
Series : ITS-70.000
CONNECTION HEAD
Type : weatherproof, heavy duty head with
screw on cover
Material : zinc plated cast-iron
Conduit entry head : ¾” NPT, if ½” NPT, M 20 or PG 16 is
required, please specify
Terminal block : ceramic with clamp type terminals
INSERT
Type : beaded type thermocouple
Thermocouple type : chromel-alumel, type K
Pt 10% Rh/Pt, type S
Pt 13% Rh/Pt, type R
Standard limits of error : ANSI MC 96.1 / IEC 584
Wire size : 1,6 mm (14 AWG), type K
0,5 mm (24 AWG), type R and S
Insert length : ‘U’ plus 140 mm
THERMOWELL
Type : gas tight ceramic protection tube
cemented to mild steel extension tube
Material : aluminium oxide (AL2O3, 60% pure for
type K and 99,7% pure for type R and S)
Outside diameter x wall thickness : 15 x 2 mm
Extension tube diameter : 22 mm
Extension tube length : 150 mm
Immersion length 'U' : to be specified; replace box in ordering
code with your required length
OPTIONS
1) Adjustable flange, NW 22 DIN 43734
2) Adjustable mounting bush, G 1” (ISO R288)
SINGLE DUPLEX
Ordering code:
Calibration Complete assembly Complete assembly
‘U’ ‘U’
K ITS-77288- K - mm ITS-79288- K - mm
S ITS-77288- S - mm ITS-79288- S - mm
R ITS-77288- R - mm ITS-79288- R - mm
Specifications:
Series : TEE-10.000
Probe type : mineral insulated
Thermocouple type : iron-constantan, type J
chromel-alumel, type K
copper-constantan, type T
Standard limits of error : ANSI MC 96.1 / IEC 584
Probe diameter : 4,8 mm (3/16")
6,0 mm
Insulation material : densely packed MgO, 99,6% purity
Sheath material : SS 316 for type J and T
(Wstnr.1.4401)
and Inconel 600 for type K
(Wstnr.2.4816)
Hot junction : insulated, common insulated for
duplex
Min. insulation resistance : 10 Mohm at ambient temperature with
200 V DC
Termination : 100 mm PVC insulated flexible wire
Spring : high temperature resistant material
Max. springloading : up to 25 mm field adjustable by turning
the spring clockwise
Probe length 'A' : to be specified; add 265 mm to 'U'
length of series ITS-10.000 industrial
temperature sensors
These inserts fit standard head assemblies series TSA-10.000 and standard
industrial temperature sensors series ITS-10.000
Ordering code:
Single Duplex
Probe type
‘A’ ‘A’
J 4,8 mm TEE-10482- J - mm TEE-12484- J - mm
J 6,0 mm TEE-10602- J - mm TEE-12604- J - mm
K 4,8 mm TEE-10482- K - mm TEE-12484- K - mm
K 6,0 mm TEE-10602- K - mm TEE-12604- K - mm
T 4,8 mm TEE-10482- T - mm TEE-12484- T - mm
T 6,0 mm TEE-10602- T - mm TEE-12604- T - mm
Specifications:
Series : TEE-20.000
Probe type : mineral insulated
Thermocouple type : iron-constantan, type J
chromel-alumel, type K
copper-constantan, type T
Standard limits of error : ANSI MC 96.1 / IEC 584
Probe diameter : 4,8 mm (3/16")
6,0 mm
Insulation material : densely packed MgO, 99,6% purity
Sheath material : SS 316 for type J and T (Wstnr.1.4401) and
Inconel 600 for type K (Wstnr.2.4816)
Hot junction : insulated, common insulated for duplex
Min. insulation resistance : 10 Mohm at ambient temperature with 200 V
DC
Termination : ceramic DIN terminal block with clamp type
terminals; fitted by means of two M 4 screws
on 33 mm centres
Max. springloading : 10 mm
Probe length 'A' : to be specified; add 145 mm to 'U' length of
series ITS-20.000 industrial temperature
sensors
These inserts fit standard head assemblies series TSA-20.000 and standard industrial
temperature sensors series ITS-20.000
Ordering code:
J 4,8 mm TEE-20482- J - mm TEE-22484- J - mm
J 6,0 mm TEE-20602- J - mm TEE-22604- J - mm
K 4,8 mm TEE-20482- K - mm TEE-22484- K - mm
K 6,0 mm TEE-20602- K - mm TEE-22604- K - mm
T 4,8 mm TEE-20482- T - mm TEE-22484- T - mm
T 6,0 mm TEE-20602- T - mm TEE-22604- T - mm
= probe length ‘A’ in mm (to be specified)
Specifications:
Series : RTD-10.000
Probe type : sheathed construction
Temperature range : -50 °C to +400 °C
Element type : Pt 100, single or duplex
Resistance values and tolerances : IEC 751, class B
Nominal resistance : 100 Ohm ± 0,1 at 0 °C
Nominal temperature coefficient : 0,00385
Recommended max. current : 10 mA
Min. insulation resistance : 10 Mohm at ambient temperature with
200 V DC
Wiring system : 2-, 3- or 4-wires
Inner lead resistance : negligible
Termination : 100 mm PVC insulated flexible wire
Spring : high temperature resistant material
Max. springloading : up to 25 mm field adjustable by
turning the spring clockwise
Sheath material : SS 316 (Wst.nr. 1.4401)
Probe diameter : 6,0 mm
Probe length 'A' : to be specified; add 265 mm to 'U'
length of series ITS-10.000 industrial
temperature sensors
These inserts fit standard head assemblies series TSA-10.000 and standard industrial
temperature sensors series ITS-10.000
Other ranges and/or classes for Pt100’s are available on request.
Ordering code:
Specifications:
Series : RTD-10.000
Probe type : mineral insulated
Temperature range : -50 °C to +550 °C
Element type : Pt 100, single or duplex
Resistance values and tolerances : IEC 751, class B
Nominal resistance : 100 Ohm ± 0,1 at 0 °C
Nominal temperature coefficient : 0,00385
Recommended max. current : 10 mA
Min. insulation resistance : 10 Mohm at ambient temperature with 200 V
DC
Wiring system : 3- or 4-wires from the element
Termination : 100 mm PVC insulated flexible wire
Spring : high temperature resistant material
Max. springloading : up to 25 mm field adjustable by turning the
spring clockwise
Sheath material : SS 316 (Wst.nr. 1.4401)
Probe diameter : 6,0 mm
Probe length 'A' : to be specified; add 265 mm to 'U' length of
series ITS-10.000 industrial temperature
sensors
These inserts fit standard head assemblies series TSA-10.000 and standard industrial
temperature sensors series ITS-10.000
Other ranges and/or classes for Pt100’s are available on request.
Ordering code:
Specifications:
Series : RTD-20.000
200 V DC
M4 screws on 33 mm centres
Max. springloading : 10 mm
temperature sensors
These inserts fit standard head assemblies series TSA-20.000 and standard industrial
temperature sensors series ITS-20.000
Other ranges and/or classes for Pt100’s are available on request.
Ordering code:
Specifications:
Series : RTD-20.000
V DC
screws on 33 mm centres
Max. springloading : 10 mm
sensors
These inserts fit standard head assemblies series TSA-20.000 and standard industrial
temperature sensors series ITS-20.000
Ordering code:
Specifications:
Ordering code:
Specifications:
Ordering code:
Probe Single Duplex
Cal. ‘A’ Cal. ‘A’
3,0 mm TEE-15302 - - mm TEE-16304 - - mm
4,8 mm (3/16”) TEE-15482 - - mm TEE-16484 - - mm
6,0 mm TEE-15602 - - mm TEE-16604 - - mm
Specifications:
Series : XTM-20.000
Type : 2-wire transmitter with single
resistance thermometer element
Element type : Pt 100
Resistance values and tolerances : IEC 751, class B
Probe diameter : 6,0 mm
Sheath material : SS 316 (Wst.nr. 1.4401)
Temperature range : -50 °C to +400 °C; see below; other
ranges available on request
Output : 4 - 20 mA
Head temperature : -10 °C to +70 °C
Calibration accuracy : ± 0,1% of span
Power supply : 10 - 36 V DC polarity protected
Termination : terminal block with clamp type
terminals; fitted by means of two M 4
screws on 33 mm centres
Max. springloading : 10 mm
Probe length 'A' : to be specified; add 145 mm to 'U'
length of series ITS-20.000 industrial
temperature sensors
These inserts fit standard head assemblies series TSA-20.000 and standard
industrial temperature sensors series ITS-20.000;
more detailed information of transmitter, see datasheet A/260
For other element types, dimensions and/or use in explosive areas, please
contact our nearest sales office
Other ranges and/or classes for Pt100’s are available on request.
Ordering code:
Standard input range Ordering code
‘A’
50 °C to +50 °C XTM-21602-Pt100 - mm
0 °C to +100 °C XTM-22602-Pt100 - mm
0 °C to +200 °C XTM-23602-Pt100 - mm
0 °C to +300 °C XTM-24602-Pt100 - mm
0 °C to +400 °C XTM-25602-Pt100 - mm
Specifications:
Series : XTM-20.000
Type : 2-wire transmitter with single resistance
thermometer element
Thermocouple type : iron-constantan, type J
chromel-alumel, type K
copper-constantan, type T
Standard limits of error : ANSI MC 96.1 / IEC 584
Probe diameter : 6,0 mm
Sheath material : SS 316 for type J and T (Wstnr.1.4401)
and Inconel 600 for type K
(Wstnr.2.4816)
Hot junction : insulated
Cold junction compensation : 0 °C reference temperature
Temperature range : 0 °C to +1200 °C; see below, other
ranges available on required
Output : 4 - 20 mA
Head temperature : -10 °C to +70 °C
Calibration accuracy : ± 0,1% of span
Power supply : 10 - 36 V DC polarity protected
Termination : terminal block with clamp type terminals;
fitted by means of two M 4 screws on
33 mm centres
Max. springloading : 10 mm
Probe length 'A' : to be specified; add 145 mm to 'U' length
of series ITS-20.000 industrial
temperature sensors
These inserts fit standard head assemblies series TSA-20.000 and standard industrial
temperature sensors series ITS-20.000; more detailed information of transmitter, see
datasheet A/260
For other element types, dimensions and/or use in explosive areas, please contact our
nearest sales office
Ordering code:
Standard input range Iron-constantan Chromel-alumel Copper-constantan
‘A’ ‘A’ ‘A’
0 °C to +300 °C XTM-21602-J- mm XTM-21602-K- mm XTM-21602-T- mm
0 °C to +400 °C XTM-22602-J- mm XTM-22602-K- mm XTM-22602-T- mm
0 °C to +600 °C XTM-23602-J- mm XTM-23602-K- mm
0 °C to +800 °C XTM-24602-K- mm
0 °C to +1200 °C XTM-25602-K- mm
Features:
x Microprocessor based
x RTD, t/c, mV and Ohm input
(depending on type)
x Galvanic isolated optional
x Good accuracy
x RFI immunity
x Ex optional (Ex ia IIC T4/T6)
x Linear possibility
x Programmable
x Foundation Fieldbus / Profibus
Specifications:
Ordering code:
Dimensions:
20,2
Ranges:
Notes:
Pt100, 2-, 3- or 4-wire available Type 5333 is only available for a 2 and 3 wire system.
Type 5331A-3-A or B and 5331B-3-A or B. B is including galvanic isolation.
Namur NE43 classification
EMC EN 500081, and 52082 classifications
Vibration: IEC 68-2-6 test FC
Accessories:
Specifications:
Series : TSA-10.000
CONNECTION HEAD
Type : weatherproof, heavy duty head with
screw on cover
Material : cast-aluminium or zinc plated cast-iron
Conduit entry thread : ¾” NPT standard; if ½” NPT M20 or
PG 16 required, please specify
Cover : internally threaded with gasket;
stainless
steel chain to prevent loss
Terminal block : fixed ceramic block with clamp type
terminals to suit wiring system
EXTENSION
Cast aluminium head
Type : nipple-union-nipple / nipple with locknut
Nipples : galvanized carbon steel, ½” sched. 40
Union : galvanized malleable iron, ½” 150 lbs
Nut : galvanized carbon steel
Length : approx. 160 mm
Process connection : ½” NPT, male thread
These connection head assemblies fit all thermocouple inserts series TEE-10.000
and resistance thermometer inserts series RTD-10.000 with Thermo Electric spring
loading.
Ordering code:
Specifications:
Series : TSA-20.000
CONNECTION HEAD
Type : light weight connection head for spring
loaded inserts with DIN terminal block
Material : cast-aluminium or polyamide
Conduit entry thread : PG 16 cable gland
Cable diameter : 11,5 - 15,5 mm
EXTENSION
Type : nipple with M 24 x 1,5 mm head
connection for positioning the head
Nipples : galvanized carbon steel
Length : approx. 75 mm
Process connection : 1/2" NPT
Cast aluminium head
These connection head assemblies fit all thermocouple inserts series TEE-20.000
and resistance thermometer inserts series RTD-20.000 with DIN spring loaded
terminal block.
BUZ head
Ordering code:
Specifications:
Series : TWE-10.000
stock
36 mm (1" NPT)
+0,5
Stem diameter : 19 mm -0
Test wells can be supplied with brass or stainless steel plug and chain; please
specify when ordering.
Ordering code:
Specifications:
Series : TWE-20.000
stock
36 mm (1" NPT)
Test wells can be supplied with brass or stainless steel plug and chain; please
specify when ordering.
Ordering code:
Process connection Bore ø SS 304 SS 316
‘U’ ‘U’
3/4" NPT 7 mm TWE-21701 - mm TWE-21702 - mm
3/4" NPT 10 mm TWE-21011 - mm TWE-21012 - mm
1" NPT 7 mm TWE-22701 - mm TWE-22702 - mm
1" NPT 10 mm TWE-22011 - mm TWE-22012 - mm
Specifications:
Series : TWE-13.000
Test wells can be supplied with brass or stainless steel plug and chain; please specify
when ordering.
Ordering code:
Specifications:
Series : TWE-23.000
Test wells can be supplied with brass or stainless steel plug and chain; please specify
when ordering.
Ordering code:
Specifications:
Series : TUS-10.000
CONNECTION HEAD
Type : weatherproof connection head with screw
on cover
Material : cast-iron, zinc-plated
Conduit entry : 3/4" NPT standard; if 1/2" NPT, M 20 or
PG 16 is required, please specify
Cover : internally threaded with gasket and SS
retaining chain
Terminal block : fixed ceramic block with clamp type
terminals
EXTENSION
Type : nipple-union-nipple with SS compression
fitting inside the union
Nipples : galvanized carbon steel 1" sched. 40
Union : galvanized malleable iron 150 lbs
Extension length : approx. 210 mm
Process connection : 1" NPT male thread; if other size
required, please specify
THERMOCOUPLE
Probe type : mineral insulated (MgO)
Thermocouple type : Chromel-alumel, type K
Standard limits of error : ANSI MC 96.1 / IEC 584
Sheath material : SS 310 or Hastelloy X
Outside diameter : 4,8 mm (3/16")
Hot junction : insulated
Probe length 'L' incl. expansion loop : to be specified; replace box 'L' in ordering
code
Weld pad dimensions : 25 x 25 x 3,2 mm
Mounting method : longitudinal or right angle mounted on
furnace tube
Furnace tube o.d. : to be specified; replace box 'D' in ordering
code (minimum 50 mm)
Weld pad material : same as sheath material
Weld clamps : one clamp will be supplied with each
assembly, material same as sheath
material; extra clamps to be ordered
separately; see below
Ordering code:
Specifications:
Series : TUS-20.000
Probe type : mineral insulated (MgO) thermocouple,
welded to a weld pad
Thermocouple type : Chromel-alumel, type K
Standard limits of error : ANSI MC 96.1 / IEC 584
Probe diameter : 6,0 mm
Insulation material : densely packed MgO, 99,6% purity
Sheath material : SS 310 or Hastelloy X
Hot junction : insulated
Min. insulation resistance : 10 Mohm at ambient temperature with 200
V DC
Probe length 'A' : to be specified; replace box 'A' in ordering
code
Lead wire : glass fibre insulated thermocouple wire
with SS braiding (type G/GS); positive wire
identified with polarity mark
Length lead wire : 1000 mm
Upper temperature limit lead wire : 500 °C
Max. temperature transition : 200 °C
Weld pad dimensions : 25 x 25 x 3,2 mm
Mounting method : longitudinal or right angle mounted on
furnace tube (see drawing overleaf)
Furnace tube o.d. : to be specified; replace box 'D' in ordering
code (minimum 50 mm)
Weld pad material : same as sheath material
Weld clamps : one clamp will be supplied with each
assembly, material same as sheath
material; extra clamps to be ordered
separately; see below
Ordering code:
= probe length ‘A’ and furnace tube o.d. ‘D’ in mm (to be specified)
Specifications:
CONNECTION BOX
Type : weatherproof or explosion proof type
Material : cast-aluminium
Dimensions : dependent on number of terminals
Conduit entries : specify diameter of holes and quantity
Terminals : rail mounted terminal blocks with
thermocouple material contact bars
Number of terminals : two for each thermocouple, extra ground
terminals (brass) to be specified if
required
Max. temperature : 80 °C (other ratings available)
EXTENSION
Type : nipple-union-nipple
Nipples : galvanized carbon steel
Union : galvanized malleable iron
Length : to be specified
Process connection : flanged; material, rating and size to be
specified
MULTICOUPLE INSET
Construction : mineral insulated (MgO), metal sheathed
thermocouples fixed to flexible st. steel
support strip; thermocouple tip fixed on
spring to provide contact with inner wall
of thermowell
Position (X) of measuring points : to be specified
Calibration : all standard types
Thermocouple o.d. : 3,2 mm
Hot junction : grounded or insulated
Spring material : Inconel
Total strip length : 'Xn' + 150 mm
Nominal thermowell i.d.
