INTRODUCTION
Congratulations on the purchase of your Marine Air recapture and recycle or safely dispose of any such
Systems’ Vector Compact® air conditioner. No matter substances shall not be subject to the prohibition set
which of the following features was the reason for your forth in the proceeding sentence.”
purchase of this air conditioner, we are sure it will meet * Class I substances include CFC-12
your needs and will give you many years of efficient and ** Class II substances include HCFC-22
trouble free use. The Vector Compact self-contained
direct expansion air conditioners are designed for marine
applications incorporating the following features: Marine Air Systems
Marine Air Systems (MAS) is a product of Dometic
• Patented compact design with the condenser coil in Environmental Corporation. Dometic is a recognized
the evaporator shroud leader in the design and manufacture of high-perfor-
mance comfort control systems, refrigeration products
• High efficiency rotary compressor or scroll (24K)
and battery charging products for demanding environ-
compressors
ments, including commercial and recreational marine
• Cupronickel condenser coil craft, vehicles and other applications. We offer an
• Enhanced fin designed evaporator coil unparalleled scope of products, dealer networks, applica-
tions support, engineering resources and production
• 2" deep drain pan with multiple condensate drain capabilities throughout the world. Our team has many
locations years of experience in the design, manufacture, applica-
• Anti-vibration base pad tion and support of our products. Our practical experi-
ence and design capability allows our application
• Pre-charged and pre-wired systems for easy
engineers and sales representatives to offer optimum
connections
solutions for your environmental control requirements.
• Rotatable blower assembly Product lines also include well known Cruisair, Grunert,
• Charge Guard® ensures environmental protection and Sentry.
and system integrity
How It Works
This manual is intended to provide the information Your self-contained air conditioner consists of four main
necessary to ensure proper installation, operation, and components and a refrigerant gas circulating through the
maintenance of the unit. The figures that are referenced system. The BLOWER draws warm cabin air across the
throughout this manual can be found immediately after fins on the EVAPORATOR where the heat from the air is
the warranty section. Improper installation or misunder- transferred to the refrigerant in the evaporator coil. As
stood operating procedures can result in unsatisfactory the refrigerant evaporates from a liquid into a gas it
performance and/or premature failure of these units, so absorbs the heat from the cabin air. The COMPRESSOR
before proceeding please read this manual completely. then compresses the refrigerant gas and pumps it
through the outer tube in the CONDENSER COIL. The
The Vector Compact units are covered under the existing seawater pump circulates cool seawater through the
Dometic Environmental Corporation (Dometic) warranty inner tube in the condenser coil, this cools the refriger-
policy contained in this manual. In the interest of product ant and condenses it into a liquid. The heat from the
improvement, Dometic’s specifications and design are refrigerant is exchanged to the seawater and discharged
subject to change without prior notice. overboard. The liquid refrigerant is then passed through
the EVAPORATOR COIL and the cycle repeats. Remov-
ing heat from the cabin air lowers its temperature. The
Clean Air Act Amendments of 1990 cooled air is blown through the ducting and out the
[Title VI - Section 608(C-1)] supply air grille(s). For reverse cycle heating, the refriger-
“Effective July 1, 1992, it shall be unlawful for any ant flows in the opposite direction through the reversing
person, in the course of maintaining, servicing, repairing, valve. Heat is transferred from the seawater in the
or disposing of an appliance or industrial process condenser coil to the refrigerant and then to the air
refrigeration, to knowingly vent or otherwise knowingly blowing through the evaporator into the cabin. Seawater
release or dispose of any Class I* or Class II** sub- temperature will directly affect the a/c unit’s efficiency.
stance used as a refrigerant in such appliance (or This a/c unit can effectively cool your boat in water
industrial process refrigeration) in a manner which temperatures up to 90°F and heat in water temperatures
permits such substance to enter the environment. De as low as 40°F. See Figure 1.
minimis releases associated with good faith attempts to
L-2254 Introduction 4
❖ English
INSTALLATION
Unpacking and Inspection Notice
When the equipment is received, all items should be This component is charged with hydrochloro-fluorocarbon
carefully checked against the packing list to ensure all (HCFC) refrigerant R22. Effective July 1, 1992 it shall be
cartons have been received. Move units in the normal unlawful for any person to knowingly vent or otherwise
“up” orientation as indicated by the arrows on each knowingly release any class 1 (CFC) or class 2 (HCFC)
carton. Examine cartons for shipping damage, removing substance as a refrigerant in a manner which permits
the units from the cartons if necessary. If the unit is such substance to enter the atmosphere per the clean
damaged, the carrier should make the proper notation on air act of 1990. Public law 101-549 Title IV Section 608-
the delivery receipt acknowledging the damage. C. Failure to comply may result in severe penalties,
including fines and imprisonment.
