You are on page 1of 4

Mobile Equipment SEVERITY

Oil Analysis Report Kwazulu-Natal


4 The Terrace NORMAL
Westway Office Park
Westville, 3629
Tel: 031 700 5460 critical
Fax: 031 700 5471
Latest Sample: Z529702 Severity: NORMAL urgent

Severity
Gauteng
Mr. Nick Miji P O Box 284 border
Sakania Isando
Democratic Republic of Congo 1600 normal
Tel: 011 392 6322
Fax: 011 392 6340 1 2 3 4 5 Key

Sample Number: B118287


Vehicle : ADT0156 Company : ERG - Pit

ple
Serial No : V320074 Code : 4EMPZM
Alt Id : AD0156

te s t S am Job No :
Eq Make/Model : VOLVO A60H

The La Location: EMS_PIT


Component : DROP BOX
Cmp Make/Model: VOLVO A60H Not Oil : ORYX GEARAX LS 80W90
Queries : Please Contact The Diagnostic Department

Diagnosis Current Sample


5.) s/n:B118287 on 02/12/2021 SMR:9054HRS
Wear rates are normal and the sample provided appears free from
unacceptable contamination or degradation. Debris analysis normal.

Diagnoses Previous History Feedback

1.) s/n:B122375 on 28/08/2021 SMR:7729HRS SMR:HRS


Registration/serial number does not match the fleet/plant number according Was not at frontier at this time of sampling .
to our computer records. Please confirm the registration/serial number and
the matching fleet/plant number. Wear rates are normal. Debris analysis
revealed evidence of coarse dirt ingress, check for point of entry. Coarse
dirt contamination makes the oil unfit for further use. Change the oil. Please
return feedback. REPEAT PROBLEM coarse-dirtx3 .

2.) s/n:B122726 on 13/09/2021 SMR:8016HRS


Wear rates are normal and the sample provided appears free from
unacceptable contamination or degradation. A microscopic particle
examination of particles filtered from the oil revealed no abnormal
contamination.

3.) s/n:B122810 on 22/09/2021 SMR:8746HRS 31/10/2021 SMR:8535HRS


Registration/serial number does not match the fleet/plant number according Mathurin_chongo@rulvis_com: done on the 30th oct 2021we
to our computer records. Please confirm the registration/serial number and have checked the correct oil level and abnormal noise but
the matching fleet/plant number. Wear rates have increased. A microscopic found any abnormality.Done by: reagan .
particle examination of particles filtered from the oil revealed no abnormal
contamination. Check correct oil level is being maintained. Check for
abnormal noise. Please return feedback.

4.) s/n:B155280 on 30/10/2021 SMR:8535HRS 15/11/2021 SMR:8754HRS


Registration/serial number does not match the fleet/plant number according Meidianto_med@gmail_com:done drain oil and check drain
to our computer records. Please confirm the registration/serial number and plug (no found particle)change oil (75w80)performed by:
the matching fleet/plant number. Debris analysis revealed a light hubert volvo crewdate: 12.11.2021 .
concentration of small wear particles and evidence of coarse dirt ingress.
Check correct oil level is being maintained. Check for abnormal noise. The
oil was not fit for further use due to contamination. Oil already changed do
not drain again. Please return feedback.

WearCheck Is An ISO 9001 & ISO 14001 Registered Company P.T.O.


*NORMAL* Vehicle:ADT0156 Serial No:V320074 Alt Id:AD0156 - DROP BOX

Sample Date Date Date Oil Oil In Filter Oil Oil Brand
Number Sampled Received Reported Consumption SMR UNITS Service Changed Drained And Grade RRI
1 B122375 28/08/2021 31/08/2021 01/09/2021 - 7729 HRS 649 No No VOLVO GO102 500
2 B122726 13/09/2021 17/09/2021 20/09/2021 - 8016 HRS 936 No Yes VOLVO 75W80 500
3 B122810 22/09/2021 24/09/2021 27/09/2021 - 8746 HRS 638 No Yes VOLVO 75W80 500
4 B155280 30/10/2021 01/11/2021 02/11/2021 - 8535 HRS 519 No Yes VOLVO 75W80 500
5 B118287 02/12/2021 07/12/2021 08/12/2021 - 9054 HRS 519 No Yes VOLVO 75W80 500

