Table of Contents
Stock Beams, Custom Beams, I-Joist Compatible (IJC) . . . . . . . . . . . 2 Allowable Holes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Balanced and Unbalanced Beam Layups, Layup Combinations . . . . . 3 BOISE GLULAMTM Beams Roof Load Tables - 115% . . . . . . . . 15 - 19
Deflection & Camber, Adhesives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 BOISE GLULAMTM Beams Roof Load Tables - 125% . . . . . . . . 20 - 24
Checking, Handling & Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 BOISE GLULAMTM Beams Floor & Roof Application Tables . . 25 - 29
Dimensional Tolerances, Preservative Treatment Requirements . . . . . 5 BOISE GLULAMTM Beams Substitution Tables - Steel . . . . . . . . . . . . 30
Fire Resistance, Field Notching & Drilling . . . . . . . . . . . . . . . . . . . . . 5 BOISE GLULAMTM Beams Substitution Tables - Solid Sawn . . . . . . . 31
BOISE GLULAMTM Building Code Evaluations . . . . . . . . . . . . . . . . . . 5 BOISE GLULAMTM Beams SIMPSON Hanger Tables . . . . . . . . . . . . 32
BOISE GLULAMTM Design Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 BOISE GLULAMTM Beams USP Hanger Tables . . . . . . . . . . . . . . . . 33
BOISE GLULAMTM Allowable Design Stresses . . . . . . . . . . . . . . . . . . 6 BOISE GLULAMTM Beams Computer Software . . . . . . . . . . . . . 34 - 35
Column Tables & Allowable Stresses . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Website and SFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover
BOISE GLULAM™ Beam and Column Size 3
51/8" 63/4" 83/4" 51/2"
31/8" 31/2"
7 /2" 9" 31/8" to 63/4"
6" 1
9"
6" to to to 71/2" to 51/8"
to 24" 24" 15" to 12" to
18" 15"
71/2"
LAYUP COMBINATIONS
Balanced Versus Unbalanced Layup Example
No. 2D T.L.
No. 2 No. 1
No. 2 No. 2
No. 3 No. 3
No. 2 No. 2
No. 1 No. 1
T.L. T.L.
Unbalanced Balanced
(V4) (V8)
T.L. = Tension Lamination
4 Technical Items
12 16 20 24 28 32 36 40 44 48 52 56 60
0.06 0.11 0.17 0.25 0.34 0.44 0.56 0.69 0.83 0.99 1.16 1.34 1.54 Example of Checking
Camber is specified mostly to reduce the aesthetic
effect of long-span members. Camber can also be
HANDLING & STORAGE
Water-resistant wrapping is often specified to protect
specified to reduce the amount of deflection — for
beams from moisture, soiling, and surface scratches
example, it may be used to limit water collection on during transit and job-site storage. Because
near-flat roofs. exposure to sunlight can discolor beams, opaque
wrappings are recommended. Beams can be
wrapped individually or by the bundle. In applications
where appearance is especially important, individual
ADHESIVES wrapping should be left intact until installation to
minimize exposure to job-site conditions.
BOISE GLULAMTM beams are manufactured with
Beams are commonly loaded and unloaded with
exterior-grade or wet-use adhesives that comply with
forklifts. For greater stability, the sides of the
all recognized national glulam standards. The pur- beams, rather than the bottoms, should rest on the
pose of exterior-grade adhesives is to ensure that forks. Supporting extremely long beams on their
the design values of the beams are not compromised sides, however, can cause them to flex excessively,
when the beams are directly exposed to the weather increasing the risk of damage. Use multiple forklifts
during construction. Though wet-use adhesives are to lift long beam members.
required when glulam beams exceed a moisture A level, well-drained, covered storage site is recom-
content of 16% for extended periods of time after mended. Keep beams off the ground, using
installation, the beams still must be protected from lumber blocking, skids, or a rack system. Keep
beams level. The wrapping on beams should be
exterior exposure. (For applications where moisture
left in place to protect them from moisture, soiling,
content may exceed 19%, see Preservative Treatment.) sunlight, and scratches. For long-term storage, cut
(ANSI/AITC Standard A190.1-2002 American National slits in the bottom of the wrapping to allow ventilation
Standard for Structural Glued Laminated Timber) and draining of any entrapped moisture. Proper
ventilation and drainage will reduce the likelihood of
water damage, staining, and the start of decay.
Technical Items 5
13 /2 1
10.3 7453 18984 640.7 9 14.8 10733 18225 410.1
15 11.4 8281 23438 878.9
101/2 17.2 12521 24457 651.2
161/2 12.5 9109 28359 1169.8
12 19.7 14310 31520 972.0
18 13.7 9938 33750 1518.8
71/2 6.4 4638 6563 123.0 131/2 22.1 16099 39425 1384.0
13 /2 1
16.8 12223 30770 1050.8 101/2 22.3 16231 30891 844.1
51/8 15 18.7 13581 37589 1441.4
83/4 12 25.5 18550 39812 1260.0
161/2 20.6 14939 45052 1918.5
131/2 28.7 20869 49798 1794.0
18 22.4 16298 53151 2490.8
191/2 24.3 17656 61881 3166.8 15 31.9 23188 60834 2460.9
Notes:
The data is for stock beams. For information on sizes not listed, please use BC CALC® software or consult- with Boise EWP Engineering.
Consult Boise EWP Engineering for additional design stresses for nonstandard applications and stability issues.
Column Table & Allowable Stresses 7
Horizontal Holes
Allowable Holes in Glulam Beams
See Note 3
1/3 Depth
1/3 Depth
1/3 Depth
Notes:
End Bearing Interior Bearing
1) Square and rectangular holes are not permitted. 6) These limitations apply to holes drilled for plumbing
2) Round holes may be drilled or cut with a hole saw or wiring access only. The size and location of holes
anywhere within the shaded area of the beam. drilled for fasteners are governed by the provisions
of the National Design Specification® for Wood
3) The horizontal distance between adjacent holes shall
Construction.
be at least two times the diameter of the larger hole.
7) Beams deflect under load. Size holes to provide
4) Do not drill more than three access holes in any 4-foot
clearance where required.
long section of beam.
8) This hole chart is valid for BOISE GLULAMTM beams
5) The maximum round hole diameter permitted is: supporting uniform load only. For beams supporting
9" & concentrated loads or for beams with larger or vertical
Beam Depth 6" & 71/2" greater holes, contact Boise EWP Engineering.
