You are on page 1of 18

SLAB (RCD)

SLAB – 1 (S-1)
(Adapt to all SLAB- 1/ S-1)

1. Check

Lb 3.5
m= = = 1.50, considered One-way Slab
La 2.33

2. Thickness of Slab

L 2330
t= = = 116.5 mm say 200 mm
20 20

3. Effective Depth

∅ 12
d = t – 25 – = 200 – 25 – = 169 mm
2 2

4. Loads (Consider 1 m strip)

Floor Finishes + Ceiling Load = 1 kN/m2

Weight of Slab = (23.54) (0.2) = 4.71 kN/m2

Dead Load = (23.54) (0.2) + 1 = 5.71 kN/m2

Live Load = (2.4) (1) = 2.4 kN/m2

5. Factored Load

WDL = 1.2DL = (1.2) (5.71) = 6.85 kN/m

WLL = 1.6LL = (1.6) (2.4) = 3.84 kN/m


6. Wu = (6.85 + 3.84) (1m) = 10.69 kN/m

7. Moment at Midspan
2 2
WuL 10.69(2.33)
M midspan= = = 7.25 kN.m
8 8

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Ma = Ø fc’bd2 w (1-.59w)

7.25 x 106 = 0.90 (21) (1000) (169)2(w)(1-0.59w)

w= 0.014

wfc ' 0.014(21)


p= = = 0.0011
fy 276
1.4 1.4
pmin= = = 0.0051 (adapt)
fy 276

As = pbd

As= (0.0051) (1000) (169) = 862 mm2

1000 Ao 113(1000)
S= = = 131.1 mm say 100 mm
As 862

9. Temperature Bars

Use 10 mm Ø of bar, Grade 300

Ast= 0.002 bt= 0.002 (1000) (200)

Ast= 400 mm2

1000 Ao 78.54(1000)
S= = = 196.35 mm say 150 mm
Ast 400
SLAB – 2 (S-2)
(Adapt to all SLAB- 2/ S-2)

1. Check

Lb 4.5
m= = = 1.93, considered One-way Slab
La 2.33

2. Thickness of Slab

L 2330
t= = = 116.5 mm say 200 mm
20 20

3. Effective Depth

Ø 12
d = t – 25 – = 200 – 25 – = 169 mm
2 2

4. Loads (Consider 1 m strip)

Floor Finishes + Ceiling Load = 1 kN/m2

Weight of Slab = (23.54) (0.2) = 4.71 kN/m2

Dead Load = (23.54) (0.2) + 1 = 5.71 kN/m2

Live Load = (4.8) (1) = 4.8 kN/m2

5. Factored Load

WDL = 1.2DL = (1.2) (5.71) = 6.85 kN/m


WLL = 1.6LL = (1.6) (4.8) = 7.68 kN/m

6. Wu = (6.85+ 7.68) (1m) = 14.53 kN/m

7. Moment at Midspan
2
W u L 1 4 .53(2.33)2
M midspan= = = 9.86 kN.m
8 8

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Ma = Ø fc’bd2 w (1-.59w)

9.86 x 106 = 0.90 (21) (1000) (169)2(w)(1-0.59w)

w= 0.019

wfc ' 0.01 9(21)


p= = = 0.0015
fy 276

1.4 1.4
pmin= = = 0.0051 (adapt)
fy 276

As = pbd

As= (0.0051) (1000) (169) = 862 mm2

1000 Ao 113(1000)
S= = = 131.1 mm say 100 mm
As 862

9. Temperature Bars

Use 10 mm Ø of bar, Grade 300

Ast= 0.002 bt= 0.002 (1000) (200)

Ast= 400 mm2


1000 Ao 78.54(1000)
S= = = 196.4 mm say 150 mm
Ast 400

SLAB – 3 (S-3)
(Adapt to all SLAB-3 / S-3)

1. Check

Lb 3.50
m= = = 1.17, considered One-way Slab
La 3

2. Thickness of Slab

L 3000
t= = = 150 mm say 200 mm
20 20

3. Effective Depth

Ø 1
d =t – 25 – = 200 – 25 – (12) = 169 mm
2 2

4. Loads (Consider 1 m strip)

Floor Finishes and Ceiling Load = 1 kN/m2

Weight of Slab = (23.54) (0.2) = 4.71 kN/m2

Dead Load = (23.54) (0.2) + 1 = 5.71 kN/m2

Live Load = 1.9 (1) = 1.9 kN/m2


5. Factored Load

WDL = 1.2DL = (1.2) (5.71) = 6.85 kN/m

WLL = 1.6LL = (1.6) (1.9) = 3.04 kN/m

6. Wu = (6.85 + 3.04) (1) = 9.89 kN/m

7. Moment at Midspan
2 2
WuL 9.89(3)
M midspan= = = 11.13 kN.m
8 8

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Along Short Span

Ma = Ø fc’bd2 w (1-.59w)

