You are on page 1of 180

PROTECTION,

SECURITY AND
SECTIONING FOR
ALL YOUR CIRCUITS

General catalogue
2023 - 2024
Protection, security and sectioning for
all your circuits.
Established in 2018, FMF ELECTRIC is known as the future leading brand of
low voltage products throughout South America.

Already present in Argentina, Uruguay, Bolivia, Paraguay, Chile, Perú


and Colombia, FMF ELECTRIC produces not only outstanding products,
but also provides a high-qualified technical service supported by a
leading marketing and product development policy aimed at
providing effective solutions to the electricity market in general.

Our factory is located in China, it occupies more than Auto


Au toma
to mati
maticc te
ti test
stin
sting
ing
82.000m2 and employs more than 2,500 people, and
produces and exports a wide assortment of low-voltage
electrical products including MCB, RCCB, Contactors,
Motor Protectors, DOL, Pushbuttons, LED Indicators
and SPD, among many others.

All of our production procedures are carried out


strictly in compliance with the ISO 9001, ISO
14001 and OHSAS18001 standards. Many of our
products are also TÜV and Intertek certified.
Asse
As semb
sembly
mb ly llin
ines
in es
It is important to remark that besides
manufacturing our current products, in
FMF Electric we are constantly listening
to our customers and the market in
order to develop and provide the
best possible solutions.

Protection, safety and sectioning


for all your circuits.

GENERAL INDEX
Breakers ................................................................... pg. 3
Contactors ........................................................... pg. 35
Protection ............................................................ pg. 55
Distribution......................................................... pg. 75
Climate Control................................................. pg. 99
Signaling, Control & Switch .................... pg. 117
Residential Safety ......................................... pg. 129
Breakers

Breakers Sub-Index
D23 - Electro-magnetic Residual Current Breaker ......................... 4
T18 - Mini Circuit Breaker 4kA ............................................................. 5
T18H - Mini Circuit Breaker - High Power 10kA 947-2.................... 6
T19 - Mini Cirtuit Breaker & Auxiliaries 6kA .................................... 7
T19H - Mini Circuit Breaker 10kA ........................................................... 8
T19DC - Mini Circuit Breaker...................................................................... 9
T20 - Mini Circuit Breaker 10kA 898-1 .............................................. 11
T20DC - Mini Circuit Breaker ....................................................................13
T10 - Thermo-magnetic double adjustable MCCB ......................19
T11 - Thermo-magnetic Fixed MCCB - High power....................21
T1 - Air Circuit Breaker.......................................................................24
Characteristics ...............................................................................................32
D23
Electro-magnetic Residual Current Circuit Breaker

Standard: IEC 61008-1

Technical Data
Electrical Features
Ϸ Type (wave form of the earth leakage sensed): AC, A, AC~S, A~S
Ϸ Rated current In: 25, 32, 40, 50, 63A
Ϸ Poles: 2P (1P+N), 4P (3P+N)
Ϸ Rated voltage Ue: 240/415V
Ϸ Rated sensitivity I©n: 0.03, 0.1, 0.3A
Ϸ Insulation voltage Ui: 500V
Ϸ Rated residual making and breaking capacity I©m: 500A (In=25A/40A)
630A (In=50A/63A)
Ϸ Short-circuit current Inc=I©c: 6,000A
Ϸ SCPD fuse:
Ϸ Break time under I©n: •0.1s
Ϸ Rated frequency: 50/60Hz
Ϸ Rated impulse withstand voltage (1.2/50) Uimp: 4.000V
Ϸ Dielectric TEST voltage at ind. Freq. for 1 min: 2.5kV
Ϸ Pollution degree: 2

Mechanical Features
Ϸ Electrical life: 2.000 Cycles
Ϸ Mechanichal life: 4.000 Cycles
Ϸ Fault current indicator: YES
Ϸ Protecction degree: IP20
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Cable/ U-pin busbar/ Pin-type busbar
Ϸ Terminal size top / bottom for cable: 25mm2 18-3AWG
Ϸ Terminal size top / bottom for busbar: 25mm2 18-3AWG
Ϸ Tightening torque: 2.5 Nm 18In-lbs
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: From top and bottom

Overall and Installation Dimension (mm)

4
www.fmfelectric.com
T18
Mini Circuit Breaker

Standard: IEC 60898-1

Technical Data
Electrical Features
Ϸ Rated Current In: 6, 10, 16, 20, 25, 32, 40, 50, 63A
Ϸ Poles: 1P, 2P (1P+N) / 2P, 3P, 4P (3P+N) / 4P
Ϸ Rated voltage Ue: 240/415V~
Ϸ Insulation voltage Ui: 500V
Ϸ Rated frecuency: 50/60Hz
Ϸ Rated breaking capacity: 4.000A
Ϸ Energy limiting class: 3
Ϸ Rated impulse withstand voltage (1.2/50) Uimp: 4.000V
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Pollution degree: 2
Ϸ Thermo-magnetic release characteristic: B, C & D

Mechanical Features
Ϸ Electrical life: 4.000 Cycles
Ϸ Mechanichal life: 10.000 Cycles
Ϸ Contact position indicator: NO
Ϸ Protecction degree: IP20
Ϸ Reference temperature for setting of thermal element: 30 °C
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: TCable / Pin-type busbar
Ϸ Terminal size top / bottom for cable: 25mm2
Ϸ Terminal size top / bottom for busbar: 25mm2
Ϸ Tightening torque: 2.0 Nm
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: From top and bottom

Combination with accesories


Ϸ Auxiliary contact: YES
Ϸ Alarm contact: YES
Ϸ Shunt release: YES
Ϸ Over / under voltage release: YES

Overall and Installation Dimension (mm)

5
www.fmfelectric.com
T18H
Mini Circuit Breaker - High Power

Standard: IEC 60947-2

Technical Data
Electrical Features
Ϸ Rated Current In: 63, 80, 100, 125A
Ϸ Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P
Ϸ Rated voltage Ue: 240/415V~
Ϸ Insulation voltage Ui: 500V
Ϸ Rated frecuency: 50/60Hz
Ϸ Rated short-circuit breaking capacity: 10.000A
Ϸ Energy limiting class: 3
Ϸ Rated impulse withstand voltage (1.2/50) Uimp: 4.000V
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Pollution degree: 2
Ϸ Thermo-magnetic release characteristic: C&D

Mechanical Features
Ϸ Electrical life: 4.000 Cycles
Ϸ Mechanichal life: 10.000 Cycles
Ϸ Contact position indicator: YES
Ϸ Protecction degree: IP20
Ϸ Reference temperature for setting of thermal element: 30 °C
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Pin-type busbar
Ϸ Terminal size top / bottom for cable: 50mm2
Ϸ Terminal size top / bottom for busbar: 50mm2
Ϸ Tightening torque: 2.5 Nm
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: From top and bottom

Combination with accesories


Ϸ Auxiliary contact: YES
Ϸ Alarm contact: YES
Ϸ Shunt release: YES
Ϸ Over / under voltage release: YES

Overall and Installation Dimension (mm)

6
www.fmfelectric.com
T19
Mini Circuit Breacker

Standard: IEC 60898-1

Technical Data
Electrical Features
Ϸ Rated Current In: 6, 10, 16, 20, 25, 32, 40, 50, 63A
Ϸ Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P
Ϸ Rated voltage Ue: 240/415V~
Ϸ Insulation voltage Ui: 500V
Ϸ Rated frecuency: 50/60Hz
Ϸ Rated breaking capacity: 6.000A
Ϸ Energy limiting class: 3
Ϸ Rated impulse withstand voltage (1.2/50) Uimp: 4.000V
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Pollution degree: 2
Ϸ Thermo-magnetic release characteristic: B, C & D

Mechanical Features
Ϸ Electrical life: 8.000 Cycles
Ϸ Mechanichal life: 20.000 Cycles
Ϸ Contact position indicator: YES
Ϸ Protecction degree: IP20
Ϸ Reference temperature for setting of thermal element: 30 °C
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Cable / Pin-type busbar
Ϸ Terminal size top / bottom for cable: 25mm2 18-3AWG
Ϸ Terminal size top / bottom for busbar: 25mm2 18-3AWG
Ϸ Tightening torque: 2.0 Nm
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: From top and bottom

Combination with accesories


Ϸ Auxiliary contact: YES
Ϸ Alarm contact: YES
Ϸ Shunt release: YES
Ϸ Over / under voltage release: YES

Overall and Installation Dimension (mm)

7
www.fmfelectric.com
T19H
Mini Circuit Breacker - High power

Standard: IEC 60947-2

Technical Data
Electrical Features
Ϸ Rated Current In: 6, 10, 16, 20, 25, 32, 40, 50, 63A
Ϸ Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P
Ϸ Rated voltage Ue: 240/415V~
Ϸ Insulation voltage Ui: 500V
Ϸ Rated frecuency: 50/60Hz
Ϸ Rated short-breaking capacity: 10.000A
Ϸ Energy limiting class: 3
Ϸ Rated impulse withstand voltage (1.2/50) Uimp: 4.000V
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Pollution degree: 2
Ϸ Thermo-magnetic release characteristic: B, C & D

Mechanical Features
Ϸ Electrical life: 8.000 Cycles
Ϸ Mechanichal life: 20.000 Cycles
Ϸ Contact position indicator: YES
Ϸ Protecction degree: IP20
Ϸ Reference temperature for setting of thermal element: 30 °C
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Cable / Pin-type busbar
Ϸ Terminal size top / bottom for cable: 25mm2 18-3AWG
Ϸ Terminal size top / bottom for busbar: 25mm2 18-3AWG
Ϸ Tightening torque: 2.0 Nm
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: From top and bottom

Combination with accesories


Ϸ Auxiliary contact: YES
Ϸ Alarm contact: YES
Ϸ Shunt release: YES
Ϸ Over / under voltage release: YES

Overall and Installation Dimension (mm)

8
www.fmfelectric.com
T19DC
Mini Circuit Breacker - DC

Standard: IEC 60947-2

Technical Data
Electrical Features
Ϸ Rated Current In: 1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A
Ϸ Poles: 1P, 2P, 4P
Ϸ Rated voltage Ue: 1P(250VDC), 2P(500VDC), 4P(1000VDC)
Ϸ Rated breaking capacity: 6.000A
Ϸ Rated impulse withstand voltage (1.5/50) Uimp: 4.000V
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Pollution degree: 2
Ϸ Thermo-magnetic release characteristic: C (7~10)In

Mechanical Features
Ϸ Electrical life: 4.000 Cycles
Ϸ Mechanichal life: 10.000 Cycles
Ϸ Contact position indicator: YES
Ϸ Protecction degree: IP20
Ϸ Reference temperature for setting of thermal element: 30 °C
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Cable / Pin-type busbar / U-type busbar
Ϸ Terminal size top / bottom for cable: 25mm2 18-3AWG
Ϸ Terminal size top / bottom for busbar: 25mm2 18-3AWG
Ϸ Tightening torque: 2.5 Nm 22In-lbs
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: According to the wiring diagram

Combination with accesories


Ϸ Auxiliary contact: YES
Ϸ Alarm contact: YES
Ϸ Shunt release: YES
Ϸ Over / under voltage release: YES

Overall and Installation Dimension (mm)

9
www.fmfelectric.com
Auxiliary Contact for T19
Alarm Auxiliary Contact for T19

Standard: IEC 60947-5

Technical Data
Electrical Features
Ϸ Rated value: AC415/400V 50/60 Hz 3A
AC240/400V 50/60Hz 3A
DC130V 1A
DC48V 2A
DC24V 6A
Ϸ Configuration: 01T19AUXCO
Ϸ Rated impulse withstand voltage (1.2/50) Uimp: 4.000V
Ϸ Rated short circuit making capacity: 20Ie, t=0.1s
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Insullation voltage Ui: 500V
Ϸ Pollution degree: 2

Mechanical Features
Ϸ Electrical life: 6.000 Cycles
Ϸ Mechanichal life: 10.000 Cycles
Ϸ Protecction degree: IP20
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Cable
Ϸ Terminal size top / bottom for cable: 25mm2 18-13AWG
Ϸ Tightening torque: 0.8 Nm 7In-lbs

Overall and Installation Dimension (mm)

10
www.fmfelectric.com
T20
Mini Circuit Breaker - High Power

Standard: IEC 60898-1

Technical Data
Electrical Features
Ϸ Rated Current In: 6, 10, 16, 20, 25, 32, 40, 50, 63A
Ϸ Poles: 1P, 2P (1P+N) / 2P, 3P, 4P (3P+N) / 4P
Ϸ Rated voltage Ue: 240/415V~
Ϸ Insulation voltage Ui: 500V
Ϸ Rated frecuency: 50/60Hz
Ϸ Rated breaking capacity: 10.000A
Ϸ Energy limiting class: 3
Ϸ Rated impulse withstand voltage (1.2/50) Uimp: 4.000V
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Pollution degree: 2
Ϸ Thermo-magnetic release characteristic: B, C y D

Mechanical Features
Ϸ Electrical life: 8.000 Cycles
Ϸ Mechanichal life: 20.000 Cycles
Ϸ Contact position indicator: YES
Ϸ Protecction degree: IP20
Ϸ Reference temperature for setting of thermal element: 30 °C
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Cable / Pin-type busbar / U-type busbar
Ϸ Terminal size top / bottom for cable: 25mm2 18-3AWG
Ϸ Terminal size top / bottom for busbar: 25mm2 18-3AWG
Ϸ Tightening torque: 2.5 Nm 22in-lbs
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: From top and bottom.

Combination with accesories


Ϸ Auxiliary contact: YES
Ϸ Alarm contact: YES
Ϸ Shunt release: YES
Ϸ Over / under voltage release: YES

Overall and Installation Dimension (mm)

11
www.fmfelectric.com
T20
Mini Circuit Breaker

Standard: IEC 60898-1

Characteristics Curves

Tripping characteristics
Based on the Tripping Characteristics, MCB are available in”B”, “C” and “D” curves to suit different types of applications.
• “B” Curve for proteccion of electrical circuits with equipment that does not cause surge current (lightning and distribution circuits).
Short circuit release is set to 3~5 In.
• “C” Curve for protection of electrical circuits with equipment that cause surge current (inductive loads and motor circuits).
Short circuit release is set to 5~10 In.
• “D” Curve is for protection of electrical circuits which cause high inrush current, typically 12~15 times the thermal rated current
(transformers, x-ray machines, etc).
Short circuit release is set to 10~20 In.

Circuit Diagrams

12
www.fmfelectric.com
T20DC
Mini Circuit Breacker - DC

Standard: IEC 60947-2

Technical Data
Electrical Features
Ϸ Rated Current In: 1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A
Ϸ Poles: 1P, 2P, 4P
Ϸ Rated voltage Ue: 1P(250VDC), 2P(500VDC), 4P(1000VDC)
Ϸ Rated breaking capacity: 10.000A
Ϸ Rated impulse withstand voltage (1.5/50) Uimp: 4.000V
Ϸ Dielectric test voltage at ind. Freq. for 1 min: 2kV
Ϸ Pollution degree: 2
Ϸ Thermo-magnetic release characteristic: C (7~10)In

Mechanical Features
Ϸ Electrical life: 4.000 Cycles
Ϸ Mechanichal life: 10.000 Cycles
Ϸ Contact position indicator: YES
Ϸ Protecction degree: IP20
Ϸ Reference temperature for setting of thermal element: 30 °C
Ϸ Ambient temperature (with daily average •35°C): -5°C ~ +40°C
Ϸ Storage temperature: -25°C ~ +70°C

Installation
Ϸ Terminal connection type: Cable / Pin-type busbar / U-type busbar
Ϸ Terminal size top / bottom for cable: 25mm2 18-3AWG
Ϸ Terminal size top / bottom for busbar: 25mm2 18-3AWG
Ϸ Tightening torque: 2.5 Nm 22In-lbs
Ϸ Mounting: On DIN rail EN60715 (35mm) by means of fast clip device
Ϸ Connection: According to the wiring diagram

Combination with accesories


Ϸ Auxiliary contact: YES
Ϸ Alarm contact: YES
Ϸ Shunt release: YES
Ϸ Over / under voltage release: YES

Overall and Installation Dimension (mm)

13
www.fmfelectric.com
T20DC
Mini Circuit Breaker - DC

Standard: IEC 60947-2

Characteristics Curves

Circuit Diagrams

14
www.fmfelectric.com
T10 - T11
Moulded Case Circuit Breaker

Standard: IEC 60947-2

Product Overview
T10 and T11 Series of circuit breakers are new upgraded circuit breakers researched and developed by the
company combined with the advantages of similar international products and demand of domestic and
international markets.

With insulation voltage up to 1000V, the circuit breaker is applicable for distribution systems of AC 50Hz, rated
working voltage 690V and rated working current from 10A to 800A, used to distribute electric power energy,
protect circuits and power equipment against overload, short circuit, undervoltage and so on, also can be
used for infrequent startup of motor and protect it from overload, short circuit or undervoltage.

It is featured with small size, high breaking, short flashover, etc., is the ideal product for users. It can be
vertically or horizontally installed.

T11DC Series moulded-case circuit breaker (hereinafter referred to as circuit breaker) is suitable for DC
systems of rated voltage up to and including DC 1000V and rated current 10~800A, used to distribute electric
power energy, protect circuits and power equipment against overload, short circuit and so on.

The products can be fed with wires frem top and bottom, and it is polarity-free.

It complies with the standards IEC60947-2, GB14048.2, etc.

Product Features
1 Current limiting capacity
Current-limiting refers to limit of the increase of short-circuit in the loop, and in the loop protected by T10 &
T11 Series, peak value of the short-circuit current and the I2t energy in the circuit will be much smaller than the
prospective value.

Unique U-shaped static contact can achieve pre-breaking technology:


The so-called pre-breaking technology refers to when short-circuit current
flows through the contact system, electric power generated by U-shaped static
contact and moving contact is mutual exclusive. The greater the short-circuit
current is, the greater the repulsion of the electromotive force, and it is
generated together with the short-circuit current at the same time. Before the
trip action occurs, the electrodynamic repulsion force can make the static and
moving contact separation, by increasing the arc to increase the equivalent
resistance between them to achieve the purpose of suppresing increase of
short-circuit current.

2 Modularized accesories
For the circuit breakers of the same frame, they has uniform sizes regardles of the breaking capacity and rated
current.

Users can freely choose and expand functions of circuit breakers according to
their needs.

Modularizes accesories have insulation function, which is easy for hot line
operation and installation.

