You are on page 1of 9

DeatschWerks has performed extensive testing of their fuel pumps at a wide range of pressures and voltages.

This
characterizes the performance of the pump over all possible operating conditions. Pump charaterization data can be
especially useful to customers designing demand-regulated returnless fuel systems. Only DW offers such extensive

Data from each pump model is contained in its own tab within this excel document.

All DW pumps are rated at 13.5v@40psi. On each tab, this data has been highlighted in orange for easy identificatio

PRV activation can be influenced by voltage. Therefore, PRV activation point data has also been included for each p

Contact techsupport@deatschwerks.com for further assistance in application of this data.


DW100 Fuel Pump Characterization
PN: 9-101
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 1.9 2.1 2.5 3.0 3.4 3.8 4.2 0.0 0.0 0.0 0.0 0.0 0.0

FLOW 174 158 131 110 88 60 19 0 0 0 0 0 0 NA

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 2.5 2.6 3.1 3.5 3.9 4.3 4.7 5.1 5.5 0.0 0.0 0.0 0.0

FLOW 214 201 177 157 135 117 95 69 31 0 0 0 0 NA

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 3 3.2 3.6 3.9 4.2 4.6 5.0 5.4 5.8 6.2 6.6 0.0 0.0

FLOW 238 226 204 180 165 140 120 100 80 55 25 0 0 NA

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 3.1 3.4 3.8 4.2 4.5 4.9 5.3 5.7 6.1 6.5 6.9 0.0 0.0

FLOW 253 240 218 198 179 160 143 125 105 80 43 0 0 NA

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 3.9 4.1 4.5 4.9 5.2 5.7 6.0 6.4 6.7 7.1 7.5 7.8 7.8

FLOW 289 281 262 242 226 208 188 170 152 131 111 82 82 105

18 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 4.6 4.8 5.1 5.5 5.9 6.2 6.6 6.9 7.3 7.7 8.1 8.4 8.4

FLOW 324 315 295 274 258 241 224 206 189 170 149 123 123 95

NOTES
This pump is not reccomended for use above 18 volts. Use at higher voltages may result in pump failure.
Tested 12-4-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.
DW200 Fuel Pump Characterization
PN: 9-201
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 4.6 4.8 5.4 5.9 6.5 7.0 7.5 8.3 8.9 9.5 10.1 10.6 11.2

FLOW 230 212 192 172 153 136 120 100 65 60 45 27 12 NA

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 6.1 6.2 6.7 7.2 7.9 8.3 8.9 9.6 10.2 10.7 11.4 11.9 12.4

FLOW 281 260 236 218 202 185 170 156 142 128 113 92 79 NA

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 7.5 7.6 8.1 8.6 9.2 9.7 10.4 10.9 11.6 11.9 12.7 13.1 13.6

FLOW 315 301 278 265 255 240 225 210 190 170 155 140 125 130

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 7.7 7.8 8.2 8.8 9.3 9.9 10.6 11.2 11.8 12.1 12.9 13.3 13.8

FLOW 323 307 288 270 255 240 224 207 194 180 165 151 137 130

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 9.2 9.1 9.4 9.7 10.3 10.9 11.6 12.1 12.6 12.9 13.5 14.0 14.6

FLOW 16 356 337 321 306 291 275 261 245 232 218 207 192 125

18 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 10.6 10.3 10.7 10.7 11.3 12.0 12.6 13.0 13.5 13.8 14.3 14.7 15.4

FLOW 418 400 378 356 340 334 322 305 290 273 259 244 234 125

Notes
This pump is not reccomended for use above 18 volts. Use at higher voltages may result in pump failure.
Tested 12-4-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.
DW65c Fuel Pump Characterization
PN: 9-651, 9-652
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 7 6.9 7.4 7.9 8.5 9.1 9.8 10.4 11.0 11.7 12.4 13.2 13.8

FLOW 244 224 203 186 170 152 142 122 101 84 63 40 5 115

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 8.5 8.5 9.1 9.6 10.1 10.6 11.2 11.8 12.4 13.1 13.7 14.3 14.3

FLOW 289 273 259 241 226 211 201 181 159 143 126 107 5 115

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 9.5 9.8 10.3 10.8 11.4 11.9 12.6 13.2 13.8 14.2 14.6 15.2 15.4

