You are on page 1of 5

E1 Technical Specifications

E1 Digital Color Doppler Ultrasound System


Technical Specifications

SonoScape Medical Corp

901-05739-A01
E1 Technical Specifications

 μScan image processing technology


1. General Specification  Tissue harmonic imaging
 Invert harmonic imaging
The system adopts the advanced ultrasonic
 Graphic diagnosis icon
Doppler technologies, including the Full Digital
Super-wide Band Beam Former, Digital 4. Standard Configurations
Dynamic Focusing, Variable Aperture and
 μScan function
Dynamic Tracing, Wide Band Dynamic Range,  5-band adjustable frequency in B mode
and Multi-Beam Parallel Processing, etc. Users  Tissue acoustic characteristics index (TSI)
can perform the system with the minimum  THI mode
PHI mode
requirement of training or guidance. This 

 Quad beams
system has been designed to comply with
 2D steer
applicable international standards and  Compound imaging
regulations, ensuring the safety and availability  Biopsy
of this product.  Magnifying the whole image
 B/M/PW/CW auto optimization
This system is based on the computer
 Basic measurement package
technology and Linux operation system, which  Obstetrics measurement package
make the system more flexible and stable.  Gynecology measurement package
System maintenance and function update can be  Cardiology measurement package
Abdomen measurement package
completed by software updating, through which 

 Vascular measurement package


would promote product value and keep the
 Urology measurement package
technological advancement.  Small parts measurement package
 Pediatrics measurement package
2. Physical Specification  TEI index
 IMT measurement
 Size: 378mm×352mm×114mm (W×H×D)
 Standby mode
 Weight: Approx. 6.5kg (at most, including battery)
 Auto full screen magnification
Approx. 6.1kg (at most, without battery)
 Show gallery
 Monitor: 15.6’’ widescreen and high-resolution color
 DICOM3.0
LCD monitor, LED backlight, anti-flickering and
vertically and horizontally rotatable
 Probe port: one (two ports can be equipped by order) 5. Optional Configurations
 Biopsy enhancement (linear)
3. Advanced Technologies  Trapezoidal imaging (convex)
 Panoramic imaging (2D)
 Digital front-end technology
 PW mode
 Multi-beam processing technology
 B+PW simult mode
 Spatial compound imaging

901-05739-A01
E1 Technical Specifications

 LGC 9. Imaging Modes


 PW auto trace
 B mode
 M mode
6. Optional Accessories  THI mode
 ECG  PHI mode
 WiFi  PW mode
 Biopsy bracket  B+PW simult mode
 Color ink-jet printer  Panoramic imaging (2D)
 B/W video printer  Biopsy enhancement (linear)
 Foot switch
 Trolley 10. Display Formats (B Mode Includes
 Backpack (with draw-bar)
Trapezoidal Imaging)
 DVD record
 Remote control  B+B
 Barcode scanner  4B
 Hard disk (1T)  B+M
 SSD hard disk  B + PW
 General battery
 Large capacity battery 11. System Parameters
 Frame rate: up to 60fps (probe dependent)
7. Scan Methods  Grayscale Level: 256
 Electronic curved sector scan
 Electronic linear array scan 12. B Mode
 Gain: 0 - 255 adjustable, 5 steps each
8. Applications  Scan depth: 40cm
 Abdominal  Image zoom, showing magnification (0.8 - 10 times)
 Vascular  TGC: 8 levels slider controls
 Cardiac  Image rotation: 0°, 90°, 180°, 270° selectable
 Gyn/OB  Steer: 0, ±2°, ± 4°, ±6° selectable
 Urology  Harmonic imaging: Off, PHI, THI selectable
 Musculo-skeletal  Image inversion: Left and Right, Up and Down
 Small organ  Compound imaging: Off, 1, 2, 3, 4 adjustable
 Pediatric  Focus: focus position and span adjustable, 17 levels
 Cephalic adjustable. 1 represents single focus, 2 - 17 represents
 Fetal the length control of focus area.
 Trans-rectal  Frequency: 5 bands adjustable
 Trans-vaginal  Chroma: Off and 12 types selectable
 μScan: Off, 1, 2, 3, 4, 5 selectable
901-05739-A01
E1 Technical Specifications