(quantity of measuring points) : I 20 mm (up to 4 points)
I 25 mm (up to 8 points)
I 40 mm (up to 12 points)
I 50 mm (up to 20 points)
Contact your nearest Thermo Electric office or representative for full specification
suitable for your application. Thermo Electric is capable to design various special
constructions on customer specification for each application.
Multi point temperature sensors are also available in explosion proof constructions
(ATEX approved).
Specifications:
Descriptions: Issues:
x Sub miniature Mi-cable thermocouples, direct mounted miniature plug B/200 Rev.00 08/03
x Sub miniature Mi-cable thermocouples, flexible lead wire B/205 Rev.00 08/03
x Miniature Mi-cable thermocouples, single with standard connector B/210 Rev.00 08/03
x Miniature Mi-cable thermocouples, single with miniature connector B/220 Rev.00 08/03
x Miniature Mi-cable thermocouples, single with SS braided lead wire B/230 Rev.00 08/03
x Miniature Mi-cable thermocouples, single with SS armoured lead wire B/311 Rev.00 08/03
x Miniature Mi-cable thermocouples, single with PVC insulated lead wire B/312 Rev.00 08/03
x Miniature Mi-cable thermocouples, single with Teflon insulated lead wire B/315 Rev.00 08/03
x Adjustable mounting bushings for miniature Mi-cable thermocouples B/410 Rev.00 08/03
x Adjustable spring loaded adapters for miniature Mi-cable thermocouples B/420 Rev.00 08/03
x Pipe clamp adapters for spring loaded thermocouples B/515 Rev.00 08/03
x Spring loaded thermocouple with adjustable bayonet cap B/520 Rev.00 08/03
x Spring loaded resistance elements with adjustable bayonet cap B/525 Rev.00 08/03
Hot junction
4
1 4 7
4
2 5 8
4 4
3 6 9
(4
reductions: 1Æ 0,5 - 1,5/1,6 Æ 1,0 - 2,0 Æ 1,0 - 3,0/3,2 Æ 1,6 - 4,8 Æ 3,2 - 6/6,4 Æ 3,2)
Wire type:
A P/TW : PVC insulated single F HF/D : Kapton insulated
B P/PTW : PVC insulated G Si/SiTW : Silicon insulated
C P/CuPTW : PVC insulated + copper braided H Flex. armour + TEX/TW: Flex. armour over Teflon insulated
D TEX/TW : Teflon insulated J G/G : Fibreglass insulated
E TEX/CuTEXTW : Teflon insulated + copper braided K G/GS : Fibreglass ins. + SS overall braiding
End termination
5
A K V
M
B L
D N
C P
E /
U
5
( For flexible armour only)
Options
6 7
A C E
B D
Because of the large number of possible combinations, some constructions will be subject to availability of materials and
technical feasibility. Please contact your nearest THERMO ELECTRIC office for confirmation. Other calibrations e.g. Tungsten/
Rhenium, diameters e.g. 8,0 mm, sheath materials e.g. Tantalum and special connectors (weather proof), sketch preferred.
Specifications:
Ordering code:
Specifications:
Ordering code:
Specifications:
Ordering code:
Specifications:
Ordering code:
Probe diameter Calibration J Calibration K Calibration T
‘A’ ‘A’ ‘A’
1,0 mm MTS-15101-J-MM MTS-15103-KMM MTS-15101-TMM
1,6 mm MTS-15161-J-MM MTS-15163-KMM MTS-15161-TMM
3,0 mm MTS-15301-J-MM MTS-15303-KMM MTS-15301-TMM
Specifications:
Ordering code:
Probe diameter Calibration J Calibration K Calibration T
‘A’ ‘B’ ‘A’ ‘B’ ‘A’ ‘B’
1,0 mm MTS-20101-JMM MTS-20103-KMM MTS-20101-TMM
1,6 mm MTS-20161-JMM MTS-20163-KMM MTS-20161-TMM
3,0 mm MTS-20301-JMM MTS-20303-KMM MTS-20301-TMM
4,8 mm MTS-20481-JMM MTS-20483-KMM MTS-20481-TMM
6,0 mm MTS-20601-JMM MTS-20603-KMM MTS-20601-TMM
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified)
Specifications:
200 V DC
Lead wire : Teflon insulated flexible thermocouple
wire covered with stainless steel flexible
armour; 200 mm unarmoured tails;
positive wire identified with polarity mark
Upper temperature limit for lead wire : 200 qC
Max. temperature transition : 200 qC
Probe length 'A' : to be specified; replace box in ordering
code with your required length
Lead wire length ‘B’ : to be specified; replace box in ordering
code with your required length
Ordering code:
Probe diameter Calibration J Calibration K Calibration T
‘A’ ‘B’ ‘A’ ‘B’ ‘A’ ‘B’
1,6 mm MTS-33161-JMM MTS-33163-KMM MTS-33161-TMM
3,0 mm MTS-33301-JMM MTS-33303-KMM MTS-33301-TMM
4,8 mm MTS-33481-JMM MTS-33483-KMM MTS-33481-TMM
6,0 mm MTS-33601-JMM MTS-33603-KMM MTS-33601-TMM
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified)
Specifications:
Ordering code:
Probe diameter Calibration J Calibration K Calibration T
‘A’ ‘B’ ‘A’ ‘B’ ‘A’ ‘B’
1,0 mm MTS-40101-JMM MTS-40103-KMM MTS-40101-TMM
1,6 mm MTS-40161-JMM MTS-40163-KMM MTS-40161-TMM
3,0 mm MTS-40301-JMM MTS-40303-KMM MTS-40301-TMM
4,8 mm MTS-40481-JMM MTS-40483-KMM MTS-40481-TMM
6,0 mm MTS-40601-JMM MTS-40603-KMM MTS-40601-TMM
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified)
Specifications:
200 V DC
Lead wire : Teflon insulated copper braided and
twisted flexible lead wire
(TEX/CUTEXTW); positive wire
identified
with polarity mark
Upper temperature limit for lead wire : 200 qC
Max. temperature transition : 200 qC
Probe length 'A' : to be specified; replace box in ordering
code with your required length
Lead wire length ‘B’ : to be specified; replace box in ordering
code with your required length
For accessories : see separate datasheet
Ordering code:
Probe diameter Calibration J Calibration K Calibration T
‘A’ ‘B’ ‘A’ ‘B’ ‘A’ ‘B’
1,0 mm MTS-50101-JMM MTS-50103-KMM MTS-50101-TMM
1,6 mm MTS-50161-JMM MTS-50163-KMM MTS-50161-TMM
3,0 mm MTS-50301-JMM MTS-50303-KMM MTS-50301-TMM
4,8 mm MTS-50481-JMM MTS-50483-KMM MTS-50481-TMM
6,0 mm MTS-50601-JMM MTS-50603-KMM MTS-50601-TMM
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified)
Specifications:
Ordering code:
Body material
Thermocouple o.d. Mounting thread Stainless steel Note Brass Note
1,0 mm 1/8" NPT MTS-90101 1 - -
1,6 mm 1/8" NPT MTS-90161 1/2 MTS-90165 1
1/4" NPT MTS-90162 1/2 MTS-90166 1
M 4 x 0,7 mm MTS-90164 - MTS-90167 -
3,0 mm 1/8" NPT MTS-90301 1/2 MTS-90305 1
1/4" NPT MTS-90302 1/2 MTS-90306 1
M 8 x 1,25 mm MTS-90303 - - -
4,8 mm 1/8" NPT MTS-90481 1/2 MTS-90485 1
1/4" NPT MTS-90482 1/2 MTS-90486 -
1/8" BSPT MTS-90483 - - -
6,0 mm M 12 x 1,5 mm MTS-90603 - MTS-90607 -
6,0 mm 1/8" NPT MTS-90601 1/2 MTS-90605 1
1/4" NPT MTS-90602 1/2 MTS-90606 1
M 18 x 1,5 mm MTS-90603 - MTS-90607 -
Note 1 : Teflon ferrule available, please specify; thermocouple can be relocated if used below 200qC
Note 2 : lava ferrule available, please specify; thermocouple can be relocated if ferrule is replaced
Specifications:
Adapter length : 90 mm
Ordering code:
Probe diameter Ferrule material Ordering code
1,6 mm brass MTS-91161
Teflon MTS-91162
3,0 mm brass MTS-91301
Teflon MTS-91302
Note : adapter can be relocated by using a Teflon ferrule if used below 200qC
Specifications:
Some types are also available in Mi-cable construction with insulated hot junction
(common insulated for duplex and Teflon insulated thermocouple wire inside flexible
armour)
Ordering code:
Ordering code:
Silver tip
‘B’
single MTS-60521 -mm
Straight, probe with lead wire and bare ends
‘B’
MTS-60531 -mm
single
Straight, probe with lead wire and standard plug
Information on immersion lengths, mounting and pipe clamp adapters for use with springloaded thermocouple, see datasheet B/510.
Options / Accessories:
Duplex Mi-cable thermocouples with duplex plug for direct connection to 2-circuit panel, and junction box connector with 1/2 inch NPT
on lead wire types with bare ends only.
Specifications:
Ordering code:
Specifications:
length of adapter)
Ordering code:
Specifications:
Probe diameter : 6 or 8 mm
steel braid
Ordering code:
Specifications:
Probe diameter : 6 or 8 mm
Ordering code:
Specifications:
Bore : 8,4 mm
Surface clearance : 40 mm
Specifications:
Bore : 9 mm
Hex size : 17 mm
Surface clearance : 10 mm
Descriptions: Issues:
x Miniature resistance thermometer with quick coupling connector C/110 Rev.00 08/03
x Miniature resistance thermometer locking connector with push release C/120 Rev.00 08/03
x Miniature resistance thermometer with SS armoured lead wire C/210 Rev.00 08/03
x Miniature resistance thermometer with PVC insulated lead wire C/220 Rev.00 08/03
x Miniature resistance thermometer with Teflon insulated lead wire C/310 Rev.00 08/03
x Mi-cable miniature resistance thermometer with SS bendable sheath C/420 Rev.00 08/03
¹) Rigid construction:
min. immersion length : 15 mm
max. immersion length : 500 mm
²) Bendable construction:
min. immersion length : 50 mm
max. immersion length 2-wire : 750 mm
3-wire : 15 m
4-wire : 30 m
Construction:
1. Rigid
2. Bendable
Wire type:
2-wire 3-wire 4-wire
End termination
5
A K V
M
B L
D
C P/
U
5
( For flexible armour only)
Options
6 7
A C E
B D
Because of the large number of possible combinations, some constructions will be subject to availability of materials and
technical feasibility. Please contact your nearest THERMO ELECTRIC office for confirmation.
Specifications:
Ordering code:
Probe diameter Wiring Single Duplex
system
‘A’ ‘A’
3,0 mm 2-wire MRT-10302-Pt100-MM
3-wire MRT-11302-Pt100-MM
4-wire MRT-13302-Pt100-MM
6,0 mm 2-wire MRT-10602-Pt100-MM MRT-12602-Pt100-MM
3-wire MRT-11602-Pt100-MM
4-wire MRT-13602-Pt100-MM
Specifications:
Ordering code:
Specifications:
Ordering code:
Probe diameter Wiring Single Duplex
system
‘A’ ‘B’ ‘A’ ‘B’
3,0 mm 2-wire MRT-30302-Pt100MM
3-wire MRT-31302-Pt100MM
4-wire
MRT-33302-Pt100MM
6,0 mm 2-wire MRT-30602-Pt100MM MRT-32602-Pt100MM
3-wire MRT-31602-Pt100MM MRT-34602-Pt100MM
4-wire MRT-33602-Pt100MM
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified) Also available in inches
Specifications:
Ordering code:
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified) Also available in inches
Specifications:
Ordering code:
Probe diameter Wiring Single Duplex
system
‘A’ ‘B’ ‘A’ ‘B’
3,0 mm 2-wire MRT-60302-Pt100MM
3-wire MRT-61302-Pt100MM
4-wire MRT-63302-Pt100MM
6,0 mm 2-wire MRT-60602-Pt100MM MRT-62602-Pt100MM
3-wire MRT-61602-Pt100MM MRT-64602-Pt100MM
4-wire MRT-63602-Pt100MM
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified) Also available in inches
Specifications:
Ordering code:
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified)
Specifications:
Ordering code:
Specifications:
Ordering code:
MRT71000 : 9167306
Specifications:
Probe type : construction with parallel sheath; not bendable over first 50 mm from tip
Temperature range : -50 to +300°C
Element type : Pt100, single
Resistance values and tolerances : IEC-751 class B
Recommended maximum current : 5 mA
Minimum insulation resistance : 10 Mohm at ambient temperature with 200 V DC
Wiring system : 3 or 4 wire from element
Lead wire : Teflon insulated flexible copper wire
Max. temperature limit lead wire : 200 °C
Max. temperature transition : 200 °C
Sheath material : SS 316
Probe length 'A' : to be specified; replace box in ordering code with your required length;
standard lengths are 150 mm, 250 mm, 350 mm, 500 mm and 750 mm
Lead wire length 'B' : to be specified; replace box in ordering code with your required length;
standard lengths are 500 mm, 1500 mm, 2500 mm and 5000 mm
Ordering code:
= probe length ‘A’ and lead wire length ‘B’ in mm (to be specified)
Descriptions: Issues:
x Mi-cable thermocouple probes with light weight connection head D/210 Rev.00 08/03
x Resistance thermocouple probes with light weight connection head D/211 Rev.00 08/03
x Temperature sensors classified ship-board and industrial heavy duty D/300 Rev.00 08/03
x Temperature sensors marine applications and heavy environments D/301+r Rev.00 08/03
x Diesel engine temperature sensors with bar stock thermowell D/310 Rev.00 08/03
x Diesel engine thermocouples with adjustable mounting bushing D/315 Rev.00 08/03
x Bearing oil temperature sensors with adjustable mounting bushing D/320 Rev.00 08/03
x Weld-in type temperature sensors with bar stock thermowell D/325 Rev.00 08/03
x Screw-in type temperature sensors with bar stock thermowell D/330 Rev.00 08/03
x Direct immersion temperature sensors with fixed bush D/335 Rev.00 08/03
x Storage room temperature sensors for direct immersion D/340 Rev.00 08/03
x Cargo temperature sensors for measuring on or in cargo D/345 Rev.00 08/03
Specifications:
Series : OTP-50.000
chromel-alumel, type K
aluminium head
Ordering code:
Specifications:
Series : OTP-60.000
chromel-alumel, type K
copper-constantan, type T
200 V DC
aluminium head
Ordering code:
Specifications:
Series : OTP-70.000
Probe type : mineral insulated single or duplex
thermocouple
Thermocouple type : iron-constantan, type J
chromel-alumel, type K
copper constantan, type T
Standard limits of error : ANSI MC 96.1/IEC-584
Insulation material : densely packed MgO, 99,6% purity
Probe diameter : 4,8 mm (3/16")
6,4 mm (1/4")
Sheath material : SS 316 for type J and T (Wstnr.1.4401)
and Inconel 600 for type K (Wstnr.2.4816)
Hot junction : insulated, common insulated for duplex
Minimum insulation resistance : 10 Mohm at ambient temperature with 200
V DC
Connection : cast aluminium DIN form B with ceramic
terminal block
Conduit entry : PG 16 cable gland
Probe length 'A' : to be specified; replace box in ordering
code with your required length; our
standard lengths are 150 mm, 250 mm,
350 mm, 500 mm and 750 mm
Adjustable mounting bushing : to be specified separately;
material stainless steel
mounting thread: 1/4” NPT
probe ordering code
4,8 mm MTS-90482
6,4 mm MTS-90642
For other types, see datasheet B/410
Ordering code:
= probe length ‘A’ in mm (to be specified)
Probe diameter Thermocouple type Single Duplex
‘A’ ‘A’
4,8mm (3/16”) Type J OTP-70481- J - mm OTP-72481- J - mm
Type K OTP-70483- K - mm OTP-72483- K- mm
Type T OTP-70481- T - mm OTP-72481- T- mm
6,4mm (1/4”) Type J OTP-70641- J - mm OTP-72641- J - mm
Type K OTP-70643- K - mm OTP-72643- K- mm
Type T OTP-70641- T - mm OTP-72641- T- mm
Specifications:
Series : OTP-80.000
Probe type : sheathed construction
Temperature range : -50 to +400°C
Element type : Pt100, single or duplex
Resistance values and tolerances : IEC-751 class B
Nominal resistance : 100 Ohm ± 0,1 at 0 °C
Nominal temperature coefficient : 0,00385
Recommended maximum current : 10 mA
Minimum insulation resistance : 10 Mohm at ambient temperature with 200
V DC
Wiring system : 2, 3 or 4 wire
Inner lead resistance : negligible
Connection : cast aluminium DIN form B with ceramic
terminal block
Conduit entry : PG 16 cable gland
Sheath material : SS 316 (Wstnr.1.4401)
Probe length 'A' : to be specified; replace box in ordering
code with your required length; our
standard lengths are 150 mm, 250 mm,
350 mm, 500 mm and 750 mm
Adjustable mounting bushing : to be specified separately;
material stainless steel
mounting ordering
probe thread code
6,0 mm M12 x 1,5 mm MTS-90603
Ordering code:
Wiring system Single Duplex
‘A’ ‘A’
2 wire OTP-80602- Pt100- mm OTP-82602- Pt100 - mm
3 wire OTP-81602- Pt100 - mm OTP-84602- Pt100 - mm
4 wire OTP-83602- Pt100 - mm
Specifications:
CONNECTION HEAD
Type : light weight head with cover
(DIN form B)
Material : cast-aluminium
Conduit entry : PG 16 cable gland
Cable diameter : 11,5 mm - 15,5 mm
INSERT
Thermocouple : series TEE-20.000 single or duplex (probe
diameter 4,8 mm)
Resistance thermometer : series RTD-20.000 single or duplex 3-wire
system (max. operating temperature 400
°C, probe dia. 6,0 mm)
Insert length 'A' : for replacement insert add 155 mm to 'U'
length
PROTECTION TUBE
Type : closed tube with welded on mounting bush
Material : SS 316 (Wst.nr. 1.4401)
Mounting bush : G 1/2” (B.S.P.P.)