FLOW 324 314 296 280 265 250 235 220 210 190 170 158 0 115

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 10 10.3 10.8 11.2 11.7 12.2 12.7 13.2 13.8 14.4 15.0 15.6 15.6

FLOW 333 325 308 292 277 261 252 231 211 194 178 159 0 115

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 11.7 11.9 12.4 12.9 13.4 13.9 14.3 14.8 15.4 16.0 16.6 17.1 17.1

FLOW 370 367 351 337 324 308 299 279 259 242 227 204 0 115

18 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 13.4 14.1 14.6 15.1 15.8 16.2 16.6 17.2 17.7 18.1 18.7 18.7 18.7

FLOW 411 412 397 385 373 357 348 329 307 292 271 0 0 105

NOTES
This pump is not reccomended for use above 18 volts. Use at higher voltages may result in pump failure.
Tested 12-17-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.
DW65v Fuel Pump Characterization
PN: 9-654, 9-655
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 4.9 5.3 5.6 6.4 7.2 8.0 8.8 9.6 10.3 11.1 11.8 12.2 12.2

FLOW 229 215 194 169 148 126 104 81 56 37 18 2.5 0 open

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 6.6 7.1 7.3 7.9 8.7 9.5 10.2 11.0 11.6 12.2 12.9 13.6 14.2

FLOW 282 272 255 235 216 197 177 158 143 120 110 97 84 160

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 7.9 8.5 8.7 10.0 10.5 11.2 11.5 12.2 12.7 13.4 14.1 15.1 15.6

FLOW 317 319 299 280 265 250 235 215 200 180 165 152 137 160

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 8.5 8.9 9.7 10.4 11.2 11.9 12.7 13.3 13.9 14.4 15.0 15.6 16.3

FLOW 331 327 319 292 274 256 245 227 211 192 176 163 147 160

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 10.4 11.0 11.4 12.4 13.0 13.8 14.5 15.1 15.7 16.4 17.0 17.7 18.3

FLOW 369 372 351 335 315 300 289 273 257 240 227 211 197 160

18 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 12.9 13.1 13.8 14.5 15.1 16.1 16.7 17.2 18.2 18.8 19.4 20.2 20.7

FLOW 411 409 395 378 365 355 336 321 315 301 284 268 254 160

NOTES
This pump is not reccomended for use above 18 volts. Use at higher voltages may result in pump failure.
Tested 12-3-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.
DW300 Fuel Pump Characterization
PN: 9-301
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 6.9 6.9 7.5 8.2 8.8 9.4 10.1 10.7 11.3 11.9 12.6 12.6 12.6

FLOW 324 295 269 247 223 201 174 152 126 85 47 47 47 NA

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 8.6 8.8 9.3 9.9 10.5 11.1 11.8 12.5 13.2 15.8 14.4 14.9 15.7

FLOW 378 354 331 311 290 270 247 228 208 185 156 112 70 NA

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 10 10.4 11.0 16.7 17.3
11.2 11.7 12.3 12.9 13.5 14.1 14.7 15.4
FLOW 440 419 397 179 154 125
360 340 320 295 275 260 240 220

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 10.5 11.2 11.7 12.3 12.8 13.3 14.0 14.5 15.2 15.7 16.4 17.2 17.9

FLOW 428 420 400 382 364 348 328 313 296 279 252 224 196 125

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 12.7 13.5 13.9 14.5 14.9 15.3 15.8 16.3 16.8 17.4 17.9 18.5 19.2

FLOW 479 475 454 438 421 407 389 376 366 346 326 294 261 125

18 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 14.8 14.9 15.5 15.9 16.5 17.0 17.4 17.9 18.5 19.0 19.4 20.0 20.8

FLOW 509 507 494 480 465 458 440 429 426 413 388 355 330 125

20 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 16.7 16.3 17.0 17.5 18.2 18.9 19.4 20.1 20.6 21.2 21.6 22.2 22.9

FLOW 518 513 506 503 504 502 493 489 486 472 453 425 378 120

NOTES
This pump is not reccomended for use above 20 volts. Use at higher voltages may result in pump failure.
PRV did not open at 10v and 12v.
Tested 12-4-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.
DW300c Fuel Pump Characterization
PN: 9-307, 9-309
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 6.2 6.5 7.2 7.8 8.5 9.2 9.9 10.6 11.2 11.9 12.7 13.4 14.2

