Professional Documents
Culture Documents
RRU 900 SEC 1 RRU 900 SEC 2 RRU 900 SEC 3 AC Main Failure
1
SECTOR 2 3
CPRI RRU 2100 CPRI RRU 2100 CPRI RRU 2100 Grounding RRU 2100
ANTENNA Sec 1
SECTOR 1 SECTOR 2 SECTOR 3 SECTOR 3 6
CPRI_4/UBBP/BBU CPRI_5/UBBP/BBU CPRI_6/UBBP/BBU
to RRU 2100_0/Sec 1 to RRU 2100_0/Sec 2 to RRU 2100_0/Sec 3 2
DC cable power DC cable power DC cable power
BANK BANK 1
ANTENNA Sec 2
RRU 2100 Sec 1 RRU 2100 Sec 2 RRU 2100 Sec 3 4
DC cable power DC cable power DC cable power
1 2
RRU 2100 Sec 1 RRU 2100 Sec 2 RRU 2100 Sec 3 5
RRU HOS 5502 Sec 1 RRU HOS 5502 Sec 2 RRU HOS 5502 Sec 2
1800-2100
RRU HOS 5502 Sec 1
1800-2100
RRU HOS 5502 Sec 2
1800-2100
RRU HOS 5502 Sec 3 ANTENNA Sec 2 7
ANTENNA Sec 3
RRU 5502 1800-2100 RRU 5502 1800-2100 RRU 5502 1800-2100
Grounding HOS Sec 1 Grounding HOS Sec 2 Grounding HOS Sec 3
RRU 5502 1800-2100 RRU 5502 1800-2100 RRU 5502 1800-2100
DC Power Cable
DCDU 16/EPU 02D- 3
DC Power Cable
DCDU 16/EPU 02D- 3
MCB DCDU 16D 3
RRU HOS Sec 1 BANK BANK 1
DC Power Cable DC Power Cable
MCB DCDU 16D 4 5502 (1800 -2100)
3 4
DCDU 16/EPU 02D- 4 DCDU 16/EPU 02D- 4
Power RRU 5502 HOS Power RRU 5502 HOS Power RRU 5502 HOS
OCB to DCDU Sec 1 OCB to DCDU Sec 2 OCB to DCDU Sec 3 RRU HOS Sec 2
Power RRU 5502 HOS
OCB to OCB Sec 1
Power RRU 5502 HOS
OCB to OCB Sec 2
Power RRU 5502 HOS
OCB to OCB Sec 3
5502 (1800 -2100)
Power RRU 5502 HOS Power RRU 5502 HOS Power RRU 5502 HOS
OCB to RRU Sec 1 OCB to RRU Sec 2 OCB to RRU Sec 3 RRU HOS Sec 3 BANK BANK 2
Outdoor
Grounding OCB HOS Grounding OCB HOS Grounding OCB HOS 5502 (1800 -2100) Wireless AC Meter
4 1
to ground Bar Sec 1 to ground Bar Sec 2 to ground Bar Sec 3
Grounding OCB HOS Grounding OCB HOS Grounding OCB HOS
Box (ACMB)
to ground Bar Sec 1 to ground Bar Sec 2 to ground Bar Sec 3
Grounding OCB HOS Grounding OCB HOS Grounding OCB HOS COM 2/CAN to COM
to ground Bar Sec 1 to ground Bar Sec 2 to ground Bar Sec 4 Recti ELTEK
Grounding OCB HOS Grounding OCB HOS Grounding OCB HOS
to ground Bar Sec 1 to ground Bar Sec 2 to ground Bar Sec 3
COM Recti ELTEK to
COM 2/CAN
BANK BANK 2
SCC800-S1 Smart site
RS458 to BBU MON0/1
5 2
monitoring unit
Power Cable SCC-01 Phase L1 Sensor Voltage CT sensor L1 Chanel 1 4G Antenna Cable BBU MON0/1 to RS458
Cable
Power Cable SCC-01 Phase L2 Sensor Voltage CT sensor L2 Chanel 1 4G Antenna Cable COM2/CAN to 1010
