You are on page 1of 5

2950SCHEDESS_2950SCHEDAES (E101110X_ENG) 20/10/2009

ECC CONTROL BOARD PROGRAMMING


INSTRUCTIONS (2950SCHEDAES)

FOR IMESA TUMBLE DRYERS MODEL “ES”

IMESA S.p.A.
Via degli Olmi 22
31040 Cessalto (TV), Italia
tel. +39.0421.468011
fax +39.0421.468000
www.imesa.it
2950SCHEDESS_2950SCHEDAES (E101110X_ENG) 20/10/2009

INDICE: This manual must always be available for


consultancy. In case of lost or damage,
1. INTRODUCTION ............................................. 2 ask for a copy to the manufacturer.
2. INSTALLER’S INFORMATION AND Manufacturer is not responsible for
SAFETY RULES ............................................. 2 consequences due to a not correct board
3. SAFETY RULES.............................................. 2 configuration or due to a not complete or
4. MANUFACTURE LIABILITY ..................... 2 missing reading of this manual.
5. PROGRAM ......................................................... 3 Manufacturer reserves itself the right to
6. LANGUAGE CHANGE................................. 3 modify the specification here written.
7. PROGRAM MODIFICATION ..................... 3 Picture may differ from reality in some
8. BOARD RESET ............................................... 3 details. Diagram and Technical data can
9. “COIN OP” PROGRAM ............................... 3 be modified without any previous notice.
10. PROGRAM: RESIDUAL HUMIDITY
CONTROL (ONLY ICD VERSION). ..... 4
11. PROGRAM: “INSTALLATION” 3. SAFETY RULES
MENU. .................................................................. 4 Do not respect the following rules may
cause damages to people, object or
animals.
1. INTRODUCTION
This instructions explain the ECC Installation and maintenance of the here
electronic board installation (code: described board must be done only by
2950SCHEDESS – marked by EN0304) authorised personnel, who knows the
on IMESA dryers model ES. product and respecting the European
rules in matter of installation and
This document contains all the main reparation of industrial machines.
program function as well as the password
to access to the configuration menu and The here described dryers are addressed
indication to program the self service only to a professional use: any other use
prices. is forbidden if not previously authorised in
written by the manufacturer.

2. INSTALLER’S INFORMATION AND Supplementary external connection to the


SAFETY RULES machine, if not duly preformed, release
This manual is written in compliance with the manufacturer from any responsibility.
the European Community laws in force,
and it refer about: The above advices do not cover all
possible risks. User must proceed
 Information about machine with maximum care respecting the
technical features; rules.
 Instruction for the correct 4. MANUFACTURE LIABILITY
machine installation and working; Instruction of this document do no
 Instruction for ordinary replace, but only integrated, the duties
maintenance; coming from the safety and accident
 For the electrical diagram, please prevention rules in force.
refer to the copy stored inside the With reference to what is written in this
machine. document, the manufacturer is not
responsible for:
Information are addressed to installer and  use of the machine not in
service man, who must be sure to well compliance with the safety and
understand the instruction here given accident prevention rules in
before to work or service the machine. force;
2950SCHEDESS_2950SCHEDAES (E101110X_ENG) 20/10/2009

 Not correct board installation; - ESPANOL / SPANISH


 Missing of a ordinary and - DEUTSCH / GERMAN
programmed maintenance; To change the languange, display the
 Missing or not respect of the right one and press “ENTER”.
instruction written in the manual; To exit the menu press “STOP” until the
 Tension or supply defects; display shows “SELECT PROGRAM” (in
 Not authorized modification to the the chosen language)
machine.
 Use of the machine by not
authorized people; 7. PROGRAM MODIFICATION
The programs can be modified or new
program can be created.
5. PROGRAM The maximum number of programs kept
Put the new board inside its room after in memory are 10.
that the behind connectors was taken off. Press the password “777” to enter in the
Connect the new connectors in the second level menu “PROGRAMS”, the
previous position, keypad and display following parameter can be visualized
included. and modified:

The board can be supplied also “on the - NAME


table” using a 220V~ (phase/neutral) and - CYCLE LENGTH
supplying the two poles connector called - ROTATION TIME
JP12. Obviously, connect in the same - REVERSING PAUSE
position the keypad and the display. - CYCLE TEMPERATURE
- COOLING LENGTH
Supply the board and press the keys “+” - TEMP. COOLING END CYCLE
and “-“ at the same time. - BUZZER
“PASSWORD” should be displayed. If
different messages should be displayed, Refer to dryer user manual for program
then check if the key flat is correctly creation / modification.
connected. Anyway, entering in each paramether
pressing “ENTER” it can be modified.
Press “ENTER” and digit the password To exit from this menu, press “STOP”
“777” to enter in the user menu where, until the display shows “SELECTR
using the keys “+” and “-“ it is possible to PROGRAM”.
enter in the following parameters:

