Since the foundation in 1993, Liaoning· containing the integrated plans covering
Yingkou Tiancheng Fire Protection Equipment existing facilities and the upgrade plans
Co., Ltd has focused on the fire alarm field and meeting the needs of urban fire-fighting
has owned the advantages of production-and- architecture on IT in the future, can greatly
system solutions in the fire-fighting area, by i m p r o v e t h e e ff i c i e n t o p e r a t i o n a n d t h e
adhering to prudent management, independent collaborative efficiency of the whole fire alarm
research and development, individual system.
production, sustainable innovation and Over 30 branch offices of Tiancheng
opening cooperation. Heretofore, Tiancheng located in Beijing, Shanghai, Guangzhou,
has owned the capability to provide the Shenzhen and other cities and regions, forming
integrated fire-fighting solutions for clients, a national selling network and serving the
business users and customers. nationwide users of pre-sales and after-sales
By virtue of the powerful R&D team and services, 24-hour service hotline and effective
the determination of forging ahead with and specific solution to customers' questions.
innovation for years, Tiancheng products have Now, the headquarters of Liaoning·
covered the whole fire alarm area and Yingkou Tiancheng Fire Protection Equipment
peripherals. The full realization of customers locates in Yingkou Area Of China (liaoning) Pilot
one-stop procurement and unified reporting Free Trade Zone, the production area of which
improve the progress of projects and eliminate
has reached to over 18,000㎡. Tiancheng, with
customers' worries.
the outfit of sound and advanced production
The latest launched “Smart Fire equipment, inspection equipment and R&D
Protection” system is designed on the notion of equipment, has ranked in the list of National
smart urban architecture, which is combined High-tech Enterprises, been the owner of
with the new generation of IT such as internet multiple worldwide-authorized certifications and
of things, big data, clouds computing and explored the business at homes and abroad.
mobile internet, and the integrated fire
protection and remote monitoring management
system. “Smart Fire Protection”, both
contents
Technical Specifications
01
Automatic Fire Alarm System
JTW-Z0M-TC5162
Intelligent Rate of Rise & Fixed Temperature Heat Detector
Technical Specifications
02
Automatic Fire Alarm System
JTY-GD-TC901
Independent Photoelectric Smoke Detector
Technical Specifications
03
Automatic Fire Alarm System
TCMK5260
Addressable Loop Isolator
Technical Specifications
Operating current Action current≤170 mA or 270 mA (B and ZX2 short circuit here)
Load capacity Loop 24V, 170mA;Loop 24V, 270mA (B and ZX2 short circuit here)
04
Automatic Fire Alarm System
TCMK5261
Addressable Single Input Module
Technical Specifications
05
Automatic Fire Alarm System
TCMK5263
Addressable Single I/O Module
Technical Specifications
06
Automatic Fire Alarm System
TCMK5268
Addressable Single I/O Module
▪ Two-wire system with non-polarity. There is no extra need of
DC24V, low-pow dissipation
▪ Volt output is volt-free output
▪ Input and output has the feature of cable checking for the shot
or open circuit
▪ The input and output have their own isolating loop which can
filter the interference from the outside
▪ Input terminal can be in field set to normally open cable
Technical Specifications
Operatingvoltage Signalbusvoltage:loop24VDC,Rangeallowed:18.5VDC~26VDC
Operatingcurrent Busstandbycurrent:≤0.3mA,Busactioncurrent:≤0.8mA
Thereisshort,opencircuitinoutputcable,themodulereportsfaultsignaltothe
Outputcablechecking
FACP
Outputcapacity Volt-freeoutput:DC30V/3A
Red(Inputindicator:Flasheswhenpolling,andilluminatesinaction.Output
Indicator
indicator:Illuminatesinaction.)
Electronicallyprogramming,takingoneaddressablepointontheloop.Code
Programmingmethod
range:anyoneaddresswithin1~255
Atmosphericpressure:86KPa〜106KPa,Temperature:-10°C〜+55°C
Operatingenvironment
RelativeHumidity:≤95%,non-condensing
Materialandcolorofenclosure ABS;porcelainwhite
and alarm system
Aspirating smoke detection
Weight about147g(withbase)
Mountingholedistance 60mm
Dimension(L×W×H) 86mm×40mm×86mm(withbase)
07
Automatic Fire Alarm System
J-SAP-TCSB5264
Analogue Addressable Manual Call Point
PRESS HERE
▪ Non-polarized two-wire to the control panel
▪ Reusable
▪ Approvals:LPCB(EN54-7) CE
Technical Specifications
08
Automatic Fire Alarm System
TCSG5267
Addressable Sounder Strobe
Technical Specifications
Weight 200g
Dimension φ101mm×51mm
and alarm system
Aspirating smoke detection
09
Automatic Fire Alarm System
TCSG5266
Addressable Sounder Strobe
Technical Specifications
Weight 200g
10
Automatic Fire Alarm System
JB-TG-TC5000/JB-LT-TC5200
Intelligent Fire Alarm Control Panel
▪ Color menu display
▪ Intelligent bus control, max 255 points per loop and max 64 loops
▪ Comprised of 32 pieces of 64-loop or 128-loop intelligent bus control panel
