FLAME RETARDANT CONTROL CABLES (COLLECTIVELY SCREENED) TYPE U-HFA m:-
STRANDED IEC 60228 CLASS 2 COPPER CONDUCTOR. CABLES TO BE COLLECTIVELY
SCREENED WITH BRAIDED COPPER. THE INSULATION SHOULD BE XLPE AND SHEATHING SHOULD BE FLAME RETARDANT HALOGEN FREE THERMOPLASTIC COMPOUND. CABLES SHOULD BE DESIGNED TO MEET IEC60092-353 CRITERIA AND TESTED AS PER IEC60332-1 AND 3 CATEGORY A/F OR A/F/R.
FLAME RETARDANT POWER CABLES (TYPE U-HF m):
RETARDANT MARINE CABLE WITH ANNEALED STRANDED IEC 60228
THE INSULATION SHOULD BE XLPE AND SHEATHING SHOULD BE FLAME RETARDANT HALOGEN FREE THERMOPLASTIC COMPOUND (SHF1). CABLES SHOULD BE DESIGNED TO MEET IEC60092-353 CRITERIA AND TESTED AS PER IEC60332-1 AND 3 CATEGORY A/F OR A/F/R.
1 AS FITTED INFORMATION INCORPORATED 22-12-13 HEM PRANIL SAMEER IFA
GRANDWELD 0 FOR CLASS APPROVAL 31-03-13 HEM PRANIL SAMEER IFA
GRANDWELD REV. DESCRIPTIONS DATE DRN. CHKD. APPD. ISSUE
NAME OF VESSEL : SHEET CONTENTS :
42M. ALUM. CREW BOAT BLOCK DIAGRAM OF MAIN ENGINE TEL: +971 4 3243702 (GLOBAL PHOENIX) DRAWN BY : HEM DESIGN : GRANDWELD DWG. NO. : REVISION FAX: +971 4 3243146 CHECKED BY : PRANIL CLASS : LRS H109-792-501 1 Grandweld Shipyards P.O.BOX 24755 DUBAI U.A.E.
APPROVED BY : SAMEER : NTS www.grandweld.com
CLIENT : JOB NO. : J-557V SCALE GLOBAL MARINE COMPANY LLC. DATE : 31-03-2013 HULL NO. : H109/12 SHEET : 1 OF 1 FORMAT : A3