Professional Documents
Culture Documents
NASRULLAHGANJ
SEHORE (M.P)
SEHORE, (M.P)
WATER RESOURCES DEPARTMENT
GOVERNMENT OF MADHYA PRADESH
S.No Components
1 Load List
7 Design of T-Girder
18 Design of Columns
19 Design of Footings
LIVE LOADS
NOTE: Values used for Calculations will be Mx/1.5, My/1.5. For main reinforcement calculation, LSM will be used & FOS of 1.5 will be used for reinf. Calculation. For
calculation of crackwidth, WSM will be used
1 Stresses are in N/mm2
2 Meq is calculated using clause: IS 456 Clause 41.4.2
3 Values obtained are from STAAD PRO.
4 Combinations for Primary forces have been developed on STAAD Pro as per IS 456. The values obtained are used for design.
BOTTOM RAFT
Plate L/C SQX N/mm2 SQY N/mm2 MX kN-m/m MY kN-m/m MXY kN-m/m Meq SY N/mm2 SXY N/mm2 Meq
439 20 1.042 -1.159 609.195 1271.545 161.17 0 0 0 1461.157
590 19 -0.678 2.739 1060.943 1191.053 173.552 0 0 0 1163.032
587 19 0.181 0.957 495.639 439.125 115.12 0 0 0 506.843
MAXIMUM BASE PRESSURE ON RAFT = 0.94 N/mm2
SETTLEMENT SUMMARY
Node L/C X-Trans mm Y-Trans mm Z-Trans mm Absolute mm X-Rotan rad Y-Rotan rad Z-Rotan rad
394 21 0 -1.024 0 1.024 0 0 0
ABUTMENT WALL
Plate L/C SQX N/mm2 SQY N/mm2 MX kN-m/m MY kN-m/m MXY kN-m/m Meq SY N/mm2 SXY N/mm2 Meq
184 15 0.157 0.048 -61.051 -5.72 -6.324 0.356 -0.25 -0.084 64.771
246 15 0 0.127 4.018 54.373 -2.41 -0.178 0.344 0.024 55.791
LOAD LIST: SEEP AMBER (PH2)
Dead Load
1 Masonry Load =0.23*3.0*16 11.04 KN/m
Assumed = 12 KN/m
2 Control room+ER slab thick = 0.3 m
Dead Load =25*0.3 7.5 Kn/m2
Assumed = 7.5 KN/m2
3 Maintenance Bay slab thick = 0.3 m
Dead Load = 7.5 KN/m2
Assumed = 7.5 KN/m2
4 Truss Load = 22.5 KN
(Manufacturer Data)
5 Dead load of EOT RAIL = 3 KN/m
(Manufactuer Data)
6 Pump Floor Slab = 7.5 KN/m2
7 Partition Brick Wall Load = 6 KN/m
PUMP LOAD
Data is Obtrained from Pump Manufacturer
Bare Weight of Pump = 6.907 T
Weight of Motor = 7 T
Weight of Water Column = 3.067 T
Dead Load of Pump = 13.907 T
Live Load of Pump = 16.974 T
3 Total Downward Dead Load = 136.428 KN
4 Number of bolts = 8
5 Total Downward Dead Load per Bolt = 17.054 KN
Live Loads on Pumps
Max Horizontal Thrust (Hor) = 26.772 T
6 Maximum Horizontal Thrust =26.772*9.81 262.633 KN
7 Number of bolts resisting thrust = 8
8 Horizontal thrust per bolt = 32.829 KN
Considering Impact factor as 1.25 = 41.036
Assumed = 42 KN
Weight of Pump Assumed as DL = 14.715 KN
9 Downward Live Load = 30.09 KN
10 Considering Impact Factor as 1.25 = 37.6125 KN
11 Load acting on each Bolt = 4.702 KN
Live Load
2 Live Floor Load on Maintenace bay = 12.5 KN/m2
3 Live Load on Approach Bay = 12.5 KN/m2
4 EOT Load =1.25*dry wt of pump 84.697 KN
5 Assumed = 200 KN
6 Moment on EOT = 100 KNm
