TECHNICAL MANUAL

PORTABLE TEST SET


MODEL TS100

FEBRUARY 20, 1997


REV 02

SEACOM DIVISION

DUKANE CORPORATION ST. CHARLES, ILLINOIS 60174 PHONE: 630/584-2300 FAX: 630/584-5154
DOCUMENT NO. 03-TM-0014
Table Of Contents
SECTION PAGE
I General Information...................................................................................................... 1
1.1. Introduction.................................................................................................... 1
1.2. Description...................................................................................................... 1
1.3. Specifications.................................................................................................. 1

II Operation....................................................................................................................... 2
2.1. Operation........................................................................................................ 2
2.2. Testing............................................................................................................ 2

III Maintenance............................................................................................................... 4
3.1. Cleaning.......................................................................................................... 4
3.2. Battery Replacement....................................................................................... 4
3.3. Calibration...................................................................................................... 4

APPENDIX

A Beacon Service...................................................................................................... 5
A.1. DK120 Series................................................................................................. 5
A.2. DK100 Series................................................................................................. 5
A.3. DK100/DK120 Warranty................................................................................ 6
A.4. DK100/DK120 Service Program.................................................................... 7
A.4.1. Beacon Return-Defective Electronics............................................... 7
A.4.2. Beacon Return-Defective Battery..................................................... 7
A.4.3. Beacon Return-NO Problem............................................................ 7
A.4.4. Beacon Return-Out of Warranty....................................................... 7
A.4.5. Battery Change/Recertification........................................................ 7
A.5 Procedure for Returning Beacon to Factory................................................... 8
A.5.1. Beacon Service................................................................................ 8
A. Packaging................................................................................... 8
B. Information to be Included With Beacon.................................... 8
C. Return Authorization.................................................................. 8
D. Shipping Instructions.................................................................. 8
A.5.2. Battery Change/Recertification........................................................ 8
A. Packaging................................................................................... 8
B. Procedure- Customer.................................................................. 8
C.Procedure-Dukane....................................................................... 8

Figures

Figure 1.1. TS100 Portable Test Set............................................................................. 1


Figure 2.1. Probe Head Replacement............................................................................ 2
Figure 3.1. Battery Replacement................................................................................... 4

03-TM-0014 REV 02 PAGE i of i


SECTION I
GENERAL INFORMATION

1.1. INTRODUCTION. This manual contains Cradle Mount or the N30A20A Strap Mount.
the description and operation of the TS100 Port- Note: The TS100 will not test any Beacon
able Test Set manufactured by Dukane Corpora- equipped with a Time Delay, even if screw is set
tion, Seacom Division, 2900 Dukane Drive, St. in the ND (No Delay) position.
Charles, Illinois 60174 USA. See Figure 1.1. Ideally, confirming proper operation of an
Appendix A outlines the service procedures for installed aircraft beacon is the primary purpose of
the DK120 Series Beacons as well as the War- the TS100. If a non-operational beacon, an im-
ranty, Service Program and Beacon Return Pro- properly operating beacon or a beacon with low
cedures for the DK100 Series Underwater battery voltage is tested, the TS100 will alert the
Acoustic Beacons. user of the TS100 about or to the specific prob-
lem so corrective action can be taken.
1.2. DESCRIPTION. The TS100 Portable Test
Set is a microprocessor controlled, battery oper- 1.3. SPECIFICATIONS. The specifications
ated test set designed primarily for performing the for the TS100 are listed below:
required functional testing of beacons in the shop
or on the aircraft and to verify operation of the Size Housing.......................8.3" (21.1 cm) x 4.0"
installed beacon. Portability allows the user to (10.2 cm) x 1.8" (4.6 cm)
test a wide variety of aircraft beacons while the Size Probe Head....................2.9" (7.4 cm) x 2.0"
beacon is still mounted to the airframe or the air- (5.1 cm) x 1.8" (4.6 cm)
crafts' flight recorders. The TS100 Portable Test Weight..............................17 ounces (482 grams)
Set can test the DK120 and the DK100 Series Battery..............Four 1.5V "AA" NEDA MN1500
Beacons mounted in either the N30A26 Series Compatible Beacons........................DK100 Series
DK120 Series

Figure 1.1. TS100 Portable Test Set.

