I. Application and performance characteristics
TZMQ series pneumatic gate is mainly used to control feeding and discharging, widely used in grain
and oil, feed processing plants.
TZMQ pneumatic gate is divided into type A and type B two categories, all use QGB magnetic
switch cylinder, rapid action, stable and reliable work, and easy operation and control. Type A gate
is suitable for just opening, and close, material flow size does not need to adjust on the occasion, and
the structure is relatively simple and compact. Type B gate is suitable for regulating the opening
size of the occasion, such as for the bottom of the warehouse, it can adjust the opening of the gate
by adjusting the position of the magnetic switch, to achieve the purpose of adjusting the material
flow.
II. Main specifications and technical parameters
See Table 1 below (The theoretical thrust and theoretical pull in the table are calculated at the pressure of
0.63Mpa)
Cylinder Working Magnetic switch Theoretical Theoretical Overall
Parameters diameter pressure Contact capacity thrust pull dimensions
TZMQ20 x20 40 0.4-0.8 5VA AC220V 780 660 920 * 300 * 120
TZMQ25 x25 40 0.4-0.8 5VA AC220V 780 660 1070 * 350 * 120
TZMQ30 *30 40 0.4-0.8 5VA AC220V 780 660 1170 * 400 * 120
TZMQ40 x40 50 0.4-0.8 5VA AC220V 1205 1019 1400 * 500 * 120
TZMQ50 x50 63 0.4-0.8 5VA AC220V 1920 1724 1610 * 600 * 120
TZMQ60 x60 63 0.4-0.8 5VA AC220V 1920 1724 1820 * 700 * 120

III. Main structure and working principle


1、Main structure
The device is mainly composed of an electromagnetic reversing valve, magnetic switch, long
frame, sealing plate, flash-board, wheel, cone bucket, close plate, cylinder fixing plate, air cylinder,
and other parts. The structure diagram is shown in Figure 1.

FIG. 1
2、How it works

1
It is mainly driven by the cylinder ram reciprocating straight motion to realize the gate opening
and closing.
2.1 Pneumatic circuit: Type A gate adopts a two-position five-way solenoid slide valve to control
the opening and closing of the gate and adjusts the speed of gate movement by adjusting the
silencer exhaust throttle valve. The pneumatic circuit is shown in Figure 2

Figure 2. Pneumatic circuit diagram of Type A gate


Type B gate adopts a three-position five-way solenoid slide valve, and the speed of gate movement is
adjusted through a one-way throttle gate. The pneumatic circuit is shown in Figure 3.

Figure 3. Pneumatic circuit diagram of Type B gate


2.2 Electrical control principle: The control circuit can be designed into various forms of the control
circuit according to the needs of the technological process. The reference diagram of the Type A
gate control circuit and Type B gate control circuit are shown in Figures 4 and 5 respectively. (Note:
1SQ and 2SQ are magnetic switches, 1DT and 2DT are solenoid valve coils, 1KA and 2KA are

2
small relays, 1HL and 2HL are indicator lights, and SA is a knob switch).

FIG. 4. Reference diagram of Type A gate control circuit

Figure 5. Reference diagram of Type B gate control circuit

IV. Installation and commissioning


1、Installation
1.1 Equipment installation and pipe connection must be taken sealing measures, no leakage
phenomenon, type B gate installation requirements flat.
1.2 There shall be no air leakage in the air path.
1.3 Installation dimensions are shown in Figure 6 and the parameter table below

3
Model A B C D E F H L
TZMQ20 x 20 20 300 130 130 20 300 120 635
TZMQ25 x 25 20 350 155 155 20 350 120 736
TZMQ30 * 30 20 400 180 180 20 400 120 835
TZMQ40 x 40 20 500 225 225 20 500 120 1035
TZMQ50 x50 20 600 275 275 20 600 120 1235
TZMQ60 x 60 20 700 160 160 20 700 120 1435
Figure 6. Sample of series gate

2、Debugging

4
2.1 Do the no-load test on the feed door first. The movement of the gate should be flexible and free of
crawling and trembling.
2.2 Adjust the one-way throttle valve or silenced exhaust valve, so that the speed of the gate back
and forth is about 0.1m/s.
2.3 Adjust the position of the magnetic switch 1SQ and 2SQ so that the magnetic switch closes
when the A-gate is opened and closed in place. Adjust the position of magnetic switch 2SQ so that
the type B gate closes in place, and adjust the position of magnetic switch 1SQ so that the type B
gate stops in the set position when it opens.

V. Maintenance
1、To check the sealing condition of the gas pipe regularly, as well as the sealing condition of the
connecting parts of the gate itself, the sealing plate should be replaced in time when the
leakage of the gate.
2、The compressed air into the cylinder must be processed by the pneumatic combination of
three large parts. 5-10 sluice gates can be used together with three large parts. Water and
lubricating oil should be released regularly to the three large parts.
3、If it is installed and used outdoors, necessary anti-rust measures and anti-rain measures
should be taken.
4、Gate vulnerable parts including sealing pieces and cylinder seals can be purchased from the
cylinder factory, sealing pieces can be made of 3mm rubber sheet or wool felt.