1. What is the Boucholz relay and the significance of it into the transformer?

A) Buchholz relay is a device that is used for the protection of a transformer from its internal faults, it
is a gas-based relay.
B) Buchholz relay is a device that is used to measure the winding temperature.
C) Buchholz relay is a device that is used for measuring the oil temperature.
D) All the Above

2. What is the difference between MCB & MCCB?


A) MCB is a miniature circuit breaker for High Current Ratings and MCCB is Moulded Case Circuit
Breaker for small Current Ratings.
B) MCB is a miniature circuit breaker for small Current Ratings and MCCB is Moulded Case Circuit
Breaker for High Current Ratings.
C) MCB is a miniature circuit breaker and MCCB is Moulded Case Circuit Breaker - both for High
Current Ratings.
D) MCB is a miniature circuit breaker and MCCB is Moulded Case Circuit Breaker - both for Low
Current Ratings

3. What is the current Transformer?


A) Current Transformer is used to measure the Voltage.
B) Current Transformer is used to measure the Power.
C) Current Transformer is used to measure the Current.
D) Current Transformer is used to measure the Frequency.

4. What is meant by earth wire?


A) The earth wire creates a safe route for the current to flow through if the live wire touches the
metallic casing of the electrical appliance. Thus it protects against electrical shocks.
B) The earth wire creates a safe route for the Voltage to flow through if the live wire touches the
metallic casing of the electrical appliance. Thus it protects against lightning.
C) The Earth wire is routed for only standard no other than any purposes.
D) None of the above

5. Why the insulation test is Important for Electrical Maintenance?


A) Insulation testing, tells you more about the Rating of insulation.
B) Insulation testing, tells you more about the size and properties of the Insulation.
C) Insulation testing, tells you more about the Healthiness of insulation for electrical systems.
D) Insulation test can identify the total length of the cables.

6. What Is VT?
A) VT Is used to measure the voltage & Protection.
B) VT is used to measure the Current
1
C) VT is used to measure the Power and Frequency.
D) VT is used for only protection.

7. Earthing should be applied for?

A) After Inform the control room


B) After finishing the electrical maintenance.
C) Middle of the electrical maintenance.
D) Before starting the Electrical maintenance

8. To perform the Electrical Maintenance?


A) After Approval of the engineer
B) After Approval of the Manger.
C) Obtaining an Electrical work permit & should be applied LOTO.
D) Once applied the earthing.

9. What is Protection Relay and what does do?


A) A protective relay is a relay device designed to trip a circuit breaker when a fault is detected.
B) A protective relay is a relay device designed to only measure the Fault when a fault is detected.
C) A protective relay is a relay device designed to only measure the Fault and send the signal to
Scada.
D) All the above

10. H.R.C Fuse, as Compared to a rewirable fuse, has?


A) No ageing Effect.
B) High Speed of operation
C) Both A&B
D) None of the above

11. The function of a breather in a Transformer is?


A) To provide oxygen inside the tank
B) To cool the Transformer oil
C) To arrest the flow of moisture when outside air enter the transformer.
D) To protect the transformer from Fault.

12. What is BMS System in Electrical Control Building?


A) Building Management Systems (BMS) control and monitor the large energy-consuming systems
within a building, such as HVAC, lighting, fire, and security systems. 
B) Building Management Systems (BMS) one of the devices in the electrical system
C) Building Management System(BMS) protects the electrical system from fault
D) All the above

13. What Is an HVAC System?


A) HVAC is an acronym that stands for High Voltage Alternate System
B) HVAC is an acronym that stands for High Voltage Automatic system
C) HVAC is an acronym that stands for Heating, Ventilation, and Air Conditioning
D) HVAC is an acronym that stands for High Voltage Airconditioning system

2
14. What Is VCB?
A) This type of circuit breaker uses vacuum media for quenching the arc.
B) This type of circuit breaker uses gas media for quenching the arc.
C) This type of circuit breaker uses special chemical media for quenching the arc.
D) This type of circuit breaker uses special oil media for quenching the arc.

15. The Insulation Resistance Value is zero means?


A) The power circuit is healthy.
B) The power Circuit is Unhealthy
C) The insulation Value is Healthy.
D) Both A&C

16. What is meant by Tool Box Talk?


A) A short and routine consultation designed to create awareness of safety measures and hazards at
the workplace.
B) A short and routine consultation designed to create awareness of using Hand tools.
C) A short and routine consultation designed to create awareness of society and industrial
Environment.
D) Discuss about the hand tools.

17. When earth fault occurs

A) Voltage potential at the earth mat increases due to earthing


B) Voltage potential at the earth decreases due to earthing
C) Voltage potential at the earth mat remains zero irrespective of fault.
D) None of the above.

18. What is the name of below test?

A) Contact Resistance test


B) Insulation Resistance Test
C) Winding Resistance Test
D) Bus bar High Voltage Test.

3
19. In a Transformer the energy conveyed from primary to secondary?
A) Through cooling coil
B) Through Air
C) By the Flux
D) None of the above.

20. A safety electrical one line diagram should be used to -----------all sources of electricity.
A) Identify
B) Castigate
C) Evaluate
D) Modify

4
Answers – for Electrical Foreman-Advanced

1. A) Buchholz relay is a device that is used for the protection of a transformer from its internal faults, it
is a Gas-based relay.

2. B) MCB is a miniature circuit breaker for small Current Ratings and MCCB is Moulded Case Circuit
Breaker for High Current Ratings

3. C) Current Transformer is used to measure the Current.

4. A) The earth wire creates a safe route for the current to flow through if the live wire touches the
Metallic casing of the electrical appliance. Thus it protects against electrical shocks.

5. C) Insulation testing, tells you more about the Healthiness of insulation for electrical systems.

6. A) VT Is used to measure the voltage & Protection

7. D) Before starting the Electrical maintenance

8. C) Obtaining an Electrical work permit & should be applied LOTO.

9. A) A protective relay is a relay device designed to trip a circuit breaker when a fault is detected.

10. C) Both A & B

11. C) To arrest the flow of moisture when outside air enter the transformer.

12. A) Building Management Systems (BMS) control and monitor the large energy-consuming systems
within a building, such as HVAC, lighting, fire, and security systems.

13. C) HVAC is an acronym that stands for Heating, Ventilation, and Air Conditioning

14. A) This type of circuit breaker uses vacuum media for quenching the arc.

15. B) The power Circuit is Unhealthy

16. A) A short and routine consultation designed to create awareness of safety measures and hazards at
the workplace.

17. A) Voltage potential at the earth mat increases due to earthing

18. A) Contact Resistance test

19. C) By the Flux