Professional Documents
Culture Documents
VMS recommendations
• Use the following Windows Operating Systems to use HVA:
o Windows 2019 Version 1809 (OS Build 17763.1999)
o Windows 2016 Version 1607 (OS Build 14393.2273)
o Window 10 Version 20H2 (OS Build 19042.1052)
• Reinstall the ADPRO and ENVR driver pack after upgrading to R750
Known Issues
NVR
• Save Panamorph is not working for Immervision/GrandEye cameras
VMS
• Cameras will not render in the Web Client for the recorders older than R6.7.
Intelligent Command
• The camera/recorder timeline feature will work only in 7.5 and higher versions of NVR.
• If the safety compliance dashboard is not configured in the space, upgrading NVR, VMS, and
Intelligent Command to R750 will result in users not receiving occupancy alarms in the safety
compliance dashboard. Intelligent Command will also not display the previously recorded occupancy
data.
• The bounding box feature doesn't support classification, such as Human, vehicle, etc.
1 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
• Intelligent Command supports bounding box for 60 Series, 70 Series, and Xtralis VA cameras, but not
for Axis cameras.
• The exported incident clip does not include a bounding box.
Limitations
• Zoom-in after Tilt/Zoom for Panorama double view in dewarping enabled Axis camera displays a
black half-circle at the top of the screen.
• The alarm sound plays with a nine-second delay if the sound file is in Audio Interchange File Format
(AIFF) format.
• The 180-degree (single panorama) and 360-degree (double panorama) views for Axis dewarp
cameras do not support zoom.
• Post-upgrade settings for Axis dewarpping camera:
o NVR 7.5 upgrade resets the Axis Fisheye dewarping camera to default mode (overview and
wall mount). Reset the camera once again to the desired view and mounting position.
o The VMS upgraded to R750 is required to rediscover the NVR 7.5 with Axis Fisheye
dewarping cameras.
• Post-upgrade settings for Axis encoder camera:
o Delete and re-add AXIS M3007-PV Network Camera after upgrading to NVR 7.5
Troubleshooting
NVR
Q: I am not able to get audio alerts.
A: Enable audio service (open Services under Control Panel > System and Security > Administrative Tools and
check Windows Audio) and check the audio settings on your machine, including speaker volume.
__________________________________________________________________________
Q: The upgrade process displays the Windows temp user profile detected popup for a system with temp user
profiles.
__________________________________________________________________________
2 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
A: Open the camera webpage and check if the resolution pushed from NVR matches the camera resolution. It
could be due to 4MP/5MP mode difference.
__________________________________________________________________________
__________________________________________________________________________
A: Please ensure the browser client is Chrome and is updated and running with version 100.0 or more recent.
__________________________________________________________________________
Q: The VLC player is not displaying the camera name and timestamp in exported WMV clip.
__________________________________________________________________________
__________________________________________________________________________
Q: The Axis camera resolution in NVR is not changed, and streaming stops when you change it in the camera
webpage by changing the dewarping mode.
A: update the resolution in the NVR camera configuration tab to match the changed setting on the camera
webpage
__________________________________________________________________________
Q: The NVR timeline reflects the on-device data only after the recording stop time of the SD card clip. The
recording is not synced with the NVR if the recording is going on on the SD card
__________________________________________________________________________
Q: The Video Analytics feature is missing after you upgrade NVR from R6.0 to R7.0 to R7.5.
__________________________________________________________________________
Q: I could not see configuration screens to add External IO modules from Axis.
A: Only the users with the “External IO - Axis” license can add the External IO modules in NVRs.
__________________________________________________________________________
A: The following modes support PTZ functionality: Single, Single Overview, Quad. Pan functionality is
supported for: Panorama Single and Panorama Double.
__________________________________________________________________________
Q: The analytics-enabled Axis camera added in NVR doesn't have a consistent bounding box.
A: This issue may apply only to Axis Q1798-LE cameras and similar models. This camera has a latency of one
second for the video bounding box.
