PRODUCT DATA FORM

HELLTECH 2K P.U ADHESIVE


POLYURETHANE BASED ADHESIVE

PRODUCT DESCRIPTION It is a polyurethane resin-based, two-component, solvent-free, polyurethane adhesıve. It provides good
adhesion resistance in wide range of applications. Water and solvent free.

RECOMMENDED USE
 Suitable for all parquet and wood flooring,
 Light and heavy -duty wood block flooring
 Laminate floors,
 Mosaic parquet, solid wood parquet, multi-layer parquet
 It can be used also for built-in heated floorings,

ADVANTAGES
 Easily spreadable with a notched trowel,
 It provides highly durable and elastic bonding,
 Fast curing, pedestrian traffic time is short.

PRODUCT CHARACTERISTICS:

Finish Putty
Color Dark beige, green
Density (20˚C) 1,60 ± 0,05 kg/l (A+B)
Mixing Ratio 21:3 (A:B – by weight)
Solids by volume %100 (A+B)
Pot Life (+10°C) 60 minutes
(+30°C) 30 minutes
Light Traffic (20˚C) 24 hours
Fully Cured (20˚C) 7 days
Shore D Hardness 55
Application Method Notched Trowel
Consumption 1,5 kg/m2

APPLICATION PROCEDURES:
Surface Preparation: Application surface should be free of any damages. Surface should have compression
strength of minimum 25 N/mm² and pull-off test result of minimum 1,5 N/mm2. Age of new concrete should
be minimum 28 days depending on the season and the concrete surfaces should have a maximum moisture
content of 5-6%. It should be free of any loose and friable particles, oil and paint leftovers and cement grout.
Wide cracks and defects should be repaired beforehand. Any cement shell and bright screed on the concrete
surface should be cleaned up by equipment such as sandblasting machine, hacking and wiping machine with
diamond drum and impact grinding machine and it should then be roughened and wiped. Remove all dust
from the surface by using industrial type vacuum cleaner.
Concrete surfaces in contact with the soil to be coated should be previously treated with water and water
vapor sealants.

Note: This product is for professional use only. The information in this publication relies on our knowledge and experience that we have gained professionally. However,
the information given here does not relieve the users of their responsibility to test our products for compliance with their specific applications. As application and use
of our products is beyond our control, the recommendations here are not warranted by us. The users are obliged to keep our products under consideration at their
own specific conditions and all responsibility lies with them. Technical data sheets of all our products are regularly updated. The users are liable to get the latest version
of them.
HELLER KİMYA ÜRETİM SAN. Ve TİC. ŞTİ.
Büyükbakkalköy Mah.Yakacık yolu Sok. No:2/1 Maltepe/İstanbul/Türkiye
Tel:+90 2165619388 Fax:+902163116185
Web: www.heller.com.tr E-mail :info@heller.com.tr
PRODUCT DATA FORM

Application Conditions:
- Relative humidity of the air should be 80% maximum and the application (ambient and surface) temperature
should be between 5 and 35 °C.
- In case it is applied outdoors, it should not be rainy 24 hours before and after and during the application.
- Surface temperature should be 3°C above the dew point. (Please contact our company for the Ambient
temperature-Ambient Moisture-Dew Point table.

Mixing Procedure: It is a two-component product and it should, therefore, be prepared at the mix ratio
specified for the quantity to be used, taking into consideration the pot life. For a homogenous mixture, make
sure that the product temperature should not be less than 15°C. Component A should be stirred by itself by
use of a mechanical mixer quickly and then the hardener (Component B) should be added, taking care of the
mix ratio. Components A and B should be stirred for minimum 3 minutes until you have a homogenous
mixture.
Surface Application: When ready for application, the product is applied by notched trowel. On adhered
surfaces, applying movable or fixed pressure is important for performance. With pressure, all surfaces comes
into contact with the adhesive. And it is transferred to the surface uniformly.
Clean Up: When adhesive is wet, can be made with polyurethane or cellulosic thinner. Hardened adhesive
can only be removed mechanically.

PACKING A 24 kg set of HELLTECH 2K P.U ADHESIVE consists of Component A in one pail of net 21 kg and Component
B in one gallon of net 3 kg.

STORAGE Store the product in a cool and dry place. Shelf life of the product is 1 year for Components A and B when
stored properly in the original container unopened.

HEALTH/SAFETY PRECAUTIONS Refer to Material Safety Data Sheet (MSDS) prepared as per the related EU directives before use.

Note: This product is for professional use only. The information in this publication relies on our knowledge and experience that we have gained professionally. However,
the information given here does not relieve the users of their responsibility to test our products for compliance with their specific applications. As application and use
of our products is beyond our control, the recommendations here are not warranted by us. The users are obliged to keep our products under consideration at their
own specific conditions and all responsibility lies with them. Technical data sheets of all our products are regularly updated. The users are liable to get the latest version
of them.
HELLER KİMYA ÜRETİM SAN. Ve TİC. ŞTİ.
Büyükbakkalköy Mah.Yakacık yolu Sok. No:2/1 Maltepe/İstanbul/Türkiye
Tel:+90 2165619388 Fax:+902163116185
Web: www.heller.com.tr E-mail :info@heller.com.tr