FLOW 322 305 275 254 232 208 185 163 145 123 104 82 57 NA

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 8.1 8.4 8.9 9.7 10.3 11.0 11.6 12.3 13.0 13.6 14.2 14.9 15.5

FLOW 378 357 334 315 293 273 252 232 210 190 172 151 131 NA

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 9.6 9.7 10.6 11.2 11.7 12.3 12.9 13.5 14.1 14.7 15.4 16.2 16.8

FLOW 411 396 379 360 340 320 295 275 260 240 220 195 176 125

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 10.2 10.3 10.9 11.5 12.1 12.8 13.4 14.1 14.6 15.3 16.0 16.7 17.4

FLOW 422 408 387 368 349 327 308 287 270 249 229 210 190 125

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 12 12.6 13.3 13.9 14.6 15.1 15.7 16.2 16.8 17.3 18.0 18.7 19.1

FLOW 461 458 445 428 408 389 372 352 336 315 296 273 251 125

NOTES
This pump is not reccomended for use above 16 volts. Use at higher voltages may result in pump failure.
Tested 12-4-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.
DW300m Fuel Pump Characterization
PN: 9-305
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 5.9 6.1 6.9 7.5 8.2 9.0 9.7 10.4 11.1 11.9 12.7 13.4 14.2

FLOW 330 293 267 242 219 196 172 148 128 107 87 67 44 NA

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 7.6 8.0 8.7 9.4 10.0 10.7 11.4 12.0 12.8 13.8 14.6 15.3 15.9

FLOW 375 357 330 306 285 266 243 222 200 180 157 138 119 NA

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 9.4 9.5 10.2 10.7 11.2 11.8 12.4 13.1 13.7 14.2 14.9 16.4 17.2

FLOW 390 390 372 355 340 315 290 270 250 230 210 188 167 125

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 9.8 10.3 10.7 11.4 11.9 12.6 13.2 13.7 14.6 15.1 15.6 16.7 17.4

FLOW 391 392 381 365 343 324 307 285 268 245 225 203 182 125

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 10.6 11.9 12.7 13.4 14.2 14.5 15.1 15.6 16.3 16.9 17.4 18.2 19.0

FLOW 316 327 376 377 377 372 353 335 322 299 279 259 242 125

NOTES
This pump is not reccomended for use above 16 volts. Use at higher voltages may result in pump failure.
Tested 12-4-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.
DW400 Fuel Pump Characterization
PN: 9-401, 9-402, 9-403
Flow and Amps VS Voltage and Pressure

10 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 9.3 9.7 10.6 11.6 12.4 13.1 13.9 14.8 15.4 16.4 17.1 17.8 18.5

FLOW 385 365 334 310 289 270 251 231 215 197 179 160 140 125

12 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 11.9 12.3 13.1 13.9 14.7 15.4 16.0 16.8 17.3 18.4 19.1 19.9 20.6

FLOW 447 433 407 383 361 342 323 303 288 271 253 238 218 125

13.5 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 14.0 14.2 15.1 15.8 16.5 17.0 17.7 18.6 19.3 20.1 20.8 21.6 22.4

FLOW 505 483 457 440 415 405 390 370 350 340 320 290 275 125

14 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 14.7 15.0 15.8 16.6 17.2 17.7 18.3 19.1 19.7 20.7 21.4 22.3 23.1

FLOW 517 500 478 455 436 416 399 377 362 342 325 309 291 125

16 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 17.6 18.0 18.6 19.3 20.1 20.6 21.1 21.8 22.4 23.4 24.2 25.0 25.7

FLOW 586 569 549 530 510 493 476 455 437 417 402 385 369 130

18 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 20.9 21.1 21.7 22.4 23.2 23.6 24.2 24.8 25.3 26.4 27.1 27.9 28.7

FLOW 651 642 623 602 585 568 552 531 514 490 474 455 438 130

20 volts

PSI 0 10 20 30 40 50 60 70 80 90 100 110 120


PRV
AMP 24.1 24.5 25.0 25.7 26.5 26.9 27.3 28.1 28.5 29.5 30.2 30.9 31.7

FLOW 712 712 693 674 659 640 625 602 588 563 541 525 507 130

NOTES
This pump is not reccomended for use above 20 volts. Use at higher voltages may result in pump failure.
Tested 12-17-18
PRV = pressure release valve. An integrated safety device on all in-tank pumps. Pump output significantly decreases upon activation of PRV. Working pressure should be kept below PRV activation
point.

You might also like