GX TOUCH 50
CERBO GX SMART MPPT ORION-Tr SMART-1 ORION-Tr SMART-2
GX TOUCH 50
The SmartBatteryProtect must be programmed SOLAR ARRAY MAIN FUSES Orion Inputs
for Li-Ion mode-C and 12 Volt either through AC Input Inverting AC Loads as close to starter battery
victron energy victron energy victron energy
FROM LYNX SMART BMS VE.Direct from MPPT programming on the device itself or with a BLUE POWER BLUE POWER BLUE POWER
VE.Direct
T
POSITIVE T
VE.Can
VE.Bus
A A
B
BUSBAR B
RE
RE
! IP43 IP43
SE
SE
HDMI ENGINE Ignition i IP43 i i
T
340W
DC Power
Battery 12/24V 50A Input I 8-17V Input I 8-17V
12.8V 13.2A -255W MCB
SMART BATTERY PROTECT 220 Output I 10-15V L L Output I 10-15V
Absorbtion
PV 100Vmax 50A Power I 360W (30A)
O
A
O
A Power I 360W (30A)
victron energy D D
Float
SBP 220 Out
Bulk
on/off on/off
CERBO VE.Can
SBP 220 IN + The GX Touch 50 and the CERBO GX BATTERY PV IN GND OUT IN GND OUT
VE-direct
NEGATIVE
BUSBAR There are several configuration options
possible. Read the Orion-Tr manual carefully
and choose the one fitting your installation.
Spare -
SBP220 GND
FROM MPPT TO CERBO
CERBO Power -
CERBO Power +
Spare - ORION's H CONNECTIONS ORION-1 H CON. ORION-2 H CON.
Load 4 - ON
250A
ALTERNATOR STARTER-MOTOR
EC
Load 5 -
OT R
Charger 12V-5A
N P
OF F I G N I T I O
FROM ALTERNATOR D+
D3
MultiPlus-II CG
OFF
Negative Busbar
Spare
G TO
175A
HIN
Negative Busbar FUSE
ve
mo
I TC
Re
SW
xx AMP.
INTERNAL R
E
FO
BE
victron energy
I NE
BAT_MIN
G
30 15 S T OP E N
ALTERNATOR
BLUE POWER
BAT_PLUS
50
D5
B- D+ B+
OFF
MPPT & Orion's Single Circuit POSITIVE 30 FROM STARTER+(30)
Starter Battery
150A
ENGINE SYSTEM
Dual Output BUSBAR IP-65 | waterproof
MultiPlus-II Batt-
victron energy
D2
MS-1 Common ON
MEGA
Load 1 + MOTOR
400A
MultiPlus-II Batt +
xxxA
31 AGM 12-125
MultiPlus-II Batt- ALTERNATOR AGM Super Cycle Battery li-ion
recondition
12V-150A
D1
high [14.7V]
MEGA
xxxA Load 2 + normal [14.4V]
CERBO Power +
ENGINE Ignition
CERBO Power -
CERBO VE.Can
ORION's H Conn.
mode
SBP H-contact
Distributor
MultiPlus-II Batt-
BMS
MEGA
xxxA Load 4 + victron energy
IP22
BMS
B L U E P O W E R
MultiPlus-II Batt-
REM
L
status
H
lynx smart BMS
NC COM NO
RELAY
victron energy
BMS MEGA
Load 5 + MultiPlus-II / 3KW/12V/120A 2x120V-60Hz AC
BLUE POWER
xxxA
ON/OFF
ATD
INVERTER/CHARGER
ATC
500
+ -
AUX
VE.Can VE.Can
FUSES
POSITIVE
CERBO
1A PRE-ALARM PIEZO BUZZER BUSBAR
Distributor
0.5A
Pre-Alarm
60 AMPERE
0.2A MAIN INCOMING
285060F
A
B
T
12 Volt 30mA
D
A
L
AC BREAKERS
S ET MPPT + TOWARDS
RE
ISOLATION TRANSFORMER
MultiPlus-II
2 x Lithium 12.8V-200Ah OR GALVANIC ISOLATOR
D4
victron energy
Smart LiFePO4
60 AMPERE
INCLUDING NECESSARY
285060F
A
B
T
BREAKERS. 120V/60Hz AC
D
A
L
M8 CIRCULAR CONNECTOR ORION 1 +
D3
T
SE
RE
Spare
BTV CABLE
60 AMPERE
285060F
A
B
T
0
victron energy
BAT_MIN
BLUE POWER
D
BLUE POWER
A
L
Shore Gen
BAT_PLUS
www.victronenergy.com
D5
S
1
RE
MultiPlus-II Easy Lock
VOLT
AMP
VA
AC transfer switch: 120/240V | AC transfer capacity: 50A | Inverter 120V
250A
D2
BLUE POWER
charger inverter L2
MultiPlus-II Batt +
250A
mains on inverter on L1
MultiPlus-II Batt +
bulk
absorbtion
overload
low battery
L2
L1
L2
L1
SHORE POWER
float temperature CONNECTION
D1
Before charging read the instructions. For indoor use only. Disconnect
the supply before making or breaking the connections to the battery.