Outside dia. x wall thickness : 9,5 x 0,9 mm
Extension : approx. 125 mm
Immersion length 'U' : to be specified; replace box in ordering
code with your required length; our
standard lengths are 150 mm, 250 mm,
and 500 mm
Ordering code:
SINGLE DUPLEX
Complete assembly Replacement insert Complete assembly Replacement insert
‘U’ ‘A’ ‘U’ ‘A’
OTP-75952- J - mm TEE-20482- J - mm OTP-76952- J - mm TEE-22484 J - mm
OTP-75952- K - mm TEE-20482- K - mm OTP-76952- K - mm TEE-22484- K - mm
OTP-75952- T - mm TEE-20482- T - mm OTP-76952- T - mm TEE-22484- T - mm
OTP-75952- Pt100 - mm RTD-23603- Pt100 - mm OTP-76952- Pt100 - mm RTD-24606- Pt100 - mm
Specifications:
Ordering code:
Specifications:
INTRODUCTION
Accurate temperature measurement under severe conditions has always been a demand on board of ships and power plants.
Especially for applications where automated control is involved and maintenance interval periods are longer, additional requirements
for critical parts are increasingly specified.
Major classification companies, such as Bureau Veritas (B.V.) and Lloyd's Register of Shipping (L.R.) ask for type testing and provide
the necessary approvals.
THE PRODUCTS
A complete range of THERMO ELECTRIC thermocouples and resistance thermometers fulfilling these demands is available now.
These sensors are approved for use on board ships classified with an Automation Mark by the main classification companies, and are
constructed to provide the maximum durability and service.
APPLICATIONS
Typical examples of applications are shown on the reverse side of this sheet.
Please note that the use of these sensors is not limited to their use on board of ships and power-plants only.
Type tested sensors are also often used in industrial applications.
Certificates of Approval are available on request.
Please specify classification company and sensor type.
The Thermo Electric temperature sensors are used in the following temperature measurement applications:
Diesel and steam (turbine) engines: Cargo/storage rooms and holds: Miscellaneous:
cooling system containers heaters
scavenge air refrigerating plants/containers exchangers
exhaust gases room ambient air compressors
steam pipes cooling air storage tanks
lubricating and fuel oil hydraulic systems
bearings purifiers
See our datasheet D/301 for further information and references to detailed specification sheets.
For more information please contact our nearest sales office.
Specifications:
DIESEL ENGINE
Exhaust gas or main engines. Thermocouple or resistance
For temperatures up to 600 qC. thermometer with bar stock
thermowell.
Datasheet D/310.
Exhaust gas or generator engines. Thermocouple with protection tube
For temperatures up to 600 qC. and adjustable mounting bush.
Datasheet D/310.
Cooling systems and exhaust gas of Direct immersion thermocouple
auxiliary engines. with adjustable mounting bush.
For temperatures up to 600 qC. Datasheet D/310.
Bearing oil. Thermocouple or resistance
For temperatures up to 400 qC (t/c) and thermometer with adjustable
160 qC (RTD). mounting bush.
Datasheet D/320.
STEAM BOILERS
High pressure steam pipes with low Weld-in type sensor with bar stock
vibrations. thermowell and connection head.
For temperatures up to 550 qC. Datasheet D/320.
High pressure steam pipes with high Weld-in type sensor with bar stock
vibrations. thermowell and extension leads.
For temperatures up to 550 qC. Datasheet D/320.
MISCELLANEOUS
Pressurized water, oil and air systems for Temperature sensor with bar
high temperatures stock thermowell and connection
For temperatures up to 550 qC. head.
Datasheet D/330.
Low pressurize water, oil and air systems Temperature sensor with fixed
for low temperatures mounting bush and extension
For temperatures up to 250 qC. leads.
Datasheet D/330.
Specifications:
STORAGE
Coolers, containers. Resistance thermometer for direct
Temperature Range -30 °C to +70 °C. immersion.
Datasheet D/340.
Cargo and inside storage rooms. Resistance thermometer for
Temperature Range -30 °C to +60 °C. mounting on storage.
Datasheet D/340.
Cargo temperature. Resistance thermometer for
Temperature Range -30 °C to +60 °C. penetration in cargo.
Datasheet D/340.
AIR
Specifications:
springloaded insert
and 5000 mm
Ordering code:
MOUNTING THREAD
Sensor type 1/2” B.S.P.P. M 18 x 1,5 M 33 x 2
‘A’ ‘B’ ‘A’ ‘B’ ‘A’ ‘B’
J OTP-10051- J --mm OTP-10061- J --mm OTP-10071- J --mm
K OTP-10051- K --mm OTP-10061- K --mm OTP-10071- K --mm
Pt100 OTP-10055- Pt100 --mm OTP-10065- Pt100 --mm OTP-10075- Pt100 --mm
Specifications:
Specifications:
Type : single replaceable mi-cable t/c
Thermocouple type : iron-constantan, type J
chromel-alumel, type K
Standard limits of error : ANSI MC 96.1 / IEC-584
Hot junction : insulated
Ceramo o.d. : 8 mm
Sheath material : SS 304, type J
Carbon steel mounting bush : to be ordered separately, see below
Probe length 'A' : to be specified; replace box in ordering
code with your required length; our
standard length is 225;
Max. immersion length : probe length minus 100 mm (max. 125 mm)
Lead wire length 'B' : to be specified; replace box in ordering
code with your required length; our
standard lengths are 1000 mm, 3000 mm
and 5000 mm
Approval : Lloyd's Register and Bureau Veritas
Ordering code Thermocouple type
‘A’ ‘B’
OTP-10031-J- - mm : iron-constantan, type J
OTP-10031-K- - mm : chromel-alumel, type K
OTP-90801 : mounting bush 1/4” BSP.P
OTP-90802 : mounting bush 3/8” BSP.P
OTP-90803 : mounting bush 1/2” BSP.P
Specifications:
Ordering code:
Sensor type Mounting bush thread
‘A’
J OTP-15081- J -mm M18 x 1,5 OTP-91481
K OTP-15081- K -mm M24 x 1,5 OTP-91482
Pt100 OTP-15085- Pt100 -mm 1/2” BSP.P OTP-91483
= probe length ‘A’ in mm (to be specified)
Specifications:
Specifications:
Type : single thermocouple or resistance
thermometer with replaceable insert
Thermocouple type : iron-constantan, type J insulated junction
chromel-alumel, type K insulated junction
Standard limits of error : ANSI MC 96.1 / IEC-584
Resistance type and tolerances : Pt100, IEC-751 class B, 3-wire system
Thermowell : drilled bar stock
Thermowell material : 13 CrMo 4 4 (Wstnr.1.7335)
Max. welding length : 175 mm is maximum length from tip of the
thermowell to the welded joint; the welding
length has to be selected, such that only the
conical tip will be immersed
Lead wire : teflon/kapton insulated flexible wire with
stainless steel braiding (type TFHF/TWS)
Lead wire length 'B' : to be specified; replace box in ordering code
with required length; our standard lengths are
3000 mm, 5000 mm and 7000 mm
Approval : Lloyd's Register and Bureau Veritas
Ordering code Sensor type
‘B’
OTP-15011-J- mm : iron-constantan, type J
OTP-15011-K- mm : chromel-alumel, type K
OTP-15015-Pt100- mm Pt100
Specifications:
Ordering code:
MOUNTING THREAD
Well material Sensor type 1/2” B.S.P.P. M 18 x 1,5 M 33 x 2
‘A’ ‘A’ ‘A’
SS 316 J OTP-15333- J -mm OTP-15343- J -mm OTP-15353- J -mm
K OTP-15333- K -mm OTP-15343- K -mm OTP-15353- K -mm
Pt100 OTP-15337- Pt100 -mm OTP-15347- Pt100 -mm OTP-15357- Pt100 -mm
CiNi 10 Fe J OTP-15333- J -mm OTP-15343- J -mm OTP-15353- J -mm
K OTP-15333- K -mm OTP-15343- K -mm OTP-15353- K -mm
Pt100 OTP-15337- Pt100 -mm OTP-15347- Pt100 -mm OTP-15357- Pt100 -mm
= immersion length ‘A’ in mm (to be specified)
Specifications:
Ordering code:
MATERIAL
Sensor type SS 316 Brass
‘A’ ‘B’ ‘A’ ‘B’
J OTP-15061- J --mm OTP-15051- J --mm
K OTP-15061- K --mm OTP-15051- K --mm
Pt100 OTP-15065- Pt100 --mm OTP-15055- Pt100 --mm
Specifications:
Ordering code:
Probe
‘B’
8 mm OTP-17015- Pt100 -mm
12 mm OTP-17025- Pt100 -mm
Specifications:
Type : PVC covered resistance thermometer with
eyelet for hanging purposes
Sensor diameter : 15 mm
Temperature range : -30 to +60 °C
Element type : Pt100, single
Resistance values and tolerances : IEC-751 class B (1/6 DIN at 0 °C)
Wiring system : 4-wire
Lead wire : PVC insulated flexible wire
Lead wire length 'B' : to be specified; replace box in ordering
code with required length; our standard
length is 12000 mm
Approval : Lloyd's Register and Bureau Veritas
Ordering code
‘B’
OTP-17035-Pt100- mm
Specifications:
Type : PVC covered resistance thermometer with
SS needle tip
Temperature range : -30 to +60 °C
Element type : Pt100, single
Resistance values and tolerances : IEC-751 class B (1/6 DIN at 0 °C)
Wiring system : 4-wire
Lead wire : PVC insulated flexible wire
Lead wire length 'B' : to be specified; replace box in ordering
code with required length; our standard
length is 12000 mm
Approval : Germanischer Lloyd, Lloyd's Register and
Bureau Veritas
Ordering code
‘B’
OTP-17045-Pt100- mm
Specifications:
o.d.
Ordering code:
Specifications:
Type : resistance thermometer with fixed
mounting
Ordering code
OTP-18037- Pt100
Specifications:
Type : resistance thermometer with adjustable
mounting bush
length is 3000 mm
Ordering code
OTP-18015-Pt100- mm
Descriptions: Issues:
x Thermocouple wire, PVC insulated (rip cord); 150°C E/1.100 Rev.00 08/03
x Thermocouple wire, PVC insulated, twisted, copper braided; 90°C E/1.150 Rev.00 08/03
Specifications:
ANSI MC96.1 1982; cryogenic grade IEC 584-2 1989; class 3 (cryogenic)
Range Tolerance* Range Tolerance*
Type qC qC % Type qC qC %
K -200 - 0 2,2 2 K -200 - 40 2,5 1,5
T -200 - 0 1 1,5 T -200 - 40 1 1,5
E -200 - 0 1,7 1 E -200 - 40 2,5 1,5
* Whichever is greater.
** Not yet officially listed in standard, values given are expected values to be adopted in next issue.
When your application requires other tolerances or a combination of the above listed ranges, THERMO ELECTRIC can select
and calibrate thermocouple materials to meet your requirements.
Specifications:
The above listed dimensions are nominal values for comparison purposes only.
Features: Applications:
Specifications:
Conductor size
AWG mm outer mm weight/km
24 0,51 1,0 x 2,0 6,1 kg
26 0,40 0,9 x 1,8 2,8 kg
Ordering code:
Features: Applications:
Specifications:
Conductor size
2
AWG mm mm outer mm weight/km
24F 7 x 0,2 0,23 4,8 35 kg
Ordering code:
Features: Applications:
Specifications:
Conductor size
AWG mm outer mm weight/km
20 0,8 1,5 x 2,5 10,3 kg
24 0,5 1,1 x 1,8 4,2 kg
Ordering code:
TE/D AUTOCLAVE
TYPICAL DUPLEX WIRE OTHER SINGLE EXTRUSION WIRE THERMOCOUPLE WIRE
Features: Applications:
Specifications:
Conductor size
2
AWG mm mm outer mm weight/km
24 0,51 0,205 1,0 x 2,0 6,1 kg
28 0,32 0,08 0,8 x 1,8 3,4 kg
Ordering code:
®
Trademark Dupont
Features: Applications:
Specifications:
Conductor size
AWG mm outer mm weight/km
20 0,8 1,8 x 3,0 14,7 kg
24 0,5 1,6 x 2,5 8,4 kg
30 0,25 1,2 x 1,8 5,6 kg
Ordering code:
Chromel-alumel Tex/Tex-20-KK ANSI 9151415 Tex/Tex-24-KK ANSI 9151416 Tex/Tex-30-KK ANSI 9151417
Tex/Tex-20-KK IEC Tex/Tex-24-KK IEC 9151425 Tex/Tex-30-KK IEC 9151427
Copper-constantan Tex/Tex-20-TT ANSI 9151419 Tex/Tex-24-TT ANSI 9151420 Tex/Tex-30-TT ANSI 9151421
Tex/Tex-20-TT IEC Tex/Tex-24-TT IEC 9151428 Tex/Tex-30-TT IEC 9151420
®
Trademark Dupont
Features: Applications:
Specifications:
(nominal values)
Conductor size
2
AWG mm mm outer mm weight/km
24F 7 x 0,2 0,23 1,1 x 2,2 8,6 kg
Ordering code:
Calibration 24F AWG Stock number
Iron-constantan Tex/Tw-24F-JJ ANSI 9151400
Tex/Tw-24F-JJ IEC 9151406
Chromel-alumel Tex/Tw-24F-KK ANSI 9151402
Tex/Tw-24F-KK IEC 9152307
Copper-constantan Tex/Tw-24F-TT ANSI 9151404
Tex/Tw-24F-TT IEC 9151408
Copper-copper alloy Tex/Tw-24F-SX
®
Trademark Dupont
Features: Applications:
Specifications:
others optional
Conductor size
2
AWG mm mm outer mm weight/km
24F 7 x 0,2 0,23 3,0 x 3,5 25 kg
Ordering code:
Features: Applications:
Specifications:
Conductor size
AWG mm outer mm weight/km
20 0,8 1,8 x 3,4 11,9 kg
24 0,5 1,6 x 2,5 5,8 kg
Ordering code:
Features: Applications:
Specifications:
Conductor size
2
AWG mm mm outer mm weight/km
18F 7 x 0,4 0,91 3,8 25 kg
Ordering code:
Calibration 18F AWG Stock #
Iron-constantan TfHf/Tw-18F-JX ANSI 9152472
TfHf/Tw-18F-JX IEC
Chromel-alumel TfHf/Tw-18F-KX ANSI 9152473
TfHf/Tw-18F-KX IEC
®
Trademark Dupont
Features: Applications:
Specifications:
Electrical/Physical
Insulation passes 6000 V AC spark test.