7 Horizontal thrust on EOT = 10 KN
7 Live Load on Roof = 1 KN/m2
8 Shutter Load = 7.5 KN/m
9 Inspection Gallery = 3 KN/m2
Distribution Acoss Nodes (Live Load)
Floor Load = 0.75 KN/m2
SUB-STRUCTURE LOAD
WATER UPTO MWL
Hydrostatic Load
1 Unit weight of water = 9.81 Kn/m3
MWL = 304.5 m
FRL = 304.5 m
Bottom raft lev = 293.5 m
Height of tank upto MWL = 11 m
Hydrostatic load upto MWL (Max) = 9.81 * 11 107.91 Kn/m2
Weight of Water = 108 KN/m2
SOIL LOAD
2 Angle of friction = 30 *
Coeff. Of active earth pressure = 0.33
Unit Weight of Saturated soil = 20 KN/m3
Height = 6 m
Saturarated Weight at Raft Level =Ysat*H 120 KN/m2
Active Pressure on Walls =(Ysat-9.81)*H 61.14 KN/m2
Weight of water on bottom raft
3 Height of water upto MWL = 11 m
Load acting on bottom raft = 107.91 KN/m2
ASSUMED = 130 KN/m2
1 EQ Analysis is done on STAAD, Considering structure to be in Zone 3
2 Wind load,Hydrodyanimic calculation is shown on a separate sheet
SUMMARY SHEET FOR LOAD CALCULATIONS
NOTE: Values used for Calculations will be Mx/1.5, My/1.5. For main reinforcement calculation, LSM will be used & FOS of 1.5 will be used for
reinf. Calculation. For calculation of crackwidth, WSM will be used
1 Stresses are in N/mm2
2 Meq is calculated using clause: IS 456 Clause 41.4.2
3 Values obtained are from STAAD PRO.
4 Combinations for Primary forces have been developed on STAAD Pro as per IS 456. The values obtained are used for design.
BOTTOM RAFT (Corner)
Plate L/C SQX N/mm2 SQY N/mm2 MX kN-m/m MY kN-m/m MXY kN-m/m SX N/mm2 SY N/mm2 SXY N/mm2
3216 18 -1.067 0.236 346.045 528.232 13.456 0 0 0 MY
2812 68 -0.096 0.885 469.03 251.711 10.327 0 0 0 MX
3216 21 -1.067 0.236 346.045 528.232 13.456 0 0 0 SQY
MAXIMUM BASE PRESSURE ON RAFT = 0.28 N/mm2
SETTLEMENT SUMMARY
Node L/C X-Trans mm Y-Trans mm Z-Trans mm Absolute mm X-Rotan rad Y-Rotan rad Z-Rotan rad
346 18 0 -2.479 0 2.479 0 0 0
PARTITION WALL
Plate L/C SQX N/mm2 SQY N/mm2 MX kN-m/m MY kN-m/m MXY kN-m/m SX N/mm2 SY N/mm2 SXY N/mm2
1324 139 -0.033 -0.023 -3.174 -10.923 -3.432 -0.409 -2.292 -0.512
770 32 0.041 0.002 4.809 6.629 3.645 -0.03 -1.311 -0.789
1856 33 0.026 0.158 1.606 8.45 1.589 -0.259 -0.355 0.263
Design of RAFT (CORNER)
Max BM of the raft in Top along Shorter direction (Mx +ve) 352.15 kN-m/m
Max BM of the raft in bottom along Shorter direction (Mx -ve) 352.15 kN-m/m
Max BM of the raft in top along Longer direction (My +ve) 312.69 kN-m/m
Max BM of the raft in bottom Longer direction (My -ve) 312.69 kN-m/m
Cl:8.1
of IS Minimum percentage of steel required pt,min = 0.24 %
3370
(part- Min Area of steel required on each face = 0.24/100/2x1000x800 960 mm2/m
2):200
9
Provide 20 mm dia tor steel at a spacing = 150 mm c/c
OK
Cl:8.1
of IS Minimum percentage of steel required = 0.24 %