Common Details
G1 G2 G3
Beam Framing to Wall Beam Bearing for Header Beam to Wall with
Lateral
Beam Support
to Wall with Lateral Support
Beam Bearing for Header
Beam Framing to Wall
Strap per code if top plate is not BCI® Joist or engineered rimboard
continuous over beam blocking for lateral support
Strap per code if top plate is
not continuous over beam
P
P TO
TO
TO P
G4 G5 G6 G7
End Wall Bevel Plate Beam to Beam Beam to Concrete / Beam to Column
End Wall Bevel Plate Connection Masonry Wall Connection
Beam to Column Connection
Beam to Concrete/Masonry Wall
Beam to Beam Connection Minimum 1/2" air
space between
beam and
P
concrete/
TO
P
masonry wall
TO
Adequate
Lateral
Support TO
P Drilling permitted
P
P
TO for standard
TO
connections.
Should be
located in the
Verify hanger lower section of
Beveled Plate capacity with the beam to
manufacturer's Moisture barrier avoid splitting
specifications at bearing
BOISE GLULAM™
column or studs,
full width of beam
G8 G9 G10
Beam Depth Change at Sloped Seat Cut Bevel Cutting
Intermediate Support
Beam Depth Change
at Intermediate Support
• Both Architectural and Industrial appearance grade BOISE GLULAMSTM have the same structural • Table values for Minimum Required Bearing Lengths are based on the allowable compression
grade, 24F-V4. Appearance grade does not affect the beam's load capacity. design value perpendicular to grain for the beam and the load value shown. Other design
• Uniform PLF load values are limited by shear, moment, total load deflection limited to L/240 and live considerations, such as a weaker support material, may warrant longer bearing lengths. Table
load deflection limited to L/360. values assume that support is provided across the full width of the beam.
• Live load is equal to 0.8 of total load (residential loading). • This table was designed to apply to a broad range of applications. It may be possible to exceed the
limitations of this table by analyzing a specific application with the BC CALC® software.
• Span is measured center to center of the supports.
• Table values assume that lateral support is provided at each support and continuously along the
compression edge of the beam.
14 BOISE GLULAM™ Beams Floor Load Tables
Industrial Appearance Headers
3 /2" and 5 1/2" Floor Load Tables – 100%
1
3/"1
2 51/2"
Span Span
[ft] Type 7.5" 9" 10.5" 12" 13.5" 15" 9" 10.5" 12"
Simple 1452 2092 2758 3350 4021 4787 3288 4334 5264
6 Multiple 1118 1611 2036 2433 2869 3347 2532 3200 3824
Min. Bearing 1.9 / 3 2.8 / 3 3.6 / 3.4 4.4 / 4 5.3 / 4.7 6.3 / 5.5 2.8 / 3 3.6 / 3.4 4.4 / 4
Simple 795 1174 1599 2090 2618 3042 1844 2513 3284
8 Multiple 626 903 1230 1609 1939 2227 1419 1934 2528
Min. Bearing 1.5 / 3 2.1 / 3 2.8 / 3 3.7 / 3.6 4.6 / 4.3 5.4 / 4.9 2.1 / 3 2.8 / 3 3.7 / 3.6
Simple 404 701 1020 1334 1690 2087 1102 1603 2096
10 Multiple 398 575 784 1026 1300 1606 904 1232 1612
Min. Bearing 1.5 / 3 1.6 / 3 2.3 / 3 3/3 3.7 / 3.6 4.6 / 4.4 1.6 / 3 2.3 / 3 3/3
Simple 231 403 642 923 1170 1446 633 1009 1451
12 Multiple 275 397 542 709 899 1111 624 852 1115
Min. Bearing 1.5 / 3 1.5 / 3 1.7 / 3 2.5 / 3 3.1 / 3 3.8 / 3.7 1.5 / 3 1.7 / 3 2.5 / 3
Simple 143 251 401 602 856 1059 394 630 946
14 Multiple 190 290 396 518 657 813 455 622 815
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.9 / 3 2.7 / 3 3.3 / 3.2 1.5 / 3 1.5 / 3 1.9 / 3
Simple 94 165 266 400 573 788 260 418 628
16 Multiple 125 220 301 394 501 620 346 473 620
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 2.1 / 3 2.8 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple 64 114 184 278 399 550 179 289 437
18 Multiple 86 152 236 310 393 487 239 371 486
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.6 / 3 2.2 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - 81 132 200 288 397 127 207 314
20 Multiple - 109 176 249 316 392 171 277 390
Min. Bearing - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.8 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - 59 97 148 213 295 93 152 232
22 Multiple - 80 130 197 259 322 126 204 310
Min. Bearing - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 72 111 162 225 69 114 175
24 Multiple - - 98 150 216 268 94 154 235
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 55 85 125 174 51 87 134
26 Multiple - - 75 116 168 225 71 118 182
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - - 66 97 137 - 67 104
28 Multiple - - - 90 132 184 - 92 142
Min. Bearing - - - 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - 52 77 109 - 51 82
30 Multiple - - - 72 105 147 - 72 113
Min. Bearing - - - 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - - 62 87 - - 65
32 Multiple - - - - 85 119 - - 90
Min. Bearing - - - - 1.5 / 3 1.5 / 3 - - 1.5 / 3
Simple - - - - - 71 - - 51
34 Multiple - - - - - 97 - - 72
Min. Bearing - - - - - 1.5 / 3 - - 1.5 / 3
Simple - - - - - 58 - - -
36 Multiple - - - - - 80 - - -
Min. Bearing - - - - - 1.5 / 3 - - -
• Both Architectural and Industrial appearance grade BOISE GLULAMS have the same structural
TM
• Table values for Minimum Required Bearing Lengths are based on the allowable compression design
grade, 24F-V4. Appearance grade does not affect the beam's load capacity. value perpendicular to grain for the beam and the load value shown. Other design considerations,
• Uniform PLF load values are limited by shear, moment, total load deflection limited to L/240 and live such as a weaker support material, may warrant longer bearing lengths. Table values assume that
load deflection limited to L/360. support is provided across the full width of the beam.
• Live load is equal to 0.8 of total load (residential loading). • This table was designed to apply to a broad range of applications. It may be possible to exceed the
• Span is measured center to center of the supports. limitations of this table by analyzing a specific application with the BC CALC® software.
• Table values assume that lateral support is provided at each support and continuously along the
compression edge of the beam.