▪ Comprised of 32 pieces of two-wire or three –wire direct control panel
▪ Glass fuse per loop
▪ Black box, with the optional function of “Set Top Box”
▪ Filter output has been applied to this control panel, including loop bus output, multi-wire output,
Technical Specifications
JB-TG-TC5000 JB-LT-TC5200
JB-TG-TC5000 JB-LT-TC5200
11
Automatic Fire Alarm System
JB-TB-TC5109
Intelligent Fire Alarm Control Panel
Technical Specifications
Output Five output. Fault output. 24V power output. Loop output
and alarm system
Aspirating smoke detection
12
Automatic Fire Alarm System
TCBM5023
Handheld Encoder
Technical Specifications
TCDZ5000
Detector Base
13
Automatic Fire Alarm System
JB-QB-QTC5015
Gas Fire-extinguishing Control Panel
Technical Specifications
Combustible Gas Monitoring System
14
Automatic Fire Alarm System
TC-S5701
Auto/Manual Switch Module
Technical Specifications
Indicator Red
15
Automatic Fire Alarm System
TC-S5712
Emergency Start/Abort Switch
Technical Specifications
Combustible Gas Monitoring System
16
Automatic Fire Alarm System
JB-KR-TC5306
Combustible Gas Alarm Control Panel
Technical Specifications
17
Automatic Fire Alarm System
JT-TC516
Addressable Combustible Gas Detector
▪ Electronically coding
▪ Ceiling-mounted
▪ Electronically addressed
▪ Widely used in homes, hotels, apartments and
other places where combustible gas exists
Gas Fire-Extinguishing System
Technical Specifications
Combustible Gas Monitoring System
Pressure 86kPa-106kPa
18
Automatic Fire Alarm System
JT-TC518
Addressable Combustible Gas Detector
▪ Electronically coding
▪ Wall-mounted
▪ Electronically addressed
▪ Widely used in homes, hotels, apartments and other
places where combustible gas exists
Technical Specifications
Pressure 86kPa-106kPa
19
Automatic Fire Alarm System
JT-TC521
Independent Combustible Gas Detector
▪ Wall-mounted
▪ Non-coding
▪ Widely used in homes, hotels, apartments and other
places where combustible gas exist
Gas Fire-Extinguishing System
Technical Specifications
Combustible Gas Monitoring System
Pressure 86kPa-106kPa
20
Automatic Fire Alarm System
ASD-TC5801/ASD-TC5802
Aspirating Smoke Detector
▪ High precise pipeline sampling and high sensitivity
▪ Operating environment: clean, large places, or places with high-temperature, high-humidity or
strong electromagnetic radiation
▪ Application places: warehouses, offices, production sites, airports, factories, historical buildings,
clean rooms, EDP rooms, communication exchange rooms, shops, cinemas, leisure centers,
churches, libraries, hotels, hospitals, electric and nuclear power plants, storerooms, subways and
etc
▪ Wall-mounted structure
ASD-TC5801 ASD-TC5802
Technical Specifications
Information storage capacity Fire log: 1000 items, fault log: 1000 items and disable log: 1000 items
21
MANUFACTURER
INTEGRAL CONTROL PROJECT FOR
Communicate with other alarm panel
JB-LT-TC5200 Intelligent Fire Alarm Control Panel
Explosion-proof
Smoke Detector Fire display panel PRESS HERE
TC5201B Explosion-proof
TC5101 PRESS HERE
sounder strobe
Intelligent Fire alarm control panel control panel
Telephone extension TCSG5240B
JB-LT-TC5200 TC3235A fire alarm telephone
PRESS HERE
TCSB5214H
PRESS HERE
(intrinsically safe)
TCCRT-5014 CRT Graphic Display Unit TCSB5204
Elevator Heat &Smoke Detector
water pump control Tiancheng
TC5103
panel (passive) fire alarm
PRESS HERE
TCSB5264
PRESS HERE
(intrinsically safe) JTGB-IV-TC601
Smoke Detector
Active
TCSB5205
JTY-GD-TC901 Speaker
CAN line
fan (passive)
start answer
TCXH5215
Independent Ex-IR flame detector
JTGB-IR3-TC803 Electric motor for
Smoke Detector
roller shutter
JTY-GD-TC902S
280°Fire preventing valve
Remote Surveillance and Control System Fire protection equipment power monitoring system
for municipal fire protection IOT
Powered by independent
CAN communica on loop line
220V power supply line
电源 运行 火警 故障 屏蔽 消音
自检 消音 菜单 复位 取消 确认
22
AUTOMATIC FIRE ALARM SYSTEM
CAN communication line CAN communication line Intensive powered and controlled emergency indicator Intensive powered and controlled emergency indicator
TC-ZFJC-E3W-BG01 TC-BLJC-I1LRE2W-BG01
Fire door
monitor interface Magne c door lock Electric fire-proof door closer
TCFH-581K
TC-PKX-4A
Fire extinguish monitor water cannon zone control panel
DC24V
Electromagnetic valve
DN50
Fire extinguish monitor water
cannon zone control panel
TC-PKX-4A Automatic monitor water cannon Automatic monitor water cannon
ZDMS0.6/5S-TC01 ZDMS0.6/10S-TC02 Air sampling Air sampling
hole hole
Large space automatic fire extinguish monitor water cannon system Aspirating smoke detection and alarm system
23
Construction Fire Fighting Project
Beijing Shenzhen
Shanghai
Taiji Information Technology China Merchants Shipyard
North Star Plaza
Industr y Base (Zizhou Island)
Taiyuan
Taiyuan Hangzhou
University of Science and Technology,
Gymnasium Power Plant of Banqiao Group
South Campus
24
Libyan Myanmar Fiji
National Stadium Cantaya International Hotel The city hall of Suva
25