Completed construction passes a dielectric test of 5000 V DC for 1 minute (conductor-
to-conductor); 0,15 mm wall breakdown strength in excess of 10 KV
Operating temperature (max.) : 285 °C (400 °C for limited duration)
Operating temperature (min.) : -265 °C
Flammability : self-extinguishing
Chemical resistance : excellent
9
Radiation resistance : 10 rad.
Bend radius test (min.) : 4 x o.d.
Conductor size
AWG mm outer mm weight/km
20 0,8 1,5 x 2,6 11,5 kg
28 0,32 1,0 x 1,6 4,1 kg
Ordering code:
Features: Applications:
Specifications:
Electrical/Physical
Operating temperature (max.) : 285 °C (400 °C for limited duration)
Operating temperature (min.) : -265 °C
Flammability : self-extinguishing
Chemical resistance : excellent
9
Radiation resistance : 10 rad.
Bend radius test (min.) : 4 x o.d.
Conductor size
AWG mm outer mm weight/km
30 0,25 0,6 x 0,9 2,1 kg
Ordering code:
Features: Applications:
Specifications:
Conductor size
AWG mm outer mm weight/km
16 1,3 2,1 x 3,8 30,0 kg
20 0,8 1,4 x 2,5 13,4 kg
24 0,5 1,0 x 1,7 6,2 kg
30 0,25 0,8 x 1,2 3,3 kg
32 0.2 0,8 x 1,1 3,2 kg
36 0,13 0,7 x 1,1 3,0 kg
Ordering code:
Calibration
20 AWG Stock # 24 AWG Stock # 30 AWG Stock #
Iron-constantan G/G-20-JJ ANSI G/G-24-JJ ANSI G/G-30-JJ ANSI
G/G-20-JJ IEC 9151635 G/G-24-JJ IEC 9151636 G/G-30-JJ IEC 9151637
Chromel-alumel G/G-20-KK ANSI G/G-24-KK ANSI 9151627 G/G-30-KK ANSI 9151628
G/G-20-KK IEC 9151638 G/G-24-KK IEC 9151639 G/G-30-KK IEC 9151641
Copper-constantan G/G-20-T ANSI 9151629 G/G-24-TT ANSI G/G-30-TT ANSI
G/G-20-T IEC G/G-24-TT IEC G/G-30-TT IEC
Also available in thermocouple extension grade and/or different wire sizes
Features: Applications:
Specifications:
others optional
Conductor size
AWG mm outer mm weight/km
20 0,8 1,8 x 3,8 16,4 kg
22 0,65 1,4 x 2,9 11,5 kg
Ordering code:
Features: Applications:
Specifications:
Conductor size
AWG mm outer mm weight/km
20 0,8 2,1 x 3,6 18,5 kg
Ordering code:
Features: Applications:
Specifications:
Conductor size
AWG mm outer mm weight/km
20 0,8 2,5 x 4,2 17,8 kg
24 0,5 2,2 x 3,6 11,9 kg
Ordering code:
Features: Applications:
x Best abrasion resistance at high temp. x Glass, ceramic, brick and metal
temperature industry
x Max. temperature up to 1400 °C x Oven surveys
Specifications:
Conductor size
AWG mm outer mm weight/km
14 1,6 3,2 x 5,8 51,6 kg
16 1,3 3,2 x 5,4 37,1 kg
20 0,8 2,7 x 4,5 21,4 kg
Ordering code:
Descriptions: Issues:
x Thermocouple extension wire PVC insulated, twisted and shielded; 105 °C F/2.210 Rev.00 08/03
x Thermocouple extension wire PVC insulated, twisted, shielded and armoured; F/2.211 Rev.00 08/03
105 °C
®
x Thermocouple extension wire Teflon insulated, twisted and silicon jacket; F/2.400 Rev.00 08/03
205 °C
x Thermocouple extension wire silicon insulated and twisted; 180 °C F/2.500 Rev.00 08/03
x Thermocouple extension cable PVC insulated, twisted and overall shielded; F/3.150 Rev.00 08/03
105 °C
x Thermocouple extension cable PVC insulated, individual and overall shielded; F/3.151 Rev.00 08/03
105 °C
x Thermocouple extension cable PVC insulated, twisted and overall shielded, F/3.250 Rev.00 08/03
armoured; 105 °C
x Thermocouple extension cable PVC insulated, individual and overall shielded, F/3.251 Rev.00 08/03
armoured; 105 °C
Example:
P / AL P W P TW - 16 - KX
~ ~ ~ ~ ~ ~ ~ ~
1 2 3 4 5 6 7 8
6 Twisted conductors
8 Chromel-alumel conductors
Example:
P / ALM / AL P W P TW K - 12 - 20 - KX
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
1 2 3 4 5 6 7 8 9 10 11
7 Twisted conductors
11 Chromel-alumel conductors
Specifications:
Specifications:
Specifications:
no. of inner jacket outer jacket outer min. bend tension nett weight
pairs thickness thickness diameter radius loading (kg) kg/km
1 0.9 1.1 8.8 108 40 132
2 1.1 1.3 12.4 152 63 244
4 1.1 1.3 13.5 165 96 300
6 1.3 1.6 16.3 197 151 437
8 1.3 1.6 17.2 210 203 488
10 1.3 1.6 19.4 235 232 645
12 1.3 1.6 19.8 241 260 688
16 1.6 1.9 22.0 267 305 826
20 1.6 1.9 24.7 299 396 1060
24 1.6 1.9 26.0 318 458 1211
36 1.9 1.9 29.0 349 743 1467
50 1.9 2.2 33.5 406 1137 2082
Specifications:
no. of inner jacket outer jacket outer min. bend tension nett weight
pairs thickness thickness diameter radius loading (kg) kg/km
2 1.1 1.3 13.6 165 68 282
4 1.3 1.6 16.5 197 105 430
6 1.3 1.6 19.2 229 164 606
8 1.3 1.6 20.2 241 221 685
10 1.6 1.9 24.5 292 278 991
12 1.6 1.9 24.5 292 287 1031
16 1.6 1.9 26.3 318 342 1182
20 1.6 1.9 28.3 343 442 1340
24 1.9 1.9 31.4 381 512 1721
36 1.9 2.2 34.8 419 825 2143
50 1.9 2.2 39.1 470 1250 2619
Features: Applications:
Specifications:
Calibration
Iron-constantan JX
Chromel-alumel KX
Copper-constantan TX
Type S compensating SX
Conductor size
2
AWG mm mm outer mm weight/km
20F 16 x 0,2 0,5 5,1 30,0 kg
24F 7 x 0,2 0,23 3,8 19,0 kg
Ordering code:
Features: Applications:
Specifications:
Calibration
Iron-constantan JX
Chromel-alumel KX
Copper-constantan TX
Nicrosil-nisil NX
Type S compensating SX
Conductor size
AWG mm outer mm weight/km
14 1,6 3,7 x 6,3 47,6 kg
16 1,3 2,8 x 4,8 34,2 kg
18 1,0 2,5 x 4,3 23,8 kg
20 0,8 2,3 x 3,9 17,8 kg
20F 7 x 0,3 2,5 x 4,2 18,1 kg
Ordering code:
Calibration 16 AWG ANSI 20 AWG ANSI/IEC
Iron-constantan P/P-16-JX 9152171 P/P-20-JX 9152172/9152183
Chromel-alumel P/P-16-KX 9152173 P/P-20-KX 9152174/9152185
Copper-constantan P/P-16-TX 9152176 P/P-20-TX 9152177
Features: Applications:
Specifications:
Construction
Conductors : 1,3 mm² (16 AWG) or 0,5 mm² (20
AWG) solid extension grade according
to ITS 1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted conductors
Lay of twist : 55 mm nominal
Shield : 0,05 mm polyester-backed aluminium
tape, 100% coverage and 35% overlap
Drain wire : 0,9 mm² (18 AWG), 7 strands, tinned
copper
Jacket : 90°C PVC, 0,5 mm nominal (0,9 for UL)
Limits of error : according to ANSI MC 96.1/IEC-584
Colour code : according to IEC-584
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor
to conductor and conductor to shield).
Conductor resistance : see sheet table
Capacitance (conductor to conductor) : 187 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Flame test : flame retardant as per IPCEA S-61-402
Ordering code:
Features: Applications:
Specifications:
Construction
Conductors : 1,3 mm² (16 AWG) solid extension
grade according to ITS 1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted conductors
Lay of twist : 55 mm nominal
Shield : 0,05 mm polyester-backed aluminium
tape, 100% coverage and 35% overlap
Drain wire : 0,9 mm² (18 AWG), 7 strands, tinned
copper
Inner jacket : 90°C PVC, 0,5 mm nominal
Armour : galvanized steel wire, 0,64 mm o.d.
nominal, 80% coverage
Outer jacket : 90°C PVC, o,8 mm nominal
Limits of error : according to ANSI 96.1/IEC-584
Colour code : according to ANSI 96.1/IEC-584
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor
to conductor and conductor to shield).
Conductor resistance : see sheet table
Capacitance (conductor to conductor) : 187 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
(nominal values)
Ordering code:
Calibration 16 AWG
Iron-constantan P/ALPWpTw-16-JX
Chromel-alumel P/ALPWpTw-16-KX
Copper-constantan P/ALPWpTw-16-TX
Features: Applications:
Specifications:
Calibration
Iron-constantan JX
Chromel-alumel KX
(nominal values)
Conductor size
2
AWG mm mm outer mm weight/km
20F 16 x 0,2 0,25 4,2 30 kg
Ordering code:
®
Trademark Dupont
Specifications:
Construction
Conductors : 0,8 mm² (20 AWG) solid, thermocouple
extension grade according to ITS 1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted pairs
Lay of twist : 35 to 60 mm staggered
Communication wire : 0,35 mm² (22 AWG), 7 strands copper,
PVC insulated
Cable shield : 0,05 mm polyester-backed aluminium
tape and 0,05 mm polyester separation
tape, 100% coverage and 35% overlap
Cable drain wire : 0,56 mm² (20 AWG), 7 strands, tinned copper
Jacket : 90°C PVC
Group identification : each pair numbered
Limits of error : according to ANSI MC 96.1/IEC-584
Colour code : according to IEC 584
Calibration
Iron-constantan JX
Chromel-alumel KX
Copper-constantan TX
Nisil-nicrosil NX
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor
to conductor and conductor to shield).
Nom. loop resistance (JX, KX and TX) : resp. 117, 193 and 97,8 Ohm/100 m
Capacitance (conductor to conductor) : 102 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Flame test : flame retardant as per IPCEA S-61-402
Number of pairs :2,4,8,12,and 24, other pairs on request.
Other colour code on request (ANSI MC-96.1)
Ordering code:
Specifications:
Construction
Conductors : 0,8 mm² (20 AWG) solid, thermocouple
extension grade according to ITS 1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted pairs
Lay of twist : 50 mm nominal
Individual shield : 0,035 mm polyester-backed aluminium
tape and 0,025 m polyester separation
tape providing 100% coverage
Drain wire : 0,35 mm² (22 AWG), 7 strands tinned
copper
Communication wire : 0,35 mm² (22 AWG), 7 strands copper,
PVC insulated
Cable shield : 0,05 mm polyester-backed aluminium
tape and 0,05 mm polyester separation
tape, 100% coverage and 35% overlap
Cable drain wire : 0,56 mm² (20 AWG), 7 strands, tinned
copper
Jacket : 90°C PVC
Group identification : each pair numbered
Limits of error : according to ANSI MC 96.1/IEC-584
Colour code : according to ANSI MC 96.1/IEC-584
Calibration
Iron-constantan JX
Chromel-alumel KX
Copper-constantan TX
Nisi-nicrosil NX
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor to
conductor and conductor to shield).
Nom. loop resistance (JX, KX and TX) : resp. 117, 193 and 97,8 Ohm/100 m
Capacitance (conductor to conductor) : 147 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Flame test : flame retardant as per IPCEA S-61-402
Ordering code:
Iron-constantan : UP/ALM/ALPTWK - - 20 - JX
Chromel-alumel : UP/ALM/ALPTWK - - 20 - KX
Copper-constantan : UP/ALM/ALPTWK - - 20 - TX
Nisil-nicrosil : UP/ALM/ALPTWK - - 20 - NX
Select number of pairs.
Other colour codes are available on request (ANSI MC 96.1)
Specifications:
Construction
Conductors : 0,8 mm² (20 AWG) solid, thermocouple
extension grade according to ITS 1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted pairs
Lay of twist : 35 to 60 mm staggered
Communication wire : 0,35 mm² (22 AWG), 7 strands copper,
PVC insulated
Cable shield : 0,05 mm polyester-backed aluminium
tape and 0,05 mm polyester separation
tape, 100% coverage and 35% overlap
Cable drain wire : 0,56 mm² (20 AWG), 7 strands, tinned
copper
Inner jacket : 90°C PVC
Armour : galvanized steel wire, 80% coverage
Outer jacket : 90°C PVC
Group identification : each pair numbered
Limits of error : according to ANSI MC 96.1/IEC-584
Colour code : according to ANSI MC 96.1/IEC-584
Calibration
Iron-constantan JX
Chromel-alumel KX
Copper-constantan TX
Nisil-nicrosil NX
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor
to conductor and conductor to shield).
Nom. loop resistance (JX, KX and TX) : resp. 117, 193 and 97,8 Ohm/100 m
Capacitance (conductor to conductor) : 102 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Flame test : flame retardant as per IPCEA S-61-402
Ordering code:
Iron-constantan : UP/ALPWPTWK - - 20 - JX
Chromel-alumel : UP/ALPWPTWK - - 20 - KX
Copper-constantan : UP/ALPWPTWK - - 20 - TX
Nisil-Nicrosil : UP/ALPWPTWK - - 20 - NX
Select number of pairs.
Other colour codes are available on request (ANSI MC 96.1)
Specifications:
Construction
Conductors : 0,8 mm² (20 AWG) solid, thermocouple
extension grade according to ITS 1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted pairs
Lay of twist : 50 mm nominal
Individual shield : 0,035 mm polyester-backed aluminium
tape and 0,025 m polyester separation
tape providing 100% coverage
Drain wire : 0,35 mm² (22 AWG), 7 strands tinned
copper
Communication wire : 0,35 mm² (22 AWG), 7 strands copper,
PVC insulated
Cable shield : 0,05 mm polyester-backed aluminium
tape and 0,05 mm polyester separation
tape, 100% coverage and 35% overlap
Cable drain wire : 0,56 mm² (20 AWG), 7 strands, tinned
copper
Inner jacket : 90°C PVC
Armour : galvanized steel wire, 80% coverage
Outer jacket : 90°C PVC
Group identification : each pair numbered
Limits of error : according to ANSI MC 96.1/IEC-584
Colour code : according to ANSI MC 96.1/IEC-584
Calibration
Iron-constantan JX
Chromel-alumel KX
Copper-constantan TX
Nisil-nicrosil NX
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor to
conductor and conductor to shield).
Nom. loop resistance (JX, KX and TX) : resp. 117, 193 and 97,8 Ohm/100 m
Capacitance (conductor to conductor) : 147 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15ºC
Flame test : Flame retardant as per IPCEA S61-402
Ordering code:
Iron-constantan : UP/ALM/ALPWPTWK - - 20 - JX
Chromel-alumel : UP/ALM/ALPWPTWK - - 20 - KX
Copper-constantan : UP/ALM/ALPWPTWK - - 20 – TX
Nisil-nicrosil : UP/ALM/ALPWPTWK - - 20 - NX
Select number of pairs.