CAUTION: When unpacking and installing the 3-knob
control (if mechanical option is used), care must be
Warning
taken not to kink or break the copper cap tube when
uncoiling the sensing bulb. The cap tube is hollow and To minimize the hazard of electrical shock and
kinking or sharp bends will inhibit system operation. personal injury, this component must be effectively
grounded. Refer to the installation guidelines for
further information.
Safety Considerations
VERY IMPORTANT: Never install your air conditioner
Caution
in the bilge or engine room areas. Insure that the
selected location is sealed from direct access to High compressor temperature is normal.
bilge and/or engine room vapors. Do not terminate Do not touch.
condensate drain line within three (3) feet of any
outlet of engine or generator exhaust systems, nor in Placement of System
a compartment housing an engine or generator, nor
Selecting a good location for your air conditioner is the
in a bilge, unless the drain is connected properly to a
most important part of your preparations. Be sure to
sealed condensate or shower sump pump.
consider the size of the area you are cooling, the air
Installation and servicing of this system can be hazard- distribution needs, and the size of the unit you have
ous due to system pressure and electrical components. chosen. Keeping in mind that cool air has a tendency to
When working on this equipment, always observe fall, it is highly recommended that you locate the supply
precautions described in the literature, tags and labels air grille as high as possible in the cabin. See Figures 2
attached to the unit. Follow all safety codes. Wear safety and 3.
glasses and work gloves and place a fire extinguisher
The Vector Compact unit should be installed as low as
close to the work area. The following is a summary of
possible, BUT NEVER IN THE BILGE OR ENGINE
the labels on the unit:
ROOM AREAS. INSURE THAT THE SELECTED LOCA-
TION IS SEALED FROM DIRECT ACCESS TO BILGE
Danger AND/OR ENGINE ROOM VAPORS. Installing the unit as
low as possible (such as under a V-berth, dinette seat or
Electrical shock hazard. Disconnect voltage at main
bottom of a locker) and ducting the supply air as high as
panel or power source before opening any cover.
possible, creates an ideal airflow condition. This type of
Failure to comply may result in injury or death.
installation will prevent short or premature cycling.
L-2254 Installation 6
❖ English
duct diameters and their corresponding supply and line and as close to the keel as possible in any
return air grille minimum area in square inches. If a application, but especially on a sailboat, to keep the
transition box is used, the total area of supply air ducts intake in the water when the boat heels over so that
going out of the box should at least equal the area of air does not get into the system. (See Figure 7 for
the supply duct feeding the box. To calculate the square proper installation.)
inch area of a round duct, multiply the radius by itself (r2)
and multiply that number by 3.1416(π). See Figure 8. The speed scoop intake must face forward and not be
shared with any other pump. A seawater strainer is
The following is a summary of proper ducting connections: mandatory between the shut off valve (seacock) and the
pump to protect the pump from any foreign matter.
1. Pull back the fiberglass insulation exposing the inner Failure to install a seawater strainer will void the
mylar duct hose. pump warranty. The seawater system should be in-
2. Slide the mylar duct hose around the mount ring until stalled with an upward incline from the speed scoop &
it bottoms out. seacock, through the strainer, to the inlet of the pump
and then up to the inlet of the a/c unit’s condenser coil.
3. Screw 3 or 4 stainless steel sheet metal screws The discharge from the a/c unit should then run to the
through the duct hose into the transition ring. seawater outlet thru-hull fitting which should be located
where it can be visually checked for water flow and as
Make sure to catch the wire in the duct hose with the
close as practicable to the waterline to reduce noise. All
heads of the screws. Do not use band clamps, as the
hose connections shall be secured by means of double/
hose will slide off.
reversed stainless steel hose clamps. Use teflon tape on
4. Wrap duct tape around the ducting and ring joint to all threaded connections. The following is a summary of
prevent any air leaks. the seawater system installation:
5. Pull the insulation back up over the mylar to the ring 1. Install the speed scoop thru-hull inlet as close to the
and tape this joint. keel and as far below the water line as possible, facing
forward. Bed the scoop with a marine sealant de-
6. Remove excess ducting and use the same connection
signed for underwater use.
method at the supply air grille.
