You are on page 1of 2

IEC Quick Connect Starter

Enclosed contactor
a starter C g qc

start stop kit qc sspb


overload eecb

transformer qc tx

Features
Non-Reversing, Type 1 Metal Enclosure, Lift-Off Cover
Reset Included (Factory Pre-Set Depth) for E1Plus Overload
Overload Relay Sold Seperately
Contactor Coil (120V AC)
Approximate Dimensions - 11"H x 7.5"W x 5.5"D

Plug
Introducing the new Allen-Bradley Bulletin 109
Quick Connect Starter. This new plug-and-play
starter consists of a pre-wired starter and
operators for trouble-free interconnection and

& Play
interchangeability. The Quick Connect Starter
is available in sizes ranging from 9 to 37A, has
6 different operator options, clearly labelled
ferruled wiring for easy connection of the
overload, and is CSA approved. Pre-wired operator kits plug together for
trouble-free interconnection and
The Quick Connect Starter provides flexibilty at interchangeability. Pick up a Quick Connect
Starter today at your authorized Allen-
a cost that just might surprise you - ideal to
Bradley distributor - They are in stock!
meet the needs of todays industrial contractor.

Product Profile
General Ordering Information

HP
Amps 460 V 575 V Part Number
9 5 7.5 109-C09G-QC
12 7.5 10 109-C12G-QC
16 10 15 109-C16G-QC
23 15 15 109-C23G-QC
30 20 25 109-C30G-QC
37 25 30 109-C37G-QC

Kit Description Part Number


Start / Stop Push Button 198-QC-SSPB
Start / Stop Push Buttons & Pilot Light 198-QC-SSPBPL
Start / Stop Push Buttons & Pilot Lights (24 VAC) 198-QC-SSPBPL24
Start / Stop Push Buttons & 2 Pilot lights 198-QC-SSPB2PL
2 Position Selector Switch 198-QC-2SS
2 Position Selector Switch & Pilot Light 198-QC-2SSPL
3 Position Selector Switch 198-QC-3SS
3 Position Selector Switch & Pilot Light 198-QC-3SSPL
3 Position Selector Switch & Pilot Lights (24 VAC) 198-QC-3SSPL24
3 Position Selector Switch & 2 Pilot Lights 198-QC-SS2PL
Blank 198-QC-BLANK
Transformer 240 / 120 198-QC-240TX
Transformer 480 / 120 198-QC-480TX
Transformer 600 / 120 198-QC-600TX
Transformer 600 / 24 198-QC-600TX24

Starter Size Cat. No. Suffix Overload Relay Overload Relay


E1 Plus Overload Relay Bulletin 109 FLA Range Bulletin 193- Cat.
(Amps) No. Suffix
C09

C12

C16

C23

C30

C37

Selectable Trip Class (Electronic)


(10, 15, 20, 30) 0.1…0.5 193-EEAB
Selectable Manual/Auto- 0.2…1.0 193-EEBB
Manual Reset 1.0…5.0 193-EECB
3.2…16 193-EEDB
5.4…27 193-EEEB
5.4…27 193-EEED
9…45 193-EEFD
Note: If SMP Overload is used the 598-RA1 (Reset Kit) will be required. Reset depth will have to be adjusted.

Publication 109-PP001A-EN-P – June 2005 Copyright ©2005 Rockwell Automation, Inc. All Rights Reserved. Pr inted in Canada.