Cable SMU Recti Huawei
4 3
Cable Antenna Cable
Outdoor
Grounding AC Meter
Box Grounding Cable SCC CT sensor L2 Chanel 2 Rod antenna Wireless AC Meter
Grounding AC Meter
Box (ACMB)
Box Grounding Cable SCC CT sensor L3 Chanel 2 Rod antenna
COMBINER Sec 1
COMBINER Sec 2
COMBINER Sec 3
Grounding RRU 900
RRU 900 SEC 1 RRU 900 SEC 2 RRU 900 SEC 3 AC Main Failure
2 ring
penanda
sektor 2
(Pwr & CPRI)
3 ring
penanda
sektor 3
(Pwr & CPRI)
Routing jumper di bracing tower sebelah dalam dan posisi di samping bracing jangan di atas bracing per 1 meter (
Routing jumper di
sebelah dalam samping
bracing tower di ikat
kabel ties hitam dengan
kuat dan rapi
Routing jumper di
sebelah dalam samping
bracing tower di ikat
kabel ties hitam dengan
kuat dan rapi
ping
t
gan
per di
am samping
er di ikat
tam dengan
pi
Grounding RRU 1800
RRU 1800 SEC 1 RRU 1800 SEC 2 RRU 1800 SEC 3 Door Open
ANTENNA OMNI 1
Sharing SEC 1 &2
Grounding RRU 1800
RRU 1800 SEC 1 RRU 1800 SEC 2 RRU 1800 SEC 3 Sharing SEC 1 &2
Smoke Sensor
RRU 1800 Sharing RRU 1800 Sharing RRU 1800 Sharing Grounding RRU 1800 Water Sensor
ANTENNA OMNI 1
SEC 1 & 2 SEC 1 & 3 SEC 2 & 3 Sharing SEC 1 &2
RRU 1800 Sharing RRU 1800 Sharing RRU 1800 Sharing Grounding RRU 1800 High Temperature
SEC 1 & 2 SEC 1 & 3 SEC 2 & 3 Sharing SEC 1 &2
RRU 1800 Sharing RRU 1800 Sharing RRU 1800 Sharing Grounding RRU 1800 Batt High Temperatur
ANTENNA OMNI 2
SEC 1 & 2 SEC 1 & 3 SEC 2 & 3 Sharing SEC 1 &2
RRU 1800 Sharing RRU 1800 Sharing RRU 1800 Sharing Grounding RRU 1800 Phase Failure
SEC 1 & 2 SEC 1 & 3 SEC 2 & 3 Sharing SEC 1 &2
CPRI_1 RRU 1800_0/ CPRI_1 RRU 1800_0/ CPRI_1 RRU 1800_0/ Grounding RRU 1800 Arrester Fail (AC SPD)
ANTENNA OMNI 2
Sharing Sec 1 & 2 Sharing Sec 1 & 2 Sharing Sec 1 & 2 Sharing SEC 1 &2
CPRI_1 RRU 1800_0/ CPRI_1 RRU 1800_0/ CPRI_1 RRU 1800_0/ Grounding RRU 1800 Door Open
Sharing Sec 1 & 2 Sharing Sec 1 & 2 Sharing Sec 1 & 2 Sharing SEC 1 &2
CPRI_1 CPRI_2 CPRI_3 Grounding RRU 1800 Smoke Sensor
ANTENNA OMNI 1
RRU 1800_0/Sec 1 RRU 1800_0/Sec 2 RRU 1800_0/Sec 3 Sharing SEC 1 &2
CPRI_1 CPRI_2 CPRI_3 Grounding RRU 1800 Water Sensor
RRU 1800_0/Sec 1 RRU 1800_0/Sec 2 RRU 1800_0/Sec 3 Sharing SEC 1 &2
CPRI_RRU 1800 CPRI_RRU 1800 CPRI_RRU 1800 Grounding RRU 1800 High Temperature
ANTENNA OMNI 2
