CONTENTS
ASME Codes...........................................................................................................................................2-3
Seat Tightness Performance Standards................................................................................................. 4
Valve Selection Guide............................................................................................................................5-7
Sizing and Selection.............................................................................................................................8-11
General Information............................................................................................................................... 12
ASME CODES
The ASME (American Society of Mechanical Steam Boilers High Temperature Water to Steam Heat
Engineers) boiler and pressure vessel code Valve capacity must be selected to prevent the Exchanger
requirements for overpressure protection as boiler pressure from rising more than 5 psig Valve must be set at a pressure not greater
they relate to Kunkle products are as follows: [0.35 barg] above the MAWP. than 15 psig [1.0 barg] and with sufficient
capacity to prevent the pressure from rising
ASME Section I Hot Water Boilers more than 5 psig [0.35 barg] above the MAWP.
This code applies to boilers where steam or Safety valve must be set to relieve at a
other vapor is generated at a pressure greater pressure not greater than the MAWP of the ASME Section VIII and XIII - UV
than 15 psig [1.0 barg], high temperature water boiler. If more than one safety valve is used, This code applies to unfired pressure vessels
boilers intended for operation at pressures the secondary valve(s) may be set up to 6 psig with an inside diameter larger than 6 inches
exceeding 160 psig [11.03 barg] and/or [0.41 barg] above the MAWP for boilers with [130 mm] and designed for use above 15 psig
temperatures exceeding 250°F [121°C] and MAWPs up to and including 60 psig [1.0 barg]. Valve(s) must prevent the pressure
liquid phase thermal fluid heaters. [4.13 barg], and 5% for boilers with MAWPs from rising more than 10% or 3 psig [0.21 barg],
greater than 60 psig [4.13 barg]. Capacity must whichever is greater, above the MAWP. For a
Boiler Pressure Accumulation be selected to prevent the pressure from rising single valve installation, the set pressure may
No more than 6% above the highest pressure more than 10% above the MAWP if one valve not be greater than the MAWP. For multiple
at which any valve is set, or no more than 6% is used or 10% above the set pressure of the valve installations, the first valve cannot be set
above MAWP. highest set valve if more than one valve is used. higher than the MAWP, but the other valves can
be set up to 5% above the MAWP. The pressure
Set Pressure Tanks/Heat Exchangers High Temperature rise for multiple valve installations can be 16%
The set pressure of a one-valve installation Water-to-Water Heat Exchangers or 4 psig [0.27 barg], whichever is greater.
cannot be higher than the MAWP. The set Valve(s) must be set at a pressure not greater When the vessel is exposed to an external heat
pressure of the second or other valves in a than the MAWP and with sufficient capacity to source, such as fire, the pressure rise can be
multiple valve installation can be up to 3% prevent the pressure from increasing more 21% above the MAWP.
above the MAWP. The complete range of than 10% above the MAWP.
valve settings for multiple valve installations NOTE
cannot be greater than 10% of the highest set Steam to Hot Water Supply Information stated is for reference only. User should
pressure. For high temperature water boilers, Valve must be at least 1” [25 mm] diameter always refer to the current revision of the ASME BPVC.
this 10% range may be exceeded. with set pressure not greater than MAWP of
the tank.
ASME Section IV and XIII - HV
This code applies to steam boilers operating at
pressures not greater than 15 psig [1.0 barg] and
hot water heating boilers operating at pressures
not greater than 160 psig [11.03 barg] and/or
temperatures not greater than 250°F [121°C].
2
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
A
'V' applies to all ASME HEATING BOILER - SECTION IV - CODE 'HV'
S
M Section I valves Set Pressure
E
psig [barg] Set Pressure Tolerance Blowdown Overpressure
V 15 psig Steam 15 [1.0] ±2 psig 2 - 4 psig 5 psig
[±0.14 barg] [0.14 - 0.28 barg] [0.34 barg]
A
'HV' applies to all ASME Hot Water 15 - 60 [1.0 - 4.14] ±3 psig
S Section IV and XIII-HV
M [±0.21 barg] N/A 10%
E valves Hot Water 61 - 160 [4.20 - 11.0] ±5% N/A 10%
HV
3
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
API-527 STANDARD
Model Code Section Service Performance Standard
300, 600 I and VIII Steam API 527 - No visible leakage for 1 minute at 10% below
900, 6000 nameplate set pressure or 5 psig [0.35 barg] below
nameplate set pressure, whichever is greater.
6000 (O-ring seat) VIII Air/Gas API 527 - Bubble tight for 1 minute at 10% below
916/917 (soft seat) nameplate set pressure or 5 psig [0.35 barg] below
918/919 (soft seat) nameplate set pressure, whichever is greater.
910/912 VIII Air/Gas API 527 - D and E orifice: 40 bubbles/min, F through
911/913 J orifice: 20 bubbles/min at 10% below nameplate set
pressure or 5 psig [0.35 barg] below nameplate set
pressure, whichever is greater.