2. Install a bronze, full flow seacock on the speed scoop
All ducting should:
thru-hull inlet.
• Be appropriately sized for each application. 3. Install a seawater strainer below the level of the pump
with access to filter.
• Run as smoothly and taut as possible.
• Have as few bends or loops as possible. 4. Mount the pump above the strainer and at least one
foot below the waterline.
• Be securely fastened to prevent sagging during boat
operation. 5. Connect the seacock and strainer with an uphill run of
reinforced marine grade hose.
• Have all excess ducting lengths trimmed off.
• Not be flattened or kinked. 6. Connect the discharge from the pump uphill to the
bottom inlet of the a/c unit’s condenser coil with 5/8"
• Insulated when located in high heat load areas (hull hose. Connect the discharge from the condenser coil
side, mechanical compartments, etc.). to the overboard discharge thru-hull fitting with 5/8"
• Be properly protected against potential damage hose.
when routed through open areas. 7. Avoid loops, high spots or the use of 90° elbows with
seawater hose (each 90° elbow is equivalent to 2.5' of
hose and a 90° elbow on the pump outlet is equivalent
Seawater Pump and Plumbing to 20' of hose).
Several guidelines should be followed during the installa-
8. Double clamp all hose connections with stainless steel
tion of the seawater system. Since the circulation pump
clamps, reversing the clamps.
is centrifugal and not self-priming, it must be mounted so
that it is always at least one foot below the water line 9. Use teflon tape on all threaded connections.
regardless of which tack the vessel is on. Pump may be
mounted horizontally or vertically, however the discharge 10. Connect all metallic parts in contact with seawater
must always be above the inlet. Pump head should be to the vessel’s bonding system including the
rotated toward the direction of water flow. Install the speed scoop inlet, strainer, pump and the air
seawater speed scoop intake as far below the water conditioner. Failure to do so will void warranty.
Field wiring must comply with ABYC electrical codes. Manual Control Panel (MCP)
Power to the unit must be within the operating voltage
range indicated on the data plate. Properly sized fuses
Installation
or HACR circuit breakers must be installed for branch The MCP should be located within cap tube length of the
circuit protection. See data plate for maximum fuse/circuit a/c unit. The 3 knob MCP is configured either vertically
breaker size (mfs) and minimum circuit ampacity (mca). (shown) or horizontally. The cut out size is 2.5" by 7.0",
All units must be effectively grounded to minimize the see MCP (Figure 6) for orientation. Once the cut out is
hazard of electrical shock and personal injury. made, carefully uncoil the copper cap tube with return air
sensor (copper bulb) and route the control wires and cap
The following are to be observed: tube through the hole and back to the a/c unit using
caution not to kink the cap tube. Mount the return air
1. AC (alternating current) grounding (green wire) must sensor into the clips provided with the Vector Compact
be provided with the AC power conductors and unit. If the return air sensor cannot be mounted on the
connected to the ground terminal (marked “GRND”) at evaporator coil, mount it behind the return air grille. The
the AC power input terminal block of the unit(s), per sensor must be mounted in the return air stream. Make
ABYC standard E-8, or equivalent. electrical connections according to the wiring diagram
found in the electric box and/or in this manual. See
2. Connections between the vessel’s AC system ground-
Figure 9.
ing conductor (green wire) and the vessel’s DC (Direct
Current) negative or bonding system should be made
as part of the vessel’s wiring, per ABYC standard E-9,
or equivalent.
L-2254 Installation 8
❖ English
Installation Checklist Electrical
(Review prior to installation) ❑ The wiring diagram is located in the electrical box. If
that diagram is damaged or if you need a copy, please
Note: Refer to the Elite and Passport I/O manuals call Dometic with the unit part number, serial number,
for installation and operation of those digital and wiring diagram number, all of which are located on
controls. the unit data plate.
❑ Shut off valve (sea cock) and speed scoop properly ❑ Control wires connected to terminal strip with captive
sealed and tight fork or ring terminals
❑ Seawater pump is at least one foot below water line ❑ Circuit breakers sized according to specifications on
and securely mounted the data plate label
❑ Strainer mounted below pump with access to filter ❑ Digital display cable is connected at both ends
❑ Double/reversed stainless steel hose clamps on all ❑ Pump Relay Panel (if used) has a dedicated circuit
hose connections breaker sized for the pump but not to exceed 20 amps
maximum.