Sharing SEC 1 & 2 Sharing SEC 1 & 2 Sharing SEC 1 & 2 Sharing SEC 1 &2
CPRI_RRU 1800 CPRI_RRU 1800 CPRI_RRU 1800 Grounding RRU 1800 Batt High Temperatur
Sharing SEC 1 & 2 Sharing SEC 1 & 2 Sharing SEC 1 & 2 Sharing SEC 1 &2
CPRI_RRU 1800 CPRI_RRU 1800 CPRI_RRU 1800 Power Cable Groundingkit Power
Sharing SEC 1 & 2 Sharing SEC 1 & 2 Sharing SEC 1 & 2 UPEU / BBU RRU 1800 Sector 1/2 Grounding BBU Phase Failure
DC cable power DC cable power DC cable power Power Cable Groundingkit Power
RRU 1800 Sec 1 RRU 1800 Sec 1 RRU 1800 Sec 1 UPEU / BBU RRU 1800 Sector 1/2 Grounding BBU Arrester Fail (AC SPD)
DC cable power DC cable power DC cable power Power Cable Groundingkit Power
RRU 1800 Sec 1 RRU 1800 Sec 1 RRU 1800 Sec 1 EMUB RRU 1800 Sector 1/2 Grounding Cable RTN PHASE R To ACPDB
DC cable power DC cable power DC cable power Power Cable Groundingkit Power
RRU 1800 Sec 1 RRU 1800 Sec 2 RRU 1800 Sec 3 EMUB RRU 1800 Sector 1 Grounding Cable RTN PHASE S To ACPDB
DC power RRU 1800 DC power RRU 1800 DC power RRU 1800 SMU 1010 to
Sharing 1&2 Sharing 1&2 Sharing 1&2 MON1 UPEU UIM03F1 to EXT ALM 0 Grounding Cable DCDU PHASE T To ACPDB
DC power RRU 1800 DC power RRU 1800 DC power RRU 1800 MON1 UPEU to
Sharing 1&2 Sharing 1&2 Sharing 1&2 SMU 1010 EXT ALM 0 to UIM03F1 Grounding Cable DCDU NETRAL (N) To ACPDB
Groundingkit
Main Power RTN Main Power RTN Main Power RTN Main Power RTN
RRU1800 Sharing 2&3 Grounding Cable RTN PHASE T To ACPDB
STBY Power RTN STBY Power RTN STBY Power RTN STBY Power RTN Grounding Cable BBU Grounding Cable RTN NETRAL (N) To ACPDB
DCDU-12B RFC MCB DCDU-12BB RFC DCDU-12B RFC MCB DCDU-12BB RFC Grounding Cable BBU Grounding Cable DCDU NETRAL (N) To ACPDB
BBU/UMPT FE/GE TO TRM FE/GE TO BBU/UMPT FE/GE TO TRM FE/GE TO Groundingkit Power RRU
TRM FE/GE BBU/UMPT FE/GE TRM FE/GE BBU/UMPT FE/GE 5502 1800-2100 sec 3 Grounding Cable DCDU Batteray Stolen
48 DCDU2A/RFC/BTS 48 DCDU2A/RFC/BTS 48 DCDU2A/RFC/BTS 48 DCDU2A/RFC/BTS to BBU/UMPT FE/GE TO TRM FE/GE TO DCDU-12B RFC
to MCB 80A Rectifier to MCB 80A Rectifier to MCB 80A Rectifier MCB 80A Rectifier TRM FE/GE BBU/UMPT FE/GE
48 DCDU2A/RFC/BTS 48 DCDU2A/RFC/BTS 48 DCDU2A/RFC/BTS 48 DCDU2A/RFC/BTS to BBU/UMPT FE/GE TO TRM FE/GE TO MCB DCDU-12BB RFC
to MCB 80A Rectifier to MCB 80A Rectifier to MCB 80A Rectifier MCB 80A Rectifier TRM FE/GE BBU/UMPT FE/GE