11.13 x 106 = 0.90 (21) (1000) (169)2w (1-0.59w)

w= 0.021

p = wfc ' = 0.021(21) = 0.0016


fy 276

1.4 1.4
pmin= = = 0.0051 (adapt)
Fy 276

As = pbd= 0.0051 (1000) (169) = 862 mm2

1000 Ao 1000(113)
S= = = 131.1 mm say 100 mm
As 862

9. Temperature Bar

Use 10 mm Ø of bar, Grade 300


Ast= 0.002 bt = 0.002 (1000) (200)

Ast= 400 mm2

1000 Ao 78.54(1000)
S= = = 196.4 mm say 150 mm
Ast 400

SLAB – 4 (S-4)
(Adapt to all SLAB- 4/ S-4)

1. Check

Lb 4.5
m= = = 1.8, considered One-way Slab
La 2.5

2. Thickness of Slab

L 2500
t= = = 125 mm say 200 mm
20 20

3. Effective Depth

Ø 1
d = t – 25 – = 200 – 25 – 12 ( ) = 169 mm
2 2

4. Loads (Consider 1 m strip)

Floor Finishes + Ceiling Load = 1 kN/m2

Weight of Slab = (23.54) (0.2) = 4.71 kN/m2

Dead Load = (23.54) (0.2) + 1 = 5.71 kN/m2


Live Load = (4.8) (1) = 4.8 kN/m2

5. Factored Load

WDL = 1.2DL = (1.2) (5.71) = 6.85 kN/m

WLL = 1.6LL = (1.6) (4.8) = 7.68 kN/m

6. Wu = (6.85 + 7.68) (1m) = 14.53 kN/m

7. Moment at Midspan
2
WuL
M midspan= = 14.53 ¿ ¿ 11.35 kN.m
8

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Ma = Ø fc’bd2 w (1-.59w)

11.35 x 106 = 0.90(21) (1000) (169)2(w)(1-0.59w)

w= 0.021

wfc ' 0.021(21)


p= = = 0.0016
fy 276

1.4 1.4
pmin= = = 0.0051 (adapt)
fy 276
As = pbd

As= (0.0051) (1000) (169) = 862 mm2

1000 Ao 113(1000)
S= = = 131.1 mm say 100 mm
As 862
9. Temperature Bars

Use 10 mm Ø of bar, Grade 300

Ast= 0.002 bt= 0.002 (1000) (200)

Ast= 400 mm2

1000 Ao 78.54(1000)
S= = = 196.4 mm say 150 mm
Ast 400

SLAB – 5 (S-5)
(Adapt to all SLAB- 5/ S-5)

1. Check

Lb 3.50
m= = = 1.75, considered One-way Slab
La 2

2. Thickness of Slab

L 2000
t= = = 200 mm
10 10

3. Effective Depth

Ø 1
d = t – 25 – = 200 – 25 – 12 ( ) = 169 mm
2 2

4. Loads (Consider 1 m strip)

Floor Finishes + Ceiling Load = 1 kN/m2


Weight of Slab = (23.54) (0.2) = 4.71 kN/m2

Dead Load = (23.54) (0.2) + 1 = 5.71 kN/m2

Live Load = (1.9) (1) = 1.9 kN/m2

5. Factored Load

WDL = 1.2DL = (1.2) (5.708) = 6.85 kN/m

WLL = 1.6LL = (1.6) (1.9) = 3.04 kN/m

6. Wu = (6.85 + 3.04) (1m) = 9.89 kN/m

7. Moment at Support
2 2
WuL 9.89 ( 2 )
Msupport = = = 19.78 kN.m
2 2

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Ma = Ø fc’bd2 w (1-.59w)

19.78 x 106 = 0.90(21) (1000) (169)2(w)(1-0.59w)

w= 0.038

wfc ' 0.038(21)


p= = = 0.0029
fy 276

1.4 1.4
pmin= = = 0.0051 (adapt)
fy 276

As = pbd

As= (0.0051) (1000) (169) = 862 mm2


1000 Ao 113(1000)
S= = = 131.11 mm say 100 mm
As 862

9. Temperature Bars

Use 10 mm Ø of bar, Grade 300

Ast= 0.002 bt= 0.002 (1000) (200)

Ast= 400 mm2

1000 Ao 78.54(1000)
S= = = 196.35 mm say 150 mm
Ast 400

SLAB – 6 (S-6)
(Adapt to all SLAB- 6/ S-6)

1. Check

Lb 3.5
m= = = 2.92 > 2 Therefore, One Way Slab
La 1.2

2. Thickness of Slab

L 1200
t= = = 120 mm say 150
10 10

3. Effective Depth

Ø 1
d = t – 25 – = 150 – 25 – 12 ( ) = 119 mm
2 2
4. Loads (Consider 1 m strip)