The configuration settings allow the video and the metadata to play in sync if it comes within 500
milliseconds. In the case of this camera, the metadata is coming with a one-second delay.
4 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
_________________________________________________
Q: Few streams are not rendering while adding multi-imager cameras such as AXIS Q6000-E Mk.
A: In the AXIS Q6000-E Mk camera, the 1st and Quad streams were rendered, while the 2nd,3rd, and 4th
streams did not.
The user is suggested to change the resolution manually to enable rendering. The Axis encoder camera has
1080p and 720p render modes (similar to 5MP/4MP modes on the Honeywell camera). In the above
example: Since for 3 channels 720p mode was set in the camera, NVR was added as 1080p (Default goes to
max), and the camera did not render.
__________________________________________________________________________
5 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
A: Once we change the machine name, we need to make the below changes for the new Maxproweb:
We would need to install a Honeywell Security console certificate on the remote workstation to avoid
streaming errors. This certificate can be obtained from MAXPRO/Pro-Watch NVR server. Please follow the
below steps to install the certificate:
4. Navigate to the certificate issued by Honeywell Security Console as shown below screenshot:
6 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
8. Import this certificate in remote machine Trusted certificate store. Use the attached link on how to
import the certificate to the windows store. (https://support.securly.com/hc/en-
us/articles/360026808753-How-to-manually-install-the-Securly-SSL-certificate-on-Windows)
9. Restart the browser and the application should work.
__________________________________________________________________________
A: Check the camera webpage to see if the algorithm is running. Events will not get reported to the NVR if the
algorithm is not running. Do the following if the algorithm is not running:
__________________________________________________________________________
Q: Auto Discovered Axis cameras are added with the wrong credentials and are not streaming.
A: You can add the individual Axis camera manually, but use only Axis as the Camera Type to discover Axis
cameras from the network. The camera may get added as ONVIF if the Camera Type for the discovery
includes ONVIF.
You can see from the below image that when the discovered camera type includes ONVIF, the camera got
added with ONVIF credentials.
__________________________________________________________________________
7 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
A: The steps to follow when the user wants to upgrade from R670 VMS to R750 without upgrading to R700:
1. Execute Database_VMS_670_700.sql (in ISO tools) using the query express tool.
2. Wait for the execution to complete and close the tool.
3. Install OLED driver from ISO:
ProWatchVMSEnterprise_R750\Prerequisites\OLEDB\msoledbsql_18.3.0.0_x64.msi
4. Upgrade to VMS R750.
__________________________________________________________________________
A: This is a rare issue noticed on a few systems. The pop-up message lists the features you need to enable.
The items on the left are the exact command name displayed on the pop-up (and has 45 in them to indicate
Microsoft .NET Framework 4.5)
Enable the feature from the command line, and start the installation again after restarting the system.
__________________________________________________________________________
8 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
Q: The playback video for the LPR event shows the wrong plate number in the viewer.
A: Configure the ROI in the camera web page and select an image setting other than full frame.
(camera webpage for LPR:- Image -> save full frame -> "full frame 1920X1080" is not recommended)
__________________________________________________________________________
Q: A license popup is displayed with SERVER ERROR while logging into MMshell in one of the VMS server
machines.
9 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
Alternatively, you can end the task for Trinity System Service from the Task Manager, and the service restarts
automatically.
__________________________________________________________________________
Q: The alarms newly introduced in R750 report randomly in the upgraded NVR.
10 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
__________________________________________________________________________
A: The playback event for the camera is reported to NVR only when we restart TSS.
NVR did not receive the Playback event after trying the following troubleshooting:
__________________________________________________________________________
Q: The camera added with the model number is not listing IO if it is not supported. But the same is not
happening if we add the camera with ONVIF.
A: Add the (old or new) Performance series cameras with the model number and not as ONVIF.
VMS
Q: The bounding box is not working for Motion detection if the firmware and algorithm version of the Axis
camera is older than 10.9 and 4.5-1.
