preventive Maintenance Schedule

Solvent Recycler B C D
SR180 - 180V

Optional bag-lifting device

E F I

J H
Optional
vacuum Switch clean solvent hose J G
is inside to dirty solvent inlet

Turn ON.
Oil breather vent
3
K L
Gasket
2
A 1

Daily Maintenance & operation


A Ensure the clean solvent tank is empty. F Review and replace illegible or damaged stickers.
Ensure the bottom of the boiler is clean. G Verify that the air pressure is 90 psi.
B Remove any contaminants from the bottom of boiler. H Verifiy if the vacuum gauge is between (-22) & (-27) inHg.
C Replace the plastic bag.* When the unit is full of used solvent :
Fill up the unit with used solvent to a level of 2” below 1. Make sure the lip of the boiler is clean.
D the retaining ring. 2. Verify the ‘‘gasket’’ is in good shape and clean.
3. Close the lid.
E Keep the surface of the unit clean. 4. Press the < start > button.
5. Verify that the oil breather plug (E/L) is not plugged up.
weekly Maintenance
I Inspect and clean condenser fins if necessary. K Check that the ‘‘gasket’’ is in good shape.

Flush clean solvent through the used solvent pump Check the oil level in the overflow tank is at 1’’
J L (at a minimum) with a dipstick.
(1 or 2 gal). to clean it.
recommended spare parts
# Description Part number # Description sr180/180V Part number
1 Replacement bags (100 bags) 300009 Cover seal (gasket) orange 304020
3
2 Oil 5 gal/20 L (need 3 for oil change) 330068 Cover seal (gasket) black 304025

* Fold the protruding portion of the bag inwards so as not to cover any of the spouts.