15
www.fmfelectric.com
T10 - T11
Moulded Case Circuit Breaker

Standard: IEC 60947-2

Product Features
3 Miniaturized frame
5 frame sizes: 125 type, 160 type, 250type, 630type, 1250type.
Rated current of T10/T11 series 10A~1250A

4 Contact repulsion device (patented technology)


The technical scheme adopted by the invention is:

As shown in Figure 1, the new contact device is mainly consisted of static contact, moving contact, shaft 1, shaft
2, shaft 3 and springs.

When the circuit breaker is in the closed state, shaft 2 acts on the right side of the srping angle; When the
circuit breaker has a large fault current, the moving contact will be subjected to the electric repulsion
generated by the current itself, and rotate with the center of shaft 1, when shaft 2 ratates to the top of the
spring angle with the moving contact, it makes moving contact to rapidly rotate upwards and quickly break
the circuit upon the reaction of srping, it has enhanced the breaking capacity of the product through
optimization of the contact structure.

16
www.fmfelectric.com
T10 - T11
Moulded Case Circuit Breaker

Standard: IEC 60947-2

Product Features
5 Modularized arc extinguishing system
The unique design of each arc extinguishing device perfectly fits each moulded case circuit breaker
requierments.

6 Unification
The six series of T10 and T11 under the same frame size have the same dimensions, installation dimensions and
appearence style, which is completely unified design.

17
www.fmfelectric.com
T10 - T11
Moulded Case Circuit Breaker

Standard: IEC 60947-2

Ambient and Installation Conditions


• Altitude up to 2000m
• Ambient medium temperature shouldbe within -10°C to +55°C
• It can withstand the effect of damp air
• It can withstand the effect of moulds
• It can withstand the effect of nuclear radiation
• The max inclination is 22.5°
• It can still work reliably when the ship subjects to normal vibration
• It can still work reliably if the products subjects to the earthquake (4G)
• Places where the surrounding medium is free from explosion danger, and far away from gas or
conductive dust that would erode the metal or destroy the insulation
• Keep away from rain or snow

Components of Circuit Breakers

18
www.fmfelectric.com
T10
Thermo-magnetic double adjustable MCCB

Standard: IEC 60947-2

Main Performance Indexes

Frame current (A) 160 250

Model T10-S T10-H T10-S T10-H

Pole number 3, 4 3, 4

20-25, 25-32, 32-40, 40-50, 50-63, 100-125, 125-160,


Rated current (A) 63-80,80-100, 100-125A, 125-160A 160-200, 200-250A

Rated voltage (V) AC400V AC400V

Rated insulation voltage (V) AC1000V AC1000V

Short-circuit breaking
capacity(KA)Icu/Ics 25/18 50/35 25/18 

Electrical life 3000 3000


Operating cycle number
Mechanical life 7000 7000

2XWOLQHGLP PP
DEFFD
FD 3P 90-155-68-90 90-155-88-115 105-165-68-92 

4P   140-165-68-92 


E

D F

3P 1.0 1.1 1.5 1.7


:HLJKW NJ
4P 1.1 1.7 1.9 2.1

Electric operating device (MD) ͷ

External driving operating handle ͷ

Automatic release Thermal electromagnetic type

19
www.fmfelectric.com
T10
Thermo-magnetic double adjustable MCCB

Standard: IEC 60947-2

Main Performance Indexes

Frame current (A) 400 630 1250

Model T10-S T10-H T10-S T10-H T10-S T10-H

Pole number 3, 4 3, 4 3, 4

200-250, 250-320, 400-500, 500-630 630-800, 800-1250


Rated current (A) 320-400

Rated voltage (V) AC400V AC400V AC400V

Rated insulation voltage (V) AC1000V AC1000V AC1000V

Short-circuit breaking 35/25 65/65 35/25 65/65 50/35 65/50


capacity(KA)Icu/Ics

Electrical life 2000 2000 1500


Operating cycle number
Mechanical life 4000 4000 4000

Outline dim(mm)
a-b-c-ca
ca 3P 140-257-103-155 140-257-103-155 210-275-103-155

4P 185-257-103-155 185-257-103-155 280-275-103-155


b

a c

3P 5.5 5.7 9.5


Weight (kg)
4P 7.0 7.5 12.5

Electric operating device (MD) ͷ

External driving operating handle ͷ

Automatic release 7KHUPDOHOHFWURPDJQHWLFW\SH

20
www.fmfelectric.com
T11
Thermo-magnetic type MCCB - High power

Standard: IEC 60947-2

Main Performance Indexes

Frame current (A) 125 160


Model T11-S T11-H T11-S T11-H
Pole number 1, 2, 3, 4 2, 3, 4

10, 16, 20, 25, 32, 40, 50, 63


Rated Current (A) 63, 80, 100, 125, 140, 160
80, 100, 125
Rated Voltage (V) AC 400V AC 400V
Rated insulation voltage (V) AC 1000V AC 1000V
Short- circuit breaking 25/18 35/25 25/18 50/35
AC 400V
capacity (kA) ICU/ICS
Electrical life 6000 3000

Mechanical life 9000 7000

Outline dimensions (mm) 1P 25-130-68-90 -

2P 50-130-68-90 60-155-68-90 60-155-88-115


3P 75-130-68-90 90-155-68-90 90-155-88-115

4P 100-130-68-90 120-155-68-90 120-155-88-115


1P 0.32 - -
Weight (kg)
2P 0.5 0.55 1.0 1.1
3P 0.55 0.65 1.1 1.2
4P 0.65 0.8 1.4 1.5
Electric operating device (MD)

External driving operating handle


Automatic release Thermal electromagnetic type

21
www.fmfelectric.com
T11
Thermo-magnetic type MCCB - High power

Standard: IEC 60947-2

Main Performance Indexes

Frame current (A) 250 400


Model T11-S T11-H T11-S T11-H
Pole number 3, 4 3, 4

100, 125, 140, 160, 180,


Rated Current (A) 250, 315, 350, 400
200, 225, 250
Rated Voltage (V) AC 400V AC 400V
Rated insulation voltage (V) AC 1000V AC 1000V
Short- circuit breaking 25/18 50/35 35/25 65/65
AC 400V
capacity (kA) ICU/ICS
Electrical life 3000 2000

Mechanical life 7000 4000

Outline dimensions (mm) 3P 105-165-68-92 105-165-88-115 140-257-103-155

4P 140-165-68-92 140-165-88-115 184-257-103-155

3P 1.5 1.7 5.5


Weight (kg)
4P 1.9 2.1 7.0

Electric operating device (MD)

External driving operating handle


Automatic release Thermal electromagnetic type

22
www.fmfelectric.com
T11
Thermo-magnetic type MCCB - High power

Standard: IEC 60947-2

Main Performance Indexes

Frame current (A) 630 1250


Model T11-S T11-H T11-S T11-H
Pole number 3, 4 3, 4

Rated Current (A) 250, 315, 350, 400, 500, 630 500, 630, 700, 800, 1250

Rated Voltage (V) AC 400V AC 400V


Rated insulation voltage (V) AC 1000V AC 1000V
Short- circuit breaking 35/25 65/65 35/25 65/65
AC 400V
capacity (kA) ICU/ICS
Electrical life 2000 1500

Mechanical life 4000 4000

Outline dimensions (mm) 3P 140-257-103-155 210-275-103-155

4P 184-257-103-155 280-275-103-155

3P 5.7 9.5
Weight (kg)
4P 7.5 12.5

Electric operating device (MD)

External driving operating handle


Automatic release Thermal electromagnetic type

23
www.fmfelectric.com
T1
Air Circuit Breaker

Standard: IEC 60947-2

T1-2000 T1-3200

Type Selection Guide


T1 2000 3P 400A F AC 230V Horizontal wiring

Code of control circuir


Product code Frame size Pole number Current class Installation code source voltage Connection mode

Type Selection of Standard Parts and Optional Accesories


M type 230V 230V 230V 6 NO 6 NC

Model of controller Voltage of shunt release Voltage of energy Voltage of electric Auxiliary contact
releasing electromagnet opertating mechanism

Operating Characteristics
T1-2000/3P 400A AC230V (fixed type 3-pole 400A voltage of control circuit (230V) default horizontal wiring, rated voltage
400V, M type controller, shunt 230V, electric operating mechanism 230V, standard 6 NO 6 NC contacts).
Please specify according to the above table if need other accesories.

24
www.fmfelectric.com
T1
Air Circuit Breaker

Standard: IEC 60947-2

Model Guide of Intelligent Controller

25
www.fmfelectric.com
T1
Air Circuit Breaker

Standard: IEC 60947-2

Main Performance Indexes

T1 - 2000 T1 - 3200 T1 - 6300

26
www.fmfelectric.com
T1
Air Circuit Breaker

Standard: IEC 60947-2

Overall and Mounting Dimensions (mm)

Outline and installation dimensions of fixed type circuit breaker (T1-2000, T1-2000/4)

Outline and installation dimensions of fixed type circuit breaker (T1-3200, T1-3200/4)

27
www.fmfelectric.com
T1
Air Circuit Breaker

Standard: IEC 60947-2

Overall and Mounting Dimensions (mm)


Outline and installation dimensions of drawout type circuit breaker (T1-2000, T1-2000/4)

Outline and installation dimensions of drawout type circuit breaker (T1-3200, T1-3200/4)

28
www.fmfelectric.com
T1
Air Circuit Breaker

Standard: IEC 60947-2

Overall and Mounting Dimensions (mm)


Outline and installation dimensions of drawout type circuit breaker (T1-4000)

Outline and installation dimensions of drawout type circuit breaker (T1-4000/4)

29
www.fmfelectric.com
T1
Air Circuit Breaker

Standard: IEC 60947-2

Overall and Mounting Dimensions (mm)


Outline and installation dimensions of drawout type circuit breaker (T1-6300, T1-6300/4, In=4000,5000A)

Outline and installation dimensions of drawout type circuit breaker (T1-6300, T1-6300/4, In=6300A)

30
www.fmfelectric.com
T1
Air Circuit Breaker - Accesories

Standard: IEC 60947-2

Standard
Accesories

Electric
Accesories

31
www.fmfelectric.com
MCB Characteristics

T- Series & D-Series Circuit Diagrams

32
www.fmfelectric.com
RCCB & RCBO Characteristics

33
www.fmfelectric.com
RCCB & RCBO Parameters and Properties

34
www.fmfelectric.com
Contactors

Contactors Sub-Index
C96 - Mini Contactor..............................................................................36
C98 - Contactor........................................................................................38
C98C - Contactor for Capacitor.............................................................45
RT - Thermal Overload Relay.............................................................47
C86 - DOL Electromagnetic Starter....................................................52
C96
Mini Contactor 6~12A

Standard: IEC 60947-4-1


IEC 60947-5-1

Description

Application: Remote making & breaking circuits;


Protect circuits from over-load when assembling
with thermal over-load relay;
Frequent start-up and control of AC contactor.
Electric value: AC 50/60Hz, 690V, up to 12A
Utilization category: AC-3, AC-4
Altitude: •2000m
Ambient temperature: -5°C ~ +40°C
Mounting category: III
Mounting conditions: Inclination between the mounting plane and the
vertical plane should mnot exceed ±5°
Standard: IEC 60947-4-1
IEC 69047-5-1

Control Coil Voltage (AC Coil Operation)

Control Coil Voltage (DC Coil Operation)

36
www.fmfelectric.com
C96
Mini Contactor 6~12A

Standard: IEC 60947-4-1


IEC 60947-5-1

Technical Specification

C96 - 06 C96 - 09 C96 - 12

Overall and Mounting Dimensions (mm)


C96 - 06

C96 - 09/12

37
www.fmfelectric.com
C98
Contactor 9~95A

Standard: IEC 60947-4-1


IEC 60947-5-1

Description

Application: Remote making & breaking circuits;


Protect circuits from over-load when assembling
with thermal over-load relay;
Frequent start-up and control of AC contactor.

Electric value: AC 50/60Hz, 690V, up to 95A


Utilization category: AC-3, AC-4
Altitude: •2000m
Ambient temperature: -5°C ~ +40°C
Mounting category: III
Mounting conditions: Inclination between the mounting plane and the
vertical plane should mnot exceed ±5°
Standard: IEC 60947-4-1
IEC 69047-5-1

Control Coil Voltage (AC Coil Operation)

38
www.fmfelectric.com
C98
Contactor 9~95A

Standard: IEC 60947-4-1


IEC 60947-5-1

Technical Specification

C98-09 C98-12 C98-18 C98-25 C98-32

C98-40 C98-50 C98-65 C98-80 C98-95

39
www.fmfelectric.com
C98
Contactor 9~95A

Standard: IEC 60947-4-1


IEC 60947-5-1

Technical Specification
Terminal connection

C98-09
C98-12
C98-18

C98-25

C98-32

C98-40

C98-50

C98-65

C98-80

C98-95

Curve

40
www.fmfelectric.com
C98
Contactor 9~95A

Standard: IEC 60947-4-1


IEC 60947-5-1

Overall and Mounting Dimensions (mm)

C98-09~32

C98-40~95

C98 - 09~12
C98 - 18
C98 - 25
C98 - 32
C98 - 4011~6511
C98 - 4004/4008~6504/6508
C98 - 8011~9511
C98 - 8004/8008~9504/9508

41
www.fmfelectric.com
C98
Contactor 115~1000A

Standard: IEC 60947-4-1

Description

Application: Remote making & breaking circuits;


Protect circuits from over-load when assembling
with thermal over-load relay;
Frequent start-up and control of AC contactor.

Electric value: AC 50/60Hz, 690V, up to 1000A


C98-150 Utilization category: AC-3, AC-4
Altitude: •2000m
Ambient temperature: -5°C ~ +40°C
Mounting category: III
Mounting conditions: Inclination between the mounting plane and the
vertical plane should mnot exceed ±5°
Standard: IEC 60947-4-1
IEC 69047-5-1

C98-265
AC Coil Operation

Volts (VAC) 24 36 42 48 110 127 220 230 240 380 415 440 480 500 600

DC Coil Operation

Volts (VAC) 12 24 36 48 110 220


C98-400
Code JD BD CD ED FD MD

C98-630

42
www.fmfelectric.com
C98
Contactor 115~1000A

Standard: IEC 60947-4-1

Technical Specification

Standard IEC / EN60947-4-1


Model No. C98-115 C98-150 C98-185 C98-225 C98-265 C98-330
Rated Conventional Heating Current Ith (A) 200 200 275 275 315 330
Rated Voltage Ui (V) Ui (V) 690 690 690 690 690 690
Rated Operation Current AC-3 Ie (A) 115 150 185 225 265 330
Ue = 380/415V AC-4 Ie (A) 52 60 79 86 105 117
C98-150
Power Controlled 380/415V KW 55 75 90 110 132 160
3ph cage Motor AC-3 660/690V KW 80 100 110 129 160 220
AC-3 600 600 300 300 300 300
Electrical life (x103 operations)
AC-4 100 100 100 100 100 100
6
Mechanical life (x10 operations) 6 6 3 3 3 3
Size RT16-1 RT16-2 RT16-2 RT16-2 RT16-2 RT16-3
Matched Fuse
A 200 225 315 315 335 450
C98-265 Main Circuit 3P or 4P

Standard IEC / EN60947-4-1


Model No. C98-400 C98-500 C98-630 C98-780 C98-800 C98-1000
Rated Conventional Heating Current Ith (A) 460 580 850 1200 850 1200
Rated Voltage Ui (V) Ui (V) 690 690 690 690 690 690
Rated Operation Current AC-3 Ie (A) 400 500 630 780 800 1000
Ue = 380/415V AC-4 Ie (A) 138 147 188 240 195 320
Power Controlled 380/415V KW 200 250 335 400 400 500
C98-400
3ph cage Motor AC-3 660/690V KW 280 335 450 475 475 560
AC-3 300 300 300 200 200 200
Electrical life (x103 operations)
AC-4 100 100 100 50 50 50
Mechanical life (x106 operations) 3 3 3 2 3 2
Size RT16-3 RT16-4 RT16-4 RT16-4 RT16-4 RT16-4
Matched Fuse
A 500 630 800 1250 800 1250
Main Circuit 3P or 4P

C98-630

43
www.fmfelectric.com
C98
Contactor 115~1000A

Standard: IEC 60947-4-1

Technical Specification
Terminal connection
Cabling cross section (Cu) Tightening
Model Number of Cable Cu busbar Screw torque
piece Cross section (mm2) Cross section (mm2) size (Nm)

C98-115 1 70~90 - M6 3
C98-150 1 70~90 - M8 6
C98-185 1 95~150 - M8 6
C98-225 1 95~150 - M10 10
C98-150 C98-265 1 120~185 - M10 10
C98-330 1 185~240 - M10 10
C98-400 1 (2) 240 (150) 30 x 5 M10 10
C98-500 2 150~185 40 x 5 M10 10
C98-630 2 185~240 50 x 5 M12 14
C98-800 2 185~240 50 x 5 M12 14

C98-265 Overall and Mounting Dimensions (mm)


C98-115~330 C98-400~500 C98-630~800

C98-400

Model A Max B max C max


C98-115 163.5 162 171
C98-150 163.5 170 171
C98-185 168.5 174 181
C98-225 168.5 197 181
C98-265 201.5 203 213
C98-630 C98-330 213 206 219
C98-400 213 206 219
C98-500 233 238 232
C98-630/800 309 304 255

44
www.fmfelectric.com
C98C
Capacitor Switching Contactor

Standard: IEC 60947-4-1

Description
Electric value: AC 50/60Hz, up to 690V
Ambient temperature: -5°C ~ +40°C; the average during 24 hours should not
exceed +35°C
Altitude: •2000m
Atmosphere conditions: At mounting site, relative humidity not exceed 50% at the
max temperature of 40°C, higher relative humidity is
allowable under lower temperature.
For example, RH could be 90% at +20°C, special measures
should be taken to occurrence of dews.
Pollution degree: 3
Installation category: III
C98-12C Installation conditions: The inclination between the mounting plane and the
vertical plane is within ±5°
Impact and shake: The products should locate in places where there are no
obvious impact and shake

Technical Specification

Standard IEC / EN60947-4-1


Model No. C98-12C C98-16C C98-20C C98-25C C98-33C C98-40C C98-60C
Contactor size C98-18 C98-25 C98-32 C98-40 C98-50 C98-65 C98-95
Rated Conventional Heating Current Ith (A) 32 40 50 60 80 80 125
Rated Work Current 415V/le(A) 18 25 32 40 50 65 95
Capacitor Controlled 220/240V (Kvar) 6 8 10 12.5 16.5 20 30
400/440V (Kvar) 12 16 20 25 33 40 60
C98-20C Rated Insulation Voltage Ui (V) 690 690 690 690 690 690 690
Rated Operation Voltage Ue (V) 400 400 400 400 400 400 400
Electrical life (x103) Times 120 120 120 100 100 100 100
Mechanical life (x106) Times 3000 3000 3000 3000 3000 3000 3000
Restrained Surge Capacity x Ie 15
Auxiliary Contact lth=10A 1NO+1NC 1NO+2NC
Control capacity AC-15 360VA , DC-13 33W
COIL PARAMETERS
Coil Power (VA) Start-up 76 110 110 230 230 230 230
Holding 10 11 11 32 32 32 32
Rated Control Power Us (V) 24, 36, 48, 110, 220, 380
Pull time Ms 12~22 15~24 15~24 20~26 20~26 20~26 20~35
Release time Ms 4~12 5~19 5~19 8~12 8~12 8~12 6~20
Operation Range Pick-up (85% - 110%) Us
Drop-out (20% - 75%) Us

C98-60C

45
www.fmfelectric.com
C98C
Capacitor Switching Contactor

Standard: IEC 60947-4-1

Overall and Mounting Dimensions (mm)


C98-12C~20C

C98C-12
C98-25C~60C

Model A Max B Max C Max D Max E F Note


C98-12C 80 47 124 76 34/35 50/60
C98-16C 90 57 132 86 40 48 be fixed with 35mm DIN rail
C98C-20 C98-20C 90 57 132 86 40 48
C98-25C 132 77 150 - - -
Not only fixed by screws
C98-33C 132 77 150 - - -
but also could be fixed with
C98-40C 132 77 150 - - - 35mm and 75mm DIN rail
C98-60C 135 87 162 - - -

Wiring and installation


The connection terminals are protected through insulation cover, which is reliable
and secure for installation and operation;
For C98-12C~20C, screws are available for installation, as well as the DIN rail;
For C98-25C~60C, 35mm or 75mm standard rail are available for installation.

