You are on page 1of 2

ICRU 58 (Dose and Volume Specification for Reporting Interstitial Therapy), by

International Commission on Radiation Units and Measurements


Rupak K. Das

Citation: Medical Physics 25, 1225 (1998); doi: 10.1118/1.598300


View online: http://dx.doi.org/10.1118/1.598300
View Table of Contents: http://scitation.aip.org/content/aapm/journal/medphys/25/7?ver=pdfcov
Published by the American Association of Physicists in Medicine

Articles you may be interested in


Sensitivity of volumetric modulated arc therapy patient specific QA results to multileaf collimator errors and
correlation to dose volume histogram based metrics
Med. Phys. 40, 111715 (2013); 10.1118/1.4824433

Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-
modulated radiation therapy
Med. Phys. 33, 770 (2006); 10.1118/1.2170598

Dosimetry for ocular proton beam therapy at the Harvard Cyclotron Laboratory based on the ICRU Report 59
Med. Phys. 29, 1953 (2002); 10.1118/1.1487425

Specification of the physical and biologically effective absorbed dose in radiation therapies utilizing the boron
neutron capture reaction
Med. Phys. 27, 266 (2000); 10.1118/1.598888

High dose-rate brachytherapy treatment delivery: Report of the AAPM Radiation Therapy Committee Task Group
No. 59
Med. Phys. 25, 375 (1998); 10.1118/1.598232
BOOKS AND PUBLICATIONS

Book Reviews comed and long needed work in the litera- New Developments in Interstitial Re-
ture of brachytherapy and an important ad- mote Controlled Brachytherapy. N.
dition to the brachytherapy professional’s Zamboglou. W. Zuckschwerdt Verlag,
ICRU 58 „Dose and Volume Specifica-
bookshelf. Clearly this report should be an München, Germany. 189 pp. Price: $56.00.
tion for Reporting Interstitial Therapy….
excellent choice for any professionals in- A Primer on Theory and Operation
International Commission on Radiation
volved in the practice of brachytherapy. of Linear Accelerators in Radiation
Units and Measurements. 35 pp. Bethesda,
Therapy. Second Edition. C. J. Karzmark
Maryland, 1997. ISBN: 0-913394-57-2. Reviewed by Rupak K. Das and R. J. Morton. Medical Physics Pub-
Price: $35.00.
Rupak K. Das, Ph.D., is an assistant pro- lishing, Madison, Wisconsin. Price:
This report is an excellent guide for the
fessor of Human Oncology and Medical $26.95.
brachytherapy community. It is well orga-
Physics at the University of Wisconsin Good Practices in Health Physics.
nized in four sections and four appendices.
Medical School in Madison, Wisconsin. Proceedings of the HPS 31st Midyear
Its primary achievement is its consistent
Topical Meeting. Gregory R. Komp and
description of any interstitial implant. The
Michael A. Thompson. Medical Physics
report is intended for radiation oncologists,
Publishing, Madison, Wisconsin. 280 pp.
therapy physicists, dosimetrists and stu-
Price: $35.95.
dents of radiation therapy. With the advent
Introduction to Clinical Radiation
of computerized treatment planning sys- Books Received Oncology. Lawrence R. Coia and David J.
tems with 3D source location capabilities
Moylan. Medical Physics Publishing,
and a wide array of radionuclides with dif-
The editor acknowledges receipt of the fol- Madison, Wisconsin. 605 pp. Price:
ferent activities, the brachytherapy com-
lowing publications which may be re- $48.95.
munity has come a long way from the es-
viewed in later issues if they are judged to Understanding Helical Scanning.
tablished classical implant systems. The be of sufficient interest to the majority of Cheryl Blanck. Williams and Wilkins, Bal-
main aim of this report is to develop a readers, subject to space limitations. Read- timore, Maryland. 80 pp. Price: $24.95.
common method of analyzing an intersti- ers interested in reviewing books should Helical „Spiral… Computed Tomogra-
tial implant without encouraging users to advise the Book Review Editor of their phy: A Practical Approach to Clinical
depart from their normal practice. It will availability, qualifications, and interests. Protocols. Paul M. Silverman. Lippincott-
help many radiation oncology departments Radiologic Interventions: Uroradiol- Raven Publishers, Philadelphia, Pennsyl-
to follow this guideline and develop a pro- ogy. Marc P. Banner, M. D. Williams and vania. 304 pp. Price: $49.95.
tocol of their own in achieving a reason- Wilkins, Baltimore, Maryland. 213 pp. Maria Sklodowska-Curie: Memorial
able dose uniformity for a given implant. Price: $69.00. Issue. Edward Towpik and Richard F.
This report does an excellent job in defin- Nuclear Medicine Physics: The Ba- Mould. Publishing House of the Polish
ing the volumes ~GTV, CTV, and PTV! sics. ~5th Edition!. Ramesh Chandra. Wil- Foundation of the European School of On-
based on general oncological principles liams and Wilkins, Baltimore, Maryland. cology, Warsaw, Poland. 107 pp.
~ICRU 50! and as such making it analo- 182 pp. Price: $39.00.
gous to its external beam counterpart. Fol- Shielding Techniques For Radiation
lowing these guidelines for reporting dose Oncology Facilities. Patton H. McGinley.
will certainly help the brachytherapy field Medical Physics Publishing, Madison, Recommended Standards for the Rou-
in the future, to compare results and hence Wisconsin. 147 pp. Price: $62.95. tine Performance Testing of Diagnostic
relate the outcome of a treatment. Nuclear Methods in Science and X-Ray Imaging Systems. Report No. 77.
Overall, this report is an important ad- Technology. Yu M. Tsipenyuk. Institute Institute of Physics and Engineer-ing in
dition to brachytherapy literature and is of Physics Publishing, Philadelphia, Penn- Medicine, York, England. 64 pp. Price:
highly recommended. Its clear presenta- sylvania. 454 pp. Price: $150.00. £10.00.
tions, simple and easy-to-follow illustra- Catalogue of Diagnostic X-ray Spec- Dose and Volume Specification for
tions and instructional diagrams and ap- tra and Other Data. Report No. 78. Insti- Reporting Interstitial Therapy. Report
pendices make it useful for these reasons tute of Physics and Engineering in Medi- 58. International Commission on Radiation
alone. With the addition of guidelines for cine, York, United Kingdom. CD-ROM. Units and Measurements, Bethesda, Mary-
interstitial implants, it becomes a wel- Price: 20£. land. 35 pp. Price: $35.00.

1225 Med. Phys. 25 „7…, July 1998, Part 1 © 1998 Am. Assoc. Phys. Med. 1225

You might also like