BOISE GLULAM™ Beams Roof Load Tables 15
Architectural Appearance Beams
3 /8" Roof Load Tables – 115% Snow
1
3/"
1
2 51/2"
Span Span
[ft] Type 7.5" 9" 10.5" 12" 13.5" 15" 9" 10.5" 12"
Simple 1671 2407 3173 3854 4625 5507 3783 4986 6056
6 Multiple 1286 1854 2343 2800 3301 3851 2913 3682 4400
Min. Bearing 2.2 / 3 3.2 / 3.1 4.2 / 3.9 5.1 / 4.6 6.1 / 5.5 7.3 / 6.4 3.2 / 3.1 4.2 / 3.9 5.1 / 4.6
Simple 937 1351 1840 2405 3013 3500 2123 2892 3779
8 Multiple 721 1039 1416 1851 2232 2563 1633 2226 2909
Min. Bearing 1.7 / 3 2.4 / 3 3.3 / 3.1 4.2 / 4.1 5.3 / 4.9 6.2 / 5.7 2.4 / 3 3.3 / 3.1 4.2 / 4.1
Simple 597 862 1174 1535 1945 2402 1354 1846 2413
10 Multiple 459 663 903 1181 1496 1849 1041 1419 1856
Min. Bearing 1.5 / 3 1.9 / 3 2.6 / 3 3.4 / 3.3 4.3 / 4.1 5.3 / 5.1 1.9 / 3 2.6 / 3 3.4 / 3.3
Simple 373 596 813 1063 1347 1664 937 1277 1671
12 Multiple 317 458 625 817 1036 1280 719 981 1284
Min. Bearing 1.5 / 3 1.6 / 3 2.2 / 3 2.8 / 3 3.6 / 3.5 4.4 / 4.3 1.6 / 3 2.2 / 3 2.8 / 3
Simple 233 406 595 778 987 1219 637 935 1223
14 Multiple 231 334 456 598 758 937 525 717 939
Min. Bearing 1.5 / 3 1.5 / 3 1.9 / 3 2.4 / 3 3.1 / 3 3.8 / 3.7 1.5 / 3 1.9 / 3 2.4 / 3
Simple 154 269 431 594 753 931 423 677 933
16 Multiple 175 254 347 455 578 714 399 546 715
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 2.1 / 3 2.7 / 3 3.3 / 3.2 1.5 / 3 1.5 / 3 2.1 / 3
Simple 106 187 300 451 592 733 294 471 708
18 Multiple 137 199 273 358 454 562 313 428 562
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.8 / 3 2.4 / 3 2.9 / 3 1.5 / 3 1.5 / 3 1.8 / 3
Simple 76 134 216 326 467 591 211 340 512
20 Multiple 102 160 219 288 365 453 251 344 451
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 2.1 / 3 2.7 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple 55 99 160 242 348 480 155 252 381
22 Multiple 75 131 180 236 300 372 206 282 366
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.7 / 3 2.4 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - 74 121 184 265 367 117 191 290
24 Multiple - 100 149 197 250 310 158 233 302
Min. Bearing - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 2/3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - 57 94 143 206 286 89 147 224
26 Multiple - 77 126 166 212 261 121 195 253
Min. Bearing - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.7 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 73 112 163 226 69 115 176
28 Multiple - - 99 142 180 222 95 156 214
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 58 89 130 182 54 91 140
30 Multiple - - 79 121 155 190 75 124 183
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 46 72 105 147 - 72 113
32 Multiple - - 63 98 133 164 - 100 154
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - 58 86 121 - 58 91
34 Multiple - - - 80 116 143 - 81 125
Min. Bearing - - - 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - 47 71 100 - 47 74
36 Multiple - - - 66 96 126 - 66 103
Min. Bearing - - - 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - - 58 83 - - 61
38 Multiple - - - - 80 111 - - 85
Min. Bearing - - - - 1.5 / 3 1.5 / 3 - - 1.5 / 3
Simple - - - - 48 69 - - 50
40 Multiple - - - - 67 95 - - 71
Min. Bearing - - - - 1.5 / 3 1.5 / 3 - - 1.5 / 3
• Both Architectural and Industrial appearance grade BOISE GLULAMS have the same structural • Table values assume that lateral support is provided at each support and continuously along the
grade, 24F-V4. Appearance grade does not affect the beam's load capacity. compression edge of the beam.
• Uniform PLF load values are limited by shear, moment, total load deflection limited to L/180 and live • Table values for Minimum Required Bearing Lengths are based on the allowable compression
load deflection limited to L/240. design value perpendicular to grain for the beam and the load value shown. Other design
• Live load equal to 0.75 of total load, for greater live/total applications (e.g. 50 psf snow or higher), considerations, such as a weaker support material, may warrant longer bearing lengths. Table
analyze specific application with BC CALC® software. values assume that support is provided across the full width of the beam.
• Span is measured center to center of the supports. • This table was designed to apply to a broad range of applications. It may be possible to exceed the
limitations of this table by analyzing a specific application with the BC CALC® software.
20 BOISE GLULAM™ Beams Roof Load Tables
Architectural Appearance Beams
3 /8" Roof Load Tables – 125% Non-Snow
1
• Both Architectural and Industrial appearance grade BOISE GLULAMSTM have the same structural • Table values for Minimum Required Bearing Lengths are based on the allowable compression
grade, 24F-V4. Appearance grade does not affect the beam's load capacity. design value perpendicular to grain for the beam and the load value shown. Other design
• Uniform PLF load values are limited by shear, moment, total load deflection limited to L/180 and live considerations, such as a weaker support material, may warrant longer bearing lengths. Table
load deflection limited to L/240. values assume that support is provided across the full width of the beam.
• Live load no greater than 0.75 of total load. • This table was designed to apply to a broad range of applications. It may be possible to exceed the
limitations of this table by analyzing a specific application with the BC CALC® software.
• Span is measured center to center of the supports.
• Table values assume that lateral support is provided at each support and continuously along the
compression edge of the beam.
