WHITE LED SLIM EMERGENCY EXIT SIGN SLIM EMERGENCY EXIT SIGN

SLED W1201M / RM SERIES SSE 18M / RM SERIES


PLS Listed PLS Listed
Emergency F Class 1 Emergency F Class 1
Exit Sign Exit Sign

TÜV SÜD PSB TÜV SÜD PSB

Features and Application Features and Application


EXIT SIGN

EXIT SIGN
• LED emergency exit signs with option for Exit or Running • Fluorescent emergency exit signs with option for Exit or
Man signage. Running Man signage.
• Optional recess plate and bracket available. • Optional recess plate and bracket available.
• LED lamps provide high efficiency, durability and low • Easy installation with wall, ceiling or pendant mounting
SLED W1201M energy consumption. options. SSE 18M

SLED W1201RM Recessed SSE 18RM Recessed

Technical Data Dimensions (mm) Technical Data Dimensions (mm)


Mode of Operation Maintained Mode of Operation Maintained
Surface mount 358 48 Surface mount 358 48
Lamp 1W High flux white LED Lamp 8W Fluorescent

Operating Temperature ta 0°C ~ 50°C 100 Operating Temperature ta 0°C ~ 50°C 100

Mains Supply 230V AC 50Hz/60Hz Mains Supply 230V AC 50Hz/60Hz


168 168
Power Consumption 3VA Power Consumption 12VA

Battery High temperature NIMH battery Battery High temperature NICD battery
357 357
Charger Fully automatic Charger Fully automatic
48 48
Charging Monitor Ø 5mm green LED Charging Monitor Ø 5mm green LED

Recharge Period 24 hours With recessed panel


358 48 Recharge Period 24 hours With recessed panel
358 48
Testing Facility Test-switch for independent testing Testing Facility Test-switch for independent testing
100 100
Emergency Duration 3 hours Emergency Duration 2 hours

Low-voltage cut-off to prevent Low-voltage cut-off to prevent


Safety Feature 168 Safety Feature 168
over-discharge of battery over-discharge of battery

Electro-galvanised steel casing Electro-galvanised steel casing


Construction 92 Construction 92
with epoxy powder coating with epoxy powder coating
357 357
Weight (Nett/Gross) 2.0 kg / 2.2 kg 458 Weight (Nett/Gross) 2.4 kg / 2.6 kg 458
SS 563-1:2010; SS 563-2:2010; SS 563-1:2010; SS 563-2:2010;
Compliance Compliance
SS 263-2 (IEC 60598-2-22) /A2:2008 SS 263-2 (IEC 60598-2-22) /A2:2008
Installation Ceiling, wall or pendant mounting Ordering Information Installation Ceiling, wall or pendant mounting Ordering Information
EXIT LEGEND RUNNING MAN LEGEND Cable Entry 3 x 20mm Ø knockout hole EXIT LEGEND RUNNING MAN LEGEND
Cable Entry 3 x 20mm Ø knockout hole
SLED W1201M SLED W1201RM IP Rating IP 20 SSE 18M SSE 18RM
IP Rating IP 20
White text/graphical symbol over White text/graphical symbol over
Legend SLED W1201M-E SLED W1201RM-E
Legend SSE 18M-E SSE 18RM-E
ISO green background ISO green background

Warranty 1 year Warranty 1 year


SLED W1201M-T SLED W1201RM-T SSE 18M-T SSE 18RM-T

Options SLED W1201M-D SLED W1201RM-D Options SSE 18M-D SSE 18RM-D
(Double-sided) (Double-sided) (Double-sided) (Double-sided)
• Recessed panel and bracket • Recessed panel and bracket

6 Specifications subject to changes without prior notice. 7 Specifications subject to changes without prior notice.