Solution Overview of MPSII

Note: Do not support to replace power module, chassis or PEP separately. If needed, MPSIII system(the 3 parts mentioned in r
MPSIII
Type of Rack Power supply
Description

PHARPS32000000

PHARPS32010000
Power Module

PHARPS32200000

PHARPSCH100000, POWER SUPPLY


CHASSIS

Chassis

PHARPSCH100000, POWER SUPPLY


CHASSIS

PHARPSPEP21013 for PAPG CN,


DUAL CHASSIS, 120/240 VAC

PHARPSPEP21023 for PAPG CN,


DUAL CHASSIS, 120/240 V AC &
PEP 125 VDC

PHARPSPEP22003 for PAPG CN,


DUAL CHASSIS, 125 VDC &DC
PHARPSFAN03000,FAN, SYSTEM
FAN
MONITORING AN
1948506C8,SYS POWER BUS
DC BUS
BAR,DC

ABB P/N and CNBBC P/N Cross reference:


ABB Number Description
2VAA008278R001 SPS01, 24V@10A;
2VAA008279R001 SPS02, 48V@5A;

2VAA008280R001 SPS03-5V, +5V@60A;

2VAA008281R001 SPS03-15V, +15V@3A, -15V@3A


8VZZ001720Z0001 SPS04, 125VDC@2.3A

2VAA008282R101 BP01-L, Left Base of two SPS01 or


SPS02
BP01-M, Middle Base of two SPS01
2VAA008282R201 or SPS02
BP01-R, Right Base of two SPS01 or
2VAA008282R301 SPS02
BP03, Base of two SPS03-5V and two
2VAA008283R101
SPS03-15V
8VZZ001719Z0001 BP04, Base of two SPS04
2VAA008284R101 BP-K01-AA, Installation accessory for
SPS base and module, including two
metal sheets 485 mm by 240 mm,
two AC MCBs, cables for BP  01 and
BP03 to DC bus bar and power input

2VAA008284R201 BP-K01-AD, Installation accessory for


SPS base and module, including two
metal sheets 485 mm by 240 mm,
one AC and one DC MCB, cables for
BP  01 and BP03 to DC bus bar and
power input

2VAA008284R301 BP-K01-DD, Installation accessory for


SPS base and module, including two
metal sheets 485 mm by 240 mm,
two DC MCBs, cables for BP  01 and
BP03 to DC bus bar and power input

2VAA008285R101 MPS04K01, one pair of SPS03-5V,


SPS03-15V,SPS01,SPS02, and one
BP01-L, BP01-R, BP03, BP-K01-AA

2VAA008285R001 / 3VCN-8409 MPS04K01 BOM Contents (Typical HUB CN solution's configuration)


QTY.
SPS01, 24V@10A; 2
SPS02, 48V@5A; 2
SPS03-5V, +5V@60A; 2
SPS03-15V, +15V@3A, -15V@3A 2
BP01-L, Left Base of two SPS01
or SPS02 1
BP01-R, Right Base of two SPS01
or SPS02 1
BP03, Base of two SPS03-5V and
two SPS03-15V 1
BP-K01-AA, Installation accessory
for RACK SPS 1
Total Cost
Solution Overview of MPSIII vs MPSIV, 20190922
or PEP separately. If needed, MPSIII system(the 3 parts mentioned in red font) shall be replaced as a whole set by MPSIV set
MPSIII MPSIV
Qty Description
SPS03-5V, +5V@60A;
POWER SUPPLY, 5V @ 60A, +15V @ 3A, -15V @ SPS03-15V, +15V@3A, -15V@3A
1
3A, 24V @ 17A
SPS01, 24V@10A;
SPS03-5V, +5V@60A;
POWER SUPPLY, 5V @ 60A, +15V @ 3A, -15V @ SPS03-15V, +15V@3A, -15V@3A
1
3A, 24V @ 17A, 125V @ 2 A SPS01, 24V@10A;
125VDC output module
SPS03-5V, +5V@60A;
POWER SUPPLY, 5V @ 60A, +15V @ 3A, -15V @ SPS03-15V, +15V@3A, -15V@3A
1
3A, 24V @ 17A, 48V @ 8.5A SPS01, 24V@10A;
SPS02, 48V@5A;
BP01-L, L Base of two SPS01 or
SPS02
BP01-M, M Base of two SPS01 or
SPS02
(when installing PHARPS32000000) 1
BP01-R, R Base of two SPS01 or
SPS02
BP03, Base of SPS03-5V and SPS03-
15V
BP01-L, L Base of two SPS01 or
SPS02