24 BOISE GLULAM™ Beams Roof Load Tables
Industrial Appearance Headers
3 /2" and 5 1/2" Roof Load Tables – 125% Non-Snow
1
3/"
1
2 51/2"
Span Span
[ft] Type 7.5" 9" 10.5" 12" 13.5" 15" 9" 10.5" 12"
Simple 1817 2617 3450 4190 5029 5987 4113 5421 6584
6 Multiple 1399 2016 2548 3044 3589 4187 3168 4003 4784
Min. Bearing 2.4 / 3 3.5 / 3.3 4.6 / 4.2 5.5 / 5 6.6 / 5.9 7.9 / 6.9 3.5 / 3.3 4.6 / 4.2 5.5 / 5
Simple 1019 1469 2001 2615 3275 3805 2308 3144 4109
8 Multiple 784 1131 1540 2013 2427 2787 1777 2420 3164
Min. Bearing 1.8 / 3 2.6 / 3 3.5 / 3.4 4.6 / 4.4 5.8 / 5.4 6.7 / 6.2 2.6 / 3 3.5 / 3.4 4.6 / 4.4
Simple 650 937 1277 1670 2115 2612 1473 2007 2624
10 Multiple 499 721 983 1285 1627 2011 1133 1544 2019
Min. Bearing 1.5 / 3 2.1 / 3 2.8 / 3 3.7 / 3.6 4.7 / 4.5 5.8 / 5.6 2.1 / 3 2.8 / 3 3.7 / 3.6
Simple 373 649 884 1156 1465 1810 1019 1390 1817
12 Multiple 345 498 680 889 1127 1392 783 1068 1397
Min. Bearing 1.5 / 3 1.7 / 3 2.4 / 3 3.1 / 3 3.9 / 3.8 4.8 / 4.6 1.7 / 3 2.4 / 3 3.1 / 3
Simple 233 406 647 847 1073 1327 637 1017 1331
14 Multiple 252 364 497 651 825 1020 572 781 1022
Min. Bearing 1.5 / 3 1.5 / 3 2/3 2.6 / 3 3.3 / 3.2 4.1 / 4 1.5 / 3 2/3 2.6 / 3
Simple 154 269 431 646 819 1013 423 677 1015
16 Multiple 191 277 378 496 629 778 435 595 779
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 2.3 / 3 2.9 / 3 3.6 / 3.5 1.5 / 3 1.5 / 3 2.3 / 3
Simple 106 187 300 451 645 797 294 471 708
18 Multiple 142 217 297 389 494 612 341 467 612
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.8 / 3 2.6 / 3 3.2 / 3.1 1.5 / 3 1.5 / 3 1.8 / 3
Simple 76 134 216 326 467 643 211 340 512
20 Multiple 102 174 239 314 398 493 274 375 492
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 2.1 / 3 2.9 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple 55 99 160 242 348 480 155 252 381
22 Multiple 75 132 196 257 327 405 208 308 400
Min. Bearing 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.7 / 3 2.4 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - 74 121 184 265 367 117 191 290
24 Multiple - 100 162 215 273 339 158 255 330
Min. Bearing - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 2/3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - 57 94 143 206 286 89 147 224
26 Multiple - 77 126 181 231 285 121 198 277
Min. Bearing - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.7 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 73 112 163 226 69 115 176
28 Multiple - - 99 151 197 242 95 156 234
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 58 89 130 182 54 91 140
30 Multiple - - 79 121 169 208 75 124 190
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
Simple - - 46 72 105 147 - 72 113
32 Multiple - - 63 98 142 180 - 100 154
Min. Bearing - - 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - 58 86 121 - 58 91
34 Multiple - - - 80 117 157 - 81 125
Min. Bearing - - - 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - 47 71 100 - 47 74
36 Multiple - - - 66 96 135 - 66 103
Min. Bearing - - - 1.5 / 3 1.5 / 3 1.5 / 3 - 1.5 / 3 1.5 / 3
Simple - - - - 58 83 - - 61
38 Multiple - - - - 80 113 - - 85
Min. Bearing - - - - 1.5 / 3 1.5 / 3 - - 1.5 / 3
Simple - - - - 48 69 - - 50
40 Multiple - - - - 67 95 - - 71
Min. Bearing - - - - 1.5 / 3 1.5 / 3 - - 1.5 / 3
• Both Architectural and Industrial appearance grade BOISE GLULAMSTM have the same structural • Table values for Minimum Required Bearing Lengths are based on the allowable compression design
grade, 24F-V4. Appearance grade does not affect the beam's load capacity. value perpendicular to grain for the beam and the load value shown. Other design considerations,
• Uniform PLF load values are limited by shear, moment, total load deflection limited to L/180 and live such as a weaker support material, may warrant longer bearing lengths. Table values assume that
load deflection limited to L/240. support is provided across the full width of the beam.
• Live load no greater than 0.75 of total load. • This table was designed to apply to a broad range of applications. It may be possible to exceed the
limitations of this table by analyzing a specific application with the BC CALC® software.
• Span is measured center to center of the supports.
• Table values assume that lateral support is provided at each support and continuously along the
compression edge of the beam.
BOISE GLULAM™ Beams Floor & Roof Application Tables 25
GENERAL NOTES Floor Notes (see pages 25, 26, 29)
• Floor loads are 40 psf live load and 12 psf dead load. Floor live load
• Continuous lateral support at the top of the beam is assumed. has been reduced per area provisions in accordance with the model
• Minimum 3 inch end bearing or see BC CALC® software requirements. building codes.
• Bearing length specifications assume bearing across the full width of • Floor joist spans may be either simple or continuous. Mid-span
the beams and are based upon the glulam's allowable compression support of floor joists may vary up to 4'-0" from centerline of building.
perpendicular to grain value. • Deflection is limited to L/360 live load and L/240 total load, consult
• Table assumes uniform loading on worst case of simple or multiple governing building code for local provisions.
beam span applications for all tables. • Table based upon either simple or continuous floor joist spans.
• Longer bearing lengths may be required depending upon support • Tables assume a wall load of 100 plf (pages 30,33).
conditions, use BC CALC® sizing software for analysis.
• Interior floor support may vary a maximum of 4 feet from centerline
• Multiple member beams require proper connection schedules. (page 33).
• Continuous lateral support at the top of the beam and dry conditions
are assumed. Roof Notes (see pages 27, 28 & 29)
• It may be possible to exceed the limitations of this table by analyzing • Always use roof live and dead loads that meet or exceed the required
a specific application with the BC CALC® software. design loading.
• No roof load reductions have been taken.
Ridge Beam (see page 28) Header (Roof) (see pages 27 & 29)
• Deflection is limited to L/240 live load and L/180 total load.
• Deflection is limited to L/240 live load and L/180 total load.
• Table based upon either simple or continuous beam span conditions.
