You are on page 1of 4

Contract No:

PT. TRANSPORTASI GAS


INDONESIA 1FAP-043797

Document No:
PT. SOLUSI ENERGY
NUSANTARA MRU3401-EN-DS-P-003-A4

PT. PRATIWI PUTRI SULUNG Page 1 of 4

ENGINEERING, PROCUREMENT, CONSTRUCTION AND COMMISSIONING


(EPCC)
MERCURY REMOVAL UNIT (MRU) AT PEMPING STATION

PROCESS DATASHEET FOR MERCURY GUARD BED

0 28/06/2023 APPROVED FOR CONSTRUCTION YST RKA YP

A 27/06/2023 ISSUED FOR APPROVAL YST RKA YP

DISIAPKAN DIPERIKSA DISETUJUI


REV TANGGAL URAIAN
PT. PRATIWI PUTRI SULUNG
Doc. No : MRU3401-EN-DS-P-003-A4
EPCC MERCURY REMOVAL UNIT
(MRU) AT PEMPING STATION
Rev 0

PROCESS DATASHEET FOR MERCURY


Page 2 of 4
GUARD BED

HISTORY PERUBAHAN

Rev No Tanggal Halaman Deskripsi

A 27 JUNI 2023 All ISSUED FOR APPROVAL

0 28 JUNI 2023 3, 4 Penambahan notes


Doc. No : MRU3401-EN-DS-P-003-A4
EPCC MERCURY REMOVAL UNIT (MRU) AT
PEMPING STATION
Rev 0

PROCESS DATASHEET FOR


Page 3 of 4
MERCURY GUARD BED
1 CLIENT : PT. TRANSPORTASI GAS INDONESIA
2 SERVICE : MERCURY REMOVAL UNIT
3 P & ID : MRU3401-EN-DWG-P-005-A3
4 EQUIP. NAME : MRU Guard Bed
5 TAG NUMBER : 25NAF-531A/B/C
6 DESIGN CODE : ASME Section VIII Div.2
7 OPERATING : 3 x 50%
DESIGN CONDITION COMPOSITION, %mol
8 Fluid Natural Gas (Non Lethal) Methane 83.96623
9 Vessel Type Vertical Ethane 7.42388
10 Quantity unit 3 Propane 2.07533
11 Flowrate mmscfd 275 i-Butane 0.24677
Mass Flow n-Butane 0.27271
12
Gas Liquid lb/hr 292.766 - i-Pentane 0.08776
Mass Density n-Pentane 0.05491
13
3 2.046 54.11 n-Hexane 0.02942
Gas Liquid lb/ft
Mol. Weight n-Heptane 0.02196
14
Gas Liquid 19.39 18.70 n-Octane 0.01222
15 Viscosity Nonane+ 0.00461
Gas Liquid cP 0.0125 0.7034 Water 0.00341
16 Cp/Cv (Gas) 1.232 H2S 0.00018
17 Compressibility (Gas) 0.9006 CO2 4.21853
Size Vessel Diameter mm 5300 (NOTE 1) N2 1.58208
18 Length mm 2500 (NOTE 1)
Volume m3 29.4 (NOTE 1)
0 150
Temperature Design F
19
0 85
Operating F
Pressure Design psig 1650
20 Operating NOTE 5
Min / Max psig 550 / 915
DESIGN CRITERIA
Mercury Content Average 150 µg/Nm 3
Spike up to 250 µg/Nm 3
21

Mercury Content Outlet 10 µg/Nm 3


Doc. No. : MRU3401-EN-DS-P-003-A4
EPCC MERCURY REMOVAL UNIT (MRU) AT
PEMPING STATION
Rev 0

PROCESS DATASHEET FOR MERCURY


Page 4 of 4
GUARD BED
1 NOZZLE SCHEDULE Rev
2 MARK QTY SIZE RATING TYPE DESCRIPTION REMARK
3 N1 1 16 #900 WN RTJ INLET
4 N2 1 16 #900 WN RTJ OUTLET
5 N3 1 2 #900 WN RTJ PRESSURE INDICATOR
6 N4 1 2 #900 WN RTJ SPARE
7 N5 1 2 #900 WN RTJ VENTING
8 N6 DELETED
9 N7 1 2 #900 WN RTJ TEMPERATURE TRANSMITTER
10 N8 1 2 #900 WN RTJ SAMPLING POINT
11 N9 1 2 #900 WN RTJ SAMPLING POINT
12 N10 1 2 #900 WN RTJ SAMPLING POINT
13 N11 1 6 #900 WN RTJ PRELIMINARY DRAWING, NOTE 1
14 N12 1 2 #900 WN RTJ SPARE

DRAWING SKETCH OF MERCURY GUARD BED

NOTE 3

INTERNAL PART
15 Internal Part : AxTrap 273
16 Material : Metal Sulfide on Macroporous Alumina Pressure Drop : NOTE 4 psi (Clean)
: NOTE 4 psi (Dirty)
NOTES
1 Vendor to Advise size of Mercury Guard Bed (25NAF-53 A/B/C)
2 Size of Mercury Guard Bed (25NAF-53 A/B/C) is designed to treat 275 MMSCFD Gas with Average Mercury content of 150 µg/Nm, peak Mercury
Content at 250 µg/Nm3 and reducing it to 10 µg/Nm3. At minimum Operating Pressure 550 Psig
3 Nozzle size, Location, and Number of Nozzle to be confirmed by Vendor
4 Vendor to Advise Pressure Drop
5 Normal Operating Pressure 650 Psig

You might also like