916/917 (soft seat) VIII Liquid API 527 - No leakage for 1 minute at 10% below
918/919 (soft seat) nameplate set pressure, or 5 psig [0.35 barg] below
nameplate set pressure, whichever is greater.
910/912 I and VIII Liquid API 527 - 10 cc/h for inlet sizes less than 1” or 10 cc/h/in
911/913 of inlet valve size for inlet sizes 1” and larger at 10%
928/929 below nameplate set pressure or 5 psig [0.35 barg]
below nameplate set pressure, whichever is greater.
4
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
X = Standard O = Optional
NOTES
1. Set pressures less than 15 psig [1.0 barg] are non-code only.
2. See also ASME Section VIII and XIII-UV steam valves for non-code steam applications.
5
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
X = Standard O = Optional
NOTES
1. Soft seat available on some models.
2. See also Section VIII air valves for non-code air/gas applications.
3. Set pressures less than 15 psig [1.0 barg] are non-code only.
4. Temperature limits of soft seats determine operating limits of valve.
5. SAE inlet thread available
6. V iton® and T eflon® are registered trademarks of the Chemours Company.
6
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
X = Standard O = Optional
NOTES
1. Set pressures below 15 psig [1.0 barg] are non-code only.
2. Temperature limits of soft seats determine operating limits of valve.
3. FM Approved only.
7
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
1. For Steam
A. To obtain lb/h for sizing, divide BTU (max. firing rate) by 1000.
To obtain kg/h for sizing, divided KW by 0.6461.
2. For Liquid
A. Liquid valves must be sized closely to actual flow; oversizing causes “chatter,” undersizing
causes high pressure.
B. Liquid relief valves are normally capacity rated at 25% overpressure. Refer to Catalog capacity
correction tables for 10% overpressure. ASME Section I and VIII and XIII-UV Liquid Valves are
rated at 10% overpressure.
3. For Air-Gas
A. Valves for cold or cryogenic temperatures (below -20°F [-29°C]) must be made from
bronze, brass, or stainless steel to avoid the brittleness found in other materials at these
temperatures. Many valves are offered with cryogenic materials as an option/extra.
If flow is expressed in actual volume, such as Conversions from one volumetric flow rate
CFM (cubic feet per minute) or ACFM (actual to another or to weight flow (and vice versa)
CFM) as is often done for compressors, where may only be done when the volumetric flow is
the flow is described as displacement or swept expressed in the standard conditions shown
volume, the flow may be converted to SCFM above. If flows are expressed at temperature
as follows (or from flow expressed in m3/h to or pressure bases that differ from those listed
Nm3/h). above, they must first be converted to the
standard base.
or
Where: Where:
p = gauge pressure of gas or vapor in psig p = gauge pressure of gas or vapor in barg
t = temperature of gas or vapor in °F t = temperature of gas or vapor in °C
CONVERSION FORMULAS
Degrees Fahrenheit (°F) Degrees Celsius (°C)
F + 459.67 = R (Rankine) C + 273.15 = K (Kelvin)
(F - 32) x 0.556 = C (Celsius) (C x 1.8) + 32 = F (Fahrenheit)
8
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
SIZING
PHYSICAL PROPERTIES
M k C
Gas or Vapor Molecular Weight Specific Heat Ratio Gas Constant
Air 28.97 1.40 356
Ammonia, Anhydrous 17.03 1.31 348
Butane-n (Normal Butane) 58.12 1.09 326
Carbon Dioxide 44.01 1.29 346
Carbon Monoxide 28.01 1.40 356
Dowtherm A 165.00 1.05 321
Dowtherm E 147.00 1.00 315
Ethane 30.07 1.19 336
Ethylene (Ethene) 28.05 1.24 341
Helium 4.00 1.67 378
Hydrogen 2.02 1.41 357
Methane 16.04 1.31 348
Natural Gas (specific gravity = 0.60) 17.40 1.27 344
Nitrogen 28.01 1.40 356
Octane 114.23 1.05 321
Oxygen 32.00 1.40 356
Propane 44.10 1.13 330
Steam 18.02 1.31 348
9
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
SIZING
For capacities of super heated steam, multiply saturated steam capacity by correction factor below.
10
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
SIZING
For capacities of super heated steam, multiply saturated steam capacity by correction factor below.
11
KUNKLE SAFETY AND RELIEF PRODUCTS
DATA SUPPLEMENT
GENERAL INFORMATION
VCTDS-00396 © 2017, 2022 Emerson Electric Co. All rights reserved 05/22. Kunkle Valve is a mark owned by one of the companies in the Emerson Automation Solutions
business unit of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective
owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without
notice.
Emerson Electric Co. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of
any Emerson Electric Co. product remains solely with the purchaser.
Emerson.com
12