👉Normal height of contact wire at support point = 5.
60 (pre sag of 100mm)
for regulated OHE 👉Normal height of contact wire at support point = 5.55m (pre sag of 100mm) for regulated OHE 👉Normal height of contact wire at support point = 5.75 (temp. Range 4 o to 65 oc) for unregulated OHE 👉Normal height of contact wire at support point = 5.65m (temp. Range 15 to 65 oc) for unregulated OHE 👉Minimum height of contact wire at loco inspection pit = 5.80m. 👉Minimum height of contact wire at level crossing = 5.50m 👉Height of the height gauge at level crossing = 4.67m. 👉Minimum height of contact wire at over line structure = 4.92m 👉Dia of new contact wire = 12.24m 👉Condemned dia of contact wire on main line = 8.25mm 👉 Condemned dia of contact wire on loop line & yard line = 8.00mm 👉Stagger of contact wire on tangent track = + 200mm 👉Stagger of contact wire at curve track = + 300mm 👉Stagger of catenary wire on tangent track at support = 0 👉At un insulated over lap, the distance between two = 200mm 👉Parallel running contact wire At insulated overlap, the distance between parallel running = 500mm Contact wire 👉The contact wire of turnout OHE is 5cm above that of the main line OHE 👉The minimum desirable length where pantograph = 6 to 9m for High speed 👉Touches both the OHE min 2 to 3m 👉Normal implantation (standard) = 2.50m 👉Minimum implantation = 2.50m 👉Minimum implantation or implantation of platform = 4.75m 👉Normal encumbrance = 1.4m for 72m span On main line, 👉maximum permissible slope of contact = 3mm per m wire In yard line maximum permissible slope of contact wire = 10mm per m 👉Short time Vertical electrical clearance = 270mm 👉Short time Horizontal electric clearance = 220 mm 👉Long time vertical electrical clearance = 320mm 👉Long time horizontal electrical clearance = 320mm 👉Stagger of contact wire at section insulator = 0 or + 100 mm 👉Stagger of contact wire at PTFE neutral section at = 0. support 👉Earthing resistance of traction sub station = 0.50 ohm 👉Earthing resistance of Switching station = 2.00 ohm 👉Earthing resistance at AT supply station/FOB/ROB/ = 10.0 ohm Fencing/Platform structures 👉Cross section area and length of C jumper wire = 50 mm 2, 1.7m 👉Cross section and length of F jumper wire = 50 mm 2, 1.6m 👉Cross section area and length of G jumper wire = 105 mm 2, 3.5m 👉Distance of G jumper from mast onwards overlap side = 5.6m 👉Fixed length of the dropper wire = 105mm 👉The distance of the first dropper from support = 2.25m 👉The distance between runners of section insulator = 4.40mm 👉Standard tension length for regulated OHE = 1600m 👉Normal sag of regulated OHE = 100 mm 👉Maximum span length on tangent track for regulated OHE = 72 m 👉Minimum span length for curved track for regulated OHE = 18 m 👉Maximum tension length for unregulated OHE = 2000m 👉Maximum span length for unregulated OHE = 67.5m 👉ZY value of winch type ATD at half tension length 750m at 35 o C Z = 1250 Y = 2500mm. 👉XY value of 3 pulley ATD at half tension length 750m at 35 o C. X = 1050mm, Y = 2300mm (Old) & X = 1300mm, Y = 2300 (New) 👉Catenary wires/ all other stranded wires like jumpers, anti-creep wire should be replaced if more than 20% strands are broken On main line, the difference in length of adjacent span should not be more than 18 m. 👉Minimum length of dropper in the span = 150mm. 👉At cross type OHE facing turn out, the anchor span should not be more than 54 m. 👉At level crossing, the maximum span should be 58.5m 👉Half tension length on curved line should not be more than 600m. 👉PTFE neutral section should be provided on tangent track at minimum 400 m distance after stop signal and 200 m before stop signal. 👉Leaning of mast at top should not be more than 15 cm. 👉The distance between male and female contact of isolator in open position should be 500mm + 50 mm. 👉Track separation 150 to 720 mm at obligatory structure. 👉Track separation of section insulator If runners are towards T/O point = 1.65m If runners are away from the T/O point = 1.45m......
The multilayer piezo actuators can reach full performance at very low operating voltage. The plate actuator NAC2023 is 15x15 mm and provides a free stroke of 3.1 μm and a blocking force of 9450 N