Purpose
The purpose of this document is to provide a procedure for using Plug and Ring Gauges for
the inspection of NPT threads. This will be achieved by using purchased gauges to inspect
both male & female threads.

Reason
To help ensure non-inspection personnel can inspect NPT connections and either pass or
fail the components.
1. Ring Gauge TWO Step MAX & MIN

L-9711020269 ; 1/2" NPT Ring Gauge Go / No-Go


L-9711020271 ; 1/4" NPT Ring Gauge Go / No-Go

Figure 1: NPT RING GAUGE showing an Acceptable male NPT thread.

The pin thread shown above is below the flush on the max step and above the flush on the
min step. Acceptable limits for an NPT external male thread must lie between the Max or
Min.

Figure 2: NPT RING GAUGE used to inspect male NPT external pin threads
Elmar, Enterprise Drive, Westhill Industrial Estate, Westhill, Aberdeen AB32 6TQ, Scotland, UK.
Tel: +44 1224 740261 Sales Dept: +44 1224 748700 Fax: +44 1224 743138 E-Mail: sales@elmar.co.uk
Elmar Services Inc./Hydrolex 11993 FM 529, Houston, TX 77041. Tel: +1 713 983 9281 Fax: +1 713 983 9282 E-Mail: sales@elmar-houston.com
Elmar Far East Pty Ltd, PO Box 1473, Canning Vale, Perth, WA 6970, Australia. Tel: +61 8 9456 0999 Fax: +61 8 9455 3663 E-Mail: elmar@elmar.com
Elmar Far East Pte Ltd, 4, Tuas Avenue 11, Singapore, 639070, Tel: +65 861 6664 Fax: +65 861 7493 E-Mail: eot@eot.com.sg
Elmar Services Middle East Ltd, B-48 Oilfields Supply Centre, PO Box 1518, Dubai, United Arab Emirates. Tel: +971 4 883 5910 Fax: +971 4 883 7087 E-Mail: sales@elmar.co.ae
Internet: http://www.elmar.co.uk
Technical Bulletin

Title: NPT Ring & Plug Gauge Operation Procedure Bulletin No: 10001585
Page 2 of 2 Rev: A
Prepared By: D. Sutherland Approved By: C. Wade Date: 05/02/08

2. Plug Gauge
L-9711020272 ; 1/2" NPT Plug Gauge Go / No-Go
L-9711020273 ; 1/4" NPT Plug Gauge Go / No-Go

Figure 3 & 4: NPT PLUG GAUGE used to inspect Internal Female box threads.

Figure 5 & 6. NPT PLUG GAUGE showing an acceptable NPT Internal thread.

The plug gauge is shown above the flush on the max step and below the flush on the min
step. Acceptable limits for an NPT Internal Female box thread must lie between the Max or
Min.

Elmar, Enterprise Drive, Westhill Industrial Estate, Westhill, Aberdeen AB32 6TQ, Scotland, UK.
Tel: +44 1224 740261 Sales Dept: +44 1224 748700 Fax: +44 1224 743138 E-Mail: sales@elmar.co.uk
Elmar Services Inc./Hydrolex 11993 FM 529, Houston, TX 77041. Tel: +1 713 983 9281 Fax: +1 713 983 9282 E-Mail: sales@elmar-houston.com
Elmar Far East Pty Ltd, PO Box 1473, Canning Vale, Perth, WA 6970, Australia. Tel: +61 8 9456 0999 Fax: +61 8 9455 3663 E-Mail: elmar@elmar.com
Elmar Far East Pte Ltd, 4, Tuas Avenue 11, Singapore, 639070, Tel: +65 861 6664 Fax: +65 861 7493 E-Mail: eot@eot.com.sg
Elmar Services Middle East Ltd, B-48 Oilfields Supply Centre, PO Box 1518, Dubai, United Arab Emirates. Tel: +971 4 883 5910 Fax: +971 4 883 7087 E-Mail: sales@elmar.co.ae
Internet: http://www.elmar.co.uk

You might also like