(when installing PHARPS32200000 with 48VDC BP04, Base of two SPS04


output; or installing PHARPS32010000 with 1
125VDC output) BP01-R, R Base of two SPS01 or
SPS02
BP03, Base of SPS03-5V and SPS03-
15V

BP-K01-AA, installation accessory


1 for RACK SPS

BP-K01-AD, installation accessory


1
for RACK SPS

BP-K01-DD, installation accessory


1
for RACK SPS
PHARPSFAN03000,FAN, SYSTEM
1
MONITORING AN
1948506C8,SYS POWER BUS
1
BAR,DC

P/N
3VCN-6714
3VCN-6715

3VCN-8334

3VCN-8333
8VCN000222Z0001

3VCN-6718

3VCN-6717

3VCN-6716

3VCN-8332

8VCN000222Z0002

3VCN-8331

Deleted: it could only be reference to understand or caculate set/

(Typical HUB CN solution's configuration)


s a whole set by MPSIV set
MPSIV
Comments
P/N Qty
3VCN-8334 1
3VCN-8333 1
3VCN-6714 1
3VCN-8334 1
3VCN-8333 1
3VCN-6714 1
8VCN000222Z0001 1
3VCN-8334 1
3VCN-8333 1
3VCN-6714 1
3VCN-6715 1
3VCN-6718 1

3VCN-6717 Quantity of BP01 could be added or


reduced according to different 24/48V
3VCN-6716 load

3VCN-8332 1

3VCN-6718 1

1 if using
8VCN000222Z0002 PHARPS32010000 Quantity of BP01 could be added or
reduced according to different 24/48V
1 if using load
3VCN-6716
PHARPS32200000

3VCN-8332 1

including two metal sheets 485 mm by


240 mm, two AC MCBs, cables for
3VCN-8331 1 BP01 and BP03 to DC bus bar and
power input
BP-K01-AD, Installation accessory for SPS
base and module, including two metal
sheets 485 mm by 240 mm, one AC and
1 one DC MCB, cables for BP  01 and BP03
to DC bus bar and power input

BP-K01-DD, Installation accessory for SPS


base and module, including two metal
sheets 485 mm by 240 mm, two DC
1 MCBs, cables for BP  01 and BP03 to DC
bus bar and power input
Suggest to use one in MPSIV for RACK,
1
but not need for SDIN

1 Still needed in MPSIV

reference to understand or caculate set/kits concept and pricing comparison:


2VAA008284R101 BP-K01-AA BOM 2020.9.21, components must pass C

CNBBC SAP P/N Description qty.


BP-K01-P1, rear plate, 2mm CRC steel, 485mm*240mm 1
BP-K01-P2, front plate, 2mm CRC steel, 485mm*240mm 1
YZX420RG1, 2AWG or 35mm2 cable, Orange 1
YZX420RG2, 2AWG or 35mm2 cable, Black 1
YZXCOM, >=4 mm2 cable, gray 1
YZX25R, 4*2.5mm2 cables 1
YZX10REC, rectangel connector cable, 2*5Pin 1
14 AWG or 2 mm2 green/yellow wire, 1000mm 1
14 AWG or 2 mm2 green/yellow wire, 1500mm 1
DIN rail, H=7.5mm, W=140mm 1
EK4/35, GND Terminal 4
EW35, End Terminal 2
YZX25RD1, double 3*2.0 mm2, 550mm & 450mm length 1
YZX25RD2, double 3*2.0 mm2, 550mm & 450mm length 1
YZXALM, rectangel connector cable, 2*1Pin 1
Cage nut, M5 14
M5*16, pan head screws, thread forming, with lock washer 40
Bolts kits as below picture 4
ABB MCB, S202-K25 2

Remark:
Equivalent M5 Cage Nut picture:

Equivalent Bolts kits picture:


M 2020.9.21, components must pass CE/UL/CSA certification

Comments

+5V connection
MCOM connection
MCOM and IOCOM connection
+24V/IOCOM connection
BP03 base to DC-BUS
Grounding EK4/35 to chassis ground STUD, one end with H2.5/14D, Weidmueller
Grounding BP to chassis ground STUD, one end with H2.5/14D, Weidmueller
install S202 MCB
Groundting Terminal
For above DIN components installation and MCB spacing
LINE1 L/N input cables, from MCB-->BP03+BP01 base
LINE2 L/N input cables, from MCB-->BP03+BP01 base
Alarm cable for BP01
Rittal 7187.137 or equivalent
GB9074.4_88 M5X16 ZC, have lockwasher. Used with cage nut and BP01/BP03
M6 washer (copper), M6×10 screw (copper) 104878, and M6×10 nut (copper)
For AC + AC input