You are on page 1of 2

Close-in Boiler Connection Set

APPENDAGES
Close-in Boiler Connection Set
Contents
1a high-pressure water hose
0.5 m 10 clamp - 3/8”
coupling nut*
1b high-pressure water hose
0.5 m 10 clamp - Ø15 pipe
Ø10 mm
copper
1c high-pressure water hose
hot
0.5 m Ø15 pipe - 3/8”
cold coupling nut*
1a 1c 1b

3
2 copper pipe Ø15 50 mm
4
3 inlet combination DN 15
3/8"
flat
4 brass T-piece 3 x 15
hot cold
2
coupling
compression
6
7 5 flexible plastic hose
8 6 adapter to funnel
7 tie-wrap
5
boiler
Ø15 mm Ø40 mm
8 plastic T-piece, 40 x 40 x
copper cold
water pipe
PVC
discharge
25 mm
* 2 fibre washers for 3/8” flat
couplings included

Assumed is the following common situation: Code


• a 15 mm cold water pipe to the clamped
joint of the inlet combination 1250-0-05-21
• a sink drain (Ø40 mm PVC) in the

APPENDAGES
immediate vicinity of the boiler
• connections of the boiler with 3/8” male
thread

Fitting instructions
• fit the high-pressure hose with Ø15 mm
pipe and 10 mm clamp coupling (1b) to
the brass T-piece (4) and the cold-water
connection of the tap respectively
• turn the funnel of the inlet combination
Please note: connect the boiler in accordance (3) down in a vertical position and connect
with local rules and regulations! the flexible plastic hose (5) to the funnel,
• decide on the location of the boiler using the plastic adapter (6)
• thoroughly rinse the cold water pipe • connect the plastic hose (5) to the lower
• fit the high-pressure hose with 3/8” flat positioned T-piece (8) and fit this T-piece (8)
coupling and 10 mm clamped joint (1a) to the drain
to the hot-water connection of the boiler • using the plastic tie-wrap (7) to make a
and the hot-water connection of the tap U-shaped bend in the flexible hose (5) to
respectively prevent unwanted sewer smells
• fit the high-pressure hose with 3/8” flat • open the hot-water tap and the main valve
coupling and Ø15 mm pipe (1c) to the to fill the boiler with water
cold-water connection of the boiler and • close the hot-water tap as soon as water
the PenTec inlet combination (15 mm flows out, and check all water connections
clamped joint) (3) respectively for any leaks
• attach the PenTec inlet combination (3)
with the 15 mm clamped joint to the Ø15 Note
mm copper pipe supplied (2) and connect A small amount of water escaping from
this pipe to the brass T-piece (4) the relief valve is no reason for concern. It
• fit the brass T-piece 15 clamp (4) to the happens because the water is expanding by
cold water pipe approximately 3% of its original volume.