C98C-60

46
www.fmfelectric.com
RT
Thermal Overload Relay

Standard: IEC 60947-4-1

Description

Feature
3-phase bimetal
Continuously readjustable current settings
Temperatures compensation
Tripping indicator
Test button
Stop button
Manual and automatic reset button
Electrically separated 1N/O plus 1N/C contact

Technical Specification
Protection property

47
www.fmfelectric.com
RT
Thermal Overload Relay

Standard: IEC 60947-4-1

Curve Main Technical data

Assembly with contactor

C98-09
C98-12
RT13 C98-18
C98-25
C98-32

RT23 C98-32

C98-40
C98-50
RT33 C98-65
C98-80
C98-95

48
www.fmfelectric.com
RT
Thermal Overload Relay

Standard: IEC 60947-4-1

Overall and mounting dimension (mm)

RT13

RT23

RT33

49
www.fmfelectric.com
Contactor Accesories

Standard: IEC 60947-4-1

Specification Model Contact Number Contactor matched


02AF40 4NO
02AF31 3NO+1NC
Auxiliary Contact
4-pole 02AF22 2NO+2NC
Front mount
02AF13 1NO+3NC
C98-09~95
02AF04 4NC
02AF20 2NO
Auxiliary Contact
2-pole 02AF11 1NO+1NC
Front mount
02AF02 2NC
02AL20 2NO
Auxiliary Contact
2-pole 02AL11 1NO+1NC C98-09~95
Side mount
02AL02 2NC
02TON0 0.1~3s
1NO+1NC
Pneumatic timer 02TON2 0.1~30s
ON-Delay
02TON4 10~180s
C98-09~95
02TOF0 0.1~3s
1NO+1NC
Pneumatic timer 02TOF2 0.1~30s
OFF-Delay
02TOF4 10~180s
02AF40M 4NO
02AF31M 3NO+1NC
Auxiliary Contact
4-pole 02AF22M 2NO+2NC C96
Front mount 02AF13M 1NO+3NC
02AF04M 4NC
02B1-2XXX(volts) AC Volts AC C98-09~18
Contactor Coil 02B1-4XXX(volts) AC Volts C98-25~32
02B1-6XXX(volts) AC Volts C98-40~95
02A90932 C98-09~32
02A94095 C98-40~95

Accesories for 02A9FF970 C98-115~150


Reversing & 02A9FB970 Contactor Matched C98-185~225
change-over type
contactor 02A9FH970 C98-265~330
02A9FJ970 C98-400~500
02A9FL970 C98-630~800

50
www.fmfelectric.com
Contactor Accesories

Standard: IEC 60947-4-1

Mounting Sketch Map

51
www.fmfelectric.com
C86
DOL Electromagnetic Starter

Standard: IEC 60947-4-1

Description
C-86 Series Electromagnetic Starter ( “starter” for short hereinafter) applies
mainly to circuit with AC current of 50Hz (or 60Hz), rated operational voltage of 660V
and rated controlled power up to 15kW (current up to 32A) for using to control the
direct start and halt of the electromotor to protect the motor from overload and
phase failure.

The starter conforms to standards IEC/EN 60947-4-1

Feature
3-phase bimetal
Continuously readjustable current settings
Temperature compensation
Tripping indicator
Test button
Stop button
Manual and automatic reset button
Electrically separated 1N/O plus 1N/C contact

Wiring Diagram

52
www.fmfelectric.com
C86
DOL Electromagnetic Starter

Standard: IEC 60898-1

Basic Model and main technical parameters of the starters

C98-09 RT-13

C98-18 RT-13

C98-25 RT-13

C98-32 RT-23
C98-40 RT-33
C98-50 RT-33
C98-65 RT-33

C98-80 RT-33

C98-95 RT-33

Overall and Mounting Dimension (mm)


C86-09~18 (Plastic base + Plastic cover) C86-25~32 (Plastic base + Plastic cover)

53
www.fmfelectric.com
Notes

54
www.fmfelectric.com
Protection

Protection Sub-Index
D16 - Surge Protective Device ................................................................. 56
G06 - Motor Protection Circuit Breaker................................................. 63
F1 - Modular Fuse Base........................................................................... 65
FL - Fuse Link.............................................................................................. 67
CM - Monitoring Relay.............................................................................. 68
D16
Surge Protective Device

Standard: IEC 60947-2

Product Selection Guide

03 D16 1P 275 5 1+2 S

With remote signaling


Classification: 1+2: T1+T2 / 2: T2
Imax: 2:20kA / 4: 40kA / 5: 50kA / 6: 60kA
Uc: 150: 150V / 275: 275V / 320: 320V / 385: 385V / 400: 400V
Number of Poles: 1: 1P / 2: 2P(1P+N) / 3: 3P / 4: 4P(3P+N) / 1PN: 1P+NPE / 3PN: 3P+NPE
SPD Series
Family code

D16 D16 D16 D16 D16


2P (1P+N) 1P+PNE 3P 4P (3P+N) 3P+NPE

Basic circuit diagram

1P 2P (1P+N) 1P+PNE 3P 4P (3P+N) 3P+NPE

56
www.fmfelectric.com
D16
Surge Protective Device T1+T2 50kAmp

Standard: IEC 61643-11


SPD Type Reference List
Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V 440V
1P 03 D16 1P 150 5 1+2 03 D16 1P 275 5 1+2 03 D16 1P 320 5 1+2 03 D16 1P 385 5 1+2 03 D16 1P 440 5 1+2
2P (1P+N) 03 D16 2P 150 5 1+2 03 D16 2P 275 5 1+2 03 D16 2P 320 5 1+2 03 D16 2P 385 5 1+2 03 D16 2P 440 5 1+2
3P 03 D16 3P 150 5 1+2 03 D16 3P 275 5 1+2 03 D16 3P 320 5 1+2 03 D16 3P 385 5 1+2 03 D16 3P 440 5 1+2
4P (3P+N) 03 D16 4P 150 5 1+2 03 D16 4P 275 5 1+2 03 D16 4P 320 5 1+2 03 D16 4P 385 5 1+2 03 D16 4P 440 5 1+2
1P+NPE 03 D16 1PN 150 5 1+2 03 D16 1PN 275 5 1+2 03 D16 1PN 320 5 1+2 03 D16 1PN 385 5 1+2 03 D16 1PN 440 5 1+2
3P+NPE 03 D16 1PN 150 5 1+2 03 D16 1PN 275 5 1+2 03 D16 1PN 320 5 1+2 03 D16 1PN 385 5 1+2 03 D16 1PN 440 5 1+2

With remote signaling


Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V 440V
1P 03 D16 1P 150 5 1+2 S 03 D16 1P 275 5 1+2 S 03 D16 1P 320 5 1+2 S 03 D16 1P 385 5 1+2 S 03 D16 1P 440 5 1+2 S
2P (1P+N) 03 D16 2P 150 5 1+2 S 03 D16 2P 275 5 1+2 S 03 D16 2P 320 5 1+2 S 03 D16 2P 385 5 1+2 S 03 D16 2P 440 5 1+2 S
3P 03 D16 3P 150 5 1+2 S 03 D16 3P 275 5 1+2 S 03 D16 3P 320 5 1+2 S 03 D16 3P 385 5 1+2 S 03 D16 3P 440 5 1+2 S
4P (3P+N) 03 D16 4P 150 5 1+2 S 03 D16 4P 275 5 1+2 S 03 D16 4P 320 5 1+2 S 03 D16 4P 385 5 1+2 S 03 D16 4P 440 5 1+2 S
1P+NPE 03 D16 1PN 150 5 1+2 S 03 D16 1PN 275 5 1+2 S 03 D16 1PN 320 5 1+2 S 03 D16 1PN 385 5 1+2 S 03 D16 1PN 440 5 1+2 S
3P+NPE 03 D16 1PN 150 5 1+2 S 03 D16 1PN 275 5 1+2 S 03 D16 1PN 320 5 1+2 S 03 D16 1PN 385 5 1+2 S 03 D16 1PN 440 5 1+2 S

Technical Data

Overall and Mounting Dimension (mm)

57
www.fmfelectric.com
D16
Surge Protective Device T1+T2 60kAmp

Standard: IEC 61643-11


SPD Type Reference List
Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V
1P 03 D16 1P 150 6 1+2 03 D16 1P 275 6 1+2 03 D16 1P 320 6 1+2 03 D16 1P 385 6 1+2
2P (1P+N) 03 D16 2P 150 6 1+2 03 D16 2P 275 6 1+2 03 D16 2P 320 6 1+2 03 D16 2P 385 6 1+2
3P 03 D16 3P 150 6 1+2 03 D16 3P 275 6 1+2 03 D16 3P 320 6 1+2 03 D16 3P 385 6 1+2
4P (3P+N) 03 D16 4P 150 6 1+2 03 D16 4P 275 6 1+2 03 D16 4P 320 6 1+2 03 D16 4P 385 6 1+2
1P+NPE 03 D16 1PN 150 6 1+2 03 D16 1PN 275 6 1+2 03 D16 1PN 320 6 1+2 03 D16 1PN 385 6 1+2
3P+NPE 03 D16 1PN 150 6 1+2 03 D16 1PN 275 6 1+2 03 D16 1PN 320 6 1+2 03 D16 1PN 385 6 1+2

With remote signaling


Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V
1P 03 D16 1P 150 6 1+2 S 03 D16 1P 275 6 1+2 S 03 D16 1P 320 6 1+2 S 03 D16 1P 385 6 1+2 S
2P (1P+N) 03 D16 2P 150 6 1+2 S 03 D16 2P 275 6 1+2 S 03 D16 2P 320 6 1+2 S 03 D16 2P 385 6 1+2 S
3P 03 D16 3P 150 6 1+2 S 03 D16 3P 275 6 1+2 S 03 D16 3P 320 6 1+2 S 03 D16 3P 385 6 1+2 S
4P (3P+N) 03 D16 4P 150 6 1+2 S 03 D16 4P 275 6 1+2 S 03 D16 4P 320 6 1+2 S 03 D16 4P 385 6 1+2 S
1P+NPE 03 D16 1PN 150 6 1+2 S 03 D16 1PN 275 6 1+2 S 03 D16 1PN 320 6 1+2 S 03 D16 1PN 385 6 1+2 S
3P+NPE 03 D16 1PN 150 6 1+2 S 03 D16 1PN 275 6 1+2 S 03 D16 1PN 320 6 1+2 S 03 D16 1PN 385 6 1+2 S

Technical Data

Overall and Mounting Dimension (mm)

58
www.fmfelectric.com
D16
Surge Protective Device T2 20kAmp

Standard: IEC 61643-11


SPD Type Reference List
Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V 440V
1P 03 D16 1P 150 2 2 03 D16 1P 275 2 2 03 D16 1P 320 2 2 03 D16 1P 385 2 2 03 D16 1P 440 2 2
2P (1P+N) 03 D16 2P 150 2 2 03 D16 2P 275 2 2 03 D16 2P 320 2 2 03 D16 2P 385 2 2 03 D16 2P 440 2 2
3P 03 D16 3P 150 2 2 03 D16 3P 275 2 2 03 D16 3P 320 2 2 03 D16 3P 385 2 2 03 D16 3P 440 2 2
4P (3P+N) 03 D16 4P 150 2 2 03 D16 4P 275 2 2 03 D16 4P 320 2 2 03 D16 4P 385 2 2 03 D16 4P 440 2 2
1P+NPE 03 D16 1PN 150 2 2 03 D16 1PN 275 2 2 03 D16 1PN 320 2 2 03 D16 1PN 385 2 2 03 D16 1PN 440 2 2
3P+NPE 03 D16 1PN 150 2 2 03 D16 1PN 275 2 2 03 D16 1PN 320 2 2 03 D16 1PN 385 2 2 03 D16 1PN 440 2 2

With remote signaling


Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V 440V
1P 03 D16 1P 150 2 2 S 03 D16 1P 275 2 2 S 03 D16 1P 320 2 2 S 03 D16 1P 385 2 2 S 03 D16 1P 440 2 2 S
2P (1P+N) 03 D16 2P 150 2 2 S 03 D16 2P 275 2 2 S 03 D16 2P 320 2 2 S 03 D16 2P 385 2 2 S 03 D16 2P 440 2 2 S
3P 03 D16 3P 150 2 2 S 03 D16 3P 275 2 2 S 03 D16 3P 320 2 2 S 03 D16 3P 385 2 2 S 03 D16 3P 440 2 2 S
4P (3P+N) 03 D16 4P 150 2 2 S 03 D16 4P 275 2 2 S 03 D16 4P 320 2 2 S 03 D16 4P 385 2 2 S 03 D16 4P 440 2 2 S
1P+NPE 03 D16 1PN 150 2 2 S 03 D16 1PN 275 2 2 S 03 D16 1PN 320 2 2 S 03 D16 1PN 385 2 2 S 03 D16 1PN 440 2 2 S
3P+NPE 03 D16 1PN 150 2 2 S 03 D16 1PN 275 2 2 S 03 D16 1PN 320 2 2 S 03 D16 1PN 385 2 2 S 03 D16 1PN 440 2 2 S

Technical Data

Overall and Mounting Dimension (mm)

59
www.fmfelectric.com
D16
Surge Protective Device T2 40kAmp

Standard: IEC 61643-11


SPD Type Reference List
Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V 440V
1P 03 D16 1P 150 4 2 03 D16 1P 275 4 2 03 D16 1P 320 4 2 03 D16 1P 385 4 2 03 D16 1P 440 4 2
2P (1P+N) 03 D16 2P 150 4 2 03 D16 2P 275 4 2 03 D16 2P 320 4 2 03 D16 2P 385 4 2 03 D16 2P 440 4 2
3P 03 D16 3P 150 4 2 03 D16 3P 275 4 2 03 D16 3P 320 4 2 03 D16 3P 385 4 2 03 D16 3P 440 4 2
4P (3P+N) 03 D16 4P 150 4 2 03 D16 4P 275 4 2 03 D16 4P 320 4 2 03 D16 4P 385 4 2 03 D16 4P 440 4 2
1P+NPE 03 D16 1PN 150 4 2 03 D16 1PN 275 4 2 03 D16 1PN 320 4 2 03 D16 1PN 385 4 2 03 D16 1PN 440 4 2
3P+NPE 03 D16 1PN 150 4 2 03 D16 1PN 275 4 2 03 D16 1PN 320 4 2 03 D16 1PN 385 4 2 03 D16 1PN 440 4 2

With remote signaling


Max. Continuous Operating AC Voltage
NO of Poles
150V 275V 320V 385V 440V
1P 03 D16 1P 150 4 2 S 03 D16 1P 275 4 2 S 03 D16 1P 320 4 2 S 03 D16 1P 385 4 2 S 03 D16 1P 440 4 2 S
2P (1P+N) 03 D16 2P 150 4 2 S 03 D16 2P 275 4 2 S 03 D16 2P 320 4 2 S 03 D16 2P 385 4 2 S 03 D16 2P 440 4 2 S
3P 03 D16 3P 150 4 2 S 03 D16 3P 275 4 2 S 03 D16 3P 320 4 2 S 03 D16 3P 385 4 2 S 03 D16 3P 440 4 2 S
4P (3P+N) 03 D16 4P 150 4 2 S 03 D16 4P 275 4 2 S 03 D16 4P 320 4 2 S 03 D16 4P 385 4 2 S 03 D16 4P 440 4 2 S
1P+NPE 03 D16 1PN 150 4 2 S 03 D16 1PN 275 4 2 S 03 D16 1PN 320 4 2 S 03 D16 1PN 385 4 2 S 03 D16 1PN 440 4 2 S
3P+NPE 03 D16 1PN 150 4 2 S 03 D16 1PN 275 4 2 S 03 D16 1PN 320 4 2 S 03 D16 1PN 385 4 2 S 03 D16 1PN 440 4 2 S

Technical Data

Overall and Mounting Dimension (mm)

60
www.fmfelectric.com
D16
Surge Protective Device

Standard: IEC 60947-2

Product Selection Guide

03 D16 2P 600 4 DC S

With remote signaling


Solar PV System
Imax: 4: 40kA
Uc: 600: DC 600V / 1000: DC 1000V / 1500: DC 1500V
Number of Modules: 2: 2 Modules / 3: 3 Modules
SPD Series
Family code

D16 D16 D16 D16


2P (600 VDC) 2P (1000 VDC) 3P (1000 VDC) 3P (1500 VDC)

Basic circuit diagram

61
www.fmfelectric.com
D16
Surge Protective Device

Standard: IEC 61643-31


SPD Type Reference List

No of
Modules 600 VDC 1000 VDC 1500 VDC
2 MODULES 03 D16 2P 600 4 DC 03 D16 2P 1000 4 DC -
3 MODULES - 03 D16 3P 1000 4 DC 03 D16 3P 1500 4 DC