Wear Metals Particle Quantifier Index

PQ Index
173
173
Aluminium
Chromium

PQ Index
Titanium
Sample

Copper
Nickel

Silver
Lead
Iron

Tin

1 26 0 0 5 2 0 0 0 0 5
2 40 0 0 8 3 0 0 6 0 5
3 97 0 0 3 5 0 0 0 0 5
4 33 0 0 5 2 0 0 0 0 173
5 14 0 0 2 1 0 0 0 0 8
5 5 5 8
0
1 2 3 4 5
A full spectrometric analysis is carried out on all samples but only relevant results are reported in parts/million

Contaminants Silicon

Silicon
9
Manganese

9.00
Water(%)
Sodium
Sample
Silicon

5
1 5 3 0 ND
2 9 2 0 ND
3 7 0 1 ND
4 2 2 0 ND 2
5 1 1 0 ND 1

0.00
1 2 3 4 5
A full spectrometric analysis is carried out on all samples but only relevant results are reported in parts/million

Additives & Lubricant Condition Viscosity

Viscosity in cSt@40 ºC
Phosphorous

51.7
Molybdenum

52 49.6 49.8 50.4


Viscosity in

49.3
Magnesium

Potassium

cSt@40 ºC
Calcium
Sample

Boron
Zinc

1 1 15 0 15 2359 178 0 49.6


2 0 14 0 20 2492 158 0 49.3
3 7 42 1 48 2526 157 0 51.7
4 1 8 0 6 2279 167 0 49.8
5 0 7 0 7 2215 167 0 50.4
0
1 2 3 4 5
A full spectrometric analysis is carried out on all samples but only relevant results are reported in parts/million

Graphical Representation Of Key Data Cumulative Particle Count / ml


Oil In Service Iron
936 97
936 97
Cleanliness
100 micron
14 micron
20 micron
25 micron
50 micron
75 micron
4 micron

6 micron
Sample

649 638
PVI

519 519

40
1 101914 22784 22 3 1 0 0 0 24/22/12 13.12
33 2 88722 22593 30 11 4 1 0 0 24/22/12 12.46
26 3 82173 26110 28 3 0 0 0 0 24/22/12 12.95
14 4 105503 31203 307 99 48 20 3 1 24/22/15 21.16
5 43676 3981 95 61 41 22 7 2 23/19/14 10.59
0 0
1 2 3 4 5 1 2 3 4 5

Copyright Wearcheck - Issued subject to standard conditions (available on request).


Mobile Equipment SEVERITY
Oil Analysis Report Kwazulu-Natal
4 The Terrace NORMAL
Westway Office Park
Westville, 3629
Tel: 031 700 5460 critical
Fax: 031 700 5471
Latest Sample: Z529702 Severity: NORMAL urgent

Severity
Gauteng
Mr. Nick Miji P O Box 284 border
Sakania Isando
Democratic Republic of Congo 1600 normal
Tel: 011 392 6322
Fax: 011 392 6340 1 2 3 4 5 Key

Sample Number: Z505814


Vehicle : ADT0156 Company : ERG - Pit

ple
Serial No : V320074 Code : 4EMPZM
Alt Id : AD0156

te s t S am Job No :
Eq Make/Model : VOLVO A60H

The La Location: EMS_PIT


Component : DROP BOX
Cmp Make/Model: VOLVO A60H Not Oil : ORYX GEARAX LS 80W90
Queries : Please Contact The Diagnostic Department

Diagnosis Current Sample


5.) s/n:Z505814 on 17/03/2022 SMR:9896HRS
The period oil has been in use is unknown. Wear rates are normal and the
sample provided appears free from unacceptable contamination or
degradation. Debris analysis normal.
<Feedback on SMR:HRS>
Machine took over from rulco on 16 march 2022 .

Diagnoses Previous History Feedback

1.) s/n:B122726 on 13/09/2021 SMR:8016HRS


Wear rates are normal and the sample provided appears free from
unacceptable contamination or degradation. A microscopic particle
examination of particles filtered from the oil revealed no abnormal
contamination.

2.) s/n:B122810 on 22/09/2021 SMR:8746HRS 31/10/2021 SMR:8535HRS


Registration/serial number does not match the fleet/plant number according Mathurin_chongo@rulvis_com: done on the 30th oct 2021we
to our computer records. Please confirm the registration/serial number and have checked the correct oil level and abnormal noise but
the matching fleet/plant number. Wear rates have increased. A microscopic found any abnormality.Done by: reagan .
particle examination of particles filtered from the oil revealed no abnormal
contamination. Check correct oil level is being maintained. Check for
abnormal noise. Please return feedback.