• Table assumes 2’-0" roof overhang.
rt
Suppo g
Spacin
Width
Beam
Width of Building Segment [feet]
Floor Load
Support KEY: Beam Breadth [in] X Beam Depth [in] End Support / Intermediate Support Bearing Length Requirements [in]
[psf]
Load Spacing
Duration % Live Dead [Feet] 24 28 32 36 40 44
3.125 x 13.5 2.4/5.8 3.125 x 15 2.7/6.8 3.125 x 16.5 3.1/7.7 3.125 x 16.5 3.5/8.7 3.125 x 18 3.9/9.6 3.125 x 18 4.3/10.6
12
5.125 x 10.5 1.5/3.6 5.125 x 12 1.7/4.1 5.125 x 12 1.9/4.7 5.125 x 13.5 2.2/5.3 5.125 x 13.5 2.4/5.9 5.125 x 15 2.6/6.5
3.125 x 16.5 2.7/6.8 3.125 x 18 3.2/7.9 3.125 x 18 3.6/9.0 5.125 x 15 2.5/6.2 5.125 x 16.5 2.8/6.9 5.125 x 16.5 3.1/7.6
14
5.125 x 13.5 1.7/4.1 5.125 x 13.5 2.0/4.8 5.125 x 15 2.2/5.5 6.75 x 13.5 1.9/4.7 6.75 x 13.5 2.1/5.2 6.75 x 15 2.3/5.8
3.5 x 18 3.1/7.7 5.125 x 15 2.2/5.5 5.125 x 16.5 2.5/6.3 5.125 x 16.5 2.9/7.1 5.125 x 18 3.2/7.9 5.125 x 18 3.5/8.6
16
5.125 x 15 1.9/4.7 6.75 x 13.5 1.7/4.2 6.75 x 15 1.9/4.8 6.75 x 15 2.2/5.5 6.75 x 15 2.4/6.0 6.75 x 16.5 2.7/6.6
5.125 x 16.5 2.2/5.3 5.125 x 18 2.5/6.2 5.125 x 18 2.9/7.1 5.125 x 19.5 3.2/8.0 5.125 x 19.5 3.6/8.8 5.125 x 21 3.9/9.7
100% 40 12 18
6.75 x 15 1.6/4.0 6.75 x 15 1.9/4.7 6.75 x 16.5 2.2/5.4 6.75 x 16.5 2.4/6.0 6.75 x 18 2.7/6.7 6.75 x 18 3.0/7.4
5.125 x 18 2.3/5.8 5.125 x 19.5 2.8/6.9 5.125 x 19.5 3.2/7.9 5.125 x 21 3.6/8.8 5.125 x 21 4.0/9.8 5.125 x 22.5 4.8/11.9
20
6.75 x 16.5 1.8/4.5 6.75 x 16.5 2.1/5.2 6.75 x 18 2.4/6.0 6.75 x 18 2.7/6.7 6.75 x 19.5 3.0/7.5 6.75 x 19.5 3.3/8.2
5.125 x 19.5 2.6/6.3 5.125 x 21 3.1/7.6 5.125 x 22.5 3.5/8.6 5.125 x 22.5 3.9/9.7 5.125 x 24 4.3/10.8 6.75 x 22.5 3.6/9.0
22
6.75 x 18 2.0/4.9 6.75 x 18 2.3/5.8 6.75 x 19.5 2.7/6.6 6.75 x 21 3.0/7.4 6.75 x 21 3.3/8.2
5.125 x 21 2.8/6.9 5.125 x 22.5 3.3/8.2 5.125 x 24 3.8/9.4 6.75 x 22.5 3.2/8 6.75 x 22.5 3.6/8.9 6.75 x 24 4.0/9.8
24
6.75 x 19.5 2.2/5.4 6.75 x 19.5 2.5/6.3 6.75 x 21 2.9/7.2
26 BOISE GLULAM™ Beams Floor & Roof Application Tables
rt
Suppo g
S p a c in
Width
Beam
Width of Building Segment [feet]
Floor Load
Support KEY: Beam Breadth [in] X Beam Depth [in] End Support / Intermediate Support Bearing Length Requirements [in]
[psf]
Load Spacing
Duration % Live Dead [Feet] 24 28 32 36 40 44
3.125 x 10.5 2.1/ 5.2 3.125 x 12 2.5 / 6.2 3.125 x 12 2.9 / 7.1 3.125 x 13.5 3.2 / 7.9 3.125 x 15 3.5 / 8.7 3.125 x 15 3.8 / 9.5
6
5.125 x 9 1.5 / 3.2 5.125 x 9 1.5 / 3.8 5.125 x 9 1.8 / 4.3 5.125 x 10.5 2.0 / 4.8 5.125 x 10.5 2.2 / 5.3 5.125 x 10.5 2.4 / 5.8
3.125 x 13.5 2.8 / 6.9 3.125 x 15 3.2 / 8 3.125 x 15 3.7 / 9.1 3.125 x 16.5 4.1 / 10.1 3.125 x 18 4.5 / 11.1 5.125 x 13.5 3.0 / 7.3
8
5.125 x 10.5 1.7 / 4.2 5.125 x 12 2.0 / 4.9 5.125 x12 2.3 / 5.6 5.125 x 12 2.5 / 6.2 5.125 x 13.5 2.7 / 6.8 6.75 x 12 2.3 / 5.6
3.125 x 16.5 3.4 / 8.4 3.125 x 16.5 3.9 / 9.7 5.125 x 15 2.7 / 6.7 5.125 x 15 3.0 / 7.4 5.125 x 16.5 3.3 / 8.1 5.125 x 16.5 3.5 / 8.7
10
5.125 x 12 2.1 / 5.2 5.125 x 13.5 2.4 / 6 6.75 x 12 2.1 / 5.1 6.75 x 13.5 2.3 / 5.6 6.75 x 13.5 2.5 / 6.1 6.75 x 15 2.7 / 6.6
5.125 x 15 2.4 / 6 5.125 x 16.5 2.8 / 6.9 5.125 x 16.5 3.1 / 7.8 5.125 x 18 3.4 / 8.5 5.125 x 18 3.7 / 9.2 5.125 x 19.5 4.0 / 9.8
100% 40 12 12
6.75 x 13.5 1.9 / 4.6 6.75 x 13.5 2.1 / 5.3 6.75 x 15 2.4 / 5.9 6.75 x 15 2.6 / 6.5 6.75 x 16.5 2.8 / 7 6.75 x 16.5 3.0 / 7.5
5.125 x 16.5 2.8 / 6.9 5.125 x 18 3.2 / 7.8 5.125 x 19.5 3.5 / 8.7 5.125 x 19.5 3.8 / 9.5 5.125 x 21 4.1 / 10.2 5.125 x 21 4.3 / 10.8
14
6.75 x 15 2.1 / 5.2 6.75 x 16.5 2.4 / 6 6.75 x 16.5 2.7 / 6.6 6.75 x 18 2.9 / 7.2 6.75 x 18 3.1 / 7.7 6.75 x 19.5 3.3 / 8.2
5.125 x 19.5 3.1 / 7.6 5.125 x 21 3.5 / 8.7 5.125 x 21 3.9 / 9.6 5.125 x 22.5 4.2 / 10.4 5.125 x 22.5 4.4 / 11 5.125 x 24 4.7 / 11.6
16
6.75 x 16.5 2.4 / 5.8 6.75 x 18 2.7 / 6.6 6.75 x 19.5 2.9 / 7.3 6.75 x 19.5 3.2 / 7.9 6.75 x 21 3.4 / 8.4 6.75 x 21 3.5 / 8.8
5.125 x 21 3.4 / 8.4 5.125 x 22.5 3.8 / 9.4 5.125 x 24 4.2 / 10.3 5.125 x 24 4.5 / 11.1 6.75 x 22.5 3.6 / 8.9 6.75 x 24 3.9 / 9.8
