NOTES:
1. THE TOPOGRAPHIC INFORMATION WAS
DELIVERED BY ALEXANDER RESTREPO A 1 001 01 102
MOVIL: 3016357798 TOPOGRAPHER. ALL
MEASUREMENT AND LEVELS MUST BE PLANO No
VERIFIED ON SITE .
2. THE COLUMNS AXES LAYING OUT MIGHT BE SUPPLY AND INSTALLATION OF A 25 MM THICK
TECH MET ROOF, WITH POLYURETHANE
DONE STARTING FROM THE DELTA OR
VERTEX THAT APPEAR ON THE SITE. GPS-1 1 2 3 4 5 6 7 INSULATION, 28/28 GAUGE SHEET , GREEN
OLIVE COLOR, USEFUL WIDTH 1000 MM
AND GPS-2 (INCLUDES SCREWS) METECNO.
3. THE CONTRACTOR MUST VERIFY THE EXACT SUMINISTRO E INSTALACION DE CUBIERTA TIPO TECH
LOCATION OF UTILITIES BEFORE STARTING E C2
MET DE 25 MM DE ESPESOR, CON AISLAMIENTO EN
POLIURETANO, CALIBRE 28/28 LAMINA/LAMINA, COLOR
THE WORKS ON THE CONSTRUCTION SITE, D1 A 1 001 01 201
A1 A4 VERDE OLIVA, ANCHO ÚTIL 1000 MM MARCA METECNO
ANY CONFLICT FOUND WITH EXISTING D4 A 1 001 01 301
A 1 001 01 301 A 1 001 01 301
UTILITIES MUST BE REPORTED IMMEDIATELY A 1 001 01 301 EMBASSY OF THE UNITED STATES
D-1 CF-06 RAINWATER CHANNEL, IN 20 GAUGE GALVANIZED NARCOTICS AND LAW ENFORCEMENT
TO THE REPRESENTATIVE OF THE A 1 001 01 505 A 1 001 01 504 SHEET, 129 CM WITH WASH PRIMER SOLVENT AFFAIRS SECTION - I.N.L BOGOTA -
CONTRACT OFFICER. BASE REF:509A AND ANTICORROSIVE PAINTING
COLOMBIA
4. SIDEWALK (FLUTED CONCRETE SLAB WITH PINTULUX PREMIUM
TEXTURING CANAL DE AGUAS LLUVIAS, EN LAMINA GALVANIZADA
CALIBRE 20 , DESARROLLO 129 CM, CON WASH
BRUSH 1.50 PRIMER BASE SOLVENTE REF:509A Y PINTURA NOTICE:
DIMENSION (HANDLES) 2 UND 1.84 ANTICORROSIVA PINTULUX PREMIUM. THIS DOCUMENT IS PROPERTY OF THE U.S.
GOVERMENT. FURTHER REPRODUCTION AND/OR
BRISTLES THICKNESS 1mm x 3mm DISTRIBUTION IS PROHIBITED WITHOUT THE
BRISTLES GAP 16mm WRITTEN PERMISSION OF THE INTERNATIONAL
NARCOTICS AND LAW ENFORCEMENT SECTION
BRISTLE LENGTH 14 cm (INL), BOGOTA COLOMBIA. INFORMATION ON THIS
DOCUMENT IS NOT BE ALTERED EXCEPT WITH
NUMBER OF BRISTLES 79 THE WRITTEN APPROVAL OF THE OFFICE.
ADAPTER 1 UND CF-03
ALUMINUM STRUCTURE A 1 001 01 502 MANAGED BY:
STEEL STRIP BRISTLE
WEIGHT 5.2 Kg.) D I.N.L
5. ALL DETAILS OF THE SUPPLIES AT THE D INTERNATIONAL NARCOTICS AND LAW
TIME OF INSTALLATION MUST BE ENFORCEMENT SECTION (INL).
EMBASSY OF THE UNITED STATES
CONSULTED WITH THE SUPPLIER. BOGOTA, COLOMBIA
6. FLOORS FINISHES IN WET AREAS MUST
HAVE A SLOPE TOWARD THE SIPHON COR:
E:1177375
AN AD (
O
R
ING
EL 1% Y EL 2%. VER SIFONES EN PLANOS EX
IST
HIDRÁULICOS.
7. TODOS LOS ELEMENTOS UBICADOS POR ENCIMA B
DEL NIVEL CIELORASO, INCLUIDA LA CARA LEGEND:
INFERIOR DE LA CUBIERTA,DEBEN IR PINTADOS
DE GRIS GRAFITO. B METALLIC FLANGE GAUGE
20, WITH WASH PRIMER
SOLVENT BASE REF:509A
AND ANTICORROSIVE
PAINTING PINTULUX
SLOPE 20% PREMIUM
(PENDIENTE 20%) FLANCHE METALICO CALIBRE
OBSERVATIONS
OBSERVACIONES
D2 D2
A 1 001 01 302 A 1 001 01 302
B
OBSERVATIONS:
• ALL LEVELS AND DIMENSIONS MUST BE VERIFIED
ON SITE BY THE BUILDING CONTRACTOR
ESPECIFICACIONES
A A 1
2
10 % SUBMITTAL
35 % SUBMITTAL
06-08-2021
06-08-2021
INJECTED POLYURETHANE 1" METECNO SHEET
DESIGNED BY:
SIMULACIÓN VIRTUAL
CUARTO ELECTRICO
ZONA DE LAVADO
ROOF PLAN
ESPACIO
SIGNATURE:
A 1 001 01 201
SCALE 1:75 (ESCALA GRAFICA 1:75)
B2 PROFESSIONAL CARD: 25700 31084 CND
VIRTUAL SIMULATION
PLANTA CUBIERTA
ELECTRICAL ROOM
STORAGE AREA
TRAINING AREA
26-05-2022
No. NAME
BATHROOMS
SPACE/
WASH ZONE
FILE: SCALE:
101. A 1 001 01 1:75
PLAN No:
A 1 001 01 102
01
02
03
04
05
06