Other colour codes are available on request (ANSI MC 96.1)
Descriptions: Issues:
• CODE KEY instrument wire G/001 Rev.00 08/03
CODE KEY instrument cable G/002 Rev.00 08/03
• Instrument cables, dimensions and weights G/003 Rev.00 08/03
Instrument cables, dimensions and weights (armoured) G/004 Rev.00 08/03
• Instrument wire PVC insulated, shielded; 105 qC G/4.150 Rev.00 08/03
• Instrument wire PVC insulated, shielded, armoured; 105 °C G/4.151 Rev.00 08/03
• Instrument cable PVC insulated, verall shielded; 105 qC G/5.150 Rev.00 08/03
• Instrument cable PVC insulated, individual and overall shielded; 105 qC G/5.151 Rev.00 08/03
• Instrument cable PVC insulated, overall shielded, armoured; 105 qC G/5.250 Rev.00 08/03
• Instrument cable PVC insulated, individual and overall shielded, armoured; G/5.251 Rev.00 08/03
105 qC
Example:
6 Twisted conductors
Example:
7 Twisted conductors
Specifications:
Specifications:
Specifications:
no. of inner jacket outer jacket outer min. bend tension nett weight
pairs/triads thickness thickness diameter radius loading (kg) kg/km
pairs 1 0.9 1.1 9.0 110 40 140
2 1.1 1.3 12.7 150 65 250
4 1.3 1.3 14.9 180 95 360
6 1.3 1.6 16.8 200 155 450
8 1.3 1.6 18.5 220 210 590
10 1.3 1.6 20.0 240 240 670
12 1.3 1.6 20.5 250 270 720
16 1.6 1.9 24.1 290 315 1010
20 1.6 1.9 24.8 300 410 1110
24 1.6 1.9 27.0 320 475 1250
36 1.9 1.9 31.0 370 770 1780
50 1.9 2.2 34.8 420 1180 2180
Specifications:
no. of inner jacket outer jacket outer min. bend tension nett weight
pairs/triads thickness thickness diameter radius loading (kg) kg/km
pairs 2 1.1 1.3 15.0 180 70 280
4 1.3 1.6 16.6 200 110 430
6 1.3 1.6 19.3 230 165 610
8 1.3 1.6 20.4 250 235 680
10 1.6 1.9 24.6 290 270 990
12 1.6 1.9 24.7 300 305 1030
16 1.6 1.9 26.5 320 360 1180
20 1.6 1.9 28.2 340 470 1350
24 1.9 1.9 31.9 380 545 1780
36 1.9 2.2 35.1 420 870 2140
50 1.9 2.2 39.5 470 1315 2640
Features: Applications:
Specifications:
Construction
Conductors : 1,4 mm² (16 AWG) 7 strands, high
conductivity bare copper wire, class B ITS
1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted conductors
Lay of twist : pairs 55 mm, triad 65 mm nominal
Shield : 0,05 mm polyester-backed aluminium
tape, 100% coverage and 35% overlap
Drain wire : 0,9 mm² (18 AWG), 7 strands, tinned
copper
Jacket : 90°C PVC, 0,9 mm nominal
Standard colour code : pairs : black, white
triads: black, white, red
jacket : black
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor to
conductor and conductor to shield).
Conductor resistance : 13,4 Ohm/km nominal at 20°C
Capacitance (conductor to conductor) : 160 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Flame test : flame retardant as per IPCEA S-61-402
and IEEE-383
Option
600V rating (UPN/ALPTw-16F-BX)
Ordering code:
UP/ALPTW-16F-BX 9152731
UP/ALPTW-16F-BX triad 9152749
Features: Applications:
Specifications:
Construction
Conductors : 1,4 mm² (16 AWG) 7 strands, high
conductivity bare copper wire, class B
ITS 1990
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted, pair or triad
Lay of twist : pairs 55 mm, triad 65 mm nominal
Shield : 0,05 mm polyester-backed aluminium
tape, 100% coverage and 35% overlap
Drain wire : 0,9 mm² (18 AWG), 7 strands, tinned
copper
Inner jacket : 90°C PVC, 0,9 mm nominal
Armour : galvanized steel wire, 0,5 mm o.d.
nominal, 80% coverage
Outer jacket : 90°C PVC, 1,2 mm nominal
Standard colour code : pairs : black, white
triads: black, white, red
jacket : black
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor to
conductor and conductor to shield).
Conductor resistance : 13,4 Ohm/km nominal at 20°C
Capacitance (conductor to conductor) : 160 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Flame test : flame retardant as per IPCEA S-61-402 and
IEEE-383
Option
600V rating (not UL listed
Ordering code:
UP/ALPWPTW-16F-BX
UP/ALPWPTW-16F-BX triad
Other colour on request.
Features: Applications:
Specifications:
Construction
Conductors : 0,56 mm² (20 AWG) 7 strands, high
conductivity bare copper wire, class
B
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted, pairs or triads
Lay of twist : pairs 35 to 60 mm staggered
triads 50 to 75 mm staggered
Communication wire : 0,35 mm² (22 AWG), 7 strands
copper, PVC insulated
Cable shield : 0,05 mm polyester-backed
aluminium tape and 0,05 mm
polyester separation tape, 100%
coverage and 35% overlap
Cable drain wire : 0,56 mm² (20 AWG), 7 strands,
tinned copper
Inner jacket : 90°C PVC
Armour : galvanized steel wire, 80% coverage
Outer jacket : 90°C PVC
Group identification : each pair or triad numbered
Standard colour code : pairs : black, white
triads: black, white, red
jacket : black
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec
(conductor to conductor and conductor to shield).
Conductor resistance : 30,6 Ohm/km nominal at 20°C
Capacitance (conductor to conductor) : 90 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Ordering code:
Flame test : flame retardant as per IPCEA S-61-402 and IEEE-383
Option
600 V rating (not UL listed)
Features: Applications:
Specifications:
Construction
Conductors : 0,56 mm² (20 AWG) 7 strands, high
conductivity bare copper wire, class B
Insulation : 105° PVC, 0,4 mm nominal
Construction : twisted, pairs or triads
Lay of twist : 50 mm nominal
Communication wire : 0,035 mm polyester-backed aluminium
tape and 0,025 mm polyester
separation tape providing 100%
coverage
Drain wire : 0,35 mm² (22 AWG), 7 strands tinned
copper
Communication wire : 0,35 mm² (22 AWG), 7 strands copper,
PVC insulated
Cable shield : 0,05 mm polyester-backed aluminium
tape and 0,05 mm polyester separation
tape, 100% coverage and 35% overlap
Cable drain wire : 0,56 mm² (20 AWG), 7 strands, tinned
copper
Inner jacket : 90°C PVC
Armour : galvanized steel wire, 80% coverage
Outer jacket : 90°C PVC
Group identification : each pair or triad numbered
Standard colour code : pairs : black, white
triads: black, white, red
jacket : black
Electrical/Physical
Insulation passes 3000 V AC spark test.
Completed construction passes a dielectric test of 2500 V AC for 10 sec (conductor
to conductor and conductor to shield).
Conductor resistance : 30,6 Ohm/km nominal at 20°C
Capacitance (conductor to conductor) : 123 nF/km nominal
Inductance : less than 1 mH/km
Circuit voltage rating : 300 V max.
Operation temperature (max.) : insulation 105°C, jacket 90°C
Lower flexibility limit : -15°C
Flame test : flame retardant as per IPCEA S-61-402
and IEEE-383
Option
600 V rating (not UL listed)
Ordering code:
Descriptions: Issues:
Specifications:
The printing of the figures and divisions, conform to DIN standards. The antiparallax is made of printed or anodized aluminium.
On request DIN and CL. 1 or CL. 2 indicators can be printed on the dial.
Temperature range: ºC
-70 to + 50 0 to 60 0 to 200 0 to 400
-30 to + 70 0 to 100 0 to 250 0 to 500
-30 to + 170 0 to 120 0 to 300 0 to 500
-30 to + 270 0 to 160 0 to 320 0 to 600
Ordering code:
Specifications:
The printing of the figures and divisions, conform to DIN standards. The antiparallax is made of printed or anodized aluminium.
On request DIN and CL. 1 or CL. 2 indicators can be printed on the dial.
Temperature range: ºC
-70 to + 50 0 to 60 0 to 200 0 to 400
-30 to + 70 0 to 100 0 to 250 0 to 500
-30 to + 170 0 to 120 0 to 300 0 to 500
-30 to + 270 0 to 160 0 to 320 0 to 600
Ordering code:
Specifications:
The printing of the figures and divisions, conform to DIN standards. The antiparallax is made of printed or anodized aluminium.
On request DIN and CL. 1 or CL. 2 indicators can be printed on the dial.
Temperature range: ºC
-70 to + 50 0 to 60 0 to 200 0 to 400
-30 to + 70 0 to 100 0 to 250 0 to 500
-30 to + 170 0 to 120 0 to 300 0 to 500
-30 to + 270 0 to 160 0 to 320 0 to 600
Ordering code:
Descriptions: Issues:
Features:
Specifications:
Body material : tough, self extinguishing cadmium free thermoplastic compound with low moisture
absorption rate and good dielectric strength
Contacts : made of thermocouple material, plug with standard size solid pins, jacks spring
loaded, contacts polarized
Max. temperature rating : 200°C
Max. conductor diameter : 2,0 mm
Max, cable diameter : 8,0 mm
Identification : plus and minus sign moulded in body; connectors are colour coded to IEC or ANSI
extension wire code
Accessories : Bush wire grip, Crimp Inserts, Wire Clamp Brackets, Mounting Brackets and Security
Clip available. For our standard accessories see reverse side
Options private label version for OEM accounts
hollow pins lower cost
also available in duplex version (white with coloured dot)
Ordering code:
Bushing insert
Material : brass
Thermocouple : 1,0 thru 6,4 mm
Ordering code 1,0 mm : CNN19510
1,6 mm: CNN19516
3,2 mm: CNN19532
4,8 mm: CNN19548
6,6 mm: CNN19564
blind: CNN19500
Security clip
Material : stainless steel
Ordering code : CNN19000
Features:
Specifications:
Body material : fibre glass reinforced thermosetting plastic with a good dielectric strength
Contacts : made of thermocouple material, plug with standard size solid pins, jacks spring
loaded, contacts polarized
Bushing insert
Material : brass
Thermocouple : 1,0 thru 6,4 mm
Ordering code 1,0 mm : CNN19510
1,6 mm: CNN19516
3,2 mm: CNN19532
4,8 mm: CNN19548
6,6 mm: CNN19564
blind: CNN19500
Security clip
Material : stainless steel
Ordering code : CNN19000
Features:
Specifications:
Body material : tough, shatter proof thermosetting plastic with low moisture absorption rate and good
dielectric strength
Contacts : made of thermocouple material, third contact high purity copper; plug with solid pins,
jacks spring loaded, contacts polarized
Max. temperature rating : 200 °C
Max. conductor diameter : 1,6 mm
Max. cable diameter : 6,4 mm
Identification : black bodies, with calibration, polarity and ground sign stamped in body
Accessories : each plug/jack will be supplied with a neoprene bush wire grip, code number
CNN-19599; metal bushing insert for mounting connector directly on thermocouple to
be ordered separately, please specify code number for thermocouple I
1,0 mm (1/25") : CNN-19510
1,6 mm (1/16") : CNN-19516
3,2 mm (1/8") : CNN-19532
4,8 mm (3/16") : CNN-19548
6,4 mm (1/4") : CNN-19564
for other accessories see reverse side
Ordering code:
Thermocouple type Plug Jack
Iron-constantan CNN81100JBK CNN82100JBK
Chromel-alumel CNN81200KYL CNN82200KYL
Copper-constantan CNN81300TBL CNN82300TBL
PtRh-Pt CNN81400SGR CNN82400SGR
Chromel-constantan CNN81500EPL CNN82500EPL
Copper-copper* CNN81600BWH CNN82600BWH
Nicrosil-nisil CNN81700NOR CNN82700NOR
* also available with hard-nickel coated contacts, use ordering code Plug : CNN81690B
Jack : CNN82690B
Features:
Applications:
Specifications:
Contacts : made of thermocouple material, plug with standard size solid pins, jacks spring
loaded, contacts polarized
Identification : white bodies marked to IEC or any other standard, polarity marks moulded into body
Ordering code:
Features:
Specifications:
Colour : black
Max. temperature : 90 °C
Features:
Specifications:
Body material : tough, self extinguishing cadmium free thermoplastic compound with low moisture
absorption rate and good dielectric strength
Contacts : fully captive, thermocouple material, plug with flat pins, jacks spring loaded, contacts
polarized
Max. temperature rating : 200°C
Conductor diameter : min. 0,12 mm
max. 0,45 mm
Max. cable diameter : 4,5 mm
Wire terminals : screw type for quick wiring
Identification : plus and minus sign moulded in body; connectors are colour coded to IEC or ANSI
extension wire code
Accessories : each plug/jack will be supplied with a neoprene bush wire grip, code number
CNN-29599; for other accessories see reverse side
Ordering code:
Bushing insert
Material : brass
Thermocouple I 1,0 mm 1,6 mm or 3,2 mm
Each wire clamp bracket delivered with stainless steel mounting screws.
Security clip
Material : stainless steel
Features:
Specifications:
Body material : fibreglass reinforced thermosetting plastic with a good dielectric strength
Contacts : fully captive, thermocouple material, plug with flat pins, jacks spring loaded, contacts
polarized
Max. temperature rating : 350°C
Conductor diameter : min. 0,12 mm
max. 0,6 mm
Max. cable diameter : 4,5 mm
Wire terminals : screw type for quick wiring
Identification : brown bodies, colour marked to IEC or any other standard, polarity mark moulded into
body
Accessories : see reverse side
Bushing insert
Material : brass
Thermocouple I 1,6 mm or 3,2 mm
Ordering code :
I 1,6 mm : CNN29416
I 3,2 mm : CNN29432
blind : CNN29499
Each wire clamp bracket delivered with stainless steel mounting screws.
Features:
Specifications:
Ordering code:
Bushing insert
Material : brass
Thermocouple I 1,6 mm or 3,2 mm
Ordering code :
I 1,6 mm : CNN29416
I 3,2 mm : CNN29432
blind : CNN29499
Each wire clamp bracket delivered with stainless steel mounting screws.
Specifications:
Construction : Plug panel in sheet steel housing with handle and cable clamp
This plug is designed for use with a Thermo Electric vertical standard panel, see I/215
Ordering code:
Specifications:
Specifications:
Ordering code:
Specifications:
Specifications:
Specifications:
Ordering code:
Ordering code:
Features: Applications:
Specifications:
Body material : tough, self extinguishing thermoplastic compound with low moisture absorption rate
and high dielectric strength
Contacts : thermocouple material with screw type terminals, spring loaded and polarized
Maximum temperature rating : 200°C
Conductor diameter : min. 0,12 mm; max. 0,6mm
Panel thickness : 2,3 mm typical
Identification : plus sign moulded in body and front, colour coded to IEC extension wire code, other
colour coding such as IEC, DIN and JIS are also available
Mating connector : standard Thermo Electric's miniature flat pin plug (see datasheet I/120), in
Ordering code:
accordance with European standardization proposal
Ready made panel : see separate datasheets for a complete range of standard panels as well for
extended temperature ratings
Features:
Applications:
Specifications:
Ordering code:
Specifications:
Descriptions: Issues:
Features:
Model : CAL-1502
Temperature range : -200 °C to +962 °C (-328 °F to +1764 °F)
Resistance range : 0 : to 400 : auto ranging
Excitation current : 0,5 and 1 mA (user selectable) 4 Hz
Accuracy : -200 to +100 °C : 0,015 °C +400 to +800 °C : 0,06 °C
+100 to +400 °C : 0,03 °C +800 to +962 °C : 0,08 °C
Temperature resolution : 0,001°
Resistance resolution : 0,0001 :
Temperature coefficient per year : < 2 ppm/°C typical
Display : 8 digit, 7 segment 12,7 mm high LED, °C, °F, K or Ohm
Sample rate : 1 per sec.
Sensor type : 25 : to 100 : Pt, RTD, any alpha, SPRT's
Programming : via front panel key strokes
Probe curve : programmable in indicator
Temperature scale : select read-out according to IPTS-68, ITS-90 or Callendar-Van Dusen
Filter : programmable digital filter, exponential, 0 to 60 seconds time constant
RS-232 interface : included; 1200, 2400, 4800 and 9600 baud
Battery back-up : saves calibration and probe constants during power-off
Operating range : 0 °C to +55 °C
Recommended operating range : 13 to 33 °C
Power supply : 90 to 130 V AC or 180 to 260 V AC, 50/60 Hz (please specify)
Probe connection : 5-pin DIN plugs, 1 included with meter, spares available
Dimensions : 141 x 58 x 178 mm (W x H x D)
Weight : 1 kg
Ordering code:
All standard preset for RTD as per IEC-751 and including TE certificate; RVA certificate at request
ACCESSORIES: see reverse side
Printer:
Add the optional mini-printer to your TWEENER purchase for convenient hardcopy output of your measurements. Plug it into the RS
232 port on the back of the CAL-1502 and you've got a printing data logger. Set a print interval in increments of 1 second through the
front panel of the CAL-1502. The printout gives the temperature with full resolution as displayed on the CAL-1502 with an indicator for
Celsius, Fahrenheit, Kelvin or Ohms. the 20 column thermal printer uses rechargeable NiCad batteries and comes complete with an
AC adaptor/charger. Each printer comes with a roll of paper and a serial cable so you can log precision temperature data soon after
you receive your order.