18
6.75 x 19.5 2.6 / 6.4 6.75 x 19.5 2.9 / 7.2 6.75 x 21 3.2 / 7.9 6.75 x 22.5 3.4 / 8.4
Rough
g
Width Openin
Width
Clear Span [feet]
Roof Load
of Bldg KEY: Beam Breadth [in] X Beam Depth [in] End Support Length Requirements [in]
[psf]
Load Segment
Duration % Live Dead [Feet] 8'-3" 9'-3" 10'-0" 12'-0" 16'-3" 18'-3"
3.125 x 6 1.5 3.125 x 7.5 1.5 3.125 x 7.5 1.5 3.125 x 9 1.5 3.125 x 12 2.0 3.125 x 13.5 2.3
24
5.125 x 6 1.5 5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 10.5 1.5 5.125 x 12 1.5
3.125 x 7.5 1.5 3.125 x 7.5 1.5 3.125 x 9 1.5 3.125 x 10.5 1.8 3.125 x 13.5 2.4 3.125 x 15 2.7
125 20 15 30
5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 12 1.5 5.125 x 12 1.7
3.125 x 7.5 1.5 3.125 x 9 1.7 3.125 x 9 1.8 3.125 x 10.5 2.1 3.125 x 15 2.9 3.125 x 16.5 3.2
36
5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 12 1.8 5.125 x 13.5 2.0
3.125 x 7.5 1.5 3.125 x 7.5 1.5 3.125 x 9 1.5 3.125 x 10.5 1.7 3.125 x 13.5 2.3 3.125 x 15 2.6
24
5.125 x 6 1.5 5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 10.5 1.5 5.125 x 12 1.6
3.125 x 7.5 1.5 3.125 x 9 1.6 3.125 x 9 1.7 3.125 x 10.5 2.1 3.125 x 15 2.8 3.125 x 16.5 3.1
115 25 15 30
5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 12 1.7 5.125 x 13.5 1.9
3.125 x 7.5 1.7 3.125 x 9 1.9 3.125 x 10.5 2.0 3.125 x 12 2.4 3.125 x 16.5 3.3 3.125 x 18 3.7
36
5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 12 2.0 5.125 x 13.5 2.3
3.125 x 7.5 1.5 3.125 x 9 1.5 3.125 x 9 1.6 3.125 x 10.5 1.9 3.125 x 13.5 2.6 3.125 x 16.5 2.9
24
5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 12 1.6 5.125 x 13.5 1.8
3.125 x 9 1.6 3.125 x 9 1.8 3.125 x 10.5 2.0 3.125 x 12 2.3 3.125 x 15 3.1 3.125 x 18 3.5
115 30 15 30
5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 12 1.9 5.125 x 13.5 2.2
3.125 x 9 1.9 3.125 x 10.5 2.1 3.125 x 10.5 2.3 3.125 x 12 2.7 3.125 x 16.5 3.7 3.125 x 18 4.1
36
5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 10.5 1.7 5.125 x 13.5 2.3 5.125 x 15 2.5
3.125 x 9 1.6 3.125 x 9 1.8 3.125 x 10.5 2.0 3.125 x 12 2.3 3.125 x 15 3.2 3.125 x 18 3.5
24
5.125 x 6 1.5 5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 12 1.9 5.125 x 13.5 2.2
3.125 x 9 2.0 3.125 x 10.5 2.2 3.125 x 10.5 2.4 3.125 x 13.5 2.8 3.125 x 16.5 3.8 5.125 x 15 4.3
115 40 15 30
5.125 x 7.5 1.5 5.125 x 7.5 1.5 5.125 x 9 1.5 5.125 x 10.5 1.8 5.125 x 13.5 2.3 6.75 x 13.5 2.0
3.125 x 9 2.3 3.125 x 10.5 2.6 3.125 x 12 2.8 3.125 x 13.5 3.3 3.125 x 18 4.5 5.125 x 16.5 5.0
36
5.125 x 7.5 1.5 5.125 x 9 1.6 5.125 x 9 1.7 5.125 x 10.5 2.1 5.125 x 15 2.8 6.75 x 15 2.4
g
acin
ort Sp
S upp
Width
Width
Ridge Beam Support Spacing [feet]
Roof Load
[psf] of Bldg KEY: Beam Breadth [in] X Beam Depth [in] End Support/Intermediate Support Bearing Length Requirements [in]
Load Segment
Duration % Live Dead [Feet] 12 16 20 24
3.125 x 10.5 1.5/ 3.8 3.125 x 13.5 2.0 / 5 3.125 x 16.5 2.5 / 6.2 5.125 x 16.5 1.8 / 4.5
24
5.125 x 9 1.5 / 3 5.125 x 10.5 1.5 / 3.1 5.125 x 13.5 1.6 / 3.8 6.75 x 15 1.5 / 3.5
3.125 x 12 1.9 / 4.7 3.125 x 15 2.5 / 6.2 3.125 x 18 3.1 / 7.8 5.125 x 18 2.3 / 5.7
125 20 15 30
5.125 x 9 1.5 / 3 5.125 x 12 1.6 / 3.8 5.125 x 15 1.9 / 4.7 6.75 x 16.5 1.8 / 4.3
3.125 x 12 2.3 / 5.6 3.125 x 16.5 3.0 / 7.5 5.125 x 16.5 2.3 / 5.7 5.125 x 19.5 2.7 / 6.8
36
5.125 x 10.5 1.5 / 3.5 5.125 x 13.5 1.9 / 4.6 6.75 x 15 1.8 / 4.3 6.75 x 18 2.1 / 5.2
3.125 x 12 1.7 / 4.2 3.125 x 15 2.3 / 5.6 3.125 x 18 2.8 / 7 5.125 x 18 2.1 / 5.1
24
5.125 x 9 1.5 / 3 5.125 x 12 1.5 / 3.4 5.125 x 15 1.7 / 4.3 6.75 x 16.5 1.6 / 3.9
3.125 x 12 2.1 / 5.3 3.125 x 16.5 2.8 / 7 5.125 x 16.5 2.2 / 5.3 5.125 x 19.5 2.6 / 6.4
115 25 15 30
5.125 x 10.5 1.5 / 3.2 5.125 x 13.5 1.7 / 4.3 6.75 x 15 1.6 / 4 6.75 x 18 2 / 4.8
3.125 x 13.5 2.6 / 6.3 3.125 x 18 3.4 / 8.4 5.125 x 18 2.6 / 6.4 5.125 x 22.5 3.1 / 7.6
36
5.125 x 10.5 1.6 / 3.9 5.125 x 15 2.1 / 5.1 6.75 x 16.5 2 / 4.8 6.75 x 19.5 2.3 / 5.8