With remote signaling


No of
Modules 600 VDC 1000 VDC 1500 VDC
2 MODULES 03 D16 2P 600 4 DC S 03 D16 2P 1000 4 DC S -
3 MODULES - 03 D16 3P 1000 4 DC S 03 D16 3P 1500 4 DC S

Technical Data

Overall and Mounting Dimension (mm)

62
www.fmfelectric.com
G06
Motor Protecction Circuit Breaker

Standard: IEC 60947-2

Description

Operating Condition
Temperature: -5°C ~ +40°C
average temperature in 24 hours not exceed +35°C
Altitude: not exceed 2000m
Air conditions:
At mounting site, relative humidity not exceed 50% at the max temperature of +40°C,
higher relative humidity is allowable under lower temperature, for example: RH could be
90% ant +20°C
Pollution grade: Grade III
Release grade: 10A
Rated operational system: Continuous operational system
Mounting conditions:
The inclination between the mounting plane and the vertical plane shall
not exceed 5°. The product shall be installed and operated at a place without
obvious shake, impact and bribation.
Technical Specification
Protection property

63
www.fmfelectric.com
G06
Motor Protecction Circuit Breaker

Standard: IEC 60898-1

0016
0025
0040
0063
0100
0160
0250
G06-32 0400
0630
1000
1400
1800
2300
2500
3200

Accessory

Rated insulation Conventional heating


Model Configuration Starter matched
voltage Ui (V) current Ith(A)

690 6 AUX 02 L 2N/O G06 - 32

Overall and Mounting Dimension (mm)

64
www.fmfelectric.com
F1
Modular Fuse Base

Standard: IEC 60269-2

Modular Fuse Base

F1.32.3 F1.32.1NS F1.63.4 F1.125.2

F1.L.32.4 F1.L63.1 F1.L.63.3


F1.L.125.3

Technical Data
32A, 63A, 125A
General type F1.32, F1.63, F1.125
With Indicator type F1.L.32, F1.L.63, F1.L.125
1P, 2P, 3P, 4P, 1P+N, 3P+N
AC-22A
240/415V~
500V
50/60Hz
4.000V
1.500 Cycles
8.500 Cycles
120/H
IP20
F1.32 - F1.L.32 1,5Nm 14In-lbs
F1.63 - F1.L.63 2,5Nm 22In-lbs
F1.125 - F1.L.125 3,5Nm 30In-lbs
F1.32 - F1.L.32 16mm2 18-5AWG
F1.63 - F1.L.63 25mm2 18-3AWG
F1.125 - F1.L.125 50MM2 18-2AWG
-5°C ~ +40°C
-25°C ~ +70°C
On DIN rail EN60715 (35mm) by means of fast clip device

65
www.fmfelectric.com
F1
Modular Fuse Base

Standard: IEC 60898-1

Specifications

F1.32.1N
1P+N 18 32A F110__ 10x38mm
F1.L.32.1N
F1.32
1-4P, 3P+N 18 32A F110__, FL10__DC 10x38mm
F1.L.32
F1.63
1-4P, 3P+N 27 63A F114__ 14x51mm
F1.L.63
F1.125
1-4P, 3P+N 35 125A F122__ 22x58mm
F1.L.125

Overall and Installation Dimension (mm)


F1.32 - F1.L.32

F1.63 - F1.L.63, F1.125 - F1.L.125

Size A1 A2 B H1 H1
F1.63
108 111 27 76 100
F1.L.63
F1.125
127 128 35 77 104
F1.L.125

66
www.fmfelectric.com
FL
Fuse Link

Standard: IEC 60269-2

Technical Data

Specifications

67
www.fmfelectric.com
CM
Monitoring Voltage Relay

Single Phase Voltage Protection Relay CM Series

Voltage protection relay uses a high-speed and low-


power processor as its core.
When the power supply line has over-voltage,
under-voltage, or phase-failure, phase reverse, the
relay will cut off the circuit quickly and safely to avoid
accidents caused by abnormal voltage being sent to
the terminal appliance.
When the voltage returns to the normal value, the
relay will turn on the circuit automatically to ensure the
normal operation of the terminal electrical appliances
under unattended conditions.

1. Cut off the line when Over & Under Voltage occurs,
and automatically reset and connect the line after
returning to normal without manual operation.

2. When the line appears transient or transient Over


& Under Voltage, the protector does not malfunction.

03CMV8010
Single Phase
SPDT
0 ~ 20%
0 ~ 20%
0.1 ~ 10s
-
-
AC 110V or 220V
50/60Hz
0.5s
AC-15:3A / 250VAC
-10°C ~ +55°C
±2% MAX
±2% MAX
: in (mm)

68
www.fmfelectric.com
CM
Monitoring Voltage Relay

3-phase 3-wire Voltage Protection Relay CM Series

Voltage protection relay uses a high-speed and low-


power processor as its core.
When the power supply line has over-voltage,
under-voltage, or phase-failure, phase reverse, the
relay will cut off the circuit quickly and safely to avoid
accidents caused by abnormal voltage being sent to
the terminal appliance.
When the voltage returns to the normal value, the
relay will turn on the circuit automatically to ensure the
normal operation of the terminal electrical appliances
under unattended conditions.

1. Cut off the line when Over & Under Voltage occurs,
and automatically reset and connect the line after
returning to normal without manual operation.

2. When the line appears transient or transient Over


& Under Voltage, the protector does not malfunction.

03CMV80301/2/3
Three Phase
SPDT
0 ~ 20%
0 ~ 20%
0.1 ~ 10s
¦
¦
AC 220V, 380V, 400V, 415V, 440V
50/60Hz
0.5s
AC-15:3A / 250VAC
-10°C ~ +55°C
±2% MAX
±2% MAX
: in (mm)

69
www.fmfelectric.com
CM
Monitoring Voltage Relay

Single Phase Voltage Protection Relay CM Series

Voltage protection relay uses a high-speed and low-


power processor as its core.
When the power supply line has over-voltage,
under-voltage, or phase-failure, phase reverse, the
relay will cut off the circuit quickly and safely to avoid
accidents caused by abnormal voltage being sent to
the terminal appliance.
When the voltage returns to the normal value, the
relay will turn on the circuit automatically to ensure the
normal operation of the terminal electrical appliances
under unattended conditions.

1. Cut off the line when Over & Under Voltage occurs,
and automatically reset and connect the line after
returning to normal without manual operation.

2. When the line appears transient or transient Over


& Under Voltage, the protector does not malfunction.

03CMV80304
3 Phase 3 wire
SPDT
-
-
3s
-
¦
Wide Voltage> AC 220 - 480V
50/60Hz
0.5s
AC-15:3A / 250VAC
-10°C ~ +55°C
±2% MAX
±2% MAX
: in (mm)

70
www.fmfelectric.com
CM
Monitoring Voltage Relay

Single Phase Voltage Protection Relay CM Series

Voltage protection relay uses a high-speed and low-


power processor as its core.
When the power supply line has over-voltage,
under-voltage, or phase-failure, phase reverse, the
relay will cut off the circuit quickly and safely to avoid
accidents caused by abnormal voltage being sent to
the terminal appliance.
When the voltage returns to the normal value, the
relay will turn on the circuit automatically to ensure the
normal operation of the terminal electrical appliances
under unattended conditions.

1. Cut off the line when Over & Under Voltage occurs,
and automatically reset and connect the line after
returning to normal without manual operation.

2. When the line appears transient or transient Over


& Under Voltage, the protector does not malfunction.

Dimensions: in (mm) Technical Data 03CMV80305

71
www.fmfelectric.com
CM
Monitoring Voltage Relay

Over/Under-current Monitoring Relay CM Series

When the working current suddenly increases or


decreases due to various faults of load, protective
measures must be taken, otherwise serious safety
accidents are likely to occur.
When the fault current reaches the set value of the
protector, the contact of the current relay is closed
after a pre-set delay, and the signal alarm device is
activated.

03CMI801

03CMI801 1A / 2A / 5A / 10A / 16A

Dimensions: in (mm)

72
www.fmfelectric.com
CM
Voltage Protector

Standard: IEC 60255-1


IEC60947-5-1

General
Applications
Overvoltage and undervoltage protection for household equipment.

Function Features
Supply voltage measurement and protection.
Double bus wiring design stronger ability.
Self reset after fault.
Relay status is indicated by LED.
1-MODULE, DIN rail mounting.

Model and connotation


CMV8 . 63

U:upper incoming line


D:lower incoming line

Frame size
CMV8 self-resettingover-voltage protection

Note:4P products such as the need to phase protection function can be customized.

Technical parameters
Technical parameters 2P 4P
Rated supply voltage AC220V AC220V(L-N)
Rated supply frequency 50/60Hz
Rated operational current 32A, 40A, 50A, 63A (AC1)
Burden AC max.3VA
Over voltage operation value 265V 265V (L-N)
Over voltage reset value 257V 257V(L-N)
Under voltage operation value 175V 175V(L-N)
Under voltage reset value 180V 180V(L-N)
Action delay time 1s
Power up delay 2s
Reset time 30s
Measurement error 1%
Operating temperature -20 to +55 -4 to 131
Storage temperature -35 to +75 -22 to 158
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage cathegory
Pollution degree 2
Dimensions 82 36 68mm 82 72 68mm
Weight 120g 250g
Standards EN 60255-1,IEC60947-5-1

Wiring Diagram
2P 4P

CMV8.63U CMV8.63D CMV8.63U CMV8.63D


N 1 N 2 N 1 3 5 N 2 4 6

N 2 N 1 N 2 4 6 N 1 3 5

73
www.fmfelectric.com
CM
Voltage Protector

Standard: IEC 60255-1


IEC60947-5-1

Functions Diagram

U
LED:Un
LED: Fault(>U)
LED: Fault(<U)
Ts Power-up delay
Ts Tt Tr Tt Tr <Tt <Tt Tt Action delay time
11-14 Tr Reset delay time

Dimensions (mm)

N N
N 2 N 2 4 6

CMV8 N 1 CMV8 N 1 3 5

40A 63A
>U:265V 3V >U:265V 3V
Un Un

82
<U:175V 2V <U:175V 2V

Tripping time delay:1s Tripping time delay:1s

Power on delay:2s Power on delay:2s


Reset delay:30s Reset delay:30s

Fault Fault
>U: >U:

<U: <U:

N IN N IN

36max 72max 67.5

Example

AC220V
N L

N
N 2

C63 ON 1 3 C25 ON 1 3 C16 ON 1 C16 ON 1


400V~
OFF
CMV8 N 1
400V~
OFF
230V~
OFF
230V~
OFF
3000 2 4 63A 3000 2 4 3000 2 3000 2
IEC 60898-1 IEC 60898-1 IEC 60898-1 IEC 60898-1
>U:265V 3V
Un
<U:175V 2V

Tripping time delay:1s

Power on delay:2s
Reset delay:30s

Fault
>U:

<U:

N IN

LOAD LOAD LOAD

74
www.fmfelectric.com
Distribution

Distribution Sub-Index
DB1 - Distribution Box IP30..................................................................... 76
DB2 - Distribution Box IP40 .................................................................... 77
DB4 - Distribution Box IP65..................................................................... 79
DB7 - Distribution Box Steel....................................................................80
B - Terminal Block ..................................................................................81
BD - Terminal Box.....................................................................................94
PG - Waterproof Connector..................................................................96
DB1
Distribution box

Standard: IEC 60439-3

DB11P
DB12P
DB14P
DB16P
DB18P
DB112P
DB118P

76
www.fmfelectric.com
DB2
Distribution box

Standard: IEC 62208

DB2S2 DB2S2V
DB2S3 DB2S3V
DB2S4 DB2S4V
DB2S6 DB2S6V
DB2S8 DB2S8V
DB2S10 DB2S10V
DB2S12 DB2S12V
DB2S15 DB2S15V
DB2S18 DB2S18V
DB2S24 DB2S24V
DB2S36 DB2S36V

DB2F2 DB2F2V
DB2F3 DB2F3V
DB2F4 DB2F4V
DB2F6 DB2F6V
DB2F8 DB2F8V
DB2F10 DB2F10V
DB2F12 DB2F12V
DB2F15 DB2F15V
DB2F18 DB2F18V
DB2F24 DB2F24V
DB2F36 DB2F36V

77
www.fmfelectric.com
DB2
Distribution Box

Standard: IEC 62208

DB2S4T2 DB2S4VT2

DB2S6T2 DB2S6VT2

DB2S8T2 DB2S8VT2

DB2S12T2 DB2S12VT2

DB2S18T2 DB2S18VT2

DB2S24T2 DB2S24VT2

DB2S36T2 DB2S36VT2

DB2F4T2 DB2F4VT2

DB2F6T2 DB2F6VT2

DB2F8T2 DB2F8VT2

DB2F12T2 DB2F12VT2

DB2S18T2 DB2F18VT2

DB2F24T2 DB2F24VT2

DB2F36T2 DB2F36VT2

78
www.fmfelectric.com
DB4
Distribution Box

Standard: IEC 62208

DB4P4R
DB4P6R
DB4P8R
DB4P9R
DB4P12R
DB4P18R
DB4P24R

DB4P4RT
DB4P6RT
DB4P8RT
DB4P9RT
DB4P12RT
DB4P18RT
DB4P24RT

79
www.fmfelectric.com
DB7
Distribution Box

Standard: IEC 62208

DB7113
DB7226
DB7339
DB7452
DB7118
DB7236
DB7354
DB7472
DB7690
DB7122
DB7244
DB7366
DB7488
DB75110

80
www.fmfelectric.com
B
Universal Terminal Block

81
www.fmfelectric.com
B
Universal Terminal Block

82
www.fmfelectric.com
B
Universal Terminal Block

83
www.fmfelectric.com
B
High Current Terminal Block

84
www.fmfelectric.com
B
Ground Terminal Block

85
www.fmfelectric.com
B
Ground Terminal Block

86
www.fmfelectric.com
B
GroundTerminal Block

87
www.fmfelectric.com
B
Universal Terminal Block

88
www.fmfelectric.com
B
Universal Terminal Block

89
www.fmfelectric.com
B
Universal Terminal Block

90
www.fmfelectric.com
B
Universal Terminal Block

91
www.fmfelectric.com
B
Universal Terminal Block

92
www.fmfelectric.com
B
Universal Terminal Block

93
www.fmfelectric.com
BD
Terminal Box

94
www.fmfelectric.com
BD
Terminal Box

95
www.fmfelectric.com
PG
Waterproof Connector

96
www.fmfelectric.com
PG
Waterproof Connector

97
www.fmfelectric.com
Notes

98
www.fmfelectric.com
Climate Control

Climate Control Sub-Index


CL.T - Small Compact Thermostat ................................................... 100
CL.TH - Mechanical / Electronic Hygrostat .......................................101
CL.R - Heaters......................................................................................... 103
CL.V - Fun filters..................................................................................... 108
CL.I - LED Lamp .....................................................................................114
CL.A - Accesories ....................................................................................116
CL.T
Small Compact Thermostat - Regulating

TC / TR

Thermostat (normally closed); contact breaker for regulating heaters. The contact opens when
temperature is rising.

Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or for
switching signal devises when temperature limit has been exceeded. The contact closes when
temperature is rising.

Technical Data
TC / TR
Switch temperature difference +/-5°C
Sensor element thermostatic bimetal
Contact type snap-action contact
Service life >100,000 cycles

F Type Max. switching capacity 250VAC, 10 (2) A / 120VAC, 15 (2) A


DC 30W at 24VDC to 72VDC
33 Max. inrush current AC 16A for 10 sec.
Connection 2-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2
(AWG 14) stranded wire1 1.5mm2 (AWG 16)
Mounting clip for 35mm DIN rail, EN 60715
Casing plastic according to UL94 V-0, light grey
Dimensions 60 x 33 x 43mm
43 Weight approx. 40g
Fitting position variable
Operating/Storage temperature -45 to +80°C (-49 to +176°F)
Operating/Storage humidity max. 90% RH (non-condensing)
Protection type IP20
60

¹ When connecting with wires, wire end ferrules must be used.


Important note: The contact system of the regulator is subjected to environmental influences, thus the
contact resistance may change. This can lead to a voltage drop and/or self-heating of the contacts.

Connection diagrams Examples of connection


Thermostat Thermostat
CL.TC (NC) CL.TR (NO) Thermostat Heater Thermostat e.g. Fan Thermostat e.g. Signal
TC (NC) TR (NO) TR (NO) device

LN

Fast Fixing Type (F Type)


Setting range
TC (NC Type) TR (NO Type)
CL.TC.+0060C CL.TR.+0060C 0 to +60°C
Heater CL.TC.-1050C CL.TR.+0060C -10 to +50°C
CL.TC.+2080C CL.TR.+2080C +20 to +80°C
Filter fan, Cooling equipment, Signal device
CL.TC.+32140F CL.TR.+32140F +32 to +140°F
CL.TC.+14122F CL.TR.+14122F +14 to +122°F

100
www.fmfelectric.com
CL.TH
Mechanical Hygrostat - Regulating

Standard: IEC 60898-1

TH

The electromechanical hygrostat is designed to control enclosure heaters so that the dew point is raised
when a critical relative humidity of 65% is exceeded. In this way condensation and corrosion in
enclosures with electric/electronic components is effectively prevented.

Technical Data
TH
Switch difference¹ +/-5% RH
Permissible air velocity 15m/sec.
Contact type change-over contact
Service life >50,000 cycles
Min. switching capacity 20VAC / DC 100mA
Max. switching capacity 250VAC, 5A / DC 20W
Connection 3-pole terminal for 2.5mm², clamping torque 0.5Nm max.:
50
rigid wire 2.5mm² (AWG 14); stranded wire² 1.5mm² (AWG 16)
Mounting clip for 35mm DIN rail, EN 60715
Casing plastic according to UL94 V-0, light grey
Dimensions 67 x 50 x 38mm
38 Weight approx. 60g
Fitting position variable
Operating/Storage temperature 0 to +60°C (+32 to +140°F) / -40 to +60°C (-40 to +140°F)
Operating/Storage humidity max. 95% RH (non-condensing)
67

Protection type IP20

¹ at 50% RH
² When connecting with stranded wires, wire end ferrules must be used.

Connection diagrams Examples of connection


Heater Hygrostat Hygrostat e.g. Filter fan
TH TH

LN

Art. No. Setting Range Operating Voltage


Heater CL.TH.3595 35 to 95% RH 20VAC/DC, 250VAC

Filter fan, Cooling equipment, Signal device

101
www.fmfelectric.com
CL.TH
Electronic Hygrostat - Regulating

Standard: IEC 60898-1

TH

The electronic hygrostat is designed to control enclosure heaters so that the dew point is raised when a
critical relative humidity of 65% is exceeded. In this way condensation and corrosion in enclosures
with electric/electronic components is effectively prevented.