❑ Teflon tape on all threaded connections
❑ Hose runs uphill from speed scoop and sea cock to Grilles and Ducting
strainer, pump and a/c unit, then downhill (if possible)
❑ Supply air grille mounted as high as possible
from a/c unit to overboard discharge
❑ Return air grille mounted as low and as close to the
❑ Water flowing freely from overboard discharge while
a/c unit as possible
pump is running
❑ Return air grille mounted away from bilge vapors or
❑ Pump relay panel, if used, must have its own circuit
exhaust fumes
breaker sized for the pump (20 amp max)
❑ Ducting is pulled taut, straight, smooth and properly
❑ All metal fittings should be bonded
connected with no excess
Mounting
❑ Not in engine room or bilge areas, must be sealed
away from exhaust or fumes
3. Turn on AC circuit breaker. If the seawater pump has ❑ Turn the system on.
its own circuit breaker, turn that on too. Or, if the pump ❑ Set the desired cabin temperature (set point).
is connected to a Pump Relay Panel (PRP), then turn
on that circuit breaker also. ❑ Check for a steady solid stream of water from the
overboard discharge.
4. Turn the SYSTEM SWITCH control knob to START;
this energizes the fan and seawater pump. Turn ❑ Verify that there is steady airflow out of the supply air
THERMOSTAT control knob to the coolest position by grille.
rotating fully clockwise. If system has reverse cycle,
❑ If the unit does not appear to be operating properly,
turn knob counter-clockwise for heat.
refer to troubleshooting guide lines.
5. Check for a steady solid stream of seawater from the
Note: Do not turn the unit off and immediately turn it
overboard discharge.
back on. Allow at least 30 seconds for refrigerant
6. Turn FAN SPEED control knob clockwise to highest pressure equalization.
setting for cooling or counter-clockwise for heating.
Fault: Water coil is iced in the heating Passport I/O Control: Reprogram parameter P-14.
mode. Note: After the compressor cycles off, the fan will
continue to run for 2 minutes in cool mode and 4
1. Seawater temperature is below 40°F. minutes in heat mode regardless of parameter
Shut down system to prevent damage to condenser. setting.
Allow coil to defrost.
Fault: Fan is not running but the
Fault: System runs continuously. compressor is.
Possible Reason/Correction Possible Reason/Correction
1. Set point temperature is improperly set: too low 1. Failed triac on Passport I/O circuit board.
for cooling or too high for heating. Send for repair or call local service technician (see
Raise or lower set point. back of book for a listing).
L-2254 Troubleshooting 12
❖ English
Fault: Fan runs continuously although it Fault: System runs continuously.
is set to cycle with compressor. Possible Reason/Correction
Possible Reason/Correction 1. Improper air sensor location.
1. Failed triac on Passport I/O circuit board. Verify display head location with criteria found in the
Send for repair or call local service technician (see control manual. Install alternate air sensor if neces-
back of book for a listing). sary.
1. Digital control programmed for heat or cool 1. High-pressure switch is open (in cooling) due
only. to improper seawater flow.
Elite Control: Press and release the Mode button Strainer or intake may be plugged, seacock may be
(bottom right corner of display) until the desired closed, check seawater hose for kinks or collapses.
mode LED is lit. Verify pump operation; check pump circuit breaker if
applicable.
Passport I/O Control: Reprogram parameter P-1.
2. High-pressure switch open (in heating) due to
2. "HPF" or "LPF" is displayed. improper airflow.
See below. Remove obstructions in return air stream. Clean air
filter and grille. Check for crushed or restricted
ducting, ducting must be as straight, smooth and
Fault: No heat. taut as possible.
Possible Reason/Correction If problem persists, reprogram Low Fan Speed Limit
for maximum value. Set P-2 to 55 for Elite or set P-3
1. Digital Control may be set to Electric Heat, not to 64 for Passport I/O. And, set the Reverse Fan
Reverse Cycle. Speeds During Heating Mode parameter to "rEF"
Elite Control: Reprogram parameter P-13 (P-12 for Elite or P-13 for Passport I/O), or manually
set fan speed to high.