WARNING: Explosive gases, prevent flames and sparks, provide
M8 CIRCULAR CONNECTORS adequate ventilation during charging. Charge lead-acid or Li-Ion
batteries only.
victron energy N
AC-OUT-2
L2 PE L1
Current
Sense
+
-
+
K1
Ext.GND
inside MultiPlus-II
Push
button A +
Aux V-Sense
COM
NO
NC
TRICKLE
CHARGE
12.8V-200Ah GND
3
NO
2
NC COM
AUX RLY
1
In systems with Victron Smart Lithium Batteries, it's important that all
Lynx Smart BMS charging devices as well as loads are controlled by the BMS.
Here is how that is taken care of in this system: MultiPlus-II AC IN
Enlarged connections 1 - MultiPlus-II Inverter/charger: digitally via the GX Device, DVCC feature.
2 - Solar charger: digitally via the GX Device, DVCC feature. MultiPlus-II AC OUT-2
M8 CIRCULAR CONNECTOR
3 - Orion Tr: ATC wire control, using the switched positive wire from the
engine ignition towards the ATC contacts on the BMS and from there MultiPlus-II AC OUT-1
towards each Orion Tr.
VE.Can VE.Can BMS BMS 4 - DC Loads: via SmartBattery Protect 220. Blue Smart charger
AUX ATC ATD RELAY REM 5 - AC Loads: controlled together with the MultiPlus-II Inverter/Charger. Conn-B VE.Bus
+ - NC COM NO H L
Busbar of the DC system. Size of this cable AC power source at its input. This will prevent heavy loads such as 240VAC
ENGINE Ignition must be identical to connected DC negative. water heaters or air-conditioning units from draining the batteries.
BTV CABLE
IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION !
BTV CABLE Recommended AC Out-1 cable/breaker size MultiPlus-II Recommended AC Out-2 cable/breaker size MultiPlus-II Recommended DC cable/fuse size MultiPlus-II Recommended AC IN WARNING
name :hager :hager name :hager :hager name :hager :hager name :hager :hager name :hager :hager name :hager :hager
3KW to the output load of L1 only. present on AC IN. During battery operation length: 4 x 70SQmm. When used in closed AC IN must be protected by a circuit HAZARDOUS !!! DO NOT TOUCH ANY
BMS ON/OFF Together with the adjustable 50A input this it will be disconnected. conduits, cable size should double. Cable length breaker rated at 50A max or less. LIVE WIRED PARTS OF THE MCB MCB MCB MCB MCB MCB
all adds up to the max sum of input and AC Out-2 supports up to 35A. stands for the distance between the battery and the This depends heavily on the size of the INSTALLATION !!! WHEN IN DOUBT,
output current of 50+25=75A. An Earth An Earth leakage device with breaker or a MultiPlus connections !!! Recommendations are connected power source. The input current ALWAYS CONSULT
leakage device with breaker or a combination MCB/RCD must be installed on without other loads in the system and these also must be adjusted to fit the size of its YOUR VICTRON DEALER !!!
combination MCB/RCD must be installed the output for each 120V leg and 240V. should be taken into account for proper main connected power source.
CERBO on the output for each 120V leg and 240V. Cable size must be adjusted accordingly. battery, main fuse & main switch cables !!! The breaker and cable size for AC IN MultiPlus-II MultiPlus-II MultiPlus-II MultiPlus-II MultiPlus-II MultiPlus-II
1A Cable size must be adjusted accordingly. Fuse size should be 400A. should be adjusted accordingly. AC out L1 AC out L2 240V out AC out L1 AC out L2 240V out
SBP PRE-ALARM PIEZO BUZZER
0.5A
Pre-Alarm
0.2A 120V L1 No Break load-1 120V L1 Switched load-1
120V L1 No Break load-2 120V L1 Switched load-2
FUSES 120V L2 No Break load-1 120V L2 Switched load-1
12 Volt 30mA 120V L2 No Break load-2 120V L2 Switched load-2
240V L1-L2 No Break load-1 240V L1-L2 Switched load-1
240V L1-L2 No Break load-2 240V L1-L2 Switched load-2