Key features The Ion Science MiniPID 2 is a
simple plug-and-play sensor, able
PPM MiniPID 2:
Our PPM sensor is designed for
• Humidity-resistant to deliver dynamic and dependable detecting VOCs over the widest
• Anti-contamination design response to thousands of volatile dynamic range on the market
• 10,000 hours lamp life organic compounds (VOCs) in without compromising performance.
• World leading many diverse applications. It is also the only PID sensor
temperature stability with a lamp out diagnostic.
• 10 eV, 10.6 eV and 11.7eV All MiniPID 2 sensors include
lamps available patented Fence Electrode
Technology for industry leading
PPB MiniPID 2:
• Built-in diagnostics
• Wide dynamic range humidity resistant performance The PPB sensor is optimised
• Serviceable electrode and anti-contamination design, to deliver an exceptionally low
stack and lamp protecting the sensor from background which allows for
• Intrinsically safe moisture, dust and aerosols. optimum low-end sensitivity whilst
• Series 4/A1 format maintaining a wide dynamic range.
• Expected life > 5 years Its application-specific integrated
• Manufactured in the UK circuit (ASIC) provides rapid 10 eV MiniPID 2:
& supported worldwide and reliable lamp strike and The 10 eV sensor is used for
exceptional temperature stability. enhanced selectivity of compounds
with lower ionisation energies.
Designed for both diffusive and A key application is measuring
pumped sampling, MiniPID 2 ambient levels of aromatic
delivers an exceptional response compounds, including benzene.
time and clear down.
11.7 eV MiniPID 2:
MiniPID 2 incorporates our next- Only available from Ion Science,
generation long-life lamp which the 11.7 eV lamp extends the range
provides exceptional stability of detectable compounds to
and long-term performance, include chlorocarbons, unsaturated
enabling reliable detection fluorocarbons, formaldehyde,
for 10,000 hours of use. ethylene and methanol.

Unrivalled Gas Detection. ionscience.com


Ion Science is the market leader in developing PID sensors and instrumentation. We strive to deliver
high levels of customer support and enjoy sharing expertise with customers and partners to ensure our
sensors are successfully integrated into their products.

Typical Applications
• Personnel safety
• Industrial hygiene
• Soil contamination & remediation
• Fugitive emissions
• Law enforcement
• Emergency response
• Leak detection
• Fenceline monitoring
• Arson investigation
• Air quality monitoring
• EPA method 21
• HVAC + Building management
systems (BMS)

Unrivalled Gas Detection. ionscience.com


Technical Specifications
PERFORMANCE * ORDER CODES
PPM MiniPID 2 PPB MiniPID 2 10 eV MiniPID 2 11.7 eV MiniPID 2 Intrinsically
Model Supply Voltage Order Code
Safe
Electrode White +
Blue White White
Stack Colour gold spot ✓ 3.0 - 3.2 V MP3SMLLAU2
Minimum 100 ppb 1 ppb 5 ppb 100 ppb
Detection Limit ✓ 3.2 - 3.6 V MP3SMLLBU2
PPM
Range 0->4000 ppm 0->40 ppm 0->100 ppm 0->100 ppm
✓ 3.6 - 10 V MP3SMLLCU2
Response
<3 <8 <8 <8 ✖ 3.6 - 18 V MP3SMLLNU2
Time T90 (s)
>0.65 mV/ppm
Sensitivity >30 mV/ppm >15 mV/ppm >1 mV/ppm ✓ 3.0 - 3.2 V MP3SBLBAU2
@ 100 ppm

✓ 3.2 - 3.6 V MP3SBLBBU2


PPB
POWER AND SIGNAL ✓ 3.6 - 10 V MP3SBLBCU2

Supply Voltage (using 3.6 - 18 V (non intrinsically safe 10 - 18 V) ✖ 3.6 - 18 V MP3SBLBNU2


internal regulator)
✓ 3.0 - 3.2 V MP3SBL0AU2
Supply Voltage (using a 3 - 3.6 V
regulated power supply) ✓ 3.2 - 3.6 V MP3SBL0BU2
10 eV
Current 20 - 32 mA (130 for 100 ms at start up) ✓ 3.6 - 10 V MP3SBL0CU2

Power Consumption 100 mW at 3.3 V ✖ 3.6 - 18 V MP3SBL0NU2

Output Signal 0 - 3.2 V ✓ 3.2 - 3.6 V MP3SB7BBU2


(using internal regulator)

Output Signal (using a 0 to rail voltage - 0.1 V 11.7 eV ✓ 3.6 - 10 V MP3SB7BCU2


regulated power supply)
✖ 3.6 - 18 V MP3SB7BNU2

ENVIRONMENTAL

Temperature Range -40 to 65 °C PATENTS & CERTIFICATION


Relative Humidity 0 - 99% RH, non condensing
Range Patents US 7,046,012 EC 1474681

Certification

LIFETIME & WARRANTY Europe ATEX II 1G Ex ia IIC Ga (-40 °C ≤ Ta ≤ +55 °C) @ 1.1W
(-40 °C ≤ Ta ≤ +65 °C) @ 0.9W
Expected Life >5 years Worldwide IECEx II 1G Ex ia IIC Ga (-40 °C ≤ Ta ≤ +55 °C) @ 1.1W
Lamp Life 10.6 eV 10,000 hours (-40 °C ≤ Ta ≤ +65 °C) @ 0.9W
North America UL913 (8th) EditionClass I, II, III, Division 1 CSA-C22.2 No157-92
Warranty 10.6 eV lamp and MiniPID Body = 12 months
Eurasian № EAЭC RU C-GB.HA65.B.00635/20
11.7 eV lamp = 3 months Customs Union

MiniPID 2 V1.4 this publication is not intended to form the basis of a contract and specifications can change without notice.
* Performance refers to Isobutylene in air at 20 °C and 1 atm.

Distributed by:

ION Science Ltd


The Hive, Butts Lane,
Fowlmere, Cambridgeshire,
SG8 7SL, UK.
T +44 (0) 1763 208503
E sensors@ionscience.com

Unrivalled Gas Detection. ionscience.com