Software:
In addition, the CAL-1502 is available with a small, easy to use RS 232 communication and data acquisition software package. It
displays temperature in several formats on your PC's screen: bar graph, strip chart of digital display. It also has high and low
temperature alarms. It's written in C language and you get the source code so you can modify the program any way you want.
Calibration set:
The CAL-1502 is available together with a high accurate RTD probe, size to suit your requirements, in a strong case complete with a
NKO certificate of whole set with accuracies up to 0,05 qC or better.
For more details see "Quality assurance kit for autoclave users".
Accessories:
Features:
Model : CAL-1503
Temperature range : -200 °C to +1200 °C
Resistance range : 0 : to 25 : auto ranging
Excitation current : 3 and 5 mA (user selectable)
Accuracy : for 2,5 to 5 : nominal R (0,01 °C) for 0,25 : nominal R (0,01 °C)
-200 to +100 °C : 0,02 °C; +400 to +800 °C : 0,1 °C 0 to 500 °C : 0,25 °C
+100 to +400 °C : 0,05 °C; +800 to +1000 °C : 0,125 °C 500 to 1200 °C : 0,3 °C
+1000 to +1200 °C : 0,15 °C
Temperature resolution : 0,01°
Resistance resolution : 0 to 1 : : 0,00001 :; 1 to 20 : : 0,0001 :
Temperature coefficient per year : < 5 ppm/°C typical
Display : 8 digit, 7 segment 12,7 mm high LED, °C, °F, K or Ohm
Sample rate : 1 per sec.
Sensor type : 0,25 :, 2,5 :, 3 : and 5 : PRT
Programming : via front panel key strokes
Probe curve : programmable in indicator
Temperature scale : select read-out according to ITS-90 or Callendar-Van Dusen
Filter : programmable digital filter, exponential, 0 to 60 seconds time constant
RS-232 interface : included; 1200, 2400, 4800 and 9600 baud
Battery back-up : saves calibration and probe constants during power-off
Operating range : 0 °C to +55 °C
Recommended operating range : 13 to 33 °C
Power supply : 100 to 120 V AC or 200 to 240 V AC, 50/60 Hz (please specify)
Probe connection : 5-pin DIN plugs, 1 included with meter, spares available
Dimensions : 141 x 58 x 178 mm (W x H x D)
Weight : 1 kg
Ordering code:
Printer:
Add the optional mini-printer to your TWEENER purchase for convenient hardcopy output of your measurements. Plug it into the RS
232 port on the back of the CAL-1503 and you've got a printing data logger. Set a print interval in increments of 1 second through the
front panel of the CAL-1503. The printout gives the temperature with full resolution as displayed on the CAL-1503 with an indicator for
Celsius, Fahrenheit, Kelvin or Ohms. the 20 column thermal printer uses rechargeable NiCad batteries and comes complete with an
AC adaptor/charger. Each printer comes with a roll of paper and a serial cable so you can log precision temperature data soon after
you receive your order.
Software:
In In addition, the CAL-1503 is available with a small, easy to use RS 232 communication and data acquisition software package. It
displays temperature in several formats on your PC's screen: bar graph, strip chart of digital display. It also has high and low
temperature alarms. It's written in C language and you get the source code so you can modify the program any way you want.
Calibration set:
The CAL-1503 is available together with a high accurate RTD probe, size to suit your requirements, in a strong case complete with a
NKO certificate of whole set with accuracies up to 0,05 qC or better
Accessories:
CAL-3193 : spare connector
CAL-3194 : data acquisition software
CAL-3195 : mini printer
CAL-3196 : serial cable kit
CAL-3209 : bezel for panel mounting
CAL-1502 : RTD, PRT or SPRT readout or 25 to 100 :
CAL-1504 : thermistor readout, 0 : to 1 M: autorange
Features:
x Large knob
x Robust
x Thermocouple wiring upon request
x Pre-wired internal
x Metal case
x Easy to use
Specifications:
Ordering code:
size 288 x 96 mm
Weight : approx 1,5 kg
06 = 6 points K, J, T, E, R, S, B or 2, P3 (3-wire)
12 = 12 points Cu or P4 (4-wire)
18 = 18 points
23 = 23 points
Options:
We recommend internal wiring of thermocouple material when temperature gradients are expected between terminals and switch
contacts.
All models available for 3 and 4 wire resistance thermometer except SWT-10023 4 wire. When required 3 or 4 wire RTD, specify
P3 or P4 after model number.
Standard and custom built key switches and push buttons switches also available.
Features:
x Compact
x Pre-wired internal
x Panel build-in or table use
x Metal case
x Easy to use
x Different type of indicators available
x Fast response
Specifications:
Ordering code:
SWT - 110 - number of points internal wiring indicator type options (wired to rear)
~ ~ ~
06 = 6 points + off CU = copper 2 wire IDC-18000 see J/201 A - one alarm
12 = 12 points + off P3 = copper 3 wire IDC-17000 see J/205 AA - two alarms
18 = 18 points + off x = thermocouple AAA - three alarms
23 = 23 points + off extension wiring RS - RS232
where applicable SP - special (specify)
Specials:
Rear panel of a SWT-11006-...x-Indicator-special with a 6 standard jack inserts in correct calibration. Power connection (L, N, earth)
with screw terminals, output, screw terminals.
Features:
x High accuracy
x Compact; small size
x Light weight
x 0,1 qC resolution; large range
x Super cooling
x Microprocessor based
x RS 232 included
Applications:
Model : CAL-9140
Temperature range : 33,0 °C to 350,0 °C (92 °F to 662 °F)
Display resolution : 0,1°
Display : actual and setpoint temperature
Control system : PID controller with high stability platinum RTD probe
Accuracy : ± 0,5 (for larger holes than 6,4 mm ± 1 °C)
Stability : ± 0,1 °C below 300 °C; ± 0,2 °C above 300 °C
Heating time : 10 minutes from ambient to 350 °C
Cooling time 350 °C - 100 °C : 10 minutes
Stabilization time : approx. 10 minutes
Uniformity : 0,4 °C typical, 0,1 °C with similar size wells
Insertion length : 124 mm
Interchangeable inserts : one of the following blocks is available
block A : (variety block) 12,7 mm, 9,5 mm, 6,4 mm, 4,8 mm, 3,2 mm and 1,6 mm
block B : (comparison block) 2 x 9,5 mm, 2 x 6,4 mm, 2 x 4,8 mm, 1 x 3,2 mm
block C : (1/4" comparison block) 6 x 6,4 mm
Usage position : horizontal
Enclosure : rugged aluminium
Dimensions : 153 x 86 x 197 mm (H x W x D)
Power supply : 90 to 130 VAC 50/60 Hz or 180 to 260 VAC 50/60 Hz
Carrying case : rugged, ABS tough case with O-ring for water tight closing; foam interior protects dry-
Ordering code:
well and accessories
Weight : 2,3 kg (excluding carrying case)
A, B or C
Features:
x Hand held
x Light weight
x Small size
x 0,1 qC resolution
x Microprocessor based
x Available in 3 versions
Applications:
Specifications:
Model : CAL-9100; complete with TE certificate at 50, 100, 150, 200, 250 and 300 °C
Temperature range : 33 °C to 300 °C (92 °F to 572 °F)
Display resolution : 0,1 °C (or °F)
Display : LED, 14 mm high green LED's, 4 digits
Accuracy : ± 0,5 °C from 33 to 100 °C
± 1 °C from 100 to 300 °C
± 2 °C holes greater than 6,35 mm
Stability : ± 0,2 °C
Heating time : 33 to 300 °C in 9,5 minutes
Stabilization : 3 minutes
Cooling time : 300 to 100 °C in 14 minutes
Hole diameters : block A : 1,6 mm, 3,2 mm, 4 mm, 2x 4,8 mm and 6,4 mm
block B : 3 mm, 4,8 mm, 6,35 mm and 9,5 mm
block C : 4,8 mm and 12,7 mm
Insertion length : 102 mm
Usage position : vertical or under bezel angle
Enclosure : rugged aluminium
Dimensions : 57 x 125 x 150 mm (H x W x D)
Weight : 1,08 kg.
Power supply : 90 to 130 V AC or 180 to 260 V AC, 50/60 Hz
Ordering code:
A, B or C
Options:
The CAL-9100 fits neatly into the large case together with the Fluke 724 , the accurate temperature indicator/calibrator. In this
way you have an accurate measurement unit together with and accurate temperature dry-well calibrator all in one light package.
See datasheet K/151 for more information about the Fluke 724 .
Accessories:
Features:
x Hand held
x Light weight
x Two wells for comparison calibration
x 0,1 qC resolution
x Microprocessor based
Applications:
Specifications:
Model : CAL-9102
Temperature range : -10 °C to 122 °C (-10 °F to 251 °F)
Display resolution : 0,1 °C (or °F)
Display : LED, 14 mm high green LED's, 4 digits
Accuracy : ± 0,5 °C from -10 to +100 °C
± 1,0 °C from 100 to 122 °C
± 2 °C holes greater than 6,35 mm
Stability : ± 0,2 °C
Heating time : 10 minutes, ambient to 100 °C
Stabilization : 5 minutes
Cooling time : 6 minutes, ambient to 0 °C
Wells : 2 piece 12,7 mm wells with removable inserts
Insertion length : 102 mm
Inserts : 6,4 and 4,8 mm included, optional 1,6, 3,2, 8, 9,5 and 11 mm
Usage position : horizontal
Enclosure : rugged aluminium
Dimensions : 83 x 153 x 172 mm (H x W x D)
Weight : 1,8 kg.
Power supply : 90 to 264 V AC (or 12 V DC, 3 A external input)
Ordering code:
CAL - 9102
Accessories:
Features:
Applications:
Model : CAL-9103
Range : -25 °C to +125 °C
Display resolution : 0,1q
Display : actual and set-point temperature
Control system : PID controller with high stability platinum RTD probe
Stability : ± 0,1 °C
Accuracy : ± 0,5 °C (r 1qC for larger holes than 6,4 mm)
Uniformity : ± 0,3 °C typical (r 0,1qC with similar size wells)
Display scale : qC or qF switchable
Heating time : 6 minutes from ambient to 100qC
Cooling time : 8 minutes from 100q to ambient
Stabilisation time : approx. 7 minutes
Insertion length : 124 mm
Interchangeable inserts : one of the following blocks is available
block A : (variety block) 12,7 mm, 9,5 mm, 6,4 mm, 4,8 mm, 3,2 mm and 1,6 mm
block B : (comparison block) 2 x 9,5 mm, 2 x 6,4 mm, 2 x 4,8 mm
block C : (1/4” comparison block) 6 x 6,4 mm
Usage position : vertical
Enclosure : rugged aluminium
Dimensions : 261 x 143 x 245 mm (H x W x D)
Power supply : 94 to 234 V AC; 50/60 Hz
Weight : 5700 g (excl. carrying case)
Ordering code:
Accessories:
Features:
x High accuracy
x Compact; small size
x Light weight
x 0,1 qC resolution; large range
x Super cooling
x Microprocessor based
x RS 232 included
Applications:
Specifications:
Model : CAL-9141
Temperature range : 50 °C to 650 °C (122 °F to 1202 °F)
Display resolution : 0,1°
Display : actual and setpoint temperature
Control system : PID controller with high stability platinum RTD probe
Accuracy : ± 0,5 for 50 to 440 °C; ± 1 for 440 to 650 °C;
for larger holes than 6,4 mm ± 2 °C
Stability : ± 0,1 °C below 300 °C; ± 0,2 °C above 300 °C
Heating time : 12 minutes from ambient to 650 °C
Cooling time 650 °C - 100 °C : 25 minutes
Stabilization time : approx. 10 minutes
Uniformity : 0,3 °C 50 to 440 °C typical; 0,5 °C with similar size wells
Insertion length : 124 mm
Interchangeable inserts : one of the following blocks is available
block A : (variety block) 12,7 mm, 9,5 mm, 6,4 mm, 4,8 mm,3,2 mm and 1,6 mm
block B : (comparison block) 2 x 9,5 mm, 2 x 6,4 mm, 2 x 4,8 mm
block C : (1/4" comparison block) 6 x 6,4 mm
Usage position : vertical
Enclosure : rugged aluminium
Dimensions : 229 x 114 x 178 mm (H x W x D)
Power supply : 90 to 130 VAC 50/60 Hz or 180 to 260 VAC 50/60 Hz
Carrying case : rugged, ABS tough case with O-ring for water tight closing; foam interior protects dry-
well and accessories
Ordering code:
Weight : 3,6 kg (excluding carrying case)
153 x 86 x 197 mm
Accessories:
Features:
x High accuracy
x Light weight
x Three test wells
x Solid state cooling technology
x Microprocessor based
Applications:
Specifications:
Model : CAL-9101
Temperature range : fixed 0 °C
Green "ready" LED : indication of stable control at 0 °C
Control system : precision controller with recalibration possibility; solid state cooling technology
Accuracy : d 00,5 °C
Stability : ± 0,01 °C / 10 minutes
Drift : ± 0,005 °C/°C ambient (from 22 °C)
Operable temperature range : 5 to 27 °C
Accuracy temperature range : 18 to 25 °C
Stabilization time : approx. 30 minutes
Recalibration setpoint : adjustable
Insertion length : 152 mm
Insert hole diameter : 6,37 mm (2x) and 7,13 mm (1x) this hole includes telescoping inserts to
accommodate various smaller diameters
Usage position : horizontal
Number of insert holes : 3
Enclosure : rugged aluminium
Dimensions : 146 x 216 x 311 mm (H x W x D)
Carrying case : rugged, ABS tough case with O-ring for water tight closing; foam interior protects dry-
well and accessories
Power supply : 220/230 V AC (unless otherwise specified)
Weight : 6 kg
Ordering code:
CAL - 9101
Options:
x For laboratory and industrial temperature reference standards see sheet L/400, L/410, L/420, L/430, L/440 or L/450.
x For special requirements or other calibration equipment contact Thermo Electric.