Technical Data
TH
Switch difference 5% RH (±3% RH tolerance) at +25°C (+77°F), 50% RH
Reaction time 5 sec.
Contact type change-over contact (relay)
Service life >50,000 cycles
Max. switching capacity (relay output) 240VAC / 120VAC 8 (1.6) A
42.5 Max. inrush current AC 16A for 10 sec.
Optical Indicator LED
Connection1 5-pole terminal, clamping torque 0.5Nm max.:
rigid/stranded wire 2.5mm² (AWG 14);
38

Mounting clip for 35mm DIN rail, EN 60715


Casing plastic according to UL94 V-0, light grey
Dimensions 64.5 x 42.5 x 38mm

50
60 70

80
Weight approx. 70g
40 90
%rF/RH
Fitting position variable
Operating/Storage temperature 0 to +60°C (+32 to +140°F) / -20 to +70°C (-4 to +158°F)
64.5

Operating/Storage humidity max. 90% RH (non-condensing)


Protection type IP20
1
When connecting with stranded wires, wire end ferrules must be used.

Connection diagrams Examples of connection


Heater
Hygrostat TH
TH

60 70

50 80

40 90
%rF/RH

1 2 4 5 LN

Art. No. Setting Range Operating Voltage


Heater CL.TH.3595.E230 40 to 90% RH 230VAC, 50/60Hz
CL.TH.3595.E120 40 to 90% RH 120VAC, 50/60Hz
Filter fan, Cooling equipment, Signal device

102
www.fmfelectric.com
CL.R
Semiconductor Heater - Heating

Standard: IEC 60898-1

RC1 / 15W to 150W

These heaters are used in enclosures where damage from condensation must be prevented, or where
the temperature may not fall below a minimum value. The aluminium profile heater body design has a
chimney effect and distributes the heat evently. The heaters are designed for permanent operation.
Pressure clamb connectors save time and simplify installation.

Technical Data
RC1
Operating voltage 120-260V AC/DC or 12V DC or 24V DC or 48V DC¹ (min. 110 V, max. 265 V)
Heating element PTC resistor - temperature limiting
Heater body extruded aluminium profile, anodised
Connection 3 pressure clamps for stranded wire 0.5-1.5mm² (with wire end
ferrule) and rigid wire 0.5- 2.5mm²
Connection casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 60715
Fitting position vertical airflow (air outlet up, connection on bottom)
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Operating/Storage humidity max. 90% RH (non-condensing)
Protection type/Protection class IP20 / I (earthed)
Accessoires screw fixing
Note other voltages on request

¹ Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.

Example of connection

Heater RC1

Thermostat TC

30
20 40
61±0.5 10 50
0 60 °C
56±0.5
64±0.5

Art. No. Heating capacity2 Length (L) Weight (approx.)


CL.RC1.15W 15W 65mm 0.25kg
35
L

CL.RC1.30W 30W 65mm 0.25kg


CL.RC1.45W 45W 65mm 0.25kg
CL.RC1.50W 50W 80mm 0.35kg
CL.RC1.60W 60W 140mm 0.35kg
CL.RC1.75W 75W 140mm 0.45kg
32

CL.RC1.100W 100W 140mm 0.45kg


58 21.5 CL.RC1.150W 150W 220mm 0.65kg
2
at +20°C (+68°F) ambient temperature

103
www.fmfelectric.com
CL.R
Touch-Safe Small Heater (Semiconductor) - Heating

RC2 / 10W, 20W, 30W

The heaters are used in enclosures where condensation is to be prevented or the temperature may
not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured.
The heaters are designed for permanent operation.

Technical Data
RC2
Operating voltage 120-260V AC/DC¹ (min. 110V, max. 265V)
Heating element PTC resistor - temperature limiting
Surface temperature < +85°C (+185°F) (according to VDE 0100), except upper protective
Fast Fixing Part grille
Connection 2-pole terminal 2.5mm², torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 60715
Fitting position vertical airflow (air outlet up, connection on bottom)
Operating/Storage temperature -45°C to +70°C (-49°F to +158°F)
Operating/Storage humidity max. 90% RH (non-condensing)
Protection type/Protection class IP20 / II (double insulated)
Note other voltages on request

38.38 ¹ Operating with voltages below 140V AC/DC reduces heating performance by approx 10%.

Examples of connection
75.85

Heater RC2
10.08

Thermostat
TC

38.37 75.85
30
20 40
10 50
0 60 °C
107.55
98.59

L
N

10.08 24.70
Art. No. Heating capacity² Dimensions Weight (approx.)
69.09
CL.RC2.10W 10W 96 x 38 x 79mm 0.2kg
CL.RC2.20W 20W 96 x 38 x 79mm 0.3kg
CL.RC2.30W 30W 96 x 38 x 79mm 0.3kg

² at +20°C (+68°F) ambient temperature

104
www.fmfelectric.com
CL.R
Touch-Safe Heater (semiconductor) with Fast Fixing part - Heating

RC2 / 50W to 150W

Touch-safe heater for the use in enclosures with electrical/electronical components. The design of the
heater supports the natural convection which results in a high air-current of warm air. The surface
temperatures on the accessible side surfaces of the housing are kept down as a result of the heater
design. Our complete range of thermostats and hygrostats can directly be connected to the heater
RC2. This heater is also available in a version with plug-in thermostat requiring no additional wiring.
The heaters are designed for permanent operation.

Technical Data
RC2
Operating voltage 120-260V AC/DC¹ (min. 110V, max. 265V)
Fast Fixing Part
Heating element PTC resistor - temperature limiting
Surface temperature < +80°C (+176°F), except upper protective grille
Connection 4-pole terminal 2.5mm², torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 60715
Fitting position vertical airflow (air outlet up, connection on bottom)
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Operating/Storage humidity max. 90% RH (non-condensing)
Protection type/Protection class IP20 / II (double insulated)
Note other voltages on request

¹ Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.

Examples of connection

Heater RC2

Thermostat
60

TC

30
20 40
10 50
0 60 °C
90

AC L
N
L

Art. No. Heating capacity² Air outlet temperature³ Dimensions Weight (approx.)
CL.RC2.50W 50W +86°C (+186.8°F) 110 x 60 x 90mm 0.3kg
CL.RC2.100W 100W +120°C (+248°F) 150 x 60 x 90mm 0.4kg
CL.RC2.150W 150W +145°C (+293°F) 150 x 60 x 90mm 0.4kg

² ambient temperature - see Heating capacity / Ambient temperature diagram;


³ measured 50mm above protective grille

105
www.fmfelectric.com
CL.R
Touch-Safe Heater (semiconductor) with Fast Fixing part - Heating

RC3 / 150W to 400W

Fan heater prevents formation of condensation and provides an evently distributed interior air
temperature in enclousures with electric/electronic components. The heater is connected using the
internal terminal connectors. The small size of the RC3 makes it ideal for use in enclousures where
space is at a premium.

Technical Data
RC3
Operating voltage 120V AC or 230V AC or 120 & 230V AC
Heating element PTC resistor - temperature limiting
Surface temperature 150W/250W: max +50°C (+122°F), 400W: max +65°C (+149°F)
each except upper protective grille at +20°C (+68°F) ambient temp.
Axial fan, ball bearing air flow, free flow
45m3/h (230VAC), 54m3/h (120VAC)
service life 40.000h at +40°C (+104°F)
Connection 2-pole clamp max 2.5mm², clamping screw
torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 60715 or screw fixing (Ø5.3mm)
Fitting position vertical airflow (air outlet up)
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Operating/Storage humidity max. 90% RH (non-condensing)
Protection type/Protection class IP20 / II (double insulated)
Note other voltages on request

Examples of connection

Heater RC3 Heating capacity / Ambient temperature diagram


RC3
Thermostat TC
Heating capacity (W)

30
20 40
10 50
0 60 °C

L
N Temperature (°C)

Art. No. Heating capacity Operating voltage Dimensions Weight (approx.)


90.80

CL.RC3.150W2 150W 230VAC, 50/60Hz 75 x 65 x 90mm 0.3kg


CL.RC3.250W2 250W 230VAC, 50/60Hz 90 x 85 x 111mm 0.5kg
85.50
CL.RC3.400W2 400W 230VAC, 50/60Hz 90 x 85 x 111mm 0.5kg
CL.RC3.150W1 150W 120VAC, 50/60Hz 75 x 65 x 90mm 0.3kg
85.50

CL.RC3.250W1 250W 120VAC, 50/60Hz 90 x 85 x 111mm 0.5kg


CL.RC3.400W1 400W 120VAC, 50/60Hz 90 x 85 x 111mm 0.5kg

106
www.fmfelectric.com
CL.R
Touch-Safe Heater (semiconductor) with Fast Fixing part - Heating

RC4 / 800W to 1200W

The compact high performance fan heater prevents formation of condensation and frost and provides
an evently distributed interior air temperature in enclousures with electric/electronic components. The
plastic housting provides double insulation and acts as protection against contact. The fan heater is
available with integrated thermostat for temperature control. The RC4 was designed as a stationary unit
for wall fixing. For fixing on the bottom of the enclousure the fan heater RC4 is recommended.

Technical Data
RC4
Heating element PTC resistor - temperature limiting
Temperature safety cut-out to protect against overheating in case of fan failure, automatic reset
Axial fan, ball bearing air flow 160m3/h, free flow
service life 50.000h at +25°C (+77°F)
Connection 2-pole max. 2.5mm2, clamping screw with strain relief,
torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 60715 or screw fixing (M6)
Fitting position vertical airflow (air outlet up) - other fitting positions possible
Dimensions 182 x 160 x 120mm
Weight approx. 1.3kg
Operating/Storage temperature -45 to +70°C (-49 to +158°F)
Operating/Storage humidity max. 90% RH (non-condensing)
Protection type/Protection class IP20 / II (double insulated)

Examples of connection

CL.RC4.800W 230VAC, 50/60Hz 800W 0 to +60°C


CL.RC4.900W 230VAC, 50/60Hz 900W 0 to +60°C
CL.RC4.1000W 230VAC, 50/60Hz 1000W 0 to +60°C
CL.RC4.1200W 230VAC, 50/60Hz 1200W 0 to +60°C
CL.RC4.800W 120VAC, 50/60Hz 800W +32 to +140°F
CL.RC4.900W 120VAC, 50/60Hz 900W +32 to +140°F
CL.RC4.1000W 120VAC, 50/60Hz 1000W +32 to +140°F
CL.RC4.1200W 120VAC, 50/60Hz 1200W +32 to +140°F

107
www.fmfelectric.com
CL.V
Fan Filter IP54 - Buckle Lock Door Type - Ventilating

VF.120: Exit Filter


VCF.120: Filter Fan

Fan filters are used to provide an optimum climate in enclousures and cabinets with electrical/electronic
components. The interior temperature of an enclousure can be reduced by channelling cooler filtered
outside air into the enclousure thus expelling heated internal air. The resulting airflow prevents formation
of localised hot pockets in installations and protects electronic components from overheating.

The Fan filter series uses a new air-flap outlet technology for the air outlet and thus reaches a high degree
of airflow. A ratchet mechanism is used for mounting and provides high stability and tightness. It is a
standard installation with a filter fan in the lower part of the enclousure which ensures that fresh air is out
of the enclousure (airflow direction “OUT”).
This system consists of a filter fan and exit filter.

26.1 50

Technical Data
VCF.120
Axial fan, ball bearing service life L10 at +40°C (+104°F): min. 50,000h
92.7
80

fan body aluminium, rotor metal


Connection 2 stranded wires, 300mm
Casing, hood, flaps New ABS confirm to RoHS
21.21 Enclosure cut-out 93 x 93+1mm
Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness
120
1-4mm). Additional use of screws possible if needed1
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material synthetic fibre with progressive construction, temperature resistant to
+100°C, self-extinguishing class F1,moisture resistant to 100% RH, reusable
119.78

Operating/Storage temperature -40 to +70°C (-40 to +158°F)


Operating/Storage humidity max. 90% RH (non-condensing)
Protection type/Protection class IP54 / I (earthed)
Note other voltages on request

115.6 ¹ Drilling marks for screw mounting are indicated on mounting frame.

Airflow Direction “OUT”: Fan Filter VCF.120


114.5

Art. No. Operating Air volume, Air volume Power Weight


voltage free flow with exit filter consumption (approx.)
CL.VCF.120.230 AC 230V, 50/60Hz 19m³/h 13m³/h 12W 0.6kg
CL.VCF.120.120 AC 110V, 50/60Hz 23m³/h 16m³/h 11W 0.6kg

93
Exit Filter VF.120
Art. No. Operating Air outlet Depth in Weight
voltage enclousure (approx.)
CL.VF.120 - air-flap outlet technology 29mm 0.2kg
93

Note: We can offer 230VAC, 110VAC, 24VDC, 12VDC, 400VAC, 120&230VAC Fan Filter, for more Art No.
here not show.
Enclosure cut-out Please inquiry to us by email, we will offer to you by email: info@fmfelectric.com .

108
www.fmfelectric.com
CL.V
Fan Filter IP54 - Buckle Lock Door Type - Ventilating

VF.152: Exit Filter


VCF.152: Filter Fan

Fan filters are used to provide an optimum climate in enclosures and cabinets with electrical/electronic
components. The interior temperature of an enclosure can be reduced by channelling coller filtered
outside air into the enclosure thus expelling heated internal air. The resulting airflow prevents formation
of localised hot pockets in installation and protects electronic components from overheating.

The Fan filter series uses a new air-flap outlet technology for the air outlet and thus reaches a high
degree of airflow. A ratche mechanism is used for mounting and provides high stability and tightness. It
is a standard installation with a filter fan in the lower part of the enclosure which ensures that fresh air is
out of the enclosure (airflow direction “OUT”). This system consists of a filter fan and exit filter.
26.1 50

Technical Data
120

VCF.152
Axial fan, ball bearing service life L10 at +40 °C (+104 °F): min. 37,000 h
fan body aluminium, rotor metal
Connection 2 stranded wires, 160mm
20.97
Casing, hood, flaps New ABS confirm to RoHS
151.4
Enclosure cut-out 125 x 125+1 mm
Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness
1-4mm). Additional use of screws possible if needed1
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material synthetic fibre with progressive construction, temperature resistant to
152.03

+100°C, self-extinguishing class F1, moisture resistant to 100% RH, reusable


Operating/Storage temperature -40 to +70°C (-40 to +158°F)
Operating/Storage humidity max. 90% RH (non-condensing)
Protection type/Protection class IP54 / I (earthed)

147
Note other voltages on request

¹ Drilling marks for screw mounting are indicated on mounting frame.


146.5

Airflow Direction “OUT”: Fan Filter VCF.152


Art. No. Operating Air volume, Air volume Power Weight
voltage free flow with exit filter consumption (approx.)
CL.VCF.152.230 AC 230V, 50/60Hz 52m³/h 42m³/h 19W 0.8kg
CL.VCF.152.120 AC 110V, 50/60Hz 62m³/h 51m³/h 18W 0.8kg
125

Exit Filter VF.152


Art. No. Operating Air outlet Depth in Weight
voltage enclousure (approx.)
125

CL.VF.152 - air-flap outlet technology 35mm 0.3kg

Note: We can offer 230VAC, 110VAC, 24VDC, 12VDC, 400VAC, 120&230VAC Fan Filter, for more Art No.
here not show.
Please inquiry to us by email, we will offer to you by email: info@fmfelectric.com .
Enclosure cut-out

109
www.fmfelectric.com
CL.V
Fan Filter IP54 - Buckle Lock Door Type - Ventilating

VF.204: Exit Filter


VCF.204: Filter Fan

Fan filters are used to provide an optimum climate in enclosures and cabinets with electrical/electronic
components. The interior temperature of an enclosure can be reduced by channelling coller filtered
outside air into the enclosure thus expelling heated internal air. The resulting airflow prevents formation
of localised hot pockets in installations and protects electronic components from overheating.

The Fan filter series uses a new air-flap outlet technology for the air outlet and thus reaches a high
degree of airflow. A ratchet mechanism is used for mounting and provides high stability and tightness. It
is a standard installation with a filter fan in the lower part of the enclosure which ensures that fresh air is
out of the enclosure (airflow direction “OUT”). This system consists of a filter fan and exit filter.

44.5 50

Technical Data
117.84
120

VCF.204
Axial fan, ball bearing service life L10 at +40 °C (+104 °F): min. 65,000 h
fan body aluminium, rotor metal
Connection 3 pole clamp for 2.5mm2, clamping torque 0.8Nm max.
23.09
Casing, hood, flaps New ABS confirm to RoHS
203.5
Enclosure cut-out 177 x 177+1 mm
Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness
1-4mm). Additional use of screws possible if needed1
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material synthetic fibre with progressive construction, temperature resistant to
203.5

+100°C, self-extinguishing class F1, moisture resistant to 100% RH, reusable


Operating temperature 50 Hz: -25 to +50°C (-13 to +122°F)
60 Hz: -25 to +70°C (-13 to +158°F)
Storage temperature -40 to +70°C (-40 to +158°F)
Operating/Storage humidity max. 90% RH (non-condensing)
199.1
Protection type/Protection class IP54 / I (earthed)
Note other voltages on request

¹ Drilling marks for screw mounting are indicated on mounting frame.


198.63

Airflow Direction “OUT”: Fan Filter VCF.204


Art. No. Operating Air volume, Air volume Power Weight
voltage free flow with exit filter consumption (approx.)
CL.VCF.204.230 AC 230V, 50/60Hz 170m³/h 123m³/h 45W 1.6kg
CL.VCF.204.120 AC 110V, 50/60Hz 204m³/h 187m³/h 38W 1.6kg
177

Exit Filter VF.204


Art. No. Operating Air outlet Depth in Weight
voltage enclousure (approx.)
177

CL.VF.204 - air-flap outlet technology 43mm 0.4kg

Note: We can offer 230VAC, 110VAC, 24VDC, 12VDC, 400VAC, 120&230VAC Fan Filter, for more Art No.
here not show.
Please inquiry to us by email, we will offer to you by email: info@fmfelectric.com .
Enclosure cut-out

110
www.fmfelectric.com
CL.V
Fan Filter IP54 - Buckle Lock Door Type - Ventilating

VF.255: Exit Filter


VCF.255: Filter Fan

Fan filters are used to provide an optimum climate in enclosures and cabinets with electrical/electronic
components. The interior temperature of an enclosure can be reduced by channelling coller filtered
outside air into the enclosure thus expelling internal air. The resulting airflow prevents formation of
localised hot pockets in installation and protects electronic components from overheating.