03-TM-0014 REV 02 Page 1 of 8


SECTION II
OPERATION

2.1. OPERATION. "OPEN PROBE/BATT." - This message will be


2.1.1. The TS100 probe head attaches to the displayed under two conditions.
beacon mount as outlined in Figure 2.1. To con-
nect the probe head, rotate the probe knob coun- 1) Probe head is not connected or improp-
terclockwise to retract the testing probe. Place erly
the assembly over the water-switch end of the connected.
beacon. Make sure that the end of the probe head 2) Beacon battery is dead.
is fully seated on the beacon and making good
contact with the beacon case. Rotate the probe "BEACON PASSED" - The beacon is operating
knob so that the testing probe comes in contact properly and the battery is within the acceptable
with the water-switch pin. (Note: The TS100 can voltage limits.
be used with either the N30A26 Series Cradle
Mount or the N30A20A Strap Mount.) "BATTERY FAULT" - The beacon battery volt-
age is below the minimum acceptable voltage
limit for proper operation. Remove the beacon
from service according to Appendix A.

"NO PULSE OUTPUT" - The beacon has no


pulse output and is not operating. Remove the
beacon from service according to Appendix A.

"PULSE FAULT" - The pulse output of the bea-


con is too slow. Remove the beacon from service
according to Appendix A.

"FREE-RUN FAULT" - Beacon is continuously


operating without the external waterswitch being
Figure 2.1. Probe Head Placement. shorted. Remove the beacon from service ac-
cording to Appendix A.
2.1.2. The probe head is connected to the test set
housing via a shielded cable terminated in a "SERVICE TEST SET" - The test set batteries
phone plug. Make sure the phone plug is prop- have dropped down below the 5.6V minimum
erly inserted into the phone jack on top of the test operational voltage. Replace the batteries in the
set housing. TS100 according to Section III and resume test-
ing.
2.2. TESTING.
" NEED SERVICE" - The beacon under test
2.2.1. Slide the switch on the side of the housing cannot be identified by the TS100. Remove the
to the "ON" position. The display will read beacon from service according to Appendix A.
"TESTING". (Note: The probe head must be
connected to a beacon prior to turning on the test 2.2.2. The result of the test will be diplayed for
set. If the probe head is not connected the test set approximately 10 seconds before returning to
will display "OPEN PROBE/BATT.") Within a read "READY FOR TEST ". A retest can be ini-
few seconds the display will read one of the fol- tated at any time by pressing the "TEST" button.
lowing messages:

03-TM-0014 REV 02 PAGE 2 of 8


2.2.3. If the beacon does not pass, check the 2.2.4. When testing is completed, slide the
probe head to make sure it is seated properly. switch on the side of the test set to the " OFF "
Poor contact between the beacon and the probe position. Failure to turn the test set off when not
head will give faulty readings. Wait until the in use will greatly reduce the test set's battery life.
TS100 has reset itself and then test the beacon.

03-TM-0014 REV 02 Page 3 of 8


SECTION III
MAINTENANCE

3.1. CLEANING. If the display needs to be


cleaned, wipe with a dry or slightly dampened
cloth.

CAUTION

THE TS100 PORTABLE TEST SET IS


NOT WATERPROOF. AVOID CON-
TACT WITH WATER OR SOLVENTS.

3.2. BATTERY REPLACEMENT. When the


battery voltage drops below the 5.6V minimum
operating voltage, the display will read
"SERVICE TEST SET". When this occurs, re-
place the batteries with (4) 1.5V "AA" NEDA
MN1500 Type batteries. To access the batteries,
remove the center screw in the small compart- Figure 3.1. Battery Replacement.
ment on the back of the TS100 as shown in Fig-
ure 3.1. Lift off the cover and replace the THE ELECTRONICS AND MAY
batteries in the same polarity as indicated. Re- CAUSE DAMAGE.
position the cover and replace the screw.
3.3. CALIBRATION. This unit has no adjust-
CAUTION able components inside.