3.125 x 12 1.9 / 4.7 3.125 x 15 2.5 / 6.2 5.125 x 15 1.9 / 4.7 5.125 x 19.5 2.3 / 5.6
24
5.125 x 10.5 1.5 / 3 5.125 x 12 1.5 / 3.8 6.75 x 13.5 1.5 / 3.6 6.75 x 16.5 1.7 / 4.3
3.125 x 13.5 2.4 / 5.8 3.125 x 18 3.1 / 7.7 5.125 x 18 2.4 / 5.9 5.125 x 21 2.8 / 7
115 30 15 30
5.125 x 10.5 1.5 / 3.6 5.125 x 13.5 1.9 / 4.7 6.75 x 15 1.8 / 4.5 6.75 x 18 2.2 / 5.4
3.125 x 15 2.8 / 7 5.125 x 15 2.3 / 5.7 5.125 x 19.5 2.9 / 7.1 5.125 x 22.5 3.4 / 8.4
36
5.125 x 12 1.7 / 4.3 6.75 x 13.5 1.8 / 4.3 6.75 x 16.5 2.2 / 5.4 6.75 x 21 2.6 / 6.4
3.125 x 13.5 2.3 / 5.6 3.125 x 16.5 3.0 / 7.4 5.125 x 16.5 2.3 / 5.6 5.125 x 21 2.7 / 6.7
24
5.125 x 10.5 1.5 / 3.4 5.125 x 13.5 1.8 / 4.5 6.75 x 15 1.7 / 4.3 6.75 x 18 2.1 / 5.1
3.125 x 15 2.8 / 7 5.125 x 15 2.3 / 5.6 5.125 x 19.5 2.8 / 7 5.125 x 22.5 3.4 / 8.4
115 40 15 30
5.125 x 12 1.7 / 4.3 6.75 x 13.5 1.8 / 4.3 6.75 x 16.5 2.2 / 5.3 6.75 x 21 2.6 / 6.4
3.125 x 16.5 3.4 / 8.4 5.125 x 16.5 2.7 / 6.8 5.125 x 21 3.4 / 8.4 6.75 x 22.5 3.1 / 7.7
36
5.125 x 12 2.1 / 5.1 6.75 x 15 2.1 / 5.2 6.75 x 18 2.6 / 6.4
OR
Rough Rough
g g
20' or 24' Span Openin Width of Span (See Table Below) Openin
*Assumes no intermediate support of floor joists Interior floor support may vary a minimum of 4 feet from centerline.
Width
Clear Span [feet]
Roof Load
[psf] of Bldg KEY: Beam Breadth [in] X Beam Depth [in] End Support Length Requirements [in]
Load Segment
Duration % Live Dead [Feet] 6'-3" 9'-3" 12'-3"
3.125 x 7.5 1.8 3.125 x 12 2.4 3.125 x 16.5 3.1
24
5.125 x 6 1.5 5.125 x 10.5 1.5 5.125 x 13.5 1.9
BOISE GLULAMTM —
Steel W Shape Substitution Table
Floor Beam Applications (100%) Duration for BOISE GLULAMTM
24F-V4 BOISE GLULAMTM Equivalent Member
Span [ft] W 6x9 W 8x10 W 12x14 W 12x16 W 12x19 W 10x 22 W 12x22 W 14x22 W 12x26 W 14x26 W16x26 W 12x30
3.125 x 10.5 3.125 x 13.5 3.125 x 18
10
5.125 x 9 5.125 x 10.5 5.125 x 13.5 5.125 x 15 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 19.5 5.125 x 21 5.125 x 22.5 5.125 x 24 5.125 x 24
3.125 x 10.5 3.125 x 13.5 3.125 x 18
12
5.125 x 9 5.125 x 10.5 5.125 x 13.5 5.125 x 15 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 22.5
3.125 x 10.5 3.125 x 13.5 3.125 x 18
14
5.125 x 9 5.125 x 10.5 5.125 x 13.5 5.125 x 15 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 22.5
3.125 x 10.5 3.125 x 13.5 3.125 x 18
16
5.125 x 9 5.125 x 10.5 5.125 x 15 5.125 x 15 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 22.5
3.125 x 10.5 3.125 x 13.5 3.125 x 18
18
5.125 x 9 5.125 x 10.5 5.125 x 15 5.125 x 16.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 22.5
3.125 x 10.5 3.125 x 13.5 3.125 x 18
20
5.125 x 9 5.125 x 10.5 5.125 x 15 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 18 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 22.5
3.125 x 10.5 3.125 x 13.5 3.125 x 18
22
5.125 x 9 5.125 x 10.5 5.125 x 15 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 22.5
3.125 x 10.5 3.125 x 13.5 3.125 x 18
24
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
26
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
28
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
30
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
32
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
34
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
36
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 22.5 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
38
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 24 5.125 x 21
3.125 x 10.5 3.125 x 13.5 3.125 x 18
40
5.125 x 9 5.125 x 10.5 5.125 x 16.5 5.125 x 16.5 5.125 x 18 5.125 x 16.5 5.125 x 19.5 5.125 x 21 5.125 x 21 5.125 x 21 5.125 x 24 5.125 x 21
NOTES
• Table intended for preliminary design only. Substitutions • Deflection limited to L/360 for live load, based upon a
should always be approved by the project's design live load/total load ratio of 0.8 (residential floor loading
professional of record. 40/10 psf).
