Features: Unregulated Converters
Features: Unregulated Converters
Notes:
Note3: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Note4: add suffix „/X2“ for alternative pinning (only available for single outputs)
or add suffix „/P/X2“ for continuous short circuit protection and alternative pinning
Ordering Examples:
RP-123.3S/P: 12V Input Voltage, 3.3V Output Voltage, Single Output with continuous short circuit protection
RP-0509S/X2: 5V Input Voltage, ±9V Output Voltage, Single Output with alternative pinning
RP-0505S/P/X2: 5V Input Voltage, 5V Output Voltage, Single Output with continuous short circuit protection and alternative pinning
RP-xx05S RP-xx12S
100 100
90 90
80 80
70 70
Efficiency [%]
Efficiency [%]
60 60
50 50
40 40
30 30
20 20
0505 0512
10 10
1205 1212
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
RP-xx15S RP-xx05D
100 100
90 90
80 80
70 70
Efficiency [%]
Efficiency [%]
60 60
50 50
40 40
30 30
20 20
0515 0505
10 10
1215 1205
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
RP-xx12D RP-xx15D
100 100
90 90
80 80
70 70
Efficiency [%]
Efficiency [%]
60 60
50 50
40 40
30 30
20 20
0512 0515
10 10
1212 1215
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line ±1.2% of 1.0% Vin typ.
3.3Vout 20.0% max.
Load Regulation (5) 10% to 100% load 5Vout 15.0% max.
9, 12, 15, 24Vout and RP-xx1509D 10.0% max.
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
RP-xx05S RP-xx12S
25 25
0505 0512
20 1205 20 1212
15 15
Deviation [%]
Deviation [%]
10 10
5 5
0 0
-5 -5
-10 -10
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
RP-xx15S RP-xx05D
25 25
0515 0505
20 1215 20 1205
15 15
Deviation [%]
Deviation [%]
10 10
5 5
0 0
-5 -5
-10 -10
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
RP-xx12D RP-xx15D
25 25
0512 0515
20 1212 20 1215
15 15
Deviation [%]
Deviation [%]
10 10
5 5
0 0
-5 -5
-10 -10
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
PROTECTIONS
Parameter Type Value
without suffix 1 second
Short Circuit Protection (SCP)
with suffix “/P” continuous
tested for 1 second 5.2kVDC
Isolation Voltage (6) I/P to O/P
rated for 1 minute 2kVAC/60Hz
Isolation Resistance 20GΩ min.
Isolation Capacitance 4pF min. / 10pF max.
basic (IEC/EN60950-1)
Insulation Grade
functional (IEC/EN60601-1)
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
-Vin -Vout
-Vin -Vout
C4
Pinning information
19.65 7.05
Pin # Single Dual /X2
1 +Vin +Vin +Vin
2 -Vin -Vin -Vin
Marking 5 -Vout -Vout no PIn
10.2
ew Bottom View
1 2 5 6 7
1.27
7 1 2 5 6 7 Top View
4 x 2.54 = 10.16
2.54
2.00 6 x 2.54 =15.24
C1 DC C2
DC C3
-Vin -Vout
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm
Packaging Quantity tube 25pcs
Storage Temperature Range -55°C to + 125°C
Storage Humidity non-condensing 95% RH max.