You are on page 1of 1

S

W
DAMAGE
BUILDING
N

WEIGHT
STORE
ROOM
DAMAGE
Requirement of 102 ECS
BUILDING
WELDING PLANT+STORE
OFFICE
SECTION ENGINEER
Parking to be planned
CARRIAGE & GAGON
near East Entry
YARD YARD

SHED

FOB connection to
BOOKING OFFICE
concourse to be planned &
WAITING HALL

in proposal by IR
8M WIDE DEPARTURE FOB 3 URINAL
YARD

STORE ROOM
Compressor
STAFF ROOM room
STORE

6000
75500

6 M WIDE ARRIVAL FOB 2


PLATFORM NO 4+5
LIFT 1
108000 LIFT 1
LIFT 1
LIFT 1
LEVEL=92.073M

FOOT OVER BRIDGE LEVEL=99.265M


6 M WIDE ARRIVAL FOB 1
LIFT 1 LIFT 1
LIFT 1
PLATFORM NO 2+3
LIFT 1
LEVEL=92.234M

62000
1500
108M WIDE AIR CONCOURSE

LIFT 1 LIFT 1 LIFT 1 PLATFORM NO 1


LIFT 1 LEVEL=91.858M

10000
GRP Office - G+2
Parcel office & RMS - G+3

12170
9 870.6 sqm
TO BE DEMOLISHED
RPF Office - G
276 sqm PARKING -30 ECS
1400 sqm ELECTRONIC
INTERLOCKING
AS/PHASING

4825
142000

DEPARTURE
CONCOURSE

28000
ARRIVAL ARRIVAL

34000
CONCOURSE CONCOURSE

8M WIDE PROMENADE 8M WIDE PROMENADE

8M WIDE PROMENADE

10.5M WIDE DRIVEWAY 10.5M WIDE DRIVEWAY

NETAJI SCULPTURE NATIONAL FLAG

10.5M
PARKING -105 ECS

SCHEDULE OF REINFORCEMENT 600mm:


ENTRY PARKING -120 ECS ENTRY

WIDE
18M WIDE DRIVEWAY

DRIVEW
AY
TEMPLE
AUTO/
TAXI PARKING

EXIT EXIT
RETAIL SHOPS RETAIL SHOPS
01 13 MO BUS DROP/ 14 27

PICKUP

10.5M WIDE DRIVEWAY 10.5M WIDE DRIVEWAY

RESIDENTIAL

SANSTHAN
RESIDENTIAL

RAILWAY
BABA
SHIRIDI
SHREE
SAI

HEALTH
UNIT
RESI

BAR BAR TOTAL NOS./

RESIDENTIAL
DENT
IAL

BUIL
TIN
RESIDENTIAL SHEE DING
D
RESI
DENT
IAL

RES
IDE
NTI
AL
SHAPE REMARKS
PUSTAKALAYA
GUPTA
MAITHILT
HINDI

RESIDENTIAL
SARAN

TOILET
RESIDENTIAL

BUILDING
DAMAGE
TOILET
RESIDENTIAL

MARK DIA. SPACINGS


RESIDENTIAL

RESIDENTIAL RESIDENTIAL
RESIDENTIAL
RESIDENTIAL

RESI
DENT
IAL

RESIDENTIAL

MARGE
HALL

SHEED
ROO

TIN
MOT M
AR
L

RESIDENTIAL
ENTIA
RESID

SHOP
SHOP LINE
LINE

18M WIDE DRIVEWAY


3
KEY PLAN
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS OTHERWISE MENTIONED.
2. DIMENSIONS ARE NOT TO BE SCALED OFF FROM THE DRAWING.
3. MATERIAL FOR PILE:-
a. CONCRETE GRADE : M30.
b. REINFORCEMENT : Fe 550D CONFORMING TO IS:1786.
4. CLEAR COVER TO ANY REINF. SHALL BE 75mm.
5. THE REINFORCEMENT SHOWN IN TEST PILE IS ONLY FOR
TESTING PURPOSE THE REINFORCEMENT IN WORKING PILE
SHALL BE AS PER DESIGN BASED ON ACTUAL LOADS/MOMENT.
6. THE PILE SHALL BE TESTED AS PER THE PROCEDURE
SPECIFIED IN IS : 2911, PART-4.
7. TEST PILE SHALL BE CAST NEAR BY LOCATION AS SHOWN IN
KEY PLAN. HOWEVER SAID LOCATION NEED TO BE
RECONFIRMED WITH OWNER / CLINT ER/ENGINEER.
8. PILE HEAD TO BE DEVELOPED AS PER TESTER'S REQUIREMENT
9. PILE TEST LOAD CORRESPONDS TO BORE LOG DATA AS
SHOWN. DISCREPANCY IF ANY SHALL BE INFORMED TO
ENGINEER.
A
- ABBREVIATIONS:
SECTION A FGL - FINISHED GROUND LEVEL
1:15 UNO - UNLESS NOTED OTHERWISE
-
TOC - TOP OF CONCRETE
TOR - TOP OF ROAD
TYP - TYPICAL
EGL - EXISTING GROUND LEVEL
22500

1
GENERAL ARRANGEMENT FOR VERTICAL PILE LOAD TEST -
2
NTS -
REFERENCE DRAWINGS:
3

PILE 600mm LOAD DETAILS:


WORKING PILE LOAD = 125 TON
FACTOR OF SAFETY = 2.5
PILE TEST LOAD = 312.5 TON

0 22-JUN-2023 GOOD FOR CONSTRUCTION DNK EMI MMG


REV. DATE DESCRIPTION PRED. CHKD. APPRD.
CLIENT:

INDIAN RAILWAYS

PROJECT:
CUTTACK RAILWAY STATION
REDEVELOPMENT
EPC CONTRACTOR:
URC Construction Pvt. Ltd
No:119, Power House Road,
Erode, Tamil Nadu - 638 001.

PEER REVIEWER:
600
INDIAN INSTITUTE OF TECHNOLOGY MADRAS

DETAILS FOR VERTICAL PILE LOAD TEST (600mm) - DRAWING TITLE: PROJECT STAGE:
1:40 -

INITIAL VERTICAL PILE LOAD TEST

DRAWING NUMBER SCALE SHT. SIZE REV


IR - CTCR - STR - LA - M2 - 1004 A1 0