3370
(part- Min Area of steel required on each face = 0.24/100/2x1000x800 960 mm2/m
2):200
9
Provide 20 mm dia tor steel at a spacing = 100 mm c/c
OK
Hence safe
Check for Base Pressure
= 1.12 N/mm2
Safe
Safe
Design of RAFT (CENTRE)
Max BM of the raft in Top along Shorter direction (Mx +ve) 115.89 kN-m/m
Max BM of the raft in bottom along Shorter direction (Mx -ve) 115.89 kN-m/m
Max BM of the raft in top along Longer direction (My +ve) 94.71 kN-m/m
Max BM of the raft in bottom Longer direction (My -ve) 94.71 kN-m/m
Cl:8.1
of IS Minimum percentage of steel required pt,min = 0.24 %
3370
(part- Min Area of steel required on each face = 0.24/100/2x1000x600 720 mm2/m
2):200
9
Provide 16 mm dia tor steel at a spacing = 250 mm c/c
OK
Cl:8.1
of IS Minimum percentage of steel required = 0.24 %
3370
(part- Min Area of steel required on each face = 0.24/100/2x1000x600 720 mm2/m
2):200
9
Provide 16 mm dia tor steel at a spacing = 250 mm c/c
OK
OK
Cl:8.1
of IS Minimum percentage of steel required pt,min = 0.24 %
3370
(part- Min Area of steel required on each face = 0.24/100/2x1000x600 720 mm2/m
2):200
9
Provide 16 mm dia tor steel at a spacing = 250 mm c/c
OK
Vu = 341.4 KN
Spacing = 245.344446 mm
= 1.12 N/mm2
Safe
Safe
WALL (RL:293.50 TO 296.00)
Grade of concrete M 30
Max. Vertical BM acting on the wall/m Soil face ,My = 116.00 kN-m/m
Max. Horizontal BM acting on the wall/m Soil face ,Mx = 18.01 kN-m/m
Total Area of steel required for Axial tension = (Ast of Axial tension + Ast of Bending)
Ast, due to Axial Tension = T/(2 * 0.87*Fy) Ast, for Axial = 917.24 mm2/m
Unsafe
Vu = 335.20 KN
Spacing = 409.879 mm
Grade of concrete M 30
Max. Vertical BM acting on the wall/m Soil face ,My = 16.47 kN-m/m
Max. Horizontal BM acting on the wall/m Soil face ,Mx = 8.07 kN-m/m
Total Area of steel required for Axial tension = (Ast of Axial tension + Ast of Bending)
Ast, due to Axial Tension = T/(2 * 0.87*Fy) Ast, for Axial = 917.24 mm2/m
OK
WALL (RL:303.00 TO 306.50)
Grade of concrete M 30
Max. Vertical BM acting on the wall/m Soil face ,My = 117.13 kN-m/m
Max. Horizontal BM acting on the wall/m Soil face ,Mx = 27.35 kN-m/m
Total Area of steel required for Axial tension = (Ast of Axial tension + Ast of Bending)
Ast, due to Axial Tension = T/(2 * 0.87*Fy) Ast, for Axial = 917.24 mm2/m
Unsafe
Vu = 296.55 KN
Spacing = 420.184 mm
OK
OK
OK
WALL (RL:293.50 TO 306.50)
Grade of concrete M 30
Max. Vertical BM acting on the wall/m Soil face ,My = 7.28 kN-m/m
Max. Horizontal BM acting on the wall/m Soil face ,Mx = 3.21 kN-m/m
Total Area of steel required for Axial tension = (Ast of Axial tension + Ast of Bending)
Ast, due to Axial Tension = T/(2 * 0.87*Fy) Ast, for Axial = 917.24 mm2/m
OK