DISOCONT® Measurement, Control and Supervisory System

% Field housing electronics integration


able into scale mechanics

% New product line for ‘MechaTronic


scales’ a synthesis of mechanics,
electrics and software

% Reduced engineering planning and


wiring costs

% Optimal communication structures


because of modular fieldbus
technology

Application
DISOCONT is a modular electronics % At a glance - easy service because % Fieldbus communication modules
system applicable to any weighing and of the combination of mechanics and plugged into system unit for transfer
feeding system. It is used wherever bulk electronics of all relevant data to the user’s
solids flow has to be measured, feeded DISOCONT electronics may be conven- control and scale control system
or batched with the use of tionally installed in a control cubicle (e. g. % Input/output unit for conventional
% Loss-in-weight feeders for use with feeders in hazardous zones). connection to user’s control system
(measuring/feeding) The DISOCONT equipped with appropri- and expanded control of the scale
% Weighfeeders ate communication module optimally environment
% Mass flow meters and feeders integrates into the automation structure
% EasyServe - PC-program for
% Solids flow meters and feeders via field bus.
commissioning and service
% Belt weighers
% Weighing hoppers Equipment % Operator panel with clear graphic
text display for local scale control
The DISOCONT electronics are prefer- The DISOCONT electronics consist of a and/or parametrization of standard
rably integrated locally into the scale system unit and multiple optional expan- applications
mechanics. So self-contained function sion units. Its modular design enables the
units will be created - the MechaTronic requisite units to be combined for a spe- % Group control unit- operation, survey
scales - which offers numerous advan- cific application, at a most cost effective and control of scale groups, as
tages: price. shown in separate spec sheet
% Reduced engineering because of % System unit for all measuring and The internal DISOCONT communication
minimal number of interfaces; only control functions; equipped with bus permits a flexible arrangement of the
one unit has to be planned in service plug for connection of laptop I/O units, locally or in cabinets. All
% No control cubicle or control unit, for configuration, modules can be replaced with no need
% Reduced cabling; only power and calibration and service with an for recalibration and reconfiguration
data cables have to be run exchangeable memory module for (Plug & Play).
system specific settings and operat- The program includes housing options for
ing values installation at site and in control cubicles.

BV-D2051GB
Technical features for all weigh- With feeding applications, the % With solids flow meters and
ing and feeding systems: control deviation is acquired by feeders:
% System accuracy for scales feed rate set/actual comparison.
- Adaption to different
better than 0,05 % Depending on type of scale,
measuring chute
(DIN 43782) DISOCONT routes a control
characteristics
signal to
% Galvanically isolated inputs/ - Manual and automatic
outputs % speed-controlled weigh- zeroing
feeder drive - On stream material check
% Pluggable, fail-safe memory
module % controllable loss-in-weight % With mass flow meters and
feeder discharge unit feeders:
% Factory presettings for easy
and quick commissioning % controllable solids and mass - Accurate speed and torque
flow feeders’ prefeeders measurement
% Various languages loadable/
transferrable The control circuit exactly con- - Manual and automatic
trols the actual feed rate for con- zeroing
% Status, event, calibration, formity with setpoint. - Highly constant feeding
and batch reports - On stream material check
% Batch control with adaptive In batching mode, DISOCONT
% With loss-in-weight feeders
cut-off curve feeds a preset amount of mate-
(measuring and feeding):
% Integrated diagnostics and rial. System uses batch results
for automatic selfoptimization. - Adaptive FUZZY interference
self testing functions (SPC)
peak elimination
% Simulation mode for testing
Scale Specific Functions - Automatic correction of
and learning
material flow properties
Depending on the loaded scale
during filling
Functions software, the following function
- Highly constant feeding
DISOCONT is designed to are available.
- 4 sets of parameters for
acquire the actual feed rate % With belt weighers and quick adaptation on different
[kg/h, t/h] via weighfeeders: bulk solids
% belt load and belt speed for - Accurate belt speed
% Sequential batching:
belt weighers measurement
- Belt run monitoring - Sequence of up to
% changes in weight of material - Shifting of control for 10 material types
in weigh hopper per unit of weighing/feeding to point - Adaptive feed control
time for loss-in-weight of discharge
feeders - Belt influence compensa-
% reactive force for solids flow tion (BIC)
meters - Auto-calibration (automatic
% direct mass flow measure- calibration programs),
ment using the Coriolis force self-starting taring
for mass flow meters - Block control with weigh-
feeders = constant belt
load realized by pre-feeder
control
- On stream material check

Dimensions [mm]

DISOCONT–Housing Variants for System and Input/Output Units

Field housing VFG 20100 Control cubicle mounting housing VEG 20100
DISOCONT–Versions for Housing of the Control Unit

