Professional Documents
Culture Documents
“MV MAK 1”
ARG DN12582 04
RVC DN12582/5009 A
ELECTRICAL CABLE SCHEDULE MV MAK 1
REVISION HISTORY
UID REV DATE DESCRIPTION PRE CHK APR
REFERENCE
1. DN12582_5001_MSB 440V AC FEEDER PANEL INTEGRATION FOR BWTS
2. DN12582_5002_220V FEEDER PANEL INTEGRATION FOR BWTS
3. DN12582_5003_24V DC DISTRIBUTION BOARD INTEGRATION FOR BWTS
4. DN12582_5004_ BLOCK DIAGRAM FOR BWTS
ELECTRICAL CABLE SCHEDULE MV MAK 1
EC1A-BWTS-01,EC1A-BWTS-02,EC1A-BWTS-03,EC1A-BWTS-04,EC1A-BWTS-05,EC1A-BWTS-06, EC1A-
2 1x95 POWER,ARMOURED 176
BWTS-07, EC1A-BWTS-08
FXA-BWTS-03SMDA_BWTS-01,DIA-BWTS-01, DIA-BWTS-02,DIA-BWTS-03,DIA-BWTS-05,DIA-BWTS-
06,DIA-BWTS-07,DIA-BWTS-08,DIA-BWTS-09,DIA-BWTS-10,DIA-BWTS-11,DIA-BWTS-12,DIA-BWTS-
4 2x2x0.75 SIGNAL,SHIELDED 725 13,DIA-BWTS-14,DIA-BWTS-15,DIA-BWTS-16,DIA-BWTS-17,DIA-BWTS-18,AOA-BWTS-01,AOA-BWTS-
02,AOA-BWTS-03,AIA-BWTS-01,AIA-BWTS-02,AIA-BWTS-03,BP-BWTS-01, BP-BWTS-02,BP-BWTS-
03,BP-BWTS-04, H2A-BWTS-01,DOA-BWTS-09
PA-BWTS-03,PA-BWTS-04,PA-BWTS-05,FXA-BWTS-05,TRO1A-BWTS-02,TRO2A-BWTS-02,MIX-BWTS-
5 3x1.5 POWER,ARMOURED 105
01
PA-BWTS-09, FA-BWTS-04, PA-BWTS-07, PA-BWTS-06, CMA-BWTS-01, SWP-BWTS-02, RPA-BWTS-
6 3x2.5 POWER,ARMOURED 300
03,FXA-BWTS-02
7 3x35 POWER,ARMOURED 30 PA-BWTS-02
NOTE:-CABLE DESIGN LENGTH (APPROX) ESTIMATED WITH THE REFERENCE OF EXISTING GENERAL ARRANGEMENT PLAN & BWTS EQUIPMENT LAYOUT. HOWEVER ACTUAL LENGTH TO BE VERIFIED AND CONFIRMED BY YARD
PRIOR TO THE CABLE CUTTING WITH REFERENCE OF EXISTING CABLE TRAY ROUTE, PENETRATIONS & BWTS EQUIPMENTS LOCATION.
Cable specification
250/400V(90 C)MULTICORE,FLAME RETARDANT MARINE CABLEWITH ANNEALED STRANDED IEC 60228 CLASS 2 COPPER CONDUCTOR.CONDUCTOR PAIRS TO BE COLLECTTIVELY SCREENED WITH BRAIDED COPPER.THE INSULATION
SHOULD BE XLPE AND SHEATHING SHOULD BE FLAME RETARDANT HALOGEN FREE THERMOPLASTIC COMPOUND (SHF1). CABLES SHOULD BE DESIGNED TO MEET IEC60092-350,360,376 CRITERIA AND TESTED AS PER IEC60332-
1AND 3 CATEGORY A/F OR A/F/R.
0.6/1 KV(90 C) MULTICORE,FLAME RETARDANT MARINE CABLE WITH ANNEALED STRANDED IEC 60228 WITH ANNEALED STRANDED IEC 60228 .THE INSULATION SHOULD BE XLPE AND SHEATHING SHOULD BE FLAME RETARDANT
HALOGEN FREE THERMOPLASTIC COMPOUND (SHF1). CABLES SHOULD BE DESIGNED TO MEET IEC60092-353 CRITERIA AND TESTED AS PER IEC60332-1 AND 3 CATEGORY A/F OR A/F/R.