3.) s/n:B155280 on 30/10/2021 SMR:8535HRS 15/11/2021 SMR:8754HRS


Registration/serial number does not match the fleet/plant number according Meidianto_med@gmail_com:done drain oil and check drain
to our computer records. Please confirm the registration/serial number and plug (no found particle)change oil (75w80)performed by:
the matching fleet/plant number. Debris analysis revealed a light hubert volvo crewdate: 12.11.2021 .
concentration of small wear particles and evidence of coarse dirt ingress.
Check correct oil level is being maintained. Check for abnormal noise. The
oil was not fit for further use due to contamination. Oil already changed do
not drain again. Please return feedback.

4.) s/n:B118287 on 02/12/2021 SMR:9054HRS


Wear rates are normal and the sample provided appears free from
unacceptable contamination or degradation. Debris analysis normal.

WearCheck Is An ISO 9001 & ISO 14001 Registered Company P.T.O.


*NORMAL* Vehicle:ADT0156 Serial No:V320074 Alt Id:AD0156 - DROP BOX

Sample Date Date Date Oil Oil In Filter Oil Oil Brand
Number Sampled Received Reported Consumption SMR UNITS Service Changed Drained And Grade RRI
1 B122726 13/09/2021 17/09/2021 20/09/2021 - 8016 HRS 936 No Yes VOLVO 75W80 500
2 B122810 22/09/2021 24/09/2021 27/09/2021 - 8746 HRS 638 No Yes VOLVO 75W80 500
3 B155280 30/10/2021 01/11/2021 02/11/2021 - 8535 HRS 519 No Yes VOLVO 75W80 500
4 B118287 02/12/2021 07/12/2021 08/12/2021 - 9054 HRS 519 No Yes VOLVO 75W80 500
5 Z505814 17/03/2022 24/03/2022 26/03/2022 9896 HRS 0 No No GEARAX LS 80W90

Wear Metals Particle Quantifier Index

PQ Index
173
173
Aluminium
Chromium

PQ Index
Titanium
Sample

Copper
Nickel

Silver
Lead
Iron

Tin

1 40 0 0 8 3 0 0 6 0 5
2 97 0 0 3 5 0 0 0 0 5
3 33 0 0 5 2 0 0 0 0 173
4 14 0 0 2 1 0 0 0 0 8
5 7 0 0 2 0 0 0 0 0 5
5 5 8 5
0
1 2 3 4 5
A full spectrometric analysis is carried out on all samples but only relevant results are reported in parts/million

Contaminants Silicon

Silicon
9
Manganese

9.00
Water(%)
Sodium
Sample
Silicon

1 9 2 0 ND
2 7 0 1 ND
3 2 2 0 ND 3
4 1 1 0 ND 2
5 3 0 0 ND 1

0.00
1 2 3 4 5
A full spectrometric analysis is carried out on all samples but only relevant results are reported in parts/million

Additives & Lubricant Condition Viscosity

Viscosity in cSt@40 ºC
Phosphorous

55
Molybdenum

55
Viscosity in
Magnesium

51.7
Potassium

50.4
cSt@40 ºC

49.3 49.8
Calcium
Sample

Boron
Zinc

1 0 14 0 20 2492 158 0 49.3


2 7 42 1 48 2526 157 0 51.7
3 1 8 0 6 2279 167 0 49.8
4 0 7 0 7 2215 167 0 50.4
5 69 135 8 167 2152 157 0 55.0
0
1 2 3 4 5
A full spectrometric analysis is carried out on all samples but only relevant results are reported in parts/million

Graphical Representation Of Key Data Cumulative Particle Count / ml


Oil In Service Iron
936 97
936 97
Cleanliness
100 micron
14 micron
20 micron
25 micron
50 micron
75 micron
4 micron

6 micron
Sample

638
PVI

519 519

40
1 88722 22593 30 11 4 1 0 0 24/22/12 12.46
33 2 82173 26110 28 3 0 0 0 0 24/22/12 12.95
3 105503 31203 307 99 48 20 3 1 24/22/15 21.16
14 4 43676 3981 95 61 41 22 7 2 23/19/14 10.59
7 5 23348 2695 38 8 4 1 0 0 22/19/12 2.49
0
0 0
1 2 3 4 5 1 2 3 4 5

Copyright Wearcheck - Issued subject to standard conditions (available on request).