Floor Finishes + Ceiling Load = 1 kN/m2

Weight of Slab = (23.54) (0.15) = 3.53 kN/m2

Dead Load = (23.54) (0.15) + 1 = 4.53 kN/m2

Live Load = (2.4) (1) = 2.4 kN/m2

5. Factored Load

WDL = 1.2DL = (1.2) (4.53) = 5.44 kN/m

WLL = 1.6LL = (1.6) (2.4) = 3.84 kN/m

6. Wu = (5.44 + 3.84) (1m) = 9.28 kN/m

7. Moment at Support
2 2
WuL 9.28 ( 1.2 )
Msupport = = = 6.68 kN.m
2 2

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Ma = Ø fc’bd2 w (1-.59w)

6.68 x 106 = 0.90(21) (1000) (119)2(w)(1-0.59w)

w= 0.025

wfc ' 0.025(21)


p= = = 0.0019
fy 276

1.4 1.4
pmin= = = 0.0051 (adapt)
fy 276
As = pbd
As= (0.0051) (1000) (119) = 607 mm2

1000 Ao 113(1000)
S= = = 186.16 mm say 150 mm
As 607

9. Temperature Bars

Use 10 mm Ø of bar, Grade 300

Ast= 0.002 bt= 0.002 (1000) (150)

Ast= 300 mm2

1000 Ao 78.54(1000)
S= = = 262 mm say 250 mm
Ast 300

SLAB – 7 (S-7)
(Adapt to all SLAB- 7/ S-7)

1. Check

Lb 18
m= = = 15 > 2 Therefore, One Way Slab
La 1.2

2. Thickness of Slab

L 1200
t= = = 120 mm say 200 mm
10 10

3. Effective Depth

Ø 1
d = t – 25 – = 200 – 25 – 12 ( ) = 169 mm
2 2
4. Loads (Consider 1 m strip)

Floor Finishes + Ceiling Load = 1 kN/m2

Weight of Slab = (23.54) (0.2) = 4.71 kN/m2

Dead Load = (23.54) (0.2) + 1 = 5.71 kN/m2

Live Load = (4.8) (1) = 4.8 kN/m2

5. Factored Load

WDL = 1.2DL = (1.2) (5.71) = 6.85 kN/m

WLL = 1.6LL = (1.6) (4.8) = 7.68 kN/m

6. Wu = (6.85 + 7.68) (1m) = 14.53 kN/m

7. Moment at Support
2 2
WuL 14.53 (1.2 )
Msupport = = = 10.46 kN.m
2 2

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Ma = Ø fc’bd2 w (1-.59w)

10.46 x 106 = 0.90(21) (1000) (169)2(w)(1-0.59w)

w= 0.02

wfc ' 0.02(21)


p= = = 0.0015
fy 276

1.4 1.4
pmin= = = 0.0051 (adapt)
fy 276
As = pbd

As= (0.0051) (1000) (169) = 862 mm2

1000 Ao 113(1000)
S= = = 131.1 mm say 100mm
As 862

9. Temperature Bars

Use 10 mm Ø of bar, Grade 300

Ast= 0.002 bt= 0.002 (1000) (200)

Ast= 400 mm2

1000 Ao 78.54(1000)
S= = = 196.4 mm say 150 mm
Ast 400

SLAB – 8 (S-8)
(Adapt to all SLAB- 8/ S-8)

1. Check

La 4.5
m= = = 5.625 < 2 Therefore, One Way Slab
Lb 0.80

2. Thickness of Slab

L 800
t= = = 80 mm say 100 mm
10 10

3. Effective Depth
1 1
d = t – 25 – = 100– 25 – 12 ( ) = 69 mm
2 2

4. Loads (Consider 1 m strip)

Floor Finishes + Ceiling Load = 1 kN/m2

Weight of Slab = (23.54) (0.1) = 2.35 kN/m2

Dead Load = (23.54) (0.1) + 1 = 3.35 kN/m2

Live Load = (2.4) (1) = 2.4 kN/m2

5. Factored Load

WDL = 1.2DL = (1.2) (3.35) = 4.02 kN/m

WLL = 1.6LL = (1.6) (2.4) = 3.84 kN/m

6. Wu = (4.02 + 3.84) (1m) = 7.86 kN/m

7. Moment at Support
2 2
W L 7.86 ( 0.80 )
Msupport = u = = 2.52 kN.m
2 2

8. Area of Reinforcement and Spacing at Support

Use 12 mm Ø of bar

Ma = Ø fc’bd2 w (1-.59w)

2.52 x 106 = 0.90(21) (1000) (69)2(w)(1-0.59w)

w= 0.028

wfc ' 0.028(21)


p= = = 0.0021
fy 276
1.4 1.4
pmin= = = 0.0051 (adapt)
fy 276
As = pbd

As= (0.0051) (1000) (69) = 352 mm2

1000 Ao 113(1000)
S= = = 321 mm say 300 mm
As 352

9. Temperature Bars

Use 10 mm Ø of bar, Grade 300

Ast= 0.002 bt= 0.002 (1000) (100)

Ast= 200 mm2

1000 Ao 78.54(1000)
S= = = 393 mm say 350 mm
Ast 200

You might also like