AIR FILTERS

Non Return Damper


Gravity Louver
Pressure Relief Damper
1 a perfect partner in performance...
Airwellcare Products are Tested & Certified by various International Labs.
Air Filters

INTRODUCTION

The use of AIRWELLCARE Synthetic Air Air filters used in ventilating


Filter Media within frame system are systems are used to remove an
ideal for those specialized applications, extremely wide variety of
where a high level of filtration are contaminants from the air, rang-
required for low air flow applications. ing from dust and smoke to bac-
teria, mold and spores. It is im-
portant to select the exact type
The replacement Synthetic Air Fil- of filter based on the criteria.
ter Medias are available to meet a
wide range of filter requirements from The recent scientific evidences that
coarse to fine, some products be- shows the indoor air quality is on
ing able to withstand a light cleaning average 4 times (occasionally 100
operation & others being disposable times) more polluted and harmful to
human health than the air outdoors.

APPLICATIONS

All Kinds of HVAC Onshore & Offshore


applications with Applications
high relative
humidity

All Kinds of
Cement Factories & Ventilation & Airconditioning
Power Plants Systems

3 a perfect partner in performance...


Pleated Panel Filters

MODEL AHS PF 100


Airwellcare Synthetic Panel Filter
Media are available to meet a wide range of
filter requirements in Residential, Industrial
& Oil Field Applications.

Construction Details
Standard Depth AHS PF 100

1/2 Inch, 1.0 Inch, 2.0 Inches upto 4 Inches.

Filter Class
G-4 Based on EN 779 : 2012

Frame / Housing
1.0mm Thick. Galvanized Steel Front View
Construction.

Stainless Steel Construction with


different Grades are optional.

Isometric View

a perfect partner in performance... 4


Pleated Panel Filters

Engineering Guidelines

MODEL AHS PF 100

Air Velocity & Pressure Drop

5 a perfect partner in performance...


Synthetic Flat Filters

Construction Details

Airwellcare Synthetic Flat Filter Media


are available to meet a wide range of filter
requirements in Residential, Industrial & Oil
Field Applications.
AHS PF 200

Standard Depth
1/2 Inch, 1.0 Inches.

Filter Class
G-3, G-4 & G-5 Based on EN 779 : 2012

The High dust holding capacity non-woven


synthetic polyester media reinforced with Front Airwellcare Polyfiber Flat
& Rear secured with PVC coated wire mesh Filters are cleanable / washable
assembled in flat and encased with metal frames. panel filters made up of non-woven, high
lofted synthetic (polyester) filter media
and are available in various
Frame / Housing efficiency grades ranging from G2 to G4,
having very high dust Arrestance and dust
1.0mm Thick. Galvanized Steel holding capacity than the other
Construction. types of similar grade panel filters.

Airwellcare Polyfiber Filters are


widely used in Fan Coil
Units, Packaged Units
and AHUs for various HVAC applications.

A PVC Coated Wire Mesh having 98%


Open Area is provided on the up-
stream and downstream which re-
inforces & supports the filter media.

a perfect partner in performance... 6


Synthetic Flat Filters

Engineering Guidelines

7 a perfect partner in performance...


Synthetic Flat Filters

Operational & Maintenance

This manual will be of use to all Do not change air filters when the
those directly involved with the HVAC system is operating.
correct and proper installation,
Operation & Maintenance Check the Pressure Drop. If it reaches
of air filtration systems. to final value (PD), Replace or Clean it
properly.

The particles stay in the Filter and fill Rule of thumb: Clean every 3 months.
in filter fibers, reducing the spaces If the air in the room is extremely
through which air can flow. This restric- contaminated, increase the cleaning
tion causes an increase in the resist- frequency, which is also depends on
ance to the airflow through the filter. the Climatic / Weather conditions.

Randomnly check the Filter for dust


Push the Air Filter towards up with the accumulation.
help of given Handles and remove the Fil-
ter. The same way reattach the Filter in Clean the filter with lukewarm water
place after Cleaning. or detergent.

Dry the air filter, prior to reinstall in


Visually inspect the filters. If the filter place.
media appears damaged in any way, or
if the media becomes wet, the prefilters
should be changed immediately.

a perfect partner in performance... 8