ARIES MARINE
ELECTRICAL CABLE SCHEDULE MV MAK 1
APPROX. CABLE
CABLE SIZE
SI NO CABLE TAG CATEGORY CABLE TYPE EQUIPMENT FROM EQUIPMENT TO DESIGN REMARKS
( mm2 )
LENGTH(METERS)
2 PA-BWTS-02 3x35 POWER ARMOURED NO.2 MSB 440V AC FEEDER PANEL ECR,TWEEN DECK TRANSFORMER RECTIFIER (T/R) E/R,FLOOR 30
3 PA-BWTS-07 3x2.5 POWER ARMOURED NO.1 MSB 440V AC FEEDER PANEL ECR,TWEEN DECK MOTOR STARTER A PLATFORM 30
4 PA-BWTS-09 3x2.5 POWER ARMOURED NO.1 MSB 440V AC FEEDER PANEL ECR,TWEEN DECK FILTER STARTER PANEL E/R,FLOOR 50
10 TR1A-BWTS-01 2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR TRANSFORMER RECTIFIER (T/R) E/R,FLOOR 20
11 FXA-BWTS-01 7x2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR FILTER STARTER PANEL E/R,FLOOR 20
12 FXA-BWTS-02 3x2.5 POWER ARMOURED FILTER STARTER PANEL E/R,FLOOR SP-1-A MOTOR E/R,FLOOR 20
15 FXA-BWTS-05 3x1.5 SIGNAL SHIELDED FILTER STARTER PANEL E/R,FLOOR F-1-A MOTOR E/R,FLOOR 30
16 EC1A-BWTS-01 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
17 EC1A-BWTS-02 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
18 EC1A-BWTS-03 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
19 EC1A-BWTS-04 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
MAXIMUM ALLOWABLE LENGTH 40METERS
FOR EACH INDIVIDUAL CABLES
20 EC1A-BWTS-05 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
21 EC1A-BWTS-06 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
22 EC1A-BWTS-07 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
23 EC1A-BWTS-08 1x95 POWER ARMOURED TRANSFORMER RECTIFIER (T/R) E/R,FLOOR ELECTROLYTIC CELL (C-1-A) E/R,FLOOR 22
24 ECRA-BWTS-01 4x2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR ALARM MONITORING PANEL ECR,TWEEN DECK 55
25 ECRA-BWTS-02 CAT5E SF 4''/FTP SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR ECC ECR,TWEEN DECK 55
APPROXIMATE LOCATION CONSIDRED FOR
26 ECRA-BWTS-03 CAT5E SF 4''/FTP SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR LAN SWITCH BRIDGE DECK 70
LAN SWITCH
27 TRIPA-BWTS-01 2x0.75 SIGNAL SHIELDED TRIP UNIT E/R,FLOOR NO.2 MSB 440V AC FEEDER PANEL ECR,TWEEN DECK 55
28 TRO1A-BWTS-01 2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR CHLORINE SENSORS (TRO1) E/R,FLOOR 20
29 TRO1A-BWTS-02 3x1.5 POWER ARMOURED CHLORINE SENSORS (TRO1) E/R,FLOOR FAN SUPPLY (CHLORINE SENSOR) E/R,FLOOR 5
30 TRO2A-BWTS-01 2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR CHLORINE SENSORS (TRO2) E/R,FLOOR 20
31 TRO2A-BWTS-02 3x1.5 POWER ARMOURED CHLORINE SENSORS (TRO2) E/R,FLOOR FAN SUPPLY (CHLORINE SENSOR) E/R,FLOOR 5
32 FMA-BWTS-01 2x0.75 SIGNAL SHIELDED FLOW METER (FM-1-A) E/R,FLOOR CONTROL PANEL E/R,FLOOR 15
33 SMDA -BWTS-01 2x2x0.75 SIGNAL SHIELDED CONDUCTIVITY SENSOR E/R,FLOOR CONTROL PANEL E/R,FLOOR 30
34 SWP-BWTS-01 4x2x0.75 SIGNAL SHIELDED SEA WATER PUMP STARTER PANEL (SWPSP) E/R,FLOOR CONTROL PANEL E/R,FLOOR 10
35 SWP-BWTS-02 3x2.5 POWER ARMOURED SEA WATER PUMP STARTER PANEL (SWPSP) E/R,FLOOR SEA WATER PUMP (SWP) E/R,FLOOR 30
ARIES MARINE
ELECTRICAL CABLE SCHEDULE MV MAK 1
54 AOA-BWTS-01 2x2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR FLOW CONTROL VALVE, SYSTEM INLET (V1-02) E/R,FLOOR 15