11 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
A: upgrade the camera firmware version to 10.9 or the latest and upgrade the algorithm to 4.5-1 or the latest
__________________________________________________________________________
Q: Web Client is not listing devices in some new installations and upgraded machines.
__________________________________________________________________________
A: Reset IIS
__________________________________________________________________________
__________________________________________________________________________
Do not rename from the recorder list on the device tree view as shown.
Instead, open the details view, and save after changing the recorder name.
12 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
__________________________________________________________________________
Q: Crowd detection alerts are not received in the legacy path when the user associates the camera with
crowd detection.
The user performed the following steps to get the crowd detection alarms in the legacy path:
1. Login to VMS.
2. Navigate to Video inputs.
3. Select the camera.
4. Select the Events.
5. Click on associate.
6. Click Crowd Detection and save.
Unable to see any crowd detection alarms in the legacy path after this.
A: The Crowding legacy event maps with analytic crowd detection (since 650 release as per design).
13 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
Select Crowding as shown to receive crowd detection alarms in the legacy path.
__________________________________________________________________________
Add a new Windows user to VMS and apply MaxproCredentialManager (select MaxproCredentialManager
from C:\Program Files (x86)\Honeywell\UVISOM\Utilities and run as administrator)credentials and restart the
system.
Unable to launch MMshell when you log on to the machine with the new credentials.
A: Use the login credentials of the user and restart all services manually, or Enable service log-on through a
local group policy.
1. Sign in with administrator privileges to the computer from which you want to provide Log on as
Service permission to accounts.
2. Go to Administrative Tools, and click Local Security Policy.
3. Expand Local Policy, click User Rights Assignment. In the right pane, right-click Log on as a service
and select Properties.
14 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
The following article provides information about how to enable service log-on as a log-on type.
https://docs.microsoft.com/en-us/system-center/scsm/enable-service-log-on-sm?view=sc-sm-2022
or you can just update the password for one service, access will be added automatically.
__________________________________________________________________________
Q: Observed continuous controller crash and device tree are not updating the camera status.
A: Start the service again after manually setting the Service Logon Account with the Administrator username
and password.
15 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
Intelligent Command
Q: How to change the default database backup path after the installation?
A: The default database backup path is saved in the R700_Maintenance.ps1 file (under
C:\programdata\Honeywell\DatamanagementService), as $BackupPath variable. Update this variable if you
want to change the default database backup path after the installation.
Detailed instructions:
NOTE:
• You don't have to stop/restart any services before and after updating the R700_Maintenance.ps1
file.
• The scheduled job for the backup will run at the scheduled time (12:30 AM) every day and considers
the new database backup path configured by the user.
16 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
__________________________________________________________________________
Q: Unable to change the password for a camera from Intelligent Command when the camera user name is
not unique.
A: The camera displays an internal server error message while trying to change the password if it has two
identical user names on the camera web page. The system ignores the letter case.
The camera user name on the camera web page must be unique (and must take into account the letter case
too.)
__________________________________________________________________________
17 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
Q: Intelligent Command did not load timelines for a few of the NVRs.
• Check if the user can view the video for those NVR cameras in the Intelligent Command.
• If the video is playing, restart the IIS on the NVR box to get a timeline view in the Intelligent
Command.
• Check the NVR connectivity (network, power, user authorization, etc.) if the video is not playing in
Intelligent Command.
18 www.security.honeywell.com
MAXPRO R750 QUICK TIPS AND LEARNING GUIDE
A: This issue arose as the streaming server and Gateway are on the same machine, which has a camera IP and
machine IP. The DNS resolved it in favor of the camera IP for which port 8080 is not open.
Change the network setting and set the NVR intranet for higher preference over the camera network by
unchecking the Automatic metric in Advanced TCP/IP Settings.
Set the NVR intranet for higher preference over the camera network by entering a higher value in the
Interface metric field (enabled after unchecking the Automatic metric checkbox.
For example, set the NVR intranet for the highest preference by entering 5 in the Interface metric field when
the preference level for the camera network is 3.
__________________________________________________________________________
19 www.security.honeywell.com