Accessories:
Features:
x Hand held
x Black body
x Light weight
x 0,1 qC resolution
x Small size
x Microprocessor based
Applications:
Model : CAL-9131
Temperature range : 33,0 °C to 400,0 °C (92 °F to 752 °F)
Display resolution : 0,1°
Display : actual and setpoint temperature
Control system : PID controller
Accuracy : ± 1 °C to 100 °C
± 2 °C to 250 °C
± 3 °C to 400 °C
Stability : ± 0,2 °C at 33 to 200 °C
± 0,3 °C at 200 to 300 °C
± 0,4 °C at 300 to 400 °C
Stability time : 3 minutes to max
Emissivity : 0,95
Heating time : 15 minutes (depending on setpoint)
Cooling : via built-in fan
Cooling time 400 °C - 100 °C : 25 minutes
Target size : 25 mm
Target type : concentric machined rings
Reference well o.d. : 3,2 mm drilled int he target (access from above)
Usage position : horizontal
Enclosure : rugged aluminium
Dimensions : 57 x 125 x 150 mm (H x W x D)
Power supply : 90 to 130 VAC 50/60 Hz or 180 to 260 VAC 50/60 Hz
Carrying case : rugged, ABS tough case with O-ring for water tight closing; foam interior protects dry-
well and accessories
Weight : 1,08 kg
Ordering code:
CAL - 9131
Options:
Accessories:
Features:
Applications:
Specifications:
Model : CAL-9122
Temperature range : +35 °C to +600 °C
Display resolution : 0,01 °C
Display : LED, value and °C
Accuracy : center well ± 0, 1°C to 200 °C; ± 0,2 °C 200 to 400 °C; ± 0,6 °C 400 to 600 °C
Stability : ± 0,02 °C at 100 °C; ± 0,03 °C at 300 °C; ± 0,05 °C at 600 °C
Uniformity : ± 0,05 °C (between sensors)
Controller operation : see reverse side
Heating time : approx. 30 minutes
Cooling : via built-in cooling fan
Insertion length : 152 mm
Test well : five 6,4 mm holes and four 19,05 mm holes for inserts as mentioned on rear page
Inserts : four inserts are supplied as standard with holes for sensors with o.d. of 3,2 mm,
4,8 mm, 6,4 mm and 12,7 mm
Usage position : vertical
Enclosure : rugged aluminium
Dimensions : 318 x 203 x 267 mm (H x W x D)
Power supply : 220 V AC ± 15% (unless otherwise specified)
Weight : 10,5 kg
Ordering code:
Technical:
Controller operation : well temperature, reset cut-out, temperature set point, temperature hold mode, ramp and
soak programs, secondary menu, heater power, proportional band, cut-out, temperature
display hold, controller configuration, probe parameters menu, operating parameters,
serial interface parameters, IEEE-488 parameters, calibration parameters
Options:
x 19,05 mm outside diameter inserts. User specified insert. The standard size is machined larger than the given probe diameter to
allow proper fitting. However when ordering custom inserts you must specify the exact diameter of your element. Holes will be
drilled according list:
IMPERIAL METRIC
Probe size (") Hole size (mm) Probe size (mm) Hole size (mm)
1/16 1,9 3,5 3,7
1/8 3,5 4,8 5,0
3/16 5,0 5,0 5,2
1/4 6,6 5,2 5,5
5/16 8,2 6,0 6,3
3/8 9,8 6,5 6,8
7/16 11,6 7,0 7,4
1/2 13,1 7,8 8,1
9/16 14,7 8,0 8,3
5/8 16,3 8,5 8,8
11/16 17,9 9,5 9,8
12,7 13,0
17,0 17,5
x large test well (instead of the 9-hole block) a 43 mm o.d. and 152 mm deep hole can be supplied
x °F unit (68°F to 1112°F) with 0,01°F resolution.
x IEEE 488 interface for computer controlled operation.
x Individual sensor calibration system, the CAL-9931, for thermocouples and RTD certification.
x RVA calibration instead of TE standard calibration
Accessories:
CAL-3187 : insert without holes (19,05 mm o.d., blank)
CAL-3190 / ... : insert with dimensions to be specified out of list above
CAL-3191 : extremely durable carrying case, ideal for transport, when recalibration is required
Features:
Applications:
Specifications:
Model : CAL-9105
Temperature range : -25 °C to +140 °C (at ambient of 25 °C)
Display resolution : 0,01 °C
Display : LED, value and °C
Accuracy : ± 0,05 °C with reference; ± 0,1 °C without reference at 0 °C
± 0,23 °C at -20 °C; ± 0,45 °C at 140 °C for center well
Stability : ± 0,02 °C
Uniformity : ± 0,05 °C (between drilled well),
for inserted well ± 0,23 °C at -20 °C; ± 0,08 °C at 0 °C; ± 0,4523 °C at +140 °C
Controller operation : see reverse side
Thermal switch : start heating or cooling cycle
Insertion length : 152 mm
Test well : five drilled test wells; two of 6,4 mm holes, one of 3,2 mm hole, on of 4,8 mm hole
and one test well insert (19,05 mm) with 6,5 mm inside diameter
Usage position : vertical
Communication : RS 232 standard supplied on the unit; IEEE interface possible as option
Heating/cooling rate : takes only 8 minutes to reach any setting
Enclosure : rugged aluminium
Dimensions : 343 x 198 x 330 mm (H x W x D)
Power supply : 220 V AC ± 15% (unless otherwise specified)
Weight : 12 kg
Ordering code:
Technical:
Controller operation : well temperature, reset cutout, temperature set point, temperature hold mode, ramp and
soak programs, secondary menu, heater power, proportional band, cutout, temperature
display hold, controller configuration, probe parameters menu, operating parameters, serial
interface parameters, IEEE-488 parameters, calibration parameters
Options:
x 19,05 mm outside diameter inserts. User specified insert. The standard size is machined larger than the given probe diameter to
allow proper fitting. However when ordering custom inserts you must specify the exact diameter of your element. Holes will be
drilled according list:
IMPERIAL METRIC
Probe size (") Hole size (mm) Probe size (mm) Hole size (mm)
1/16 1,9 3,5 3,7
1/8 3,5 4,8 5,0
3/16 5,0 5,0 5,2
1/4 6,6 5,2 5,5
5/16 8,2 6,0 6,3
3/8 9,8 6,5 6,8
7/16 11,6 7,0 7,4
1/2 13,1 7,8 8,1
9/16 14,7 8,0 8,3
5/8 16,3 8,5 8,8
11/16 17,9 9,5 9,8
12,7 13,0
17,0 17,5
x large test well (instead of the 9-hole block) a 43 mm o.d. and 152 mm deep hole will be supplied.
x qF unit (-32 qF to +248 qF) with 0,01 qF resolution.
x IEEE 488 interface for computer controlled operation.
x Individual sensor calibration system, the CAL-9931, for thermocouples and RTD certification.
x RVA calibration instead of TE standard calibration
Accessories:
CAL-3191 : extremely durable carrying case, ideal for transport, when recalibration is required
CAL-3197 / ... : blank insert / user specified insert with dimensions to be specified out of the list on
rear page
CAL-9930 : software package also usable for CAL-9122 and CAL-9123 to control the unit via a
PC (needs windows 3.1 and IBM compatible PC with VGA screen)
Features:
Applications:
Specifications:
Model : CAL-9150
Temperature range : +150 °C to +1200 °C (302 °F to 2192qC)
Display resolution : 0,1 °C or °F to 999,9°, above 1° resolution
Display : green LED’s, value and °C
Accuracy : ± 4 °C (7,2 °F)
Stability : ± 0,3 °C
Uniformity : ± 0,3 °C well to well (insert C at 1200 °C)
Controller operation : see reverse side
Heating time : approx. 35 minutes to maximum
Cooling time : 140 minutes with block
Stabilization time : 20 minutes
Insertion length : 102 mm
Well diameter : 32 mm
Interface : serial RS 2323 standard, IEEE optional
Usage position : vertical
Enclosure : rugged aluminium
Dimensions : 305 x 191 x 280 mm (H x W x D)
Power supply : 115 V AC or 230 V AC ± 10%
Weight : 13 kg
Ordering code:
Technical:
Controller operation : well temperature, reset cut-out, temperature set point, temperature hold mode, ramp and
soak programs, secondary menu, heater power, proportional band, cut-out, temperature
display hold, controller configuration, probe parameters menu, operating parameters,
serial interface parameters, IEEE-488 parameters, calibration parameters
Accessories:
Features:
Applications:
Specifications:
Model : CAL-6102
Range : +35 °C to +200 °C
Stability : ± 0,015 °C to 100 °C; ±0,03 °C above 100 °C
Accuracy : ± 0,5 °C
Uniformity : ± 0,02 °C
Resolution : 0,01 °C/°F
Operating temperature : 5 °C to 45 °C
Heating time 25-200 °C : 25 minutes
Cooling time 200-100 °C : 35 minutes
Temperature setting : digital display with push button date entry
Controller : hybrid analogue/digital controller with data retention
Bath volume : 1,6 liter
Wetted parts : 304 SS, case material: aluminium
Computer interface : RS 232 included with Windows software
Well size : 63,5 mm dia. x 139 mm deep
Dimensions : 264 x 140 x 203 mm (H x W x D)
Heater : 360 Watt
Power supply : 230 V AC ± 10% 50/60 HZ or 115 V AC ± 10% 50/60 HZ; switchable
Weight : 3200 g (excl. oil)
Ordering code:
CAL - 6102
Options:
General:
The model CAL-6102 is truly portable bath, which makes it the perfect calibration instrument for just any sized temperature
sensor. Its 130 mm deep stirred temperature well is stable to within ± 0,03 °C over its range of ambient to 200 °C. It works great
for large diameter, short stem, liquid-in-glass, or odd shaped probes that are difficult to calibrate in a dry-well. The diameter of the
tank is 63,5 mm, so you can immerse almost any size sensor. There is no need to drain the tank fluid before you carry this micro-
bath to another location. Simply screw the o-ring sealed lid onto the tank and transport it spill-free.
Accessories:
Features:
Applications:
Specifications:
odel : CAL-7102
Temperature range : -5 °C to 125 °C (23 °F to 257 °F)
Display resolution : 0,01 °C or °F
Display : green LED’s, value and °C
Accuracy display : ± 0,4 °C (± 0.7 °F)
Stability : ± 0,015 °C (0.036 °F) with water, ± 0.03 °C (± 0.05 °F) with 200.05 oil
Uniformity : 0,02°C (± 0.036 °F)
Operating temperature : 5 °C to 45 °C (41 °F to 113 °F)
Controller operation : see reverse side
Temperature setting : digital with push button data entry
Controller : hybrid analogue/digital controller with data retention
Heating time : 25 °C to 100 °C 30 minutes (77 °F to 212 °F)
Cooling time : 30 minutes from 25 °C to 0 °C (77 °F to32 °F)
Insertion depth : 139 mm
Bath diameter : 64 mm (2.5”)
Bath volume : 1,6 litre
Wetted parts : 304 SS
Interface : serial RS 232 standard, IEEE optional
Usage position : vertical
Enclosure : rugged aluminium
Dimensions : 180 mm x 310 mm x 240 mm
Power supply : 115 VAC or 230 VAC ( ± 10 % )
Weight : 6800 g (with fluid )
Ordering code:
Technical:
Controller operation : well temperature, reset cut-out, temperature set point, temperature hold mode, ramp and
soak programs, secondary menu, heater power, proportional band, cut-out, temperature
display hold, controller configuration, probe parameters menu, operating parameters,
serial interface parameters, IEEE-488 parameters, calibration parameters
General:
The model CAL - 7102 is truly a portable bath, which makes it the perfect calibration instrument for just any sized temperature
sensor. Its 130 mm deep stirred temperature well is stable to within ± 0.015°C with water to 90 °C. It works great for large
diameters, short stem, liquid in glass or odd shaped probes that are difficult to calibrate in a dry-well. The diameter of the tank is
63.5 mm, so you can immerse almost any size sensor.
There is no need to drain the tank fluid before you carry this micro bath to an other location. Simple screw the O-ring sealed lid
onto the tank and transport it spill-free.
Accessories:
Descriptions: Issues:
x Hand held digital thermometer single or dual, type TE-3003 or TE-3004 K/140 Rev.00 08/03
x Hand held digital thermometer 4 thermocouple input’s, type Fluke 51,52,53
and 54 K/141 Rev.00 08/03
x Hand held thermocouples K/145+r Rev.00 08/03
x Hand held digital RTD simulator and calibrator (Pt100), type Fluke 712 K/146 Rev.00 08/03
x Hand held digital Thermocouple simulator and calibrator, type Fluke 714 K/147 Rev.00 08/03
x Hand held digital mA ,mV and V simulator and calibrator, type Fluke 715 K/150 Rev.00 08/03
x Hand held digital all ranges simulator and calibrator, type Fluke 724 K/151 Rev.00 08/03
x Autotemp junior; SCA-23012 K/519+r Rev.00 08/03
Features: Applications:
Specifications:
Ordering code:
Dimensions:
148 x 71 x 36 mm
Features:
Features: Applications:
Specifications:
Note: only the FLUKE models 53II and 54II are capable of measuring N,R and S
type thermocouples.
Ordering code:
Dimensions:
173 x 86 x 38 mm
Ranges :
J= -210 to 1200ºC
K= -200 to 1372ºC
T= -250 to 400ºC
E= -150 to 1000ºC
N= -200 to 1300ºC
R= 0 to 1767ºC
S= 0 to 1767ºC
Accessories:
Specifications:
Ordering code:
SURFACE PROBE:
tip detail:
HHP-50151: 4,8 mm o.d.
500 °C*
200 °C*
NEEDLE PROBE:
tip detail:
HHP-40081: 1,5 mm o.d.
HHP-40181: 3,0 mm o.d.
500 °C*
Ordering code:
AIR PROBE:
tip detail:
HHP-20051: 6 mm o.d.
500 °C*
850 °C*
500 °C*
600 °C*
260 °C*
HHP-71001
150 °C*
Features: Applications:
Specifications:
Ordering code:
Dimensions:
Accessories:
Features: Applications:
Specifications:
Ordering code:
Dimensions:
Accessories:
Features: Applications:
Specifications:
Ordering code:
Dimensions:
Features: Applications:
Specifications:
Models : 724
Input(s) : J, K, T, E, N, L, Platinel II, R, S, B, Pt100
(2, 3 and 4-wire), Ohms, mV
Ranges : see overleaf
Accuracy : see overleaf
Resolution : 0,1° on temperature ranges, 0,01 Ohms
and 0,001 for mV
Display : 2 lines of 16 alphanumeric characters, 5 x
7 dot matrix LCD
Display update rate : 2 updates per second
Ambient temp. operating range : 0 °C to 55 °C
Storage temp. Range : -20 °C to 70 °C
Normal mode rejection rate : t 50 dB at 60 Hz
Common mode rejection rate : 150 dB with AC adapter at 60 Hz
Temperature stability : 15 ppm of reading/degree (max.)
Input/output resolution : temperature sensors/ranges 0,1 °C
mV: 0,001 mV; RTD: 0,1°; Ohms: 0,01
Input impedance : 100 M:
Input leakage current : < 10 nA
Case material : polycarbonate
Cover material : polypropylene
Membrane keypad material : polycarbonate
Output impedance : d 0,005 Ohms
Output drive capability : 45: fixed load at 100 mV output, 35: at 80
mV, 15: at 40 mV, 10: at 25 mV
Max. RTD output excitation current : 2 mA
Max. RTD lead resistance : 4-wire 300 :, 3-wire 150 :
RTD input excitation current : 1 mA
Power supply : 6 disposable AA batteries or AC adapter
Dimensions (L x W x D) : 220 x 95 x 60 mm
Weight : 800 g
Ordering code:
Fluke 724
Features:
x Portable - robust
x 12 Volt DC operation
x LED indication of temperature
x 12 thermocouple channels
x Available in K or J calibration
Applications:
Specifications:
Ordering code:
BUSHING INSERT
Material mm : brass
Thermocouple o.d. : 1,0 mm, 1,6 mm or 3,2 mm
Ordering code 1,0 mm : CNN-29510
1,6 mm : CNN-29516
3,2 mm : CNN-29532
Descriptions: Issues:
x Laboratory temperature reference standard, SPRT Pt100; CAL-40634 L/400 Rev.00 08/03
x Laboratory temperature reference standard, SPRT Pt25,5; CAL-40635 L/410 Rev.00 08/03
x Laboratory temperature reference standard, S t/c type; CAL-40636 L/420 Rev.00 08/03
x Industrial temperature reference standard, IPRT Pt100; CAL-40637 L/430 Rev.00 08/03
x Industrial temperature reference standard, S t/c type; CAL-40638 L/440 Rev.00 08/03
x Industrial temperature reference standard, K t/c type; CAL-40595 L/450 Rev.00 08/03
Features:
Specifications:
Ordering code:
CAL - 40634
Features:
Specifications:
Ordering code:
CAL - 40635
Features:
Specifications:
CAL - 40636
Features:
Specifications:
Ordering code:
CAL - 40637
Features:
x Easy to use
x Supplied with certificate
x For comparison construction
x Long life construction
x Includes carrying case
Specifications:
Ordering code:
CAL - 40638
Features:
Specifications:
Temperature range : 0 to +1050 °C
Thermocouple : chromel-alumel
EmF vs temperature : IEC 584-1
Accuracy : according IEC 584-2 class 2
Probe diameter : 6,4 mm
Probe length : 560 mm
Immersion depth : from 150 to 450 mm
Grip material : aluminium
Max. grip temperature : 50°C
Sheath material : Inconel 600
Cable : flexible armour with teflon insulated
compensated extension leads
Cable length : 2 meters
Termination : compensated standard connector
Certification : Thermo Electric RVA certificate with full
calibration over the range (1° increment
table) ITS 90
Calibration : once per year or sooner, depending on
the usage frequency, time and
temperature
Packaging : strong case size ± 750 x 250 x 100, with
foam inlay
Weight : ± 650 gram (excluding case)
Ordering code:
CAL - 40595
Descriptions: Issues:
x Quality Résumé, with a Quality Management System certificated to ISO-9001:2001 M/001+r Rev.0 08/03
x Specifications
QUALITY OBJECTIVE
Thermo Electric’s policy is to empower the organization and all its employees to ensure that the products and services
are of the highest quality and meet or exceed the requirements of customers.
QUALITY EXPERIENCE
With over 45 years of quality related experience, the THERMO ELECTRIC QA staff is ready to meet your most
demanding quality requirements.
