MiCOM P130C

Directional Time-Overcurrent and


Frequency Protection Device
P130C/EN IN/B22
(AFSV.10.10480 EN)

Version P130C -302 -401 -602ff

Supporting Documents

This document does not replace the Technical Manual.


Warning
When electrical equipment is in operation dangerous voltage will be present in certain parts of the
equipment. Failure to observe warning notices, incorrect use or improper use may endanger
personnel and equipment and cause personal injury or physical damage.

Before working in the terminal strip area, the device must be isolated. Where stranded conductors
are used, wire end ferrules must be employed.

The signals 'M a i n : B l o c k e d / f a u l t y ' and 'S F M O N : W a r n i n g ( L E D ) ' (permanently assigned


to the LEDs labelled 'OUT OF SERVICE' and 'ALARM') can be assigned to output relays to
indicate the health of the device. Schneider Electric strongly recommends that these output relays
are hardwired into the substation's automation system, for alarm purposes.

Any modifications to this device must be in accordance with the manual. If any other modification
is made without the express permission of Schneider Electric, it will invalidate the warranty, and
may render the product unsafe.

Proper and safe operation of this device depends on appropriate shipping and handling, proper
storage, installation and commissioning, and on careful operation, maintenance and servicing.

For this reason only qualified personnel may work on or operate this device.

For this reason only qualified personnel may work on or operate this device. The user
should be familiar with the warnings in the Safety Guide (SFTY/4LM/G11 or later
version), before working on the equipment.

CE Marking
This product complies with the essential requirements of the following European directives:
Electromagnetic Compatibility Directive (EMC) 2004/108/EC
Low Voltage Directive (LVD) 2006/95/EC

2 MiCOM P130C/EN IN/B22 // AFSV.10.10480 EN /// P130C-302-401-602ff


Protective Conductor Terminal (PCT) / Case Grounding / Protective Earth

The protective conductor must be permanently connected to the PCT (Protective Conductor Terminal) to
maintain the safety features provided by the design. The clamp bracket is marked with a PCT symbol:
The cross-section of the ground conductor must conform to applicable national standards. A minimum
cross-section of 2.5 mm² is required.
All grounding connections must be low-inductance, i.e. they must be kept as short as possible.

MiCOM P130C/EN IN/B22 // AFSV.10.10480 EN /// P130C-302-401-602ff 3


Connection

B
C

X1 Current-measuring PC Interface
inputs
X/Y
1 IA T1 X6
2 2
D1[T]
3 IB T2 3
U16 D2[R]
4
5 IC T3 5
E2[C]
6
7 IN T4 RS 232
8

As per order
X1 Voltage-measuring
inputs Channel 1
9 VAG T5 Optical fiber link
10 VBG T6 X7
11 VCG T7 1
U17 X/Y
12
I> I> I>
X8
1
U18 X/Y
X1 Power supply

13 (+) Vaux or: Wire link


14 (-) X9
X//Y
1
U100
D2[R] 2
3
U19
X1 Binary inputs 4
D1[T] 5
15
VEin
U U1
16 RS 485
Dashed lines: recommended for GFDSS only 17
(GFDSS: Ground Fault Determ. using steady state signals) Vin U2
18 Channel 2
Wire link only
X10
X//Y
X3 Output relays 1
D2[R] 2
35 3
U20
36 K1 4
32 D1[T] 5
33
34 RS 485
29
30 K2 IRIG-B
31 Time synchronization X11
27 1
U21
#
28 K3 #
22
26 K4
25 K5 PCOMM
24 K6 Optical fiber link
23 K7 X31
19 1
U22 X/Y
20 K8
21 X32
1
U23 X/Y

or: Wire link


X33
X//Y
1
D2[R] 2
3
U24
4
D1[T] 5

P130C RS 485

See also section "Protection Conductor Terminal (PCT) / Case Grounding / Protective Earth"

4 MiCOM P130C/EN IN/B22 // AFSV.10.10480 EN /// P130C-302-401-602ff


MiCOM P130C/EN IN/B22 // AFSV.10.10480 EN /// P130C-302-401-602ff 5
Customer Care Centre
http://www.schneider-electric.com/CCC

© 2011 Schneider Electric. All rights reserved.

Schneider Electric
35 rue Joseph Monier
92506 Rueil-Malmaison
FRANCE
Phone: +33 (0) 1 41 29 70 00
Fax: +33 (0) 1 41 29 71 00
www.schneider-electric.com Publishing: Schneider Electric
Publication: MiCOM P130C/EN IN/B22 // AFSV.10.10480 EN /// P130C-302-401-602ff 02/2011

You might also like