Passport I/O Control: Reprogram parameter P-15
L-2254 Troubleshooting 14
❖ English
MAINTENANCE
Reversing Valves Return Air Filters
Reverse cycle units have a reversing valve; the valve Check the return air filter about once a month and clean
must be energized periodically to keep the internal parts as necessary. To clean the filter, remove it from the unit,
moving freely. To do this, switch the a/c unit into heat for rinse with water, air dry and reinstall.
a few seconds once a month.
Winterization
Seawater Strainer There are several methods of winterization, some of
Insure that your pump receives adequate seawater flow which work better than others. The four various methods
by regularly cleaning the strainer basket. Periodically employed using a 50/50 nonpolluting biodegradable
check the overboard discharge for a steady stream of antifreeze/water solution are:
water. Check seawater intake speed scoop for obstruc-
1. Pumping of antifreeze solution into the overboard thru-
tions. Make sure hoses are not looped, kinked or
hull fitting, and discharging through the intake thru-hull
crushed.
fitting.
L-2254 16
❖ English
DESCRIPTION OF FIGURES
Fig 1. Overview of Vector Compact
Fig 2. Placement of Vector Compact
Fig 3. Spacing Allowances & Unit Dimensions
Fig 4. Installation of Condensate Drain
Fig 5. Mounting Brackets
Fig 6. 3-Knob Control
Fig 7. Seawater Pump and Plumbing Configuration
Fig 8. Ducting and Grille Sizing
Fig 9. Wiring Diagrams for Mechanical Controls (VCM5-16 & 24K)
Fig 10. Wiring Diagrams for Mechanical Controls (VCM5-16HV & 24K 230V/3Ph)
Fig 11. Wiring Diagrams for Digital Controls (VCD5-16 & VCD/VHD 24K)
Fig 12. Wiring Diagrams for Digital Controls (VCD5-16HV & VCD/VHD 24K 460V/3Ph)
Fig 13. Wiring Diagrams for Digital Controls (VCD18K-HV & VCM18K-HV)
L-2254 17
❖ English
Fig 1. Overview of Vector Compact
L-2254
18
Fig 3. Spacing Allowances & Unit Dimensions
PROPRIETARY NOTE: THE INFORMATION CONTAINED REV DATE REVISION DESCRIPTION DWG APR
WITHIN THIS DOCUMENT IS THE PROPERTY OF DOMETIC
A 3/7/03 REVISED TABLE DIMS,CAD200-03 DRR RAP
CORPORATION. ANY ATTEMPT TO COPY OR DISTRIBUTE
WITHOUT WRITTEN CONSENT FROM DOMETIC B 3/28/03 REVISED DIMS & MODEL NUMBERS,CAD251-03 DKM RAP
CORPORATION SHALL BE CONSIDERED UNLAWFUL AND C 5/24/04 ADDED VCD/M18K/1-HV TO TABLE,CAD345-04 DRR RAP
CAN BE CONTESTED IN A COURT OF LAW.
D 7/15/05 ADDED 5KHV DIMS,REVISED TO /2 FROM /1,CAD428-05 DRR RAP
M1020049 D
REV
L-2254
19
Fig 4. Installation of condensate drain Fig 6. 3-Knob Control
L-2254
20
Fig 7. Seawater pump and plumbing configuration
Duct Diameter (in/mm) 4/102 5/127 6/152 6/152 7/178 7/178 8/203
Duct Area (sq in/cm) 12.6/81 19.6/126 28.3/183 28.3/183 38.5/248 38.5/248 50.3/325
R/A Grille (sq in/cm) 64/413 80/516 100/645 130/839 160/1032 200/1290 240/1548
S/A Grille (sq in/cm) 32/206 45/290 60/387 70/452 80/516 100/645 140/903
L-2254
21
Fig 9. Wiring Diagrams for Mechanical Controls (VCM5-16 & 24K)
L-2254
22
Fig 10. Wiring Diagrams for Mechanical Controls (VCM5-16HV & 24K 230V/3Ph)
L-2254
23
Fig 11. Wiring Diagrams for Digital Controls (VCD5-16 & VCD/VHD 24K)
L-2254
24
Fig 12. Wiring Diagrams for Digital Controls (VCD5-16HV & VCD/VHD 24K 460V/3Ph)
L-2254
25
Fig 13. Wiring Diagrams for Digital Controls (VCD18K-HV & VCM18K-HV)