 Line density: Low, Med, High adjustable (non-high  Steer angle: 0, ±8°, ±12°, ±16° adjustable
density)
 Persistence: Off, Low, Med, High, Max selectable 15. Integrated Data Management
 Dynamic range: 20 - 200 selectable
 Grayscale curve: 16 selectable
System
 Sector width: adjustable  Hard disk memory capacity: 500G (lager capacity
 Power: 1 - 100% adjustable, 5% steps each optional)
 RSI: adipose, muscle, fluid tissue and normal tissue  USB ports: three
 Trapezoid imaging: On/Off
 Auto optimization function 16. Image Storage and Playback
 Cine playback: up to 10000 frames in B mode
13. M Mode  Static and dynamic image storage in B mode
 Chroma: 13 types adjustable (including dual-split display and quad-split display)
 Display format: Full, H1/1, V1/2, V1/1, V2/1  The stored images can be viewed directly on PC
 Scan speed: 5 levels adjustable  Clip board function
 Power: 1% - 100% adjustable  Doppler cine playback: Speed is adjustable; Sound can
be played back

14. Spectral Doppler Mode


 Doppler methods: PW (pulsed wave) Doppler
17. DICOM Network Communication
 Mode: PW inactivated mode 1, inactivated mode 2,  Storage: directly transmits images with patient
and activated mode. information to a DICOM file server
 PW simult: On/Off (adjustable in inactivated mode 2  Medical digital images and communication DICOM
or activated mode) 3.0 interface
 Sample volume and position for PW Doppler: 0.5 -
24.0mm adjustable 18. Preset Function
 Spectrum inversion: achievable
 Users can customize the presets based on different
 Angle correction: 0°, 60°, -60° adjustable
probes and examination parts to optimize imaging
 θ angle correction: -88° to 88°, 2° steps each
parameters and adjustment combination.
 Spectral real-time trace: achievable
 Users can arrange the presets.
 Baseline shift: 9 steps selectable
 Users can import or export the presets. (not including
 Frequency range: 3 steps selectable
system-provided examination settings)
 Wall filter: Min, Low, Med, High, Max adjustable
 PRF: 1 - 25KHz (PW) (probe dependent)
Max velocity range: ±0.0576 to ±6.14m/s (PW) (probe 19. Patient Data Management
dependent, sampling angle range: ±60°)
 Name, ID, Gender, Date of Birth, Height, Weight, LMP,
 Scan speed: 5 levels adjustable
EDD and GA can be input
 Doppler Chroma: 13 types selectable
 Patient reports and images are archived by patient
 Display format: FULL, H1/1, V1/2, V1/1, V2/1
examination

901-05739-A01
E1 Technical Specifications

 Reports and images can be previewed 23. Optional Probes


 Preview size can be set to 1×1 or 2×2
 Linear probes
 Previewed file can be selected, deleted, printed or
- L741
DICOM sent, DICOM printed or exported.
 Frequency: 4.0 - 16.0MHz
 Data can be exported to USB drive in BMP, JPG, TIF,
AVI, WMV, PDF, TXT or HTML format.  Array element: 128

- 10I2

20. Annotation and Body Mark  Frequency: 4.0 - 16.0MHz

 Array element: 96
Setting
- L746
 Body mark can be classified by specific examination.
 Frequency: 4.0 - 12.0MHz
Body marks of the examination types such as abdomen,
 Array element: 96
small part, urology, breast, gynecology, obstetrics,
vascular, cardiology and MSK are provided.  Convex probes

 Annotation can be selected and input in the library. - 6V1

Annotations of the examination types such as abdomen,  Frequency: 3.0 - 15.0MHz

urology, small part, breast, gynecology, obstetrics,  Array element: 128


vascular, cardiology and MSK can be preset. - C361
 Frequency: 2.0 - 6.0MHz
21. Safety Standard  Array element: 96

 Comply with IEC 60601-1, Class I BF, - C613


 Comply with IEC 60601-1-2, Group 1, Class B  Frequency: 4.0 - 13.0MHz
 Comply with IEC 60601-2-37  Array element: 128

- EC9-5
22. Environmental Requirements  Frequency: 3.0 - 15.0MHz

 Operation environment  Array element: 128


- Temperature: 0°C to +40°C
- Relative humidity: 30% - 85% (no condensation)
- Atmospheric pressure: 700 - 1060hPa
 Transportation and storage environment
- Temperature: -20°C to +55°C
- Relative humidity: 20% - 90% (no condensation)
- Atmospheric pressure: 700 - 1060hPa
 Power supply
- AC/DC Adaptor:

 Input: 100-240Va.c., 1.5-0.75A,


50-60Hz;
 Output: 19Vd.c., 4.74A
- Main unit: 19Vd.c., 4.74A

901-05739-A01