The Fan filter series uses a new air-flap outlet technology for the air outlet and thus reaches a high
degree of airflow. A ratche mechanism is used for mounting and provides high stability and tightness. It
is a standard installation with a filter fan in the lower part of the enclosure which ensures that fresh air is
out of the enclosure (airflow direction “OUT”). This system consists of a filter fan and exit filter.

49.5 53

Technical Data
VCF.255
Axial fan, ball bearing service life L10 at +40 °C (+104 °F): min. 56,000 h
rotor metal
Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max.
23.5 Casing, hood, flaps New ABS confirm to RoHS
254.5
Enclosure cut-out 230 x 230+1 mm
Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness
1-4mm). Additional use of screws possible if needed1
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material synthetic fibre with progressive construction, temperature resistant to
254.5

+100°C, self-extinguishing class F1, moisture resistant to 100% RH, reusable


Operating temperature -25 to +65°C (-13 to +149°F)
Storage humidity -40 to +70°C (-40 to +158°F)
Operating/Storage humidity max. 75% RH (non-condensing)
250.1 Protection type/Protection class IP54 / I (earthed)
Note other voltages on request

¹ Drilling marks for screw mounting are indicated on mounting frame.


249.21

Airflow Direction “OUT”: Fan Filter VCF.255


Art. No. Operating Air volume, Air volume Power Weight
voltage free flow with exit filter consumption (approx.)
CL.VCF.255.230 AC 230V, 50/60Hz 305m³/h 210m³/h 64W 2.4kg
230 CL.VCF.255.120 AC 110V, 50/60Hz 332m³/h 293m³/h 81W 2.4kg

Exit Filter VF.255


Art. No. Operating Air outlet Depth in Weight
voltage enclousure (approx.)
230

CL.VF.255 - air-flap outlet technology 46mm 0.6kg

Note: We can offer 230VAC, 110VAC, 24VDC, 12VDC, 400VAC, 120&230VAC Fan Filter, for more Art No.
here not show.
Please inquiry to us by email, we will offer to you by email: info@fmfelectric.com .
Enclosure cut-out

111
www.fmfelectric.com
CL.V
Fan Filter IP54 - Buckle Lock Door Type - Ventilating

VF.323: Exit Filter


VCF.323: Filter Fan

Fan filters are used to provide an optimum climate in enclosures and cabinets with electrical/electronic
components. The interior temperature of an enclosure can be reduced by channelling coller filtered
outside air into the enclosure thus expelling internal air. The resulting airflow prevents formation of
localised hot pockets in installation and protects electronic components from overheating.

The Fan filter series uses a new air-flap outlet technology for the air outlet and thus reaches a high
degree of airflow. A ratche mechanism is used for mounting and provides high stability and tightness. It
is a standard installation with a filter fan in the lower part of the enclosure which ensures that fresh air is
out of the enclosure (airflow direction “OUT”). This system consists of a filter fan and exit filter.

49.5 53

Technical Data
VCF.323
Axial fan, ball bearing service life L10 at +40 °C (+104 °F): min. 65,000 h
fan body aluminium, rotor metal
Connection 3 pole clamp for 2.5mm2, clamping torque 0.8Nm max.
Casing, hood, flaps New ABS confirm to RoHS
23.5

323 Enclosure cut-out 298 x 298 +1 mm


Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness
1-4mm). Additional use of screws possible if needed1
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material synthetic fibre with progressive construction, temperature resistant to
+100°C, self-extinguishing class F1, moisture resistant to 100% RH, reusable
323

Operating temperature 50 Hz: -25 to +55°C (-13 to +131°F)


60 Hz: -25 to +35°C (-13 to +95°F)
Storage temperature -40 to +70°C (-40 to +158°F)
Operating/Storage humidity max. 75% RH (non-condensing)
318.1
Protection type/Protection class IP54 / I (earthed)
Note other voltages on request

¹ Drilling marks for screw mounting are indicated on mounting frame.


317.2

Airflow Direction “OUT”: Fan Filter VCF.323


Art. No. Operating Air volume, Air volume Power Weight
voltage free flow with exit filter consumption (approx.)
CL.VCF.323.230 AC 230V, 50/60Hz 433m³/h 373m³/h 95W 3.1kg
CL.VCF.323.120 AC 110V, 50/60Hz 394m³/h 339m³/h 90W 3.1kg
298

Exit Filter VF.323


Art. No. Operating Air outlet Depth in Weight
voltage enclousure (approx.)
298

CL.VF.323 - air-flap outlet technology 50mm 1.0kg

Note: We can offer 230VAC, 110VAC, 24VDC, 12VDC, 400VAC, 120&230VAC Fan Filter, for more Art No.
here not show.
Please inquiry to us by email, we will offer to you by email: info@fmfelectric.com .
Enclosure cut-out

112
www.fmfelectric.com
CL.V
Fan Filter IP55 - Roof fan - Ventilating

VF.323: Exit Filter Product Applications


VCF.323: Filter Fan Out products are widely used in the control panels, junction boxes, power distribution box,
automation equipment, electronic and power device, welding machine, packing, etc

Normal color: RAL 7035, RAL 7032

Technical Data
VCF.323
Axial fan, ball bearing service life L10 at +40 °C (+104 °F): min. 50,000 h rotor metal
Connection 3 pole clamp for 2.5mm2, clamping torque 0.8Nm max.
Dimensions 400x135x400 mm
Enclosure cut-out 258 x 258+1 mm
Centrifugal Fan Capacitive motor
Filter mat G4
Filter material ABS
Operating temperature 50 Hz: -25 to +55°C (-13 to +131°F); 60 Hz: -25 to +35°C (-13 to +95°F)
Storage temperature -40 to +70°C (-40 to +158°F)
Operating/Storage humidity max. 75% RH (non-condensing)
Protection type/Protection class without filter mat: IP22, with filter mat: IP55

399.00

Technical Parameters

Model Power Air Flow Rate Air Flow Rate Power Current Noise
Supply (free blow) (free blow) Consumption Consumption Level
No filter mat (m3/h) With filter mat (m3/h) (W) (A) (dBA)
CL.VCF.T.230A 230VAC 570/620 430/465 60/71 0.28/0.31 71
CL.VCF.T.230B 230VAC 860/900 675/702 98/118 0.46/0.51 74
396.00

CL.VCF.T.230C 230VAC 1200/1340 870/960 130/170 0.60/0.74 71


CL.VCF.T.115 115VAC 1200/1340 870/960 130/171 1.30/1.45 71
CL.VCF.T.380A 380VAC 570/620 430/465 60/71 0.28/0.31 71
CL.VCF.T.380B 380VAC 860/900 675/702 98/118 0.46/0.51 74
CL.VCF.T.380C 380VAC 1200/1340 870/960 130/170 0.60/0.74 71
130.00
61.70

Enclosure cut-out

113
www.fmfelectric.com
CL.I
Lamp - Accesories

LED 025

The lamp series LED 025 is suitable for all types of panels and enclosures, especially where space
is at a premium. The lamps have a very long service life thanks to the use of LED technology. Three
different fixing options provide more flexibility for installation. The power output allowsup to 10
lamps to be connected to each other (12VDC versions up to 5 lamps). Both the power input and
output connectors snap lock into their sockets. With the integrated power unit and the plugs the lamp
con quickly be connected.

Technical Data
LED 025
Power consumption max. 5W
Luminosity 400Lm at 120° (1,200Lm at 360° or equivalent 95W light bulb)
Lamp type LED, angle of radiation 120°
light color: daylight, color temperature: 6,000K to 7,000K
Service life 60,000h at +20°C (+68°F)
Connection 2-pole connector with snap lock
AC: max. 2.5A / 240VAC, color: white
DC: max. 2.5A / 60VDC, color: blue
Mounting magnet fixing or screw fixing (M5), clip fixing (M6),
torque 2Nm max.
Casing plastic, transparent
Dimensions see drawings
Weight 0.2kg
Operating/Storage temperature -30 to +60°C (-22 to +140°F) / -40 to +85°C (-40 to +185°F)
Operating/Storage humidty max. 90% RH (non-condensing)
Protection type/Protection class IP20 / II (double insulated)

Mounting options: The lamps are available with magnet fixing for easy positioning in any steel
cabinet or enclosure. A classic is the LED025 with screw fixing. The clip holders exclusively designed
for clip fixing of the LED025 can be positioned anywhere in the cabinet by simply screwing the holders
to the cabinet wall. The lamp is snapped into the clip holders and can be turned in both directions.
With a total rotation angle of 180° it provides perfect illumination within the cabinet or enclosure.

Note: The lamp must not be used for household lighting.


351

250

351

325

ĭ2 ĭ32 ĭ32 ĭ32 ĭ32 ĭ32


9.75 9.75
39

47.3
41
34

36

42

52 52
40 40

Art. No. Fixing type Switch Operating voltage


CL.ILED.025 Magnet fixing on/off light switch 100-240VAC, 50/60Hz (min. 65VAC, max. 265VAC)

114
www.fmfelectric.com
CL.I
Lamp - Accesories

LED 025 ACCESSORIES


Connectors and cables for electrical connection are not included in the delivery of the LED 025. These
parts can be ordered separately. Sets, consisting of lamp and accessories, are available on request.

CONNECTION CABLE WITH FEMALE CONNECTOR AND OPEN END


Art. No. Model Length Voltage type Use for
05244356 connection cable 2 x 1.5mm² with female connector 2.0m AC power input
05244357 connection cable 2 x AWG 15 with female connector 2.0m AC power input

EXTENSION CABLE WITH 2 CONNECTORS FOR DAISY CHAIN CONNECTION


Art. No. Model Length Voltage type Use for
05244358 extension cable 2 x 1.5mm² with 2 connectors 1.0m AC daisy chain
05244359 extension cable 2 x AWG 15 with 2 connectors 1.0m AC daisy chain

FEMALE / MALE CONNECTORS


Art. No. Model Color Voltage type Use for
05264057 female connector white AC power input
05264058 male connector white AC power input

CONNECTION EXAMPLE

44 351 44

This illustration shows the LED 025 lamp in a daisy chain application. The lamps are conveniently
connected via quick connection plugs – up to 10 (5) lamps max. can be daisy-chained this way. The snap
lock connectors ensure a stable electrical connection even if subjected to heavy vibration. The connec-
tion example shows a 230VAC application, using the following cables: connection cable with female
connector, Art. No. 244356 (1); daisy chain extension cable with 2 connectors, Art. No. 244358 (2).

Female/male connectors are also available to assemble cables in non-standard lengths.

115
www.fmfelectric.com
CL.A
Door switch

CL.A.DS013 Adjustable positioning without tools


High switching capacity
Double strain relief
Different cladding diameters
Suitable for lamp LED CL.I.LED.025/C

The door switch monitors the position of cabinet doors and is available in three versions.
For example, it can be used for switching a light when opening a door (NC), or to activate a fan when
closing a door (NO). The version with change-over contact (CO) can be used as a normally closed
and/or normally open contact.
The wide mechanical adjustment range of the door switch CL.A.DS013 offers versatile application
areas: the housing is adjustable within a 35mm range, while the screw flange with a slotted hole offers
an additional 21mm. The switching travel of the switch itself is another 8mm.

Fast Wiring Connector,


just press the connector, Technical Data
then insert the cable into CL.A.DS013
the hole, no screws
Max. switching capacity 120-250VAC/DC, 15A (120V), 8A(250VAC)
needed.
Service life VDE: >10.000 cycles / UL: >6.000 cycles
Connection 4-pole clamp with strain relief, clamping torque 0.5Nm max.
Mounting screw fixing (M5)
Casing plastic according to UL94 V-0, grey/black
Dimensions 87 x 64 x 30 mm
Weight approx. 50g
Operating / Storage temperature variable
Operating / Storage humidity -20 to +85°C (-4 to +185°F)
Protection type max. 90% RH (non-condensing)

Connection Diagram

CO
NC NO
29.65

86.24 2 1 4
2 1 1
51.00
N M
N N
L
L L
49.96 63.92

Art. No. Model Suitable wire


CL.A.DS013 change-over (CO) Cable round, stranded wire (with wire end ferrule) 0.75mm² to 1mm²

116
www.fmfelectric.com
Signaling, Control & Switch

Protection Sub-Index
L05 - Led Indicator.....................118 MF - Modular contactors....................143
P05 - Pushbutton switch.......... 119 T8 - Time relays....................................146
R05 - Rotary switch .................. 130 M8 - Memory & Latching relays....... 156
HL - Changeover switch ....... 133 L8 - Level Control relays.................... 162
D2 - Isolation switch............... 134 TM - Timer relay.................................... 166
SL - Modular signal lamp ... 135 E05 - Modular socket............................ 165
MVA - Modular meters ............. 136 F8 - Light Activated Switch............... 168
EB - Modular bell ................... 138 FS - Switching Power Supply ........... 169
LR - Impulse relays................. 140
L05
LED Indicator Product Information

LED INDICATOR
Application
L05 Series indicator lights are used in the telecommunica-
tion and electrical circuit of AC 50Hz or 60 Hz, rated working
voltage 380V and below DC working voltage 220V or below
for indicator signal, accident signal, fault signal and other
indicator signals, they meet with standard: IEC60947-5-1.

Structure and function


L05 Series indicator lights adopt LED lamps with the
characteristic of long life and low energy consumption, it´s
concealed terminal is both safe and creditable.
The special locking nut structure makes the installation
available in the dimension of Ø 22.5mm to Ø 25.5mm.

118
www.fmfelectric.com
L05
LED Indicator

Standard: IEC 60898-1

06L0511

06L051213

06L051214

06L051301

06L051300

119
www.fmfelectric.com
L05
LED Indicator

Standard: IEC 60947-5-1

LED Indicator with Amper / Voltage Meter (Ø 22mm)


Description
Mini digital display voltage meter 06L052 series products two-wire three-way
AC, DC digital display voltage meter.
Ɣ Products use 2.5 inches long life LED digital tube display with compact square
enclosure, convenient installation.
Ɣ Voltage measurement range: AC 80V-500V, DC 5-120V, frequency 50/60Hz.
Ɣ Amper measurement range: AC 22V-500V, with 50, 100 and 200CT.
Ɣ Products use two wire system, AC connected in zero line and fire line directly.
Ɣ DC have polarity reverse connection protection function.

Working Condition
Ambient temperature: -10 ~ +55°c
Working pressure: 80-106KPa
Air relative humidity: 10-80% (no condensation)
Sunniness: no sunniness

Technical parameter - Amperimeter


Working voltage: 22V-500V
Working frequency: 50/60Hz
Working current: •0$
Measuring accuracy: 1.0
Measuring rate: <200MS/time
Mounting-hole size: Ø22mm

Technical parameter - Voltimeter


Working voltage: AC 80-500V, DC 8-150V
Working frequency: 50/60Hz
Working current: •0$
Measuring accuracy: 1.0
Measuring rate: <200MS/time
Mounting-hole size: Ø22mm

Style Name Type Color Voltage Outine Dimensions

ij29
White
7Max
13

Green
Ø 22
LED Voltage Meter 06L05210 Red AC80-500V
38

Yellow
Blue
ij21

ij30
White
7Max
13

Green
Ø 22
LED Voltage Meter 06L05220 Red AC80-500V
41

Yellow
Blue
ij21

120
www.fmfelectric.com
P05
Pushbutton switch

P05 series pushbutton switches are used in indus-


trial for controlling circuits of AC 50Hz or 60Hz, rated
operation voltage 380V or below and DC operational
voltage 220V or below for controlling in magnetic
starter, contactor, relay and other electrical circuits.
The buttons indicators can also be used in the place
with indicated light or signal. They meet with the
standards: IEC60947-5-1.

50 x 104

121
www.fmfelectric.com
P05
Pushbutton switch - Ø22mm

Standard: IEC 60947-5-1

122
www.fmfelectric.com
P05
Pushbutton switch - Ø22mm

Standard: IEC 60947-5-1

123
www.fmfelectric.com
P05
Pushbutton switch - Ø22mm

Standard: IEC 60947-5-1

124
www.fmfelectric.com
P05
Pushbutton switch - Ø22mm

Standard: IEC 60947-5-1

125
www.fmfelectric.com
P05
Pushbutton switch - Ø22mm

Standard: IEC 60947-5-1

126
www.fmfelectric.com
P05
Pushbutton switch - Ø22mm

Standard: IEC 60947-5-1

127
www.fmfelectric.com
P05
Pushbutton switch - Ø22mm

Standard: IEC 60947-5-1

128
www.fmfelectric.com
P05
Pushbutton Switch & Indicator - Ø22mm

Standard: IEC 60947-5-1

Indicator Description Contact Circuit Color Type Qty/Ctn

Black 06P05CB2EA121
13
N/O Green 06P05CB2EA131
11
Yellow 06P05CB2EA151
Pushbutton Blue 06P05CB2EA161 500
srping return
N/C 21
Red 06P05CB2EA142
22

Black 06P05CB2EA125
11 13 Green 06P05CB2EA135
Pushbutton
N/O+N/C 500
srping return 22 21
Red 06P05CB2EA145
Yellow 06P05CB2EA155

Black 06P05CB2EH121
13
N/O Green 06P05CB2EH131
11
Yellow 06P05CB2EH151
Pushbutton 21
N/C Red 06P05CB2EH142
Latching 22 500
11 13 Black 06P05CB2EH125
N/O+N/C
22 21 Green 06P05CB2EH135
Rec 06P05CB2EH145

129
www.fmfelectric.com
R05
Rotary switch

Standard: IEC 60947-5-1


IEC 60947-3

Introduction
The R05S26 series rotary switch mainly applies to 440V and below,
AC 50Hz or 240V and below DC circuits. For breaking and closing,
change-over of circuits under unfrequently manual operation. And
the typical applications are: control switch of 3 phase motors, control
R05S2610 switch of switchgear, control switch of instruments, and change-over
switch of machinery and welding machine.

The series comply with the IEC 60947-3, IEC 60947-5-1.


The R05S26 series have 8 current ratings: 10A, 20A, 25A, 32A, 63A,
125A, 160A and 315A.
The R05S26 series rotary switch were designed for multiple
functions, wide variety of applications.
The R05S2610, R05S2620, R05S2625, and R05S2632 have finger
R05S2620 protection terminals.
Both of them are applicable in circuits when a physical control is
required.
We can equip protective box for 20A, 25A, 32A and 63A.

Working conditions
Ambient temperature do not exceed 40°C, and the average
temperature, measures over period of 24 hours, do not exceed 35°C.
R05S2625 Ambient temperature should not be below -25°C.
Should not be installed over 2000 m above sea level.
The humidity should not exceed 50% when the ambient
temperature is 40°C, higher humidity is allowed for lower
temperature.

