You are on page 1of 1

KHALDA PETROLEUM COMPANY

A/G CHEMICAL LAB. &WATER MAKER DIV.

Date : 18-Jan-23

PETROSANNAN GAS ANALYSIS REPORT

Compressor Compressor
Source
suction discharge

TIME 11AM 11AM


N2 0.561 0.539
C1 78.321 80.023
CO2 0.634 0.576
C2 10.170 10.172
C3 5.501 5.259
I-C4 1.211 1.059
N-C4 1.792 1.473
I-C5 0.691 0.434
N-C5 0.561 0.309
C6+ 0.558 0.156

TOTAL 100.000 100.000


TEMP.
PRESS. 23 psi 670 psi

GROSS HEATING VALUE btu/ ft3 1283.95 1240.23

Sp.Gr. 0.748 0.717


Mol. Wt 21.648 20.772
Density (kg/m³) 0.912 0.875
H2S(ppm)
C4 3.003 2.532
C5+ 1.810 0.899

CHEM.LAB.Dept. Head CHEM.LAB. ASST. GEN.MGR.