55 AOA-BWTS-02 2x2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR FLOW CONTROL VALVE, SYSTEM INLET (V1-03) E/R,FLOOR 15
57 AIA-BWTS-01 2x2x0.75 SIGNAL SHIELDED FLOW CONTROL VALVE, SYSTEM INLET (V1-02) E/R,FLOOR CONTROL PANEL E/R,FLOOR 20
58 AIA-BWTS-02 2x2x0.75 SIGNAL SHIELDED FLOW CONTROL VALVE, SYSTEM INLET (V1-03) E/R,FLOOR CONTROL PANEL E/R,FLOOR 20
69 DOA-BWTS-10 2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR PUMP CONTROL MODULE (PCM1) E/R,FLOOR 30
70 DOA-BWTS-11 2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR PUMP CONTROL MODULE (PCM2) E/R,FLOOR 25
71 DOA-BWTS-12 2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR PUMP CONTROL MODULE (PCM3) E/R,FLOOR 25
73 DOA-BWTS-14 2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR NAT VALVE A PLATFORM 15
74 BP-BWTS-01 2x2x0.75 SIGNAL SHIELDED BP1 STARTER PANEL ECR,TWEEN DECK CONTROL PANEL E/R,FLOOR 50
75 BP-BWTS-02 2x2x0.75 SIGNAL SHIELDED BP2 STARTER PANEL ECR,TWEEN DECK CONTROL PANEL E/R,FLOOR 50
APPROXIMATE LOCATION CONSIDER FOR
STARTER PANEL
76 BP-BWTS-03 2x2x0.75 SIGNAL SHIELDED B&GS No.1 STARTER PANEL ECR,TWEEN DECK CONTROL PANEL E/R,FLOOR 50
77 BP-BWTS-04 2x2x0.75 SIGNAL SHIELDED B&GS No.2 STARTER PANEL ECR,TWEEN DECK CONTROL PANEL E/R,FLOOR 50
78 PIA-BWTS-01 2x0.75 SIGNAL SHIELDED PRESSURE INDICATOR TRANSMITTER (PIT-1-A) E/R,FLOOR CONTROL PANEL E/R,FLOOR 20
79 PIA-BWTS-02 2x0.75 SIGNAL SHIELDED PRESSURE INDICATOR TRANSMITTER (PIT-2-A) E/R,FLOOR TRIP UNIT E/R,FLOOR 20
80 PIA-BWTS-03 2x0.75 SIGNAL SHIELDED PRESSURE INDICATOR TRANSMITTER (PIT-3-A) E/R,FLOOR CONTROL PANEL E/R,FLOOR 20
81 TA-BWTS-01 2x0.75 SIGNAL SHIELDED TEMPERATURE SENSOR (T-1-A) E/R,FLOOR TRIP UNIT E/R,FLOOR 20
82 DP-BWTS-03 9x2x0.75 SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR MOTOR STARTER E/R,FLOOR 15
83 MIX-BWTS-01 3x1.5 POWER ARMOURED MOTOR STARTER A PLATFORM MIXER MOTOR A PLATFORM 10
84 LS-BWTS-01 2x0.75 SIGNAL SHIELDED LEVEL SWITCH ( LS) E/R,FLOOR CONTROL PANEL E/R,FLOOR 30
85 H2A-BWTS-01 2x2x0.75 SIGNAL SHIELDED HYDROGEN SENSOR (H2-1-A) E/R,FLOOR TRIP UNIT E/R,FLOOR 20
86 CMA-BWTS-02 CAT5E SF 4''/FTP SIGNAL SHIELDED CONTROL PANEL E/R,FLOOR TRIP UNIT E/R,FLOOR 20
87 RPA-BWTS-01 10x1 SIGNAL SHIELDED REPEATER PANEL SHIP OFFICE, POOP DECK CONTROL PANEL E/R,FLOOR 65
APPROXIMATE LOCATION CONSIDRED FOR
88 RPA-BWTS-02 CAT5E SF 4''/FTP SIGNAL SHIELDED REPEATER PANEL SHIP OFFICE, POOP DECK CONTROL PANEL E/R,FLOOR 65
REPEATER PANEL
89 RPA-BWTS-03 3x2.5 POWER ARMOURED REPEATER PANEL SHIP OFFICE, POOP DECK CONTROL PANEL E/R,FLOOR 65
ARIES MARINE
ELECTRICAL CABLE SCHEDULE MV MAK 1
92 DP-BWTS-02 4x0.34 SIGNAL SHIELDED DOSING PUMP (DP) E/R,FLOOR MOTOR STARTER E/R,FLOOR 2 ERMA FIRST SUPPLY( 2 METERS)
93 FSA-BWTS-01 4x0.34 SIGNAL SHIELDED FLOW SWITCH(FS-1-A) E/R,FLOOR CONTROL PANEL E/R,FLOOR 10 ERMA FIRST SUPPLY(10 METERS)
94 PA-BWTS-08 3x1.5 POWER ARMOURED MOTOR STARTER E/R,FLOOR DOSING PUMP (DP) E/R,FLOOR 2 ERMA FIRST SUPPLY
95 FLS-BWTS-01 SILICONE CABLE SIGNAL SHIELDED MOTOR STARTER E/R,FLOOR LEVEL SENSOR (FLS1) E/R,FLOOR 2 ERMA FIRST SUPPLY( 2 METERS)
ARIES MARINE