Field housing VLB 20120 VLB 20100, VLB 20105


In control panel/control cubicle housing

Technical Data

DISOCONT-System Unit VSE 20100 DISOCONT-Input/Output Unit VEA 20100


Power supply 24 VDC ±20 %; Power supply 24 VDC ±20 %;
110 V … 230 V -20 % +10 % 110 V … 230 V -20 % +10 %
(50 Hz or 60 Hz); 20 W (50 Hz or 60 Hz); 20 W
Ambient temperature -25 °C ... +50 °C Ambient temperature -25 °C ... +50 °C
outside housing outside housing
Inputs*) Load cell input Inputs*) 1 isolated analog output
(±6 V, Ri > 87 Ω) (0/4 ... 20 mA / 250 Ω)
2 NAMUR-Inputs 4 potential-free digital inputs
(0,03 … 3000 Hz for speed, belt (24 V, 20 mA, safety separated)
circuit/gate feedback signal) Outputs*) 1 isolated analog output
2 isolated digital inputs (0/4 mA ... 20 mA, max. 11 V)
(24 V, 20 mA, safety separated) 1 Impuls output (max. 50 mA)
Outputs*) 1 isolated analog output 5 relay outputs, safety-separated
(0/4 mA … 20 mA, max. 11 V) (24 V or. 230 V with combinations:
4 relay outputs, safety separated 4 x 24 V and 1 x 230 V or 4 x 230 V
(24 V or 230 V with combinations: and 1 x 24 V; 8 A Ω / 1 A induct.)
3 x 24 V and 1 x 230 V, or 3 x 230 V Interfaces RS232 (printer)
and 1 x 24 V; 8 A Ω / 1 A induct.) Internal DISOCONT-Bus
Interfaces RS232 (Service PC with EasyServe) Standards CE, UL
Internal DISOCONT-Bus
*) Internal signals are freely configured for physical
Standards CE, UL in-/outputs.

Field Housing VFG 20100 for Control Cubicle Housing VEG 20100 for
System or Input/Output Units System Unit or Input/Output Unit
Material Glass fibre reinforced plastics Material Stainless steel
Dimensions [mm] 260 x 160 x 90 Dimensions 250 x 146 x 98
[mm] For installing an DIN top-hat-rail or for wall mounting
Protected to IP65 (as per IEC 60529),
NEMA4-type Protected to IP20 (as per IEC 60529)
DISOCONT-Control Unit VLB 20120 DISOCONT-Control Unit VLB 20100
in Field Housing in Control Panel/Cubicle Housing

Material Glass fibre reinforced plastics Material Plastics


Dimensions [mm] 260 x 160 x 110 Dimensions [mm] Required space:
Protected to IP65 (as per IEC 60529), 240 x 120 x 65
NEMA4-type Cut-out:
231 + 0,5 x 111 + 0,5
Display [mm] LCD-graphics display (100 x 75)
Character height (3,5 or 9) Protected to Front to IP65 (as per IEC 60529)
Rear to IP20 (as per IEC 60529)
Keyboard Flexible membrane keyboard
Display [mm] LCD-graphics display (100 x 75)
Power supply 24 VDC ±20 %; Character height (3,5 or 9)
110 V … 230 V -20 % +10 %
(50 Hz or 60 Hz); 20 W Keyboard Flexible membrane keyboard

Ambient -20 °C ... +50 °C Ambient 0 °C ... +50 °C


temperature outside housing temperature outside housing
Internal DISOCONT-Bus interface

BV-D2051GB 1316 All information is given without obligation. All specifications are subject to change. © by Schenck Process GmbH, 2013
Interface Internal DISOCONT-Bus interface Interface

Standards CE Standards CE

The control unit VLB 20100 requires an


input/output unit for power supply.

DISOCONT-control unit VLB 20105 in


DISOCONT-Basic Units control-panel/control cubicle housing like
System Unit VSE 20100 with power supply VLB 20100, however:
Memory Module VSM 20100, VSM 20101, VSM 20102
Dimensions [mm] Required space:
Field housing without electronics VFG 20100 240 x 120 x 85
Suitable for system unit, input/output unit
Power supply 100 V … 240 V (50 Hz or 60 Hz);
Control cubicle housing without electronics VEG 20100 15 W
Suitable for system unit, input/output unit

DISOCONT-Expansion Units
DISOCONT-Function Modules Input/output unit VEA 20100 with power supply
Belt weigher software Control unit VLB 20120 in field housing with power supply
Weighfeeder software Control unit VLB 20100 in control panel/cubicle housing with
Loss-in-weight feeder software 2 m cable for connection to VEA 20100 input/output unit
Solids flow meter software Control unit VLB 20105 in control-panel/control cubicle
complete with power supply
Solids flow feeder software
EasyServe - PC-Program VPC 20150 on CD
Mass flow meter software
Mass flow feeder software
Optional Communication Modules
Sequential batching software
MULTICONT- SE-Bus-, Modbus-, J-Bus
or 3964(R) - Module VSB 20100
Optional DISOCONT-Master group rate control
station see separate data sheet BVD 2391 DeviceNet (CAN) - Module VCB 20100, VCB 20101
PROFIBUS DP - Module VPB 20100
Ethernet/TCP - Modbus Module VET 20100
Ethernet/IP - Module VET 20101