You are on page 1of 11

G LAS S INDUSTRY

Solution for Vacuum-pressure selection


on counterblow fonction/Plunger cooling

MAC VALVES EUROPE


G LAS S INDUSTRY

Counterblow/Plunger cooling on Emhart machines

Machines: Emhart AIS/NIS

Location on the machine: Under the plateform (blank side)

Application:

- Counterblow ( Blow&Blow and Press&Blow process)


- Plunger cooling (Press&Blow process)

Old solution: Emhart cartridge block piloted by 2* 100s Mac


Valves  130B-611JB + Emhart FPS.

Note: If the customer wants to change the 130B-611JB with


the same valves, please sell the 130B-611JB/T65C.

MAC VALVES EUROPE


G LAS S INDUSTRY

Counterblow/Plunger cooling on Emhart machines

Emhart
base+Mac
pilot valves

MAC VALVES EUROPE


G LAS S INDUSTRY

Counterblow/Plunger cooling on Emhart machines

2* cartridges inside (3/2 NC


and 2/2 NO)
2* 100s pilot

Emhart FPS for


cooling application

MAC VALVES EUROPE


G LAS S INDUSTRY

Principle

V1
V2

MAC VALVES EUROPE


G LAS S INDUSTRY

V1 OFF – V2 OFF
Cyl. Port is exhausted (Pressure regulated by the PQE is 0 bar)

Exhaust PPC

Cylinder port PPC

MAC VALVES EUROPE


G LAS S INDUSTRY

V1 ON – V2 OFF
Cyl. Port is connected to pressure regulated by the PQE for counterblow

Exhaust PPC

Cylinder port PPC

MAC VALVES EUROPE


G LAS S INDUSTRY

V1 ON – V2 ON
Cyl. Port is connected to vacumm for gob loading

Exhaust PPC

Cylinder port PPC

MAC VALVES EUROPE


G LAS S INDUSTRY

V1 OFF – V2 ON
Cyl. Port is connected to vacumm & exhaust

Exhaust PPC

Cylinder port PPC

MAC VALVES EUROPE


G LAS S INDUSTRY

Counterblow/Plunger cooling

New Mac Solution

Replacement of
cartridge block:
MAC SOLUTION:

2valves 54s. + BASE

Base: ME-PQE-08
Valves: 2x 54A-BB-000-DP-DEWJ-1JB/EQ36

MAC VALVES EUROPE


G LAS S INDUSTRY

Counterblow/Plunger cooling

Potential of 5.000 assemblies in Europe!

MAC VALVES EUROPE