Installation conditions
A clean environment is requiered.
R05S2632 Please follow the instructions in the installation manual.

Classification
1. Classified by utilization
Change-over switch
Motor switch
Control switch

2. Classified by operation
Limited movement
R05S2663 Spring return
Limited movement with spring return

3. Classified by contact system


Switches with limited movement could have a maximum of: 12 layers
for 32A and bellow; 8 layers for 63A and above.
Switches with spring return could have a maximum of 3 layers.
Motor switches could have a maximum of 6 layers.

R05S26125

130
www.fmfelectric.com
R05
Rotary switch

Standard: IEC 60947-5-1


IEC 60947-3

Dimensions and installation


Square escutcheon plate and rectangular escutcheon plate

R05S26160

R05S2610 Installation R05S2620 - 315 Installation

R05S26315

R05S2610

R05S2620

R05S2625

R05S2632

R05S2663

R05S26125

R05S26160
R05S26315
Re: n for number of layers.

131
www.fmfelectric.com
R05
Rotary switch

Standard: IEC 60947-5-1


IEC 60947-3

R05S2610 R05S2620 R05S2625 R05S2632 R05S2663 R05S26125 R05S26160 R05S26315

132
www.fmfelectric.com
HL
Changeover Switch

Standard: IEC 60947-3

Changeover switch

Technical Data

Application The Changeover Swith can switch on, load and break the circuit under normal conditions, using as Switch
Disconectors.

Construction
and
Features

Electrical
Features

Circuit
Diagram

Overall and Installation Dimension (mm)

133
www.fmfelectric.com
D2
Isotation Switch

Modular Socket

Technical Data
Electrical Rated current In 32, 40, 50, 63, 80, 100, 125A
Features Poles 1P, 2P, 3P, 4P
Rated voltage Ue 240/415V~
Insulation voltage Ui 500V
Rated frequency 50/60Hz
Rated short-time withstand current Icw 12Ie,1s
Rated making and breaking capacity 3Ie, 1.05Ue, cos =0.65
Rated short circuit making capacity 20Ie, t=0.1s
Rated impulse withstand voltage (1.5/50) Uimp 4,000V
Dielectric test voltage at ind.Freq. for 1 min 2.5kV
Utilization category AC - 22A

Mechanical Electrical life 4,000 Cycles


Features Mechanical life 10,000 Cycles
Contact position indicator Yes
Protrection degree IP20

Installation Terminal connection type Cable/Pin - type busbar / U-type busbar


Terminal size top/bottom for cable 50mm2 18-2AWG
Terminal size top/bottom for busbar 50mm2 18-2AWG
Tightenig torque 3.5Nm 30In-lbs
Mounting On DIN rail EN60715 (35mm) by means of fast clip device
Connection From top and bottom

Overall and Installation Dimension (mm)


A

Side A
35

45

83

21.3

18 18
36
54 69.6
72

134
www.fmfelectric.com
SL
Modular Signal Lamp

Standard: IEC 60947-5-1

Modular Signal Lamp

Technical Data

Application The Modular Signal Lamp is applicable to circuits with rated voltage 230V~ and frequency 50/60Hz for visual
indication and signaling.

Construction
and
Features

Electrical
Features

SL1 - SL3
Signal lamp

Circuit
Diagram

Overall and Installation Dimension (mm)

136
www.fmfelectric.com
MVA
Modular meters

Standard: IEC 60051-1

Modular Voaltage Meter

MVA3 MVA1

Technical Data
MVA1
MVA3
Electrical
Features

Working
Conditions

Installation

Overall and Installation Dimension (mm)

136
www.fmfelectric.com
MVA
Modular Digital Meters

Standard: IEC 60051-1

Modular Digital Meter

Overall and Installation Dimension (mm)

137
www.fmfelectric.com
EB
Modular Electric Bell

Standard: IEC 61588-1

Bell transformer

Technical Data

Application Applicable to circuits with rated voltage 230V~ and rated frequency 50/60Hz, used to poewr electric bell of
extra low voltage.

Construction
and
Features

Electrical
Features

Overall and Installation Dimension (mm)

138
www.fmfelectric.com
EB
Modular Electric Bell

Standard: IEC 61558-1

Electric Bell

Technical Data

Application The electric bell is suitable for audible signaling for intermittent use only in domestic and commercial
installations..

Construction
and
Features

Electrical
Features

Overall and Installation Dimension (mm)

139
www.fmfelectric.com
LR
Impulse Relays

Standard: IEC 60669-2-2

Impulse Relays

Technical Data

Application The Impulse Relays are used to control, by means of pushbuttons, lighting circuits consisting of:
Ϸ Incandescent lamps, low-voltage halogen lamps, etc. (resistive loads)Rated Current In:
Ϸ Fluorescent lamps, discharge lamps, etc. (Inductive loads).

Features Ϸ Closing of the impulse relay pole(s) is triggered by an impulse on the coil.
Ϸ Having two stable mechanical positions, the pole(s) will be opened by the next impulse. Each impulse
received by the coil reverses the position of the pole(s).
Ϸ Can be controlled by an unlimited number of pushbuttons.
Ϸ Zero energy consumption.

Yellow Clip
Insulated terminals IP20.
A simple clip-on system
for flexible auxiliaries
combination and improved
robustness.
For electrical and
mechanical connections.
Built-in or optional auxiliary
function: state indication,
centralized control, latched
control, control for illuminated
pushbutton, step-by-step
control, time delay.

Manual controls on front face:


direct and prioriry manual Disconnection of remote
control by O-I toggle. control by selector switch
Mechanical contact position (except for 4P single-piece
indicator. LR16) for maintenance
operation.

Standard LR16

140
www.fmfelectric.com
LR
Impulse Realys

Standard: IEC 60669-2-2

LR16 16A

Operation

Technical
Data

141
www.fmfelectric.com
LR
Impulse Relays

Standard: IEC 60669-2-2

Technical Data

Security

Overall and Installation Dimension (mm)

142
www.fmfelectric.com
MF
Modular Contactor

Standard: IEC 61095

Automatic
type

2P/25A 4P/25A 2P/40A 4P/40A Aux

Manual
type

2P/25A 4P/25A 2P/63A 4P/63A

Technical Data
Electrical 1P, 2P 250V AC
Features Voltage rating Ue
3P, 4P 400V AC
Frequency 50/60Hz
Endurance (O-C)
Electrical life 100,000
Maximum number of switching operation a day 100
Additional characteristics
Insulation voltage Ui 500V AC
Pollution degree 2
Rated impulse withstand voltage Uimp 2.5kV (4kV @12/24/48VAC)
Degree of protection IP20
(IEC 60529) IP40
Operating temperature -5°C ~ +60°C (1)
Storage temperature -40°C ~ +70°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95% at 55°C)
ELSV compliance (Extra Low Safety Voltage) for 12/24/48VAC versions
The product control conforms to the SELV (Safety Extra Low Voltage) requirements
(1)
In the case of contactors mounting in an enclosure for which the interior temperature
is in range between 50°C and 60°C, it is necessary to use a spacer between each
contactor.

143
www.fmfelectric.com
MF
Modular Contactor

Standard: IEC 61095

Connection Copper cables


Type Rating Lenght tripping Circuit Tightening torque
Rigid Flexible or ferrule

1.5~2.5mm2 1.5~2.5mm2
16-100A Control
PZ1:4MM 9mm 0.8N.m 2x1.5mm2 2x2.5mm2
MF 16~25A 1.5~6mm2 1~4mm2
40A-63A Power 6~25mm 2
6~16mm2
PZ2:6MM 14mm 3.5N.m
2
100A 6x3.5mm 6x35mm2

± 30°

Spacer cat
IP 20 IP 40

Consumption

Contactors Rating (In) Consumption


Control voltage (VAC) (50/60Hz) Max. power
50Hz AC-7a AC-7b Holding Inrush
16A 6A 220...240 2.7VA 9.2VA 1.2W
20A 7A 220...240 2.7VA 9.2VA 1.2W
25A 9A 220...240 3.8VA 15VA 1.2W
2P 40A 18A 220...240 4.6VA 34VA 1.6W
63A 25A 220...240 4.6VA 34VA 1.6W
100A - 220...240 6.5VA 53VA 2.1W
16A 6A 220...240 4.6VA 34VA 1.6W
25A 9A 220...240 4.6VA 34VA 1.6W
32A 12A 220...240 6.5VA 53VA 2.1W
4P
40A 18A 220...240 6.5VA 53VA 2.1W
63A 25A 220...240 6.5VA 53VA 2.1W
100A - 220...240 13VA 106VA 4.2W

144
www.fmfelectric.com
MF
Modular Contactor

Standard: IEC 61095

Manual
Rating (In) Consumption
Control
Control voltage (VAC) (50/60Hz) Max. power
Contactors
AC-7a AC-7b Holding Inrush
50Hz
25A 9A 230...240 2.7VA 9.2VA 1.2W
2P 40A 18A 220...240 4.6VA 34VA 1.6W
63A 25A 220...240 4.6VA 34VA 1.6W
25A 9A 220...240 4.6VA 34VA 1.6W
4P 40A 18A 220...240 6.5VA 53VA 2.1W
63A 25A 220...240 6.5VA 53VA 2.1W

Circuit
Diagram A1 R1 R3 A1 R1 A1

A2 R2 R4 A2 R2 A2

2NC 1NC+1NO 2NO

A1 A1 R1 R3 R5 R7 A1 R1 R3 A1 R1

A2 A2 R2 R4 R6 R8 A2 R2 R4 A2 R2

4NO 4NC 2NO+2NC 3NO+1NC

Overall and Installation Dimension (mm)

66 66
49 49
18 36 5.5 36 54 5.4

81 45 85 45

4 4

MF.16/20/25A MF.32/40/63A

73 73
66 66
49 49
18 36 5.4 36 54 5.4

81 45 81 45

4 4

MF manual control contactor 16/25A MF manual control contactor 40/63A

145
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Time Relay T8 Series

Time relay is an automatic control unit, which can be


combined with various other electrical equipment to
carry out automatic control of the running circuit.
When a preset time is over, the contact output will be
closed or opened, so that the terminal electrical
equipment can run or stop automatically.

This series of time relay has the advantages of wide


operating voltage range, clear working instructions,
small volume, uniform size, easy installation, etc.

Application:
• Industrial machinery
• Illumination
• Manufacturing
• HVAC Systems
• Food and agriculture

Technical Data 06T8-541T 06T8-542T

Dimensions: in (mm) Wiring Diagrams

146
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Time Relay T8 Series

Time relay is an automatic control unit, which can be


combined with various other electrical equipment to
carry out automatic control of the running circuit.
When a preset time is over, the contact output will be
closed or opened, so that the terminal electrical
equipment can run or stop automatically.

This series of time relay has the advantages of wide


operating voltage range, clear working instructions,
small volume, uniform size, easy installation, etc.

Application:
• Industrial machinery
• Illumination
• Manufacturing
• HVAC Systems
• Food and agriculture

Technical Data 06T8-521T 06T8-522T

Dimensions: in (mm) Wiring Diagrams

147
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Time Relay T8 Series

Time relay is an automatic control unit, which can be


combined with various other electrical equipment to
carry out automatic control of the running circuit.
When a preset time is over, the contact output will be
closed or opened, so that the terminal electrical
equipment can run or stop automatically.

This series of time relay has the advantages of wide


operating voltage range, clear working instructions,
small volume, uniform size, easy installation, etc.

Application:
• Industrial machinery
• Illumination
• Manufacturing
• HVAC Systems
• Food and agriculture

Technical Data 06T8-5110 06T8-5111

Dimensions: in (mm) Wiring Diagrams

148
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Time Relay T8 Series

Time relay is an automatic control unit, which can be


combined with various other electrical equipment to
carry out automatic control of the running circuit.
When a preset time is over, the contact output will be
closed or opened, so that the terminal electrical
equipment can run or stop automatically.

This series of time relay has the advantages of wide


operating voltage range, clear working instructions,
small volume, uniform size, easy installation, etc.

Application:
• Industrial machinery
• Illumination
• Manufacturing
• HVAC Systems
• Food and agriculture

Technical Data 06T8-531T 06T8-532T

Dimensions: in (mm) Wiring Diagrams

149
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

A
On Delay Power On

B
Repeat Cycle Starting Off

C
Interval Power On

D
Off Delay S Break

E
Retriggerable One Shot

F
Repeat Cycle Starting On

G
Pulse Generator

H
One Shot

I
On/Off Delay
S Make/Break

J
Memory Latch S Make

150
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Star-delta Time Relay T8 Series

Three-phase asynchronous motor star-delta step-down


start is one of the commonmethods to solve the
excessive starting current of the motor. When the motor
is started, the stator winding is star-shaped and stepped
down to start. After the start, the stator winding is
connected into a triangle full-pressure motion.

This star type start, star-delta starting method of triangle


operation can reduce the starting current and its impact
on the power grid.

Application:
• Industrial machinery

Technical Data 06T8-522

Dimensions: in (mm) Wiring Diagrams

151
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Time Relay T8 Series

When the switch is triggered, the control contact is


closed, the lighting is on, ant the delay begins.
When the specified time is up, the control contact is
disconnected and the lighting is off.

Suitable for installation on 35mm rail (in accordance with


EN 60715 standard)

Application:
• Lighting
• Lighting control system

Technical Data 06T8-53210 06T8-53220

Dimensions: in (mm) Wiring Diagrams

152
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Time Relay T8 Series

When the switch is triggered, the control contact is


closed, the lighting is on, ant the delay begins.
When the specified time is up, the control contact is
disconnected and the lighting is off.

Suitable for installation on 35mm rail (in accordance with


EN 60715 standard)

Application:
• Lighting
• Lighting control system

Technical Data 06T8-53210 06T8-53220

Dimensions: in (mm) Wiring Diagrams

153
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Working Wiring Diagrams


06T83110 (SPDT) 06T83210 (SPDT)

06T83221 (SPDT) 06T83220/322 (DPDT)

06T85110 / 06T85111 / 06T8521T / 06T8541T (SPDT) 06T85120 / 06T85121 / 06T8522T / 06T8542T (DPDT)

154
www.fmfelectric.com
T8
Time Relay

Standard: IEC 61812-1


IEC 60947-5-1

Working Wiring Diagrams


06T8531T (SPDT) 06T8532T (DPDT)

06T85520 (DPDT) - Star-delta Time Relay

155
www.fmfelectric.com
M8
Call/Reset Relay

Standard: IEC 61812-1


IEC 60947-5-1

Call/Reset Relay M8 Series

Floor fire safety alarm system: the fire alarm switch on


each floor is the call switch, which can only be turned on
but can’t be turned off. The reset switch is installed in the
control room and supervised by a specially-asigned
person.

There are also small-scale call systems with low cost:


community hospitals, welfare homes, or some
small-scale places that need constant supervision. Each
room or bed is equipped with a call switch for
emergency use. Reset switch is installed in a designated
place under supervision.

Application:
• Fire or emergency alarm systems.

Technical Data 06M8-2010 06M8-2020

Dimensions: in (mm) Wiring Diagrams

156
www.fmfelectric.com
M8
Step/Monostable Relay

Standard: IEC 61812-1


IEC 60947-5-1

Step/ Monostable Relay M8 Series

To control the overturn of working state for the device.

Control input can be continuously applied.

Longer mechanical and electrical life, and much quieter


than electromechanical step relays.

Suitable for installation on 365mm rail (in accordance


with EN60715 standard).

Technical Data 06M8-2110

Dimensions: in (mm) Wiring Diagrams

157
www.fmfelectric.com
M8
Step Relay

Standard: IEC 61812-1


IEC 60947-5-1

Step Relay M8 Series

The self-reseting switch is used to replace traditional


mechanical structure wall switch.

Mains power and lower safety voltage can be used.

It has high safety and long life. It can easily perform


multi-point control and get rid of the embarrassment of
dual switches.

Suitable for installation on 365mm rail (in accordance


with EN60715 standard).

Application:
• Industrial machinery ????
• Manufacturing ????

Technical Data 06M8-2210 06M8-2220

Dimensions: in (mm) Wiring Diagrams

158
www.fmfelectric.com
M8
Step Relay

Standard: IEC 61812-1


IEC 60947-5-1

Step Relay M8 Series

The state of output switch can be combined from many


different ways, similar to universal change-over switch,
combination types can be customized according to
clients requirement.

Suitable for installation on 365mm rail (in accordance


with EN60715 standard).

Application:
• ????

Technical Data 06M8-2221 06M8-2222

Dimensions: in (mm) Wiring Diagrams

159
www.fmfelectric.com
M8
Step Relay

Standard: IEC 61812-1


IEC 60947-5-1

Step Relay M8 Series

The state of output switch can be combined from many


different ways, similar to universal change-over switch,
combination types can be customized according to
clients requirement.

Suitable for installation on 365mm rail (in accordance


with EN60715 standard).

Application:
• ????

Technical Data 06M8-2223

Dimensions: in (mm) Wiring Diagrams

160
www.fmfelectric.com
M8
Step / Monostable & Call / Reset Relay

Standard: IEC 61812-1


IEC 60947-5-1

Working Wiring Diagrams


06M8-2010 (SPDT) 06M8-2020 (DPDT)

06M8-2110 (SPDT) 06M8-2110 (SPDT)

06M8-2210 (SPDT) 06M8-2220 06M8-2221 06M8-2222 06M82223


(DPDT)

161
www.fmfelectric.com
L8
Floatless Level Switch

Standard: IEC 61812-1


IEC 60947-5-1

Floatless Level Relay L8 Series

Floatless level switch is a kind of switch that controls the


height of the liquid level in the container. It uses the
conductivity of the liquid to turn on or off the contact
output when the liquid level reaches a certain height,
and automatically monitor run or stop of the water
pump to achieve the purpose of controlling the amount
of liquid in the container.

Application:
• It is generally used in homes, industries, commercial
places, plubic places and other places where automatic
monitoring of water supply and drainage systems is
required.
It has a small size and complete specification.
It can be widely used in domestic water systems, sewage
treatment systems, and special liquid supply systems.

Technical Data 06L8-6008 06L8-6108

Dimensions: in (mm) Wiring Diagrams

162
www.fmfelectric.com
L8
Step/Monostable Switch

Standard: IEC 61812-1


IEC 60947-5-1

Floatless Level Relay L8 Series

Floatless level switch is a kind of switch that controls the


height of the liquid level in the container. It uses the
conductivity of the liquid to turn on or off the contact
output when the liquid level reaches a certain height,
and automatically monitor run or stop of the water
pump to achieve the purpose of controlling the amount
of liquid in the container.