DO NOT REMOVE THE SIX SCREWS THE TS100 IS SELF CHECKING, AND
THAT HOLD THE TEST SET HOUSING THEREFORE, REQUIRES NO
TOGETHER. THIS WILL EXPOSE CALIBRATION.

03-TM-0014 REV 02 PAGE 4 of 8


APPENDIX A
BEACON SERVICE

A.1. DK120 SERIES. the beacon from service and contact Dukane Cor-
poration, Seacom Division at (630) 584-2300,
The TS100 only performs a functional test on the Ext. 860 for further information about the DK120.
DK120. The functional test does not perform the
OFF Current test described in the DK120 Techni- A.2. DK100 SERIES.
cal Manual.
The batteries on the DK120 Series are user re- The battery in the DK100 Beacon is NOT field
placeable. See the DK120 Technical Manual for replaceable. If the TS100 indicates that a DK100
battery replacement and testing procedures. If the is not operating properly or needs a new battery,
TS100 Portable Test Set indicates that an DK120 remove the beacon from service and return it to
Series Beacon is not operating properly, remove Dukane Corporation according to Section A.5. A
the beacon from service. Replace the battery in copy of the DK100 Warranty and DK100 Service
the beacon and test as outlined in the Technical Program is contained in Sections A.3. and A.4.
Manual. If normal operation does not occur after respectively.
installation of a new battery, remove

03-TM-0014 REV 02 Page 5 of 8


A.3. DK100/DK120 WARRANTY

The Dukane Corporation warrants that the electronics and case of the Model DK100 or DK120 Under-
water Acoustic Beacon (hereafter referred to as the "unit") will be free from defects in materials and
workmanship for six years from the date of shipment from Dukane Corporation. Dukane Corporation
warrants that the battery in the DK100 or DK120 Underwater Acoustic Beacon (hereafter referred to as
the "battery") will be free of defects in materials and workmanship for four years from the date of ship-
ment from Dukane Corporation. Dukane Corporation will remanufacture or replace any unit or battery
found not to be in conformity with this warranty.

The customer shall be responsible for periodic testing of units in service, removing and shipping to Du-
kane Corporation any inoperative unit, and installing a replacement unit, all in accordance with the
Technical Manual published by Dukane Corporation. If a unit or battery is found by Dukane Corporation
to be defective, Dukane Corporation shall reimburse the Customer for all costs of shipping the unit to
Dukane Corporation, and pay for return shipment to the Customer. If the unit or battery is found not to
be defective, Customer shall pay all shipping costs to and from Dukane Corporation.

This warranty does not cover: (i) defects caused by the Customer’s failure to use, test or maintain any
unit in accordance with Dukane Corporation's Technical Manual; (ii) product failures caused by abuse,
misuse or neglect; or (iii) any product where the Customer has opened the unit, attempted any mainte-
nance, repair or service of the internal components, or replaced the battery.

Dukane Corporation's liability under this warranty is limited to remanufacture or replacement of a unit or
battery that is defective.

DUKANE CORPORATION SHALL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL


CONSEQUENTIAL OR EXEMPLARY DAMAGES ARISING OUT OF THE INSTALLATION,
USE, TESTING, SERVICING OR MAINTENANCE OF ANY UNIT.

THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR


IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.

03-TM-0014 REV 02 PAGE 6 of 8


A.4. DK100/DK120 SERVICE PROGRAM

A.4.1. BEACON RETURN -DEFECTIVE A. If the DK100 or DK120 Beacon is returned to


ELECTRONICS. Dukane Corporation and is found to be opera-
tional, the Beacon will be returned to the Cus-
A. In the case of an electronic failure which is tomer shipping collect. In addition, the Customer
determined to be within the Warranty (Section may be notified that a service charge applies.
A.3) terms, the DK100 or DK120 Beacon will be
repaired by Dukane Corporation at no cost to the A.4.4. BEACON RETURN -OUT OF
Customer. WARRANTY.

