Professional Documents
Culture Documents
7.
6.
5.
8.
4.
L= 51 m; ∆V= 5,78 V; ∆V%=0,87 %
NOTAS:
SIN ESCALA
1
JA SOLAR JAM72S30 535/MR L= 34 m; ∆V= 3,85 V; ∆V%=0,58 %
INVERSOR 3 - MPPT 1 - ENTRADA 2 2x1C# 4 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
STRING 23 - 16 MODULOS FV 535 Wp EMT50 mm MPPT 1
JA SOLAR JAM72S30 535/MR L= 52 m; ∆V= 5,89 V; ∆V%=0,89 % 2
INVERSOR 3 - MPPT 2 - ENTRADA 1 2x1C# 4 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
EMT50 mm
INVERSOR 3 (MAESTRO)
D
D
2x1C# 10 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K JA SOLAR JAM72S30 535/MR L= 24 m; ∆V= 2,72 V; ∆V%=0,41 %
EMT50 mm 2x1C# 4 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
DIAGRAMA UNILINEAL DE CORRIENTE CONTINUA
1
5
2
2x1C# 10 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K JA SOLAR JAM72S30 535/MR L= 49 m; ∆V= 5,5 V; ∆V%=0,83 %
MPPT 1
INVERSOR 1 (ESCLAVO)
STRING 2 - 14 MODULOS FV 535 Wp L= 132 m; ∆V= 6,69 V; ∆V%=1,15 % STRING 28 - 16 MODULOS FV 535 Wp EMT50 mm
7
3
JA SOLAR JAM72S30 535/MR 2x1C# 10 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K JA SOLAR JAM72S30 535/MR
INVERSOR 1 - MPPT 2 - ENTRADA 1 EMT50 mm
MPPT 4
4
JA SOLAR JAM72S30 535/MR L= 37 m; ∆V= 4,14 V; ∆V%=0,62 %
INVERSOR 3 - MPPT 5 - ENTRADA 1 2x1C# 4 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
STRING 29 - 16 MODULOS FV 535 Wp EMT50 mm
5
9
MPPT 2
INVERSOR 1 - MPPT 2 - ENTRADA 3 EMT50 mm
MPPT 5
6
10
JA SOLAR JAM72S30 535/MR 2x1C# 10 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K L= 61 m; ∆V= 6,86 V; ∆V%=1,03 %
INVERSOR 1 - MPPT 3 - ENTRADA 1 EMT50 mm INVERSOR 3 - MPPT 6 - ENTRADA 1 2x1C# 4 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
STRING 5 - 14 MODULOS FV 535 Wp L= 125 m; ∆V= 6,39 V; ∆V%=1,1 % STRING 30 - 16 MODULOS FV 535 Wp EMT50 mm
7
11
CANADIAN SOLAR CSI-110K-T400
1.- LOS MATERIALES QUE REQUIEREN CERTIFICACIÓN PARA SU USO CUMPLEN CON LO ESTABLECIDO POR LA SEC.
MPPT 6
8
12
3F + 1N + 1T
3F + 1N + 1T
MPPT 3
JA SOLAR JAM72S30 535/MR
INVERSOR 1 - MPPT 3 - ENTRADA 3 EMT50 mm INVERSOR 3 - MPPT 7 - ENTRADA 1 2x1C# 4 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
2.- LOS VALORES DE CAPACIDAD DE CORRIENTE DE CADA CONDUCTOR FUERON EXTRAÍDOS DEL PLIEGO TÉCNICO RIC N°04.
B.P.C. 150x100 mm
L= 126 m; ∆V= 6,44 V; ∆V%=1,11 %
B.P.C. 150x100 mm
9
13
JA SOLAR JAM72S30 535/MR 2x1C# 10 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K JA SOLAR JAM72S30 535/MR
EMT50 mm
EL INVERSOR MAESTRO LLEVARA DISPOSITIVO WIFI LOGGER STICK PARA RESPECTIVO CONTROL Y MONITOREO DE INVERSORES.
INVERSOR 1 - MPPT 4 - ENTRADA 1
INVERSOR UNIDIRECCIONAL CUENTA CON PERFIL DE RED DE CHILE, PUEDE VISUALIZARSE A TRAVÉS DE LA APP "CSI CLOUD PRO".
MPPT 7
10
14
11
15
4C# 120mm2 RZ1-K +1#C 70 mm2 RZ1-K
MPPT 4
INVERSOR 1 - MPPT 4 - ENTRADA 3 EMT50 mm
MPPT 8
12
JA SOLAR JAM72S30 535/MR L= 60 m; ∆V= 6,75 V; ∆V%=1,01 %
INVERSOR 3 - MPPT 9 - ENTRADA 1 2x1C# 4 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
STRING 34 - 18 MODULOS FV 535 Wp EMT50 mm
17
C
C
18
TODOS LOS TABLEROS DE CAPACIDAD IGUAL O SUPERIOR A 100 A, DEBERAN CONTAR CON CELOSÍAS EN DISPOSICIÓN DIAGONAL, INSTALADAS EN SUS CARAS LATERALES.
L= 60 m; ∆V= 6,75 V; ∆V%=0,9 %
INVERSOR 3 - MPPT 10 - ENTRADA 1 2x1C# 10 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
STRING 35 - 14 MODULOS FV 535 Wp EMT50 mm
19
3.- EL CONDUCTOR DE TIERRA, DEBE TENER UNA SECCIÓN COMO NIMIMO IGUAL A LA MITAD DE LA SECCIÓN QUE POSEEN LOS CONDUCTORES DE FASE, ESTO SEGÚN EL PLIEGO TECNICO N°6.
20
L= 3 m
8
7
4
2
9
5
3
EMT. 32 mm
N°
10
13
12
11
CABLE DE COMUNIACIÓN RS485
CÓDIGO
22-06-VCS-DE-LAY-01-2
22-06-VCS-DE-STR-08-2
22-06-VCS-DE-STR-07-2
22-06-VCS-DE-CTR-12-2
22-06-VCS-DE-PAT-11-2
22-06-VCS-DE-SEG-10-2
22-06-VCS-DE-CAN-06-2
22-06-VCS-DE-CAN-05-2
22-06-VCS-DE-DEQ-13-2
22-06-VCS-DE-CDG-04-2
22-06-VCS-DE-DUC-03-2
22-06-VCS-DE-DUA-02-2
22-06-VCS-DE-EDM-09-2
L= 5 m
A WIFI LOGGER STICK
EMT. 32 mm
L= 3 m
LISTADO DE LÁMINAS
SEGURIDAD
PUESTA A TIERRA
LAYOUT GENERAL
CABLE DE COMUNICACIÓN RS485
CONTROL Y MONITOREO
DISPOSICIÓN DE EQUIPOS
DIAGRAMA DE STRINGS -2
DIAGRAMA DE STRINGS -1
ESTRUCTURA DE MONTAJE
CUADROS DE GENERACIÓN
CABLE DE COMUNIACIÓN RS485
CANALIZACIÓN Y CABLEADO - 2
CANALIZACIÓN Y CABLEADO - 1
DESCRIPCIÓN
INVERSOR 2 - MPPT 1 - ENTRADA 1 EMT50 mm
STRING 9 - 15 MODULOS FV 535 Wp L= 138 m; ∆V= 7,03 V; ∆V%=1,13 %
1
N
JA SOLAR JAM72S30 535/MR 2x1C# 10 mm² H1Z2Z2-K + 1C# 4mm² H07Z1-K
INVERSOR 2 - MPPT 2 - ENTRADA 2 EMT50 mm
B
B
MPPT 2
NOMBRE:
MPPT 8
UBICACIÓN:
16
PROYECTO:
FUSIBLE 20 A gPV
10.748.040-4
A
MPPT 9
A
SEXTA REGIÓN
18
REVISÓ:
LÁMINA:
CHILE
INVERSOR SOLAR FRONIUS TAURO ECO 100 - 3 -D
Rising Sun
M. PAREDES
INSTALADOR:
DESCRIPCIÓN:
03 DE 13
VIÑA CASA SILVA
COMERCIAL FOTOVOLTAICO
ABROBÓ:
CÓD. LAM:
L. SANTIAGO
22-06-VCS-DE-DUC-03-0
1
2