Application:
• It is generally used in homes, industries, commercial
places, plubic places and other places where automatic
monitoring of water supply and drainage systems is
required.
It has a small size and complete specification.
It can be widely used in domestic water systems, sewage
treatment systems, and special liquid supply systems.

Technical Data 06L8-6012 06L8-6112

Dimensions: in (mm) Wiring Diagrams

163
www.fmfelectric.com
L8
Floatless Level Switch

Standard: IEC 61812-1


IEC 60947-5-1

Floatless Level Switch L8 Series

Floatless level switch is a kind of switch that controls the


height of the liquid level in the container. It uses the
conductivity of the liquid to turn on or off the contact
output when the liquid level reaches a certain height,
and automatically monitor run or stop of the water
pump to achieve the purpose of controlling the amount
of liquid in the container.

Application:
• It is generally used in homes, industries, commercial
places, plubic places and other places where automatic
monitoring of water supply and drainage systems is
required.
It has a small size and complete specification.
It can be widely used in domestic water systems, sewage
treatment systems, and special liquid supply systems.

Technical Data 06L8-6024 06L8-6124

Dimensions: in (mm) Wiring Diagrams

164
www.fmfelectric.com
L8
Floatless Level Switch

Standard: IEC 61812-1


IEC 60947-5-1

Wiring Diagrams
Water Supply

When water level of tank reaches E1,


pump stops working and stops the water
intake.
When water level drops bellow E2, pump
runs automatically and water tank starts
to enter water.
When pump is running, the light is OFF.

Drain Off Water

When water level of tank reaches E1,


pump starts to work and starts to drain.
When water level drops bellow E2,
pump stops working and water tank
stops draining.
When pump is running, the light is ON.

165
www.fmfelectric.com
TM
Timer Relay

TM.181H TM.180A TM.E8 TM.20A

166
www.fmfelectric.com
E05
Modular Socket

Standard: IEC 60884

Modular Socket

E05.20 E05.7 E05.20B E05.35

Technical Data

Application The Modular Sockets can be used together with our modular products for connection of mobile devices, tools
or electric and electronic non-modular equipments directly inside civil and industrialswitchboards.

Model Rated current (A) Standard Width (mm) Connection capacity


E05.20 16A Germany 44.5 •4mm2
E05.07 16A France 44.5 •4mm2
E05.20B 13A UK 44.5 •4mm2
E05.35 15A USA 62 •2.5mm2

Electrical
Features

Overall and Installation Dimension (mm)

62 48
92

E05.20 E05.20B
E05.7 E05.35

167
www.fmfelectric.com
F8
Light Activated Switch

Standard: IEC 61812-1


IEC 60947-5-1

Light Activated Switch F8 Series

Turn on or turn off electrical equipment according to the


change of light intensity.
The action threshold can be set according to the
demand.

When the ambient brightness decreases and drops


below the selected threshold, the control contact is
closed; when the ambient brightness increasesand rises
above the selected threshold, the control contact opens.

Suitable for installation on 365mm rail (in accordance


with EN60715 standard).

Application:
• Lightning or lightning control system.

Technical Data 06F8-3110


2300W Incandescent Lamp 230V
2300W Halogen Lamp 230V
2300VA Fluorescent Tube
8x 40W(4.7µF)
6x 58W(7µF) Parallel Compensated Fluorescent Tube, Max 400W (42µF)
2x 100W(18µF)
12x 7W; 8x 11W; 4x 20W Compact Fluorescent Lamp (CFL), Max 90W
1000 VA Non-corrected Mercury Vapour Lamp
400VA (42µF) Parallel-corrected Mercury Vapour Lamp
1000 VA Non-corrected Sodium Vapour Lamp
400VA (42µF) Parallel-corrected Sodium Vapour Lamp
20W LED Up to 2W
55W LED Between 2W and 8W
Output Characteristics SPDT
Contact Load Output 16A/250VAC
Working Voltage Single Voltage: AC110V, AC220V

Dimensions: in (mm) Wiring Diagrams

L
N

C L N

B1 B2

168
www.fmfelectric.com
FS
Switching Power Supply

Standard: IEC 61812-1


IEC 60947-5-1

Switching Power Supply FS Series

Ultra-thin design: width 18mm (1SU) / 36mm (2SU)


International universal input: 85~264VAC (277VAC available)
No-load loss: <0.3W
Isolation level: II
Pass LPS (Limited Power Supply)
Adjustable DC output voltage
Natural air cooling, working temperature: -30°C ~ +70°C
Suitable for installation on 35/7.5 or 35/15 rail.
Overvoltage level: III
LED indicates power ON.

Application:
• Home control system.
• Building automation
• Industrial control system
• Industrial automation
• Mechanical and electrical equipment

Technical Data FS4-XXXX FS4-XXXX


DC Voltage 5V 12V
Rated Current 2.4A 1.25A
Rated Power 12W 15W
Ripple and Noise (max) 80mVp-p 120mVp-p
Output Voltage Adjustment Range 4.5~5.5V 10.8~13.8V
Voltage Accuracy ±2.0% ±1.0%
Linear Adjustment Rate ±1.0% ±1.0%
Load Adjustment Rate ±1.0% ±1.0%
Start and Rise Time 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Under Full Load)
Hold Time (Typ.) 300ms/230VAC 12ms/115VAC (Under Full Load)
Voltage Range 85-264VAC (277VAC Available) 120-370VAC (390VDC Available)
Frequency Range 47-63Hz
Input Efficiency (Typ.) 80% 85%
Alternating Current 0.5A/115VAV 0.25A/230VAV
Surge Current Cold start 25A/115VAC 45A/230VAC
110-145% of rated output power
When the output voltage is less than 50%, it is in hiccup mode, and it can automatically recover after
Overload the abnormal load condition is removed.
When the output voltage is 50%-100%, it is constant current mode, and it can automatically recover
Protection
after the abnormal load condition is removed.
Over-Voltage 5.75-6.75V 14.2 - 16.2V
Protection mode: Turn off the output, clamp by the Zener diode
Dimensions: in (mm) Wiring Diagrams

169
www.fmfelectric.com
FS
Switching Power Supply

Standard: IEC 61812-1


IEC 60947-5-1

Switching Power Supply FS Series

Ultra-thin design: width 18mm (1SU) / 36mm (2SU)


International universal input: 85~264VAC (277VAC available)
No-load loss: <0.3W
Isolation level: II
Pass LPS (Limited Power Supply)
Adjustable DC output voltage
Natural air cooling, working temperature: -30°C ~ +70°C
Suitable for installation on 35/7.5 or 35/15 rail.
Overvoltage level: III
LED indicates power ON.

Application:
• Home control system.
• Building automation
• Industrial control system
• Industrial automation
• Mechanical and electrical equipment

Technical Data FS4-4111815 FS4-4111824


DC Voltage 15V 24V
Rated Current 1A 0.63A
Rated Power 15W 15.2W
Ripple and Noise (max) 120mVp-p 150mVp-p
Output Voltage Adjustment Range 13.5~18V 21.6~29V
Voltage Accuracy ±1.0% ±1.0%
Linear Adjustment Rate ±1.0% ±1.0%
Load Adjustment Rate ±1.0% ±1.0%
Start and Rise Time 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Under Full Load)
Hold Time (Typ.) 300ms/230VAC 12ms/115VAC (Under Full Load)
Voltage Range 85-264VAC (277VAC Available) 120-370VAC (390VDC Available)
Frequency Range 47-63Hz
Input Efficiency (Typ.) 85.5% 86%
Alternating Current 0.5A/115VAV 0.25/230VAV
Surge Current Cold start 25A/115VAC 45A/230VAC
110-145% of rated output power
When the output voltage is less than 50%, it is in hiccup mode, and it can automatically recover after
Overload the abnormal load condition is removed.
When the output voltage is 50%-100%, it is constant current mode, and it can automatically recover
Protection
after the abnormal load condition is removed.
Over-Voltage 18.8 - 22.5V 30 - 36V
Protection mode: Turn off the output, clamp by the Zener diode
Dimensions: in (mm) Wiring Diagrams

170
www.fmfelectric.com
FS
Switching Power Supply

Standard: IEC 61812-1


IEC 60947-5-1

Switching Power Supply FS Series

Ultra-thin design: width 18mm (1SU) / 36mm (2SU)


International universal input: 85~264VAC (277VAC available)
No-load loss: <0.3W
Isolation level: II
Pass LPS (Limited Power Supply)
Adjustable DC output voltage
Natural air cooling, working temperature: -30°C ~ +70°C
Suitable for installation on 35/7.5 or 35/15 rail.
Overvoltage level: III
LED indicates power ON.

Application:
• Home control system.
• Building automation
• Industrial control system
• Industrial automation
• Mechanical and electrical equipment

Technical Data FS4-4111815


DC Voltage 48V
Rated Current 0.32A
Rated Power 15.4W
Ripple and Noise (max) 240mVp-p
Output Voltage Adjustment Range 43.2~55.2V
Voltage Accuracy ±1.0%
Linear Adjustment Rate ±1.0%
Load Adjustment Rate ±1.0%
Start and Rise Time 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Under Full Load)
Hold Time (Typ.) 300ms/230VAC 12ms/115VAC (Under Full Load)
Voltage Range 85-264VAC (277VAC Available) 120-370VAC (390VDC Available)
Frequency Range 47-63Hz
Input Efficiency (Typ.) 87%
Alternating Current 0.5A/115VAV 0.25A/230VAV
Surge Current Cold start 25A/115VAC 45A/230VAC
110-145% of rated output power
When the output voltage is less than 50%, it is in hiccup mode, and it can automatically recover after
Overload the abnormal load condition is removed.
When the output voltage is 50%-100%, it is constant current mode, and it can automatically recover
Protection
after the abnormal load condition is removed.
Over-Voltage 56.5 - 64.8V
Protection mode: Turn off the output, clamp by the Zener diode
Dimensions: in (mm) Wiring Diagram

171
www.fmfelectric.com
FS
Switching Power Supply

Standard: IEC 61812-1


IEC 60947-5-1

Switching Power Supply FS Series

Ultra-thin design: width 18mm (1SU) / 36mm (2SU)


International universal input: 85~264VAC (277VAC available)
No-load loss: <0.3W
Isolation level: II
Pass LPS (Limited Power Supply)
Adjustable DC output voltage
Natural air cooling, working temperature: -30°C ~ +70°C
Suitable for installation on 35/7.5 or 35/15 rail.
Overvoltage level: III
LED indicates power ON.

Application:
• Home control system.
• Building automation
• Industrial control system
• Industrial automation
• Mechanical and electrical equipment

Technical Data FS4-4113605 FS4-4113612


DC Voltage 5V 12V
Rated Current 3A 2A
Rated Power 15W 24W
Ripple and Noise (max) 80mVp-p 120mVp-p
Output Voltage Adjustment Range 4.5~5.5V 10.8~13.8V
Voltage Accuracy ±2.0% ±1.0%
Linear Adjustment Rate ±1.0% ±1.0%
Load Adjustment Rate ±1.0% ±1.0%
Start and Rise Time 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Under Full Load)
Hold Time (Typ.) 300ms/230VAC 12ms/115VAC (Under Full Load)
Voltage Range 85-264VAC (277VAC Available) 120-370VAC (390VDC Available)
Frequency Range 47-63Hz
Input Efficiency (Typ.) 82% 88%
Alternating Current 0.5A/115VAV 0.25A/230VAV
Surge Current Cold start 25A/115VAC 45A/230VAC
110-145% of rated output power
When the output voltage is less than 50%, it is in hiccup mode, and it can automatically recover after
Overload the abnormal load condition is removed.
When the output voltage is 50%-100%, it is constant current mode, and it can automatically recover
Protection
after the abnormal load condition is removed.
Over-Voltage 5.75 - 7.5V 15 - 18V
Protection mode: Turn off the output, clamp by the Zener diode
Dimensions: in (mm) Wiring Diagram

172
www.fmfelectric.com
FS
Switching Power Supply

Standard: IEC 61812-1


IEC 60947-5-1

Switching Power Supply FS Series

Ultra-thin design: width 18mm (1SU) / 36mm (2SU)


International universal input: 85~264VAC (277VAC available)
No-load loss: <0.3W
Isolation level: II
Pass LPS (Limited Power Supply)
Adjustable DC output voltage
Natural air cooling, working temperature: -30°C ~ +70°C
Suitable for installation on 35/7.5 or 35/15 rail.
Overvoltage level: III
LED indicates power ON.

Application:
• Home control system.
• Building automation
• Industrial control system
• Industrial automation
• Mechanical and electrical equipment

Technical Data FS4-4113615 FS4-4113624


DC Voltage 15V 24V
Rated Current 2A 1.5A
Rated Power 30W 36W
Ripple and Noise (max) 120mVp-p 150mVp-p
Output Voltage Adjustment Range 13.5~18V 21.6~29V
Voltage Accuracy ±1.0% ±1.0%
Linear Adjustment Rate ±1.0% ±1.0%
Load Adjustment Rate ±1.0% ±1.0%
Start and Rise Time 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Under Full Load)
Hold Time (Typ.) 300ms/230VAC 12ms/115VAC (Under Full Load)
Voltage Range 85-264VAC (277VAC Available) 120-370VAC (390VDC Available)
Frequency Range 47-63Hz
Input Efficiency (Typ.) 89% 89%
Alternating Current 0.5A/115VAV 0.25A/230VAV
Surge Current Cold start 25A/115VAC 45A/230VAC
110-145% of rated output power
When the output voltage is less than 50%, it is in hiccup mode, and it can automatically recover after
Overload the abnormal load condition is removed.
When the output voltage is 50%-100%, it is constant current mode, and it can automatically recover
Protection
after the abnormal load condition is removed.
Over-Voltage 18.8 - 22.5V 30 - 36V
Protection mode: Turn off the output, clamp by the Zener diode
Dimensions: in (mm) Wiring Diagram

173
www.fmfelectric.com
FS
Switching Power Supply

Standard: IEC 61812-1


IEC 60947-5-1

Switching Power Supply FS Series

Ultra-thin design: width 18mm (1SU) / 36mm (2SU)


International universal input: 85~264VAC (277VAC available)
No-load loss: <0.3W
Isolation level: II
Pass LPS (Limited Power Supply)
Adjustable DC output voltage
Natural air cooling, working temperature: -30°C ~ +70°C
Suitable for installation on 35/7.5 or 35/15 rail.
Overvoltage level: III
LED indicates power ON.

Application:
• Home control system.
• Building automation
• Industrial control system
• Industrial automation
• Mechanical and electrical equipment

Technical Data FS4-4113648


DC Voltage 48V
Rated Current 0.75A
Rated Power 36W
Ripple and Noise (max) 240mVp-p
Output Voltage Adjustment Range 43.2~55.2V
Voltage Accuracy ±1.0%
Linear Adjustment Rate ±1.0%
Load Adjustment Rate ±1.0%
Start and Rise Time 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Under Full Load)
Hold Time (Typ.) 300ms/230VAC 12ms/115VAC (Under Full Load)
Voltage Range 85-264VAC (277VAC Available) 120-370VAC (390VDC Available)
Frequency Range 47-63Hz
Input Efficiency (Typ.) 90%
Alternating Current 0.5A/115VAV 0.25A/230VAV
Surge Current Cold start 25A/115VAC 45A/230VAC
110-145% of rated output power
When the output voltage is less than 50%, it is in hiccup mode, and it can automatically recover after
Overload the abnormal load condition is removed.
When the output voltage is 50%-100%, it is constant current mode, and it can automatically recover
Protection
after the abnormal load condition is removed.
Over-Voltage 56.5 - 64.8V
Protection mode: Turn off the output, clamp by the Zener diode
Dimensions: in (mm) Wiring Diagram

174
www.fmfelectric.com
Residential Safety

Residential Safety Sub-Index


S19 - Safety devices.............................................................................. 176

S1901 - Smoke Sensorad .................................................................................... 176


S1902 - Emergency Led Signaling ................................................................... 176
S1903 - Emergency Ligt ...................................................................................... 177
S19
Safety devices

S19.01 Smoke Sensor


Electrical Characteristics
Battery: 9V
Battery Duration: 10 years
Type of Smoke Detector: Photoelectric
Sensitivity: 1.51%
Temperature: 4-38°C
Humidity: 0-85%
Alarm: Incorpored
Sound Pressure Level: 85db from 3mts
Verification button: yes
Operating LED: yes
Sound indicator of battery status: yes

S19.02 Led Signaling


Electrical Characteristics
Mode Of Operation: Maintained
Supply Voltage: 220-240V 50-60Hz
Power Consumption: 2.5W
Output Voltage: 3.6V
Output Power: 0.3W
Lumen Output: 8.3Lm MAX
Battery: 3.6V500mAH Ni-Cad Battery
Max Change Current (mA): 106mA
Max Discharge Current (mA): 142mA
Charging Time: 20H
Discharging Time: 6H
Lamp: 5pcs power LED
IP Rating: IP20
Models:

Overall and mounting dimensions (mm)

176
www.fmfelectric.com
S19
Safety devices

S19.03 Emergency Light - 2 Spots


Electrical Characteristics
Mode Of Operation: Automatic / Manual
Supply Voltage: 120-277VAC 50-60Hz
Power Consumption: 2W
Battery: 3.6V 1000mAh Ni-Cad Battery

Charging Time: 24Hs


Discharging Time: 3Hs
LED Lamps: 24 Ultra bright LED 2835SMT

S19.03 Emergency Light - 2 Spots


Electrical Characteristics
Mode Of Operation: Automatic / Manual
Supply Voltage: 100-240VAC 50-60Hz
Power Consumption: 6.6W
Battery: 6V 4000mAh Lead-acid Battery

Charging Time: 24Hs


Discharging Time: 3Hs
LED Lamps: 24 Ultra bright LED 2835SMT

S19.03 Emergency Light - LED Bar


Electrical Characteristics
Mode Of Operation: Automatic / Manual
Supply Voltage: 120-277VAC 50-60Hz
Power Consumption: 1.5 - 3.5W
Battery: 4V 2500mAh Lead-acid Battery

Charging Time: 24Hs


Discharging Time: 8Hs economic mode / 1.5Hs full mode
LED Lamps: 30, 60 or 90 LEDs

177
www.fmfelectric.com
Notes

178
www.fmfelectric.com
Notes

179
www.fmfelectric.com
PROTECTION,
SECURITY AND
SECTIONING FOR
ALL YOUR
CIRCUITS

+54 9 11 2407 7976


info@fmfelectric.com
www.fmfelectric.com