• Table assumes that original steel W section was sized • Italicized beams are non-stocked products.
properly, loading should always be verified. • Steel W Section Allowable Design Values: Fb = 0.66 x 36 ksi,
• Table was developed by comparing allowable uniform load Fv = 0.4 x 36 ksi, MOE = 29 x 106 ksi.
capacities due to the worst case control of bending, shear
• Steel Information - W Section Nomenclature: 1st number =
and deflection limits for simple span applications. Beam
approximate depth [in], 2nd number = weight per foot [lb/ft] .
weights are considered.
BOISE GLULAM™ Beams Substitution Tables 31
BOISE GLULAMTM —
Douglas Fir-Larch Solid Sawn Substitution Table
Floor Beam Applications (100%) Duration for BOISE GLULAMTM
24F-V4 BOISE GLULAMTM Equivalent Member
4x6 Doug Fir-Larch 4x8 Doug Fir-Larch 4x10 Doug Fir-Larch 4x12 Doug Fir-Larch 6x8 Doug Fir-Larch 6x10 Doug Fir-Larch 6x12 Doug Fir-Larch
Span [ft] Select Select Select Select Select Select Select
No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1
Structure Structure Structure Structure Structure Structure Structure
3.125 x 6 3.125 x 6 3.125 x 7.5 3.125 x 7.5 3.125 x 9 3.125 x 9 3.125 x 9 3.125 x 9 3.125 x 9 3.125 x 9 3.125 x 10.5 3.125 x 10.5 3.125 x 10.5 3.125 x 10.5
10
5.125 x 7.5 5.125 x 7.5 5.125 x 9 5.125 x 9 5.125 x 9 5.125 x 9
3.125 x 6 3.125 x 6 3.125 x 9 3.125 x 7.5 3.125 x 10.5 3.125 x 9 3.125 x 10.5 3.125 x 10.5 3.125 x 9 3.125 x 9 3.125 x 10.5 3.125 x 10.5 3.125 x 12 3.125 x 12
12
5.125 x 7.5 5.125 x 7.5 5.125 x 9 5.125 x 9 5.125 x 10.5 5.125 x 10.5
3.125 x 6 3.125 x 6 3.125 x 9 3.125 x 7.5 3.125 x 10.5 3.125 x 9 3.125 x 12 3.125 x 10.5 3.125 x 9 3.125 x 9 3.125 x 12 3.125 x 10.5 3.125 x 13.5 3.125 x 12
14
5.125 x 7.5 5.125 x 7.5 5.125 x 10.5 5.125 x 9 5.125 x 10.5 5.125 x 10.5
3.125 x 6 3.125 x 6 3.125 x 9 3.125 x 7.5 3.125 x 10.5 3.125 x 9 3.125 x 12 3.125 x 10.5 3.125 x 9 3.125 x 9 3.125 x 12 3.125 x 12 3.125 x 13.5 3.125 x 13.5
16
5.125 x 7.5 5.125 x 7.5 5.125 x 10.5 5.125 x 10.5 5.125 x 12 5.125 x 12
3.125 x 6 3.125 x 6 3.125 x 9 3.125 x 7.5 3.125 x 10.5 3.125 x 10.5 3.125 x 12 3.125 x 10.5 3.125 x 9 3.125 x 9 3.125 x 12 3.125 x 12 3.125 x 13.5 3.125 x 13.5
18
5.125 x 7.5 5.125 x 7.5 5.125 x 10.5 5.125 x 10.5 5.125 x 12 5.125 x 12
3.125 x 6 3.125 x 6 3.125 x 9 3.125 x 7.5 3.125 x 10.5 3.125 x 10.5 3.125 x 12 3.125 x 12 3.125 x 9 3.125 x 9 3.125 x 12 3.125 x 12 3.125 x 13.5 3.125 x 13.5
20
5.125 x 7.5 5.125 x 7.5 5.125 x 10.5 5.125 x 10.5 5.125 x 12 5.125 x 12
3.125 x 6 3.125 x 6 3.125 x 9 3.125 x 7.5 3.125 x 10.5 3.125 x 10.5 3.125 x 12 3.125 x 12 3.125 x 9 3.125 x 9 3.125 x 12 3.125 x 12 3.125 x 13.5 3.125 x 13.5
22
5.125 x 7.5 5.125 x 7.5 5.125 x 10.5 5.125 x 10.5 5.125 x 12 5.125 x 12
3.125 x 6 3.125 x 6 3.125 x 9 3.125 x 7.5 3.125 x 10.5 3.125 x 10.5 3.125 x 12 3.125 x 12 3.125 x 9 3.125 x 9 3.125 x 10.5 3.125 x 10.5 3.125 x 13.5 3.125 x 13.5
24
5.125 x 7.5 5.125 x 7.5 5.125 x 10.5 5.125 x 10.5 5.125 x 12 5.125 x 12
NOTES
• Table intended for preliminary design only. Substitutions • Deflection limited to L/360 for live load, based upon a live
should always be approved by the project's design load/total load ratio of 0.8 (residential floor loading 40/10 psf).
professional of record.
• Douglas Fir-Larch solid sawn design values per 1997
• Table assumes that original solid sawn beam was sized National Design Specification (NDS) for Wood Construction.
properly, loading should always be verified.
• Table was developed by comparing allowable uniform load
capacities due to the worst case control of bending, shear
and deflection limits for simple span applications.
32 BOISE GLULAM™ Beams Hanger Tables
EG GLT HGLT
HU HGUS LEG/MEG WP
BOISE GLULAM™ Beams Hanger Tables 33
GHF HD KEG
RECOMMENDED HARDWARE
• Current Pentium Processor
• 1GB RAM
• Microsoft® Intellimouse
• Windows® 2000 Professional or
Windows XP Professional
Improvements in capacity or speed
of these components will yield
better performance.
For information about Boise's engineered wood products,
including sales terms and conditions, warranties and disclaimers,
visit our website at
www.BC.com/EWP
Boise, the Boise Logo, BC CALC , BOISE GLULAMTM are trademarks of Boise Building Solutions, Manufacturing, LLC
WEBGLUSPEC 6/2005