QUALITY PROGRAM
Thermo Electric has implemented and maintains a Quality -Management System which meets the requirements of NEN-
EN ISO-9001:2000 to ensure the following:
Thermo Electric has an RvA accredited Temperature Calibration Laboratory and therefore can provide calibration
services to meet the most exacting requirements. The Nederlandse Kalibratie Organisatie, NKO (Netherlands Calibration
Service) is an accreditation system for measurement and calibration laboratories, merged in the Raad voor de
Accreditatie, RvA (The Dutch Council for Accreditation)
The laboratories applying for accreditation are assessed according criteria laid down on a European level (EN 45001 and
ISO/IEC Guide 25). An RvA-accredited laboratory has a superior QA system, the measurements are carried out
according to agreed procedures and the measurement values are traceable to (inter-)national standards, which is an
essential requirement to meet ISO-9000 and other criteria. Within the range of an accreditation, the RvA-accredited
laboratories are allowed to present the results of their calibrations on a certificate with the registered RvA-logo at the top
of each page. An RvA calibration certificate issued by Thermo Electric guarantees the international traceability of
measuring values according to recognised international standards.
On top of that Thermo Electric offers a large range of calibration furnaces and baths, which can have of course RvA
certification.
Thermo Electric insulated thermocouple wire is carefully calibrated and is traceable to the National Institute for Standards
and Technology (NIST) for conformance to ISA and ANSI recommended initial calibration tolerances. These top quality
wire & cable products are designed and manufactured to meet the demands of industry. Certification of both conductors
and construction can be supplied.
TOTAL APPROACH
Thermo Electric’s program consists of a range of products which provides a total approach to temperature technology:
a. Thermocouple sensors; k. Thermocouple wire; s. Temperature controllers;
b. Resistance thermometers; l. Thermocouple extension wire and t. Temperature systems;
c. Thermowells; cable; u. Cold-junction compensators and
d. Thermistor sensors; m. Instrument wire and cable (300V); systems;
e. Multipoint sensors; n. Control - Power cable (600V); v. Switches;
f. High pressure sensors; o. Connectors/Panels, connection w. Temperature transmitters;
g. Profiling sensors; systems; x. Temperature scanning systems;
h. Lloyds/Veritas approved sensors; p. Junction boxes; y. Calibration sensors, calibration
i. Atex approved sensors; q. Portable indicators and calibrators; furnaces, calibration baths;
j. Sensor connectors and r. Temperature indicators; z. Calibrators
accessories;
SERVICES
Thermo Electric’s total approach in temperature technology is being supported by services:
a. Calibration Laboratory (fully conditioned)
b. Engineering Services (Design; Drafting; Calculations)
c. Complete range of Test Facilities (e.g. Pressure testing; I.R. testing; Liquid nitrogen testing)
d. Certification Services (e.g. Material Certificates; Certificate of Conformance; Explosion Proof Certificates)
SPECIFICATIONS
Thermo Electric is prepared to meet a variety of commercial, military and other specifications. We conform to the
following:
INTERNATIONAL STANDARD DEFINITION
ISO-9001:2000 Quality System - Model for QA in Production and Installation, LRQA number
657061
SPECIFICATIONS DEFINITION
ANSI MC-96.1 Temperature Measurement: Thermocouples
IEC-584 part 1 to 3 Temperature Measurement: Thermocouples
ASTM E 585 Metal Sheathed Thermocouples
IEC-751 Industrial Platinum Resistance Thermometer Sensors
ASME IX Boiler and Pressure Vessel Code
STOOMWEZEN part 1 to 3 Rules for Pressure Vessels
EN-50014 Electrical Apparatus for Potentially Explosive Atmospheres
EN-50018 Electrical Apparatus for Potentially Explosive Atmospheres EEx d
EN-50019 Electrical Apparatus for Potentially Explosive Atmospheres EEx e
EN-50020 Electrical Apparatus for Potentially Explosive Atmospheres EEx i
LLOYD’s REGISTER OF SHIPPING Thermocouples and RTD Elements
BUREAU VERITAS Thermocouples and RTD Elements
IEEE 383 Flame Retardency
FDA Approval Food & Drug Association
NEC 725 Intrinsical safety for wire & cable
EN-50039 Intrinsical safety for wire & cable
UL UL Listed
MIL-I-45208A Inspection System Requirements
MIL-STD-45662A Calibration System Requirements
MIL-STD-105E Sampling Procedure for Inspection
MIL-H-6875G Special Calibration Tolerances
Features:
Confidence in calibrations
Quality
The provision of competent calibration and traceable measurements are often essential requirements for achieving the high levels
of quality expected of manufacturers in today's modern industrial environment and can be a critical factor in obtaining and
maintaining ISO 9000 certification. In addition, demonstrable proof of competence in these areas can be a major criteria in
addressing issues of product liability. The credibility of test results depends on accuracy, precision and repeatability, the provision
of which is dependant upon the competence of the laboratory providing these services and the validity of the methods used.
Customers and users of calibration services must therefore have confidence that the providers of these services are competent
and that the results achieved are recognisable valid by both external inspection bodies and their own customers alike. Every
supplier of calibration services claims to be the best which can make the choice difficult and the way to be sure of satisfying these
requirements is to use an accredited laboratory.
Services
Thermo Electric has a NKO accredited Temperature calibration laboratory and can therefore provide calibration services to meet
the most exacting requirements.
Accreditation system
The Nederlandse Kalibratie Organisatie, NKO (Netherlands Calibration Service) is an accreditation system for measurement
and calibration laboratories, merged in the Raad voor de Accreditatie, RvA (The Dutch Council for Accreditation)
The laboratories applying for accreditation are assessed according criteria laid down on a European level (EN 45001 and ISO/IEC
Guide 25). An RvA-accredited laboratory has an adequate quality assurance system, the measurements are carried out
according to agreed procedures and the measurement values are traceable to (inter-)national standards, which is an essential
requirement to meet ISO-9000 and other criteria. Within the range of an accreditation, the RvA-accredited laboratories are
allowed to present the results of their calibrations on an certificate with the registered RvA-logo at the top of each page.
Traceability guaranteed
An RvA calibration certificate guarantees the international traceability of measuring values according to recognised international
standards and each certificate carries the RvA logo.
Please see overleaf measuring ranges and the optimum measurement capabilities.
TEMPERATURE
resistance selfind. thermometers and temp.
Range thermocouples thermometers sensors with transmitters
-195 qC 0,084 qC 0,02 qC 0,02 qC
0 qC 0,048 qC 0,012 qC 0,011 qC
0,01 qC 0,047 qC 0,007 qC 0,004 qC
26,868 qC 0,047 qC 0,009 qC 0,006 qC
122,33 qC 0,047 qC 0,026 qC 0,011 qC
-15 qC to 90 qC 0,084 qC 0,074 qC 0,071 qC
90 qC to 150 qC 0,092 qC 0,074 qC 0,071 qC
150 qC to 200 qC 0,094 qC 0,087 qC 0,084 qC
200 qC to 630 qC 0,14 qC 0,13 qC 0,13 qC
630 qC to 1050 qC 1,2 qC 1,1 1,2 qC
TRANSMITTERS
Range Pt100 input t/c type K
-200 qC to 850 qC 0,087 qC -
-270 qC to 1372 qC - 0,13 qC
ELECTRICITY
Range DC Voltage DC Current DC Resistance
-6
1 PV to 100 mV 410 U + 2 PV - -
-6 -6
100 mV to 1 V (410 - 4,610 )U + 2 PV - -
-6 -6
1 V to 10 V (4,610 - 5510 )U + 2 PV - -
-6
100 PA to 1 mA - 110 I + 8,5 PA -
-5
1 mA to 10 mA - 110 I + 8,5 PA -
-5 -4
10 mA to 50 mA - (110 - 110 )I + 8,5 PA -
-6
0,01 : to 10 : - - 110 R + 3 m:
-6 -5
10 : to 100 : - - (110 - 110 )R + 3 m:
-6 -6
100 : to 1 k: - - (110 - 3110 )R + 4 m:
-5 -5
1 k: to 10 k: - - (110 - 2,110 )R + 25 m:
The calibrations are carried out at an ambient temperature of 23 qC nominal. The best measurement capability : the highest achievable
accuracy for a given measuring point or measuring range, expressed as the total positive and negative measurement uncertainty. The
measurement uncertainty is calculated according to WECC Doc. 19 "Guidelines for the expression of the uncertainty of measurement in
calibrations". The list with the scope of accreditations has only a relation with calibration performed within the laboratory.
Descriptions: Issues:
x Mi-cable metal sheathed ceramic insulated thermocouple wire N/001 Rev.00 08/03
x Sheath material N/002 Rev.00 08/03
Specifications:
MI-CABLE is especially designed for use in the manufacture of thermocouples. Densely packed magnesium oxide (MgO)
powder insulates the carefully selected, matched, calibrated pair of thermocouple wires. The insulated wires are then
surrounded by a tight fitting, protective metal sheath for maximum environmental and mechanical protection.
Although basically rigid, to withstand the rigors if industrial usage, MI-CABLE can be formed to fit installations where straight
thermocouples cannot be used. It can be bent to a radius as small as twice its outside diameter, without affecting the
performance or accuracy of the sensor. This combination of ruggedness and flexibility provides a life span many times
greater than bare or insulated wire type thermocouples.
Whatever your application, there is a MI-CABLE construction available to meet it. Using just the standard sheaths and ranges
listed in this catalogue section, there are over 320 constructions available. In each case, they offer the right combination of
properties necessary to do the job in an economical and efficient manner.
Chart I
Ordering Sheath Max. temp. Melting Application notes
symbol material (cont. service, air) range
Mi-304 SS 304 1750 qF 2550-2650 qF The general purpose austenitic stainless steel. Subject to carbide
precipitation in the 900 to 1600 qF range. Corrosion resistant in the
annealed condition. Not affected by sterilizing solutions, foodstuffs,
most dyestuffs, organic and many inorganic chemicals.
Mi-310 SS 310 2100 qF 2550-2650 qF Very high elevated temperature strength and scale resistance.
Superior to 304 in many high temperature applications. Good
resistance to carburizing and reducing environments. Subject to
carbide precipitation in the 900 to 1600 qF range.
Mi-316 SS 316 1650 qF 2500-2550 qF Higher corrosion resistance than type 304. High creep strength.
Withstands sulfuric acid compounds, resists tendency to pit in
phosphoric and acetic acids. Subject to carbide precipitation in the
800 to 1500 qF range.
Mi-347 SS 347 1600 qF 2550-2600 qF Columbium stabilized grade intended to prevent harmful precipitation
of chromium carbides and the resulting susceptibility to intergranular
corrosion. For corrosion conditions and intermittent heating and
cooling applications between 800 qF and 1500 qF.
Mi-I600 Inconel* 600 2100 qF 2500-2600 qF Good in severely corrosive environments at elevated temperatures.
High hot-strength and resistance to progressive oxidation and fatigue.
Non magnetic. Use in sulfur free atmosphere.
Mi-HX Hastelloy** X 2200 qF 2350 qF Nickel, chromium iron and molybdenum alloy.
Mi-P 10 R platinum 10% 2500 qF 3370 qF Addition of rhodium increases service temperature, strength and
rhodium approx. corrosion resistance.
Mi-TA tantalum not recommended 5425 qF Useful to 4000 qF in inert gas or in a vacuum.
Other materials that can be made into tubing can be used for sheath material.
* Trademark, International Nickel Co., Inc. ** Trademark, Union Carbide Corp.
Chart II o.d. min. min. max.
tolerances conductor size insulation sheath length
Diameter: Select a thermocouple ordering nominal od nom. min. thickness thickness
diameter from the chart II. Larger sizes symbol (inches) + - (AWG) (inches) (inches) (inches) (feet)
generally yield longest life and greater
125 1/25 (.040) .0015 .001 36 .005 .004 .006 50
strength; smaller sizes have faster 116 1/16 (.0625) .0015 .001 30 .010 .005 .009 100
response. Sizes shown a re for two wire 332 3/32 (.094) .002 .002 26 .015 .006 .010 100
construction only. Duplex and other 18 1/8 (.125) .0015 .001 24 .020 .012 .012 100
special constructions are available. 316 3/16 (.1875) .0015 .001 20 .031 .022 .020 50
Contact your local TE representative or 14 1/4 (.250) .002 .002 18 .040 .025 .028 50
write Thermo Electric in the Netherlands 516 5/16 (.3125) .003 .002 15 .057 .030 .037 49
for details. 38 3/8 (.375) .003 .002 14 .064 .035 .045 36
716 7/16 (.4375) .005 .005 12 .077 .040 .050 28
Chart III Select calibration providing highest sensitivity for your temperature range, or that matches your instrumentation
Sensitivity
Ordering Temp. range qF (average change Limits of error Conductor identification
symbol per qF in PV) standard special* Positive (+) Negative (-)
J 32 to 530 30 ± 4 qF ± 2 qF magnetic non magnetic
530 to 1400 32 ± ¾% ± _%
T -300 to -75 14 ± 2% ± 1% copper colour non magnetic
-150 to -75 17 ± 1-½ qF ± 1% non magnetic
-75 to +200 22 ± ¾% ± ¾ qF
200 to +700 30 ± _%
K 32 to 530 23 ± 4 qF ± 2 qF non magnetic magnetic
530 to 2300 22 ± ¾% ± _%
E 32 to 600 39 ± 3 qF ± 2¼ qF non magnetic silver colour
600 to 1600 44 ± ½% ± _% non magnetic
S, R 32 to 1000 5 ± 2,5 qF softer than positive
1000 to 2700 7 ± ¼% conductor
LIMITS of error per ASA C96.1-1969 / IEC 584 Percentages refer to the temperature being measured.
* To specify special limits of error, use a double calibration symbol, e.g.: JJ
Type T, Copper(+)-Constantan(-), is commonly used for sub-zero to 700 qF temperatures. preferred to type J fr sub-zero applications
because of copper's high moisture resistance, as compared to iron. If unprotected, it will still function in a vacuum, inert, oxidizing or
reducing atmosphere.
Type K, Chromel(+)-Alumel*(-), is generally used to measure high temperature to 2300 qF. It should not be used for accurate
temperature measurements below 900 qF after prolonged exposure above 1400 qF. If unprotected, it can be used only in inert or
oxidizing atmosphere. It has a short life in alternately oxidizing and reducing atmospheres, and in reducing atmospheres, particularly
in the 1500 to 1850 qF range.
Type E, Chromel*(+)-Constantan(-), has the highest emf output of any standardized metallic thermocouple. If used unprotected, type
E wires are not subject to corrosion at sub-zero temperatures. They can be used in inert, oxidizing or reducing atmospheres. Because
they cover a wide temperature range with a single calibration curve, type E thermocouples are preferred for computer applications.
The ratings specified above are the maximum service temperatures at which a thermocouple will yield a satisfactory life. Since the
field of thermocouple applications is extremely diverse, there are cases in which thermocouples may be used above suggested limits,
and on the contrary, those in which satisfactory life will not be obtained at the suggested upper limit.
Made from carefully selected, matched and calibrated conductors in all standard
calibrations. Wires are of uniform high quality because we maintain our own
extensive facility for all production processes from drawing to applying insulation.
Standard constructions can be selected for such special requirements as high
abrasion, moisture and chemical resistance. Stranded wires for flexing applications
and twisted and shielded wires for electrical interference rejection are offered. Metal
coverings are available for increased resistance to mechanical stress and abrasion.
Standard wire coverings include polyvinyl chloride, cotton braid, polyethylene,
Kapton*, nylon, Teflon*, asbestos, fiberglass, copper or stainless steel over braid.
Available in thermocouple and extension types.
*Dupont
Thermocouple connectors
Inserted into the thermocouple circuit at almost any point, rugged quick-coupling
connectors are used wherever disconnections are required, most often on
thermocouples to hasten checking and replacement. Positive locking, will not slip
apart. Connecting parts are of solid thermocouple materials to maintain system
accuracy. Miniature, standard, high temperature and constructions available.
Skinning tool
The patented skinning tool quickly and neatly removes the metal sheath from Mi-
cable to facilitate forming junctions and making connections.
to order skinning tool:
Ordering code:
1. Write out the sheath material ordering symbol from chart I, e.g. Mi-304
2. Indicate outside diameter ordering symbol from chart II, e.g. Mi-3,2-
3. Specify ISA calibration from chart III, e.g. Mi-3,2-J-CL1-304-sgl
4. Specify total quantity and minimum acceptable lengths, e.g. 50 feet Mi-3,2-J-CL1-304-sgl , 3' minimum lengths. Long lengths
are usually shipped coiled.