Professional Documents
Culture Documents
Tuan BV
Motor V-belt side-Radial vertical
Indication misalignment V-belt or eccentricity
pulleys
v [mm/s ] Generate high peak value at 1x motor & 1x fan
FAN \Motor\1 V\1 0 3 Ma ch. s pe ctr. >6 0 0 1 4 -Jun-1 0 3 :5 0 :4 4 PM
20
(100.28) BPFO
(144.72) BPFI
(130.54) BSF
(10.02) FTF
(24.50) 1X
19
18
17
16
15
14
1X fan
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-1
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
f [Hz]
2
Holcim Vietnam Name of Presentation/Event 06/02/21/ZKH/AnhDV
Filename.ppt
Motor V-belt side-Vertical horizontal
v [mm/s] FAN\Motor\1 H \10 3 Ma ch. s pectr. >60 0 0 4-Ma r-0 9 1:4 9:5 0 PM
50
45
40
35
30
25
Peak value increased after
20
After realignment V-belt maybe by the
tension
15
10
5 17-Mar-10
Before
0 27-Jan-10
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
f [Hz]
3
Holcim Vietnam Name of Presentation/Event 06/02/21/ZKH/AnhDV
Filename.ppt
Fan radial vertical NDE-Velocity
v [mm/s] FAN \Fa n\3 V\1 0 0 2 Ma ch. s pe ctr. >6 0 0 2 7 -Ja n-1 0 2 :4 7 :1 8 PM
10.0
9.5
9.0
8.5
8.0
7.5 Peak value increased but
7.0 may not serious
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5 14-Jun-10
2.0
1.5 19-Mar-10
1.0
17-Mar-10
0.5
0.0 27-Jan-10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
f [Hz]
4
Holcim Vietnam Name of Presentation/Event 06/02/21/ZKH/AnhDV
Filename.ppt
Fan radial vertical NDE-Acceleration
a [m/s ²] FAN \Fa n\3 V\1 0 0 3 R olling be a ring > 1 2 0 2 7 -Ja n-1 0 2 :4 7 :3 8 PM
20
19
18
17
16
15
14
13 Peak value increased more
12
serious 1X, 2X, 3X…
11
10
9
8
7
6
5
4
14-Jun-10
3
2 19-Mar-10
1
0 17-Mar-10
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
f [Hz]
Main reason is due to tension of the belt associate with eccentricity??
60
55
50
45
40
35
30
25
20
15
10
5
0
13-Aug-08 24-Sep-08 05-Nov-08 17-Dec-08 28-Jan-09 11-Mar-09 22-Apr-09 03-Jun-09 15-Jul-09 26-Aug-09 07-Oct-09 18-Nov-09 30-Dec-09 10-Feb-10 24-Mar-10 05-May-10 16-Jun-10
date