B. When the DK100 or DK120 Beacon is re- A. If the DK100 or DK120 Beacon is returned to
paired, it will be returned to the Customer with a Dukane Corporation and is found to be out of
new Warranty on the electronics. Warranty, the cost to repair the Beacon will be
determined and the Customer will be notified for
C. The battery will be replaced, if necessary. the appropriate approvals.

A.4.2. BEACON RETURN -DEFECTIVE A.4.5. BATTERY CHANGE/RECERTIFICA-


BATTERY. TION.

A. In the case of a battery failure which is deter- A. At or near the expiration date listed on the
mined to be within the Warranty (Section A.3) case, the DK100 Beacon must be returned to Du-
terms, the DK100 or DK120 Beacon will be re- kane Corporation for battery change and recertifi-
paired by Dukane Corporation at no cost to the cation to appropriate standards. (See Section
Customer during the first four years, after which, A.5.2.)
there is a service charge.
B. A certified DK100 Beacon with a new battery
A.4.3. BEACON RETURN -NO PROBLEM. will be returned to the Customer with a full war-
ranty.

C. At or near the expiration date listed on the


case, the battery of the DK120 Beacon must be
replaced with a new battery. Note: O-ring, lubri-
cant, and battery are provided in battery replace-
ment kit 810-2007/K. Contact Dukane
Corporation, Seacom Division at (630) 584-2300,
Ext. 860 for battery replacement kits.

Notes:

1. See Section A.5.1. for information about how to return the DK100 Beacon to Dukane Corporation
for Beacon service; or Section A.5.2. for Battery Change and Recertification.

2. Call Dukane Corporation, Seacom Division at (630) 584-2300, Ext. 860 for appropriate service
charges or further information about the DK100 Service Program.

03-TM-0014 REV 02 Page 7 of 8


A.5. PROCEDURE FOR RETURNING DK100/DK120 BEACON TO FACTORY

A.5.1. BEACON SERVICE. A.5.2. BATTERY CHANGE/RECERTIFICA-


TION.
A. PACKAGING.
A. PACKAGING.
Ensure that proper protection for the Beacon is
provided i.e. protection from inadvertent shorting Ensure that proper protection for the Beacon is
of the water switch and protection from surface provided i.e. protection from inadvertent shorting
scratches or abrasions. of the water switch and protection from surface
scratches or abrasions.
B. INFORMATION TO BE INCLUDED WITH
THE BEACON. B. PROCEDURE-CUSTOMER.

1. Reason for return. Call Dukane Corporation, Seacom Division’s


2. Serial Number of Beacon(s). Service Department, (630) 584-2300, Ext. 860, or
3. Return Authorization Number (See Para. C). via Fax (630) 584-5154. Provide the following
4. Credit memo information if required. information:
5. Purchase Order (if required) for Beacon
Replacement.
1. Quantity of Beacons being returned.
C. RETURN AUTHORIZATION. 2. Purchase Order number, if required, for
Beacon replacement.
Prior to shipping the DK100/DK120 Beacon to 3. Shipping and billing addresses.
Dukane Corporation, a Return Authorization 4. Shipping method.
Number is required and can be obtained from 5. Collect account number if required.
Dukane Corporation, Seacom Division’s Service
Department by calling (630) 584-2300 Ext. 860,
or via Fax (630) 584-5154. Ship Beacons to Dukane Corporation per
A.5.1.D. along with a copy of the Purchase Order.
D. SHIPPING INSTRUCTIONS.
C. PROCEDURE-DUKANE.
When the DK100/DK120 Beacon is returned un-
der warranty, ship via UPS surface. Upon receipt of the Beacons and a Purchase Or-
der, the appropriate quantity of recertified Bea-
Address all returns to: cons will be shipped FOB St. Charles, IL.

Dukane Corporation
Seacom Division
2900 Dukane Drive
St. Charles, IL 60174

Attn: Seacom Service Department


Code 860
Return Authorization Number

03-TM-0014 REV 02 PAGE 8 of 8