LINGUA / LANGUAGE 8. BOARD RESET


PROGRAMMI/PROGRAMS To set the factory orginal value press at
INFORMAZIONI/INFORMATION the same time the keys “+” and “-“. The
PASSWORD display is showing “PASSWORD”.
Press “ENTER” and digit “712”
Wait for some seconds until the message
6. LANGUAGE CHANGE “OK” will be displayed. Switch off the
The available languages are: board and than switch it on again.
- ITALIANO / ITALIAN
- HRVATSKI / CROATO
- FRANCAIS / FRENCH 9. “COIN OP” PROGRAM
- ENGLISH The control board can be configured to
- NORSK / NORWEGIAN work in coin op version dryer.
- PORTOGUES / PORTUGUESE Digit the password “6776” and later use

3
2950SCHEDESS_2950SCHEDAES (E101110X_ENG) 20/10/2009

the keys “+” and “-“ to find the parameter


“COIN BOX”. Tot. price = 3x1.00€ = Program cost
3.00€ (Password 777)
Enter in the menu pressing “ENTER” and
1.00 €
than press “+” to display the message
“YES”, confirm with “ENTER” and then
press “STOP” to exit this menu. Minimum price
(Password 767)
Digit the password “767” to enter in the 3
menu “INSTALLAZIONE” and modify the
following parameters:
CURRENCY(€, $, token…)
Base time
CURRENCY DECIMAL (1,0; 1,00; 1,000;
(Password
1,0000 ...) 777)
MINIMUM PRICE (the minimum cost of Total time = 3x5’ = 5’
the program). 15’
TOKEN1 (set1 if token are used, 0.10 if
coin are used.
Exit the menu pressing “STOP” so many Each time the customer will insert € 1.00,
time as necessary. he will benefit of 5 minutes time.

Digit the password “777”, select 10. PROGRAM: RESIDUAL HUMIDITY


“PROGRAMS” and press “ENTER”. CONTROL (ONLY ICD VERSION).
In the “COIN OP” version the first trhee The control board can be configured to
programs are named as follow: work also on residual humidy control
HIGH (program 0) dryers (mod. ICD). If this version is
MEDIUM (program 1) activated on standard dryer (mod. ES) ,
LOW (program 2) the board will not work correctly.
Using the keys “+” and “-“ select the To activate this funcion digit the password
program that needs to be modified and “6776” and look for the parameter
look for the parameter “PROGRAM “HUMIDITY”, than change the value from
COST” AND “BASE TIME”. NO to YES using the keys “+” and “-“ .
Exit this menu pressing the key STOP
PROGRAM COST: set the price of each until the display is showing “SELECT
time unit that the customer can buy. PROGRAM”

BASE TIME: set the length of each time


unit. 11. PROGRAM: “INSTALLATION”
MENU.
EXAMPLE: Using the password “767” it is possible to
If we want to create a program which cost enter in the program second level menu.
€ 3.00 and is 15’ long, the parameters Parameter available in this menu are:
need to be set as follow:
 TEMPERATURE MEASURE
UNIT: using the keys “+” and “-“
it is possible to choose the
temperature measure unit:
Celsius (°C) or Fahrenheit (°F).

4
2950SCHEDESS_2950SCHEDAES (E101110X_ENG) 20/10/2009

 NO WRINKLE: To select this


funtion use the keys “+” and “-“.
 CYCLE MAX TIME Maximum
length of the cycle (minutes)
 ROTATION MAX TIME: max time
of rotation in one sense
(seconds)
 PAUSE MAX TIME: max pause
time for each cycle (seconds).
 MAX TEMPERATURE: Max
temperature for each cycle (in °C
o °F).
 MAX COOLING TIME: Max
cooling time at the end of the
drying cycle (minutes).
 MAX TEMPERATURE AT END
COOLING CYCLE: Temperature
to be reached at the end of the
cooling cycle (minutes).
 HYSTERESIS: temperature gap
which confirm the activation and
not activation of the heating
system when the wished
temperature is reached
(expressed in °C or °F).

ONLY FOR MACHINE WITH RESIDUAL


HUMIDITY CONTROL MOD. “ICD”:

 MAX RESIDUAL HUMIDITY AT


THE END OF THE CYCLE:
settino of the max limit of residual
humidity at the end of the cycle
(%)

ONLY FOR COIN OP DRYERS (see


COIN-OP program paragraph):
 CURRENCY: allows to set the
currency shown at display.
 MINIMUM PRICE: set the
minimum number of time unit that
a customer needs to by to run the
program.
 TOKEN1: set the value of each
token which pass through the
coin mechanism.
 TOKEN2: like for TOKEN1, but
only when the dryer is equipped
with two coin boxes or two
payment systems.