You are on page 1of 2

MA309MH4LSA Smart Three Phase Meter with Direct Connection

 Plug and play communication module which supports


PRIME-PLC/G3-PLC/RF-Mesh/LTE/NB-IoT technology
 Compliant with DLMS/COSEM
 Energy efficiency with advanced measurement with TOU
 Disconnect / reconnect
 Remote authenticated firmware upgrade
 Protect from fraud or tampering

 Measurement and power quality


 Import and export active / reactive / apparent energy/demand/power, 4 quadrant reactive
energy/power; Configurable maximum demand integration period (typically 5, 10, 15, 30 or 60
minutes); Instantaneous import voltage and current per phase, import/export power factor, Frequency;
Instantaneous THDs for voltage, current, phase difference (voltage/current) per phase.
 TOU
 2 sets of tariff structure, up to 8 tariffs; 8 season/week/day profiles; 420 special days
 Billing data
 3 monthly billing data, 3 daily billing data
 Load profile for energy and power quality
 At least 10 programmable channels for energy and demand load profile; At least 10 programmable
channels for power quality load profile; Programmable profiles period (typically 1, 5, 10, 15, 30, 60
minutes). At least 90 days capacity for 30 minutes period.
 Real time clock
 Remote and local synchronization available
 Communication interface
 Optical port, baud rate from 300 to 115,200 bps, default 9600bps
 Plug-and-Play module: support PRIME-PLC/G3-PLC/RF-Mesh/LTE/NB-IoT module
 One RS-485 interfaces with two RJ-45 terminals for external communication module and connect to
other RS-485 meters
 One RJ-45 RS-485 interface for IHD
 Display and indicators
 Character type LCD to support text based messages with back light
 Two LEDs indicate active and reactive pulse
 Three colors LED indicates different communication status
 Disconnect/reconnect
 A latching relay, which complies with IEC 62055-31UC3, supports the disconnect/reconnect power
supply.
 Backup power supply
 Replaceable battery with independent seal, support at least 1 year without main power supply
 Anti-tamper features
 Current reversal detection and measurement; CT open and CT bypass; Magnetic field detection and
protection; Face cover and terminal cover open detection (normal and power outage); Phase Sequence
 Terminals
 Three RJ-45 terminals for two RS-485 ports
 250V/1A auxiliary relay (optional)
 Side grooved voltage screw for calibration

 Reference standard
 IEC 62052-11, IEC 62053-21/23, EN 50470-1/3, DIN 43857, IEC 62056-21/46/53/61/62
 Electrical
Accuracy Active Class 1
Reactive Class 2
Voltage Rated voltage 3*230V/400V, 3*133V/230V
Operation voltage range 80% to 120% Un
Current Rated current 10(100)A
Starting current 20mA
Frequency 50/60Hz ± 5% Hz
Pulse constant 1000 imp/kWh(kvarh) (configurable as requirement)
 Reliability
Meter life ≥15 Years Data retention ≥15 Years
 Mechanical
Dimensions (L x W x H) 216.5×170.5×87(mm) Weight (Kg) 1.9
Enclosure material PC+GF Terminals Barrel type
Insulation protection Class II
 Environmental
Limit operating -40℃ to 75℃ Storage temperature -40℃ to 85℃
temperature
Operating humidity Maximum 95% RH